• 제목/요약/키워드: Contrast ultrasound

검색결과 142건 처리시간 0.028초

Feasibility of Percutaneous Pancreatic Stent Placement in Postoperative Pancreaticojejunostomy Stenosis

  • Juil Park;Kichang Han;Joon Ho Kwon;Man-Deuk Kim;Jong Yun Won;Sungmo Moon;Gyoung Min Kim
    • Korean Journal of Radiology
    • /
    • 제24권12호
    • /
    • pp.1241-1248
    • /
    • 2023
  • Objective: To evaluate the role of percutaneous pancreatic stent placement in postoperative pancreaticojejunostomy stenosis (PJS). Materials and Methods: This retrospective single-center study included seven procedures in five patients (four males and one female; median age, 63 years) who underwent percutaneous pancreatic stent placement for postoperative PJS between January 2005 and December 2021. The patients were referred to interventional radiology because of unfavorable anatomy or bowel abnormalities. The pancreatic duct was accessed under ultrasound and/or computed tomography guidance. A stent was placed after balloon dilatation of the PJS. Moreover, plastic stents were placed for the first two procedures, whereas bare-metal stents were used for the remaining five procedures. Technical success was defined as the successful placement of stents for the PJS, meanwhile, clinical success was defined as the normalization of pancreatic enzymes without recurrence of pancreatitis. Results: Pancreatic duct access and stent placement were successfully performed in all patients (technical success rate: 100%). All the procedures initially yielded clinical success. However, recurrence of pancreatitis was observed after two procedures that used plastic stents because of stent migration at 0.3 and 3 months after the procedure. In contrast, no instances of recurrent pancreatitis were noted after metal stent placement for a follow-up duration of 1-36 months. No serious procedure-related adverse events were observed. Conclusion: Percutaneous pancreatic stent placement may be a viable option for patients with postoperative PJS in whom an endoscopic approach is not feasible. Metal stents may be considered over plastic stents for the management of PJS, considering the possible lower stent migration and infeasibility of frequent endoscopic stent exchange due to the altered anatomy.

Detection of Malignant Primary Hepatic Neoplasms with Gadobenate Dimeglumine (Gd-BOPTA) Enhanced T1-Weighted Hepatocyte Phase MR Imaging: Results of Off-site Blinded Review in a Phase-II Multicenter Trial

  • Constantino S. Pena;Sanjay Saini;Richard L. Baron;Bernd A. Hamm;Giovanni Morana;Roberto Caudana;Andrea Giovagnoni;Andrea Villa;Alessandro Carriero;Didier Mathieu;Michael W. Bourne;Miles A. Kirchin;Gianpaolo Pirovano;Alberto Spinazzi
    • Korean Journal of Radiology
    • /
    • 제2권4호
    • /
    • pp.210-215
    • /
    • 2001
  • Objective: To investigate the efficacy of gadobenate dimeglumine (GdBOPTA) enhanced MR imaging for the detection of liver lesions in patients with primary malignant hepatic neoplasms. Materials and Methods: Thirty-one patients with histologically proven primary malignancy of the liver were evaluated before and after administration of GdBOPTA at dose 0.05 or 0.10 mmol/kg. T1-weighted spin echo (T1W-SE) and gradient echo (T1W-GRE) images were evaluated for lesion number, location, size and confidence by three off-site independent reviewers and the findings were compared to reference standard imaging (intraoperative ultrasound, computed tomography during arterial portography or lipiodol computed tomography). Results were analyzed for significance using a two-sided McNemar's test. Results: More lesions were identified on Gd-BOPTA enhanced images than on unenhanced images and there was no significant difference in lesion detection between either concentration. The largest benefit was in detection of lesions under 1 cm in size (7 to 21, 9 to 15, 16 to 18 for reviewers A, B, C respectively). In 68% of the patients with more than one lesion, Gd-BOPTA increased the number of lesions detected. Conclusion: Liver MR imaging after Gd-BOPTA increases the detection of liver lesions in patients with primary malignant hepatic neoplasm.

  • PDF

이물 객체 탐지 성능 개선을 위한 딥러닝 네트워크 기반 저품질 영상 개선 기법 개발 (Development of deep learning network based low-quality image enhancement techniques for improving foreign object detection performance)

  • 엄기열;민병석
    • 인터넷정보학회논문지
    • /
    • 제25권1호
    • /
    • pp.99-107
    • /
    • 2024
  • 경제성장과 산업 발전에 따라 반도체 제품부터 SMT 제품, 전기 배터리 제품에 이르기 까지 많은 전자통신 부품들의 제조과정에서 발생하는 철, 알루미늄, 플라스틱 등의 이물질로 인해 제품이 제대로 동작하지 않거나, 전기 배터리의 경우 화재를 발생하는 문제까지 심각한 문제로 이어질 가능성이 있다. 이러한 문제를 해결하기 위해 초음파나 X-ray를 이용한 비파괴 방법으로 제품 내부에 이물질이 있는지 판단하여 문제의 발생을 차단하고 있으나, X-ray 영상을 취득하여 이물질이 있는지 판정하는 데에도 여러 한계점이 존재한다. 특히. 크기가 작거나 밀도가 낮은 이물질들은 X-Ray장비로 촬영을 하여도 보이지 않는 문제점이 있고, 잡음 등으로 인해 이물들이 잘 안 보이는 경우가 있으며, 특히 높은 생산성을 가지기 위해서는 빠른 검사속도가 필요한데, 이 경우 X-ray 촬영시간이 짧아지게 되면 신호 대비 잡음비율(SNR)이 낮아지면서 이물 탐지 성능이 크게 저하되는 문제를 가진다. 따라서, 본 논문에서는 저화질로 인해 이물질을 탐지하기 어려운 한계를 극복하기 위한 5단계 방안을 제안한다. 첫번째로, Global 히스토그램 최적화를 통해 X-Ray영상의 대비를 향상시키고, 두 번째로 고주파 영역 신호의 구분력을 강화하기 위하여 Local contrast기법을 적용하며, 세 번째로 Edge 선명도 향상을 위해 Unsharp masking을 통해 경계선을 강화하여 객체가 잘 구분되도록 한다, 네 번째로, 잡음 제거 및 영상향상을 위해 Resdual Dense Block(RDB)의 초고해상화 방법을 제안하며, 마지막으로 Yolov5 알고리즘을 이용하여 이물질을 학습한 후 탐지한다. 본 연구에서 제안하는 방식을 이용하여 실험한 결과, 저밀도 영상 대비 정밀도 등의 평가기준에서 10%이상의 성능이 향상된다.

방사선치료 Patterns of Care Study 개발을 위한 2002년 한국 방사선종양학과 전문의들의 직장암 방사선치료 원칙 조사연구 (Survey on Radiotherpv Protocols for the Rectal Cancers Among the Korean Radiation Oncologists in 2002 for the Development of the Patterns of Care Study of Radiation Therapy)

  • 김종훈;김대용;김용호;김우철;김철용;성진실;손승창;신현수;안용찬;오도훈;오원용;유미령;유헝준
    • Radiation Oncology Journal
    • /
    • 제21권1호
    • /
    • pp.44-65
    • /
    • 2003
  • 목적 : 한국에서 발생빈도가 높은 암의 하나인 직장암의 치료에 있어 전국의 각 병원 치료방사선과(방사선종양학과)에서 시행하고 있는 치료 형태를 세부 항목별로 파악하여 방사선종양학 전문의간의 치료원칙의 차이점을 분석하고 이를 바탕으로 향후 Patterns of Care Study를 위한 연구의 기본 자료로 제시하고자 한다. 대상 및 방법 : 경인지역 소재 18개 대학병원 및 방사선종양학과가 있는 병원들의 방사선종양학과 전문의들이 모여 직장암의 방사선치료 원칙 분석을 위한 consensus committee를 구성하고, 회합 및 설문조사를 통하여 각 의사들의 방사선치료 원칙을 파악하기 위한 세부 항목 설정과 이를 토대로 직장암 환자 개개인의 치료 내용을 측정하는 구체적인 항목들을 개발하였다. 이 항목들을 이용하여 직장암의 방사선치료를 담당하고 있는 전국의 방사선종양학과 전문의들을 대상으로 설문조사를 시행한 후 각 전문의들의 의견이 일치하는 부분과 상이한 부분들을 분석하였다. 결과 : 전문의 별 치료원칙의 측정에 사용된 항목들은 1) 치료대상환자의 선정기준 8개 항목, 2) 수술 전후 병기 및 예후 인자 검사 20개 항목, 3) 수술 및 항암화학요법과의 병용기준 7개 항목, 4) 환자의 setup 및 처치 9개 항목, 5) 모의치료시 조사야 결정 19개 항목, 6) 치료계획 5개 항목, 7) 치료 중 상태 확인 위한 이학적/병리학적 검사 4개항목, 8) 치료 후 추적 관찰시 검사할 10개 항목 등 총 82개의 항목이 개발되었다. 이 항목들은 전국 각 병원들의 방사선종양학과 전문의를 대상으로 설문조사 되어 치료원칙에 대한 분석이 항목별로 이루어졌다. 설문조사 결과 전국의 각 병원 방사선종양학과에서 시행되고 있는 직장암의 방사선치료 형태는 일정 범위를 유지하고 있으나, 일부 항목에 있어서는 치료자 간 의견차이가 큰 것으로 나타났으며 이들 중 전체 응답자의 50$\%$ 이상에서 합의가 되지 못한 항목들은, 1) 치료환자의 선정 기준 중 수술 전 방사선치료 대상, 2) 병기 결정 검사 중 직장내 초음파 (EUS, endorectal ultrasound), 흉부 CT, 뼈 스캔 등의 시행 여부, 3) 항암제와의 병용 원칙, 4) 모의치료시 소장 위치확인을 위한 조영제 사용, 5) 조사야의 경계선 결정, 6) 치료 후 추적 관찰 시 CEA와 대장내시경의 시행여부 등 이었다. 결론 이견이 많은 항목들에 대해서는 향후 담당 전문의들을 대상으로 consensus meeting 등을 통한 체계적인 분석 및 합의의 도출이 필요한 것으로 보이며, 본 연구에서 밝혀진 각 병원들의 치료 내용을 토대로 향후 표준화된 치료 모델 개발을 위한 Patterns of Care Study가 진행될 예정이다.

Ovarian Masses: Is Multi-detector Computed Tomography a Reliable Imaging Modality?

  • Khattak, Yasir Jamil;Hafeez, Saima;Alam, Tariq;Beg, Madiha;Awais, Mohammad;Masroor, Imrana
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권4호
    • /
    • pp.2627-2630
    • /
    • 2013
  • Background: Ovarian cancer continues to pose a major challenge to physicians and radiologists. It is the third most common gynecologic malignancy and estimated to be fifth leading cancer cause of death in women, constituting 23% of all gynecological malignancies. Multi-detector computed tomography (MDCT) appears to offer an excellent modality in diagnosing ovarian cancer based on combination of its availability, meticulous technique, efficacy and familiarity of radiologists and physicians. The aim of this study was to compute sensitivity, specificity, positive and negative predictive values and diagnostic accuracy of 64-slice MDCT in classifying ovarian masses; 95% confidence intervals were reported. Materials and Methods: We prospectively designed a cross-sectional analytical study to collect data from July 2010 to August 2011 from a tertiary care hospital in Karachi, Pakistan. A sample of 105 women aged between 15-80 years referred for 64-MDCT of abdomen and pelvis with clinical suspicion of malignant ovarian cancer, irrespective of stage of disease, were enrolled by non-probability purposive sampling. All patients who were already known cases of histologically proven ovarian carcinoma and having some contraindication to radiation or iodinated contrast media were excluded. Results: Our prospective study reports sensitivity, specificity; positive and negative predictive values with 95%CI and accuracy were computed. Kappa was calculated to report agreement among the two radiologists. For reader A, MDCT was found to have 92% (0.83, 0.97) sensitivity and 86.7% (0.68, 0.96) specificity, while PPV and NPV were 94.5% (0.86, 0.98) and 86.7% (0.63, 0.92), respectively. Accuracy reported by reader A was 90.5%. For reader B, sensitivity, specificity, PPV and NPV were 94.6% (0.86, 0.98) 90% (0.72, 0.97) 96% (0.88, 0.99) and 87.1% (0.69, 0.95) respectively. Accuracy computed by reader B was 93.3%. Excellent agreement was found between the two radiologists with a significant kappa value of 0.887. Conclusion: Based on our study results, we conclude MDCT is a reliable imaging modality in diagnosis of ovarian masses accurately with insignificant interobserver variability.

경추 초음파 영상에서 흉쇄유돌근 추출 (Extraction of Sternocleidomastoid Muscle for Ultrasound Images of Cervical Vertebrae)

  • 김광백
    • 한국정보통신학회논문지
    • /
    • 제15권11호
    • /
    • pp.2321-2326
    • /
    • 2011
  • 경추는 머리와 몸통을 이어주는 중요한 요충지이기 때문에 매우 중요한 기관이며 매우 복잡한 구조로 되어있다. 본 논문에서는 경추 초음파 영상에서 경추 부분에 존재하는 흉쇄유돌근을 자동으로 검출하는 방법을 제안한다. 경추 초음파 영상에서 촬영 정보나 눈금자 등의 필요 없는 부분을 제외한 ROI(Region of Interest)영상을 추출하고 Ends-In Search Stretching 알고리즘을 적용하여 명암 대비를 강조한다. Stretching된 영상에 20 이상의 명암도를 가지는 픽셀을 대상으로 평균 이진화를 적용한 후, 잡음을 제거한다. 잡음이 제거된 영상에 흉쇄유돌근을 둘러싸고 있는 근막의 위치 정보를 이용하여 근막을 추출한 후, 근막의 객체 수에 따라서 각기 다른 방법을 적용하여 근육을 추출한다. 근막 객체가 하나인 경우에는 위에서 아래로 탐색하여 1차 근육 영역을 추출하고, 오른쪽에서 왼쪽으로 탐색하여 2차 근육 영역을 추출한 후, 1차와 2차 근육 영상을 하나로 합쳐 최종 근육 영역을 추출한다. 근막 객체가 두 개인 경우에는 근막 객체의 상단과 하단까지의 영역을 모두 추출한 후, 근막 객체 영역을 제거하는 방법으로 근육 영역을 추출한다. 추출된 근육 영역 중에서 두께가 가장 두꺼운 부분을 근육의 두께로 측정한다. 본 논문에서 제안된 방법을 경추 초음파 영상 30장을 대상으로 실험하여 물리치료사가 분석한 결과, 제안된 방법이 흉쇄유돌근을 정확히 추출되는 것을 확인하였다.

Ultrasonic Degradation of Endocrine Disrupting Compounds in Seawater and Brackish Water

  • Park, So-Young;Park, Jong-Sung;Lee, Ha-Yoon;Heo, Ji-Yong;Yoon, Yeo-Min;Choi, Kyung-Ho;Her, Nam-Guk
    • Environmental Engineering Research
    • /
    • 제16권3호
    • /
    • pp.137-148
    • /
    • 2011
  • In this study, a series of experiments was conducted on the relative degradation of commonly known endocrine-disrupting compounds such as bisphenol A (BPA) and $17{\alpha}$-ethinyl estradiol (EE2) in a single-component aqueous solution using 28 and 580 kHz ultrasonic reactors. The experiments were conducted with three different types of model water: deionized water (DI), synthetic brackish water (SBW), and synthetic seawater (SSW) at pH 4, 7.5, and 11 in the presence of inert glass beads and humic acids. Significantly higher sonochemical degradation (93-97% for BPA) occurred at 580 kHz than at 28 kHz (43-61% for BPA), regardless of water type. A slightly higher degradation was observed for EE2 compared to that of BPA. The degradation rate of BPA and EE2 in DI water, SBW, and SSW after 30 min of ultrasound irradiation at 580 kHz increased slightly with the increase in pH from 4 (0.073-0.091 $min^{-1}$ for BPA and 0.081-0.094 $min^{-1}$ for EE2) to 7.5 (0.087-0.114 $min^{-1}$ for BPA and 0.092-0.124 $min^{-1}$ for EE2). In contrast, significant degradation was observed at pH 11 (0.149-0.221 $min^{-1}$ for BPA and 0.147-0.228 $min^{-1}$ for EE2). For the given frequencies of 28 and 580 kHz, the degradation rate increased in the presence of glass beads (0.1 mm and 25 g) for both BPA and EE2: 0.018-0.107 $min^{-1}$ without beads and 0.052-0.142 $min^{-1}$ with beads for BPA; 0.021-0.111 $min^{-1}$ without beads and 0.054-0.136 $min^{-1}$ with beads for EE2. A slight increase in degradation of both BPA and EE2 was found as the concentration of dissolved organic carbon (DOC, humic acids) increased in both SBW and SSW: 0.107-0.115 $min^{-1}$ in SBW and 0.087-0.101 $min^{-1}$ in SSW for BPA; 0.111-0.111 $min^{-1}$ in SWB and 0.092-0.105 $min^{-1}$ in SSW for EE2. After 30 min of sonicating the humic acid solution, DOC removal varied depending on the water type: 27% (3 mg $L^{-1}$) and 7% (10 mg $L^{-1}$) in SBW and 7% (3 mg $L^{-1}$) and 4% (10 mg $L^{-1}$) in SSW.

전립선비대증 초음파 영상에서 GLCM을 이용한 컴퓨터보조진단의 영상분석 (Image Analysis of Computer Aided Diagnosis using Gray Level Co-occurrence Matrix in the Ultrasonography for Benign Prostate Hyperplasia)

  • 조진영;김창수;강세식;고성진;예수영
    • 한국콘텐츠학회논문지
    • /
    • 제15권3호
    • /
    • pp.184-191
    • /
    • 2015
  • 전립선 초음파영상은 전립선암, 전립선비대증, 전립선염을 진단하고 전립선암의 생검과 전립선비대에서 전립선 크기 확인 등을 위해서 사용된다. 전립선비대증은 노인 남성의 가장 흔한 질병 중의 하나이다. 전립선은 주변구역, 중심구역, 이행구역과 전방 섬유근 간질부분 4개 구획으로 나누어진다. 전립선비대증은 조직학적으로 전립선 이행구역에서 결절성 증식을 동반한 요도주위의 진행성 과증식이 특징으로 이 결절로 인한 요도 폐쇄를 야기함에 따라 하부요로 증상을 유발한다. 그러므로 본 연구에서는 정상 전립선 이행구역 영상과 전립선비대 이행구역 영상에 대한 컴퓨터 알고리즘을 이용하여 정량적인 분석을 하였다. GLCM을 적용하여 정상영상 60증례와 전립선비대증영상 60증례을 분석영역($50{\times}50$ 픽셀)으로 설정하고, 각 영상에서 Autocorrelation, Contrast, Cluster Prominence, Entropy, Max Probability, Sum average 6가지 파라미터를 비교하여 분석하였다. 결과적으로 Autocorrelation, Cluster Prominence, Entropy, Sum Average 4개의 파라미터에서는 병변의 질감 검출 효율이 92-98%로 높게 나왔다. 이에 전립선 이행구역의 결절성 증식 변화를 정량적인 영상분석으로 확인 할 수 있었다. 향후 전립선비대증 진단에 있어 2차적인 수단으로 가능할 것으로 기대되며, 다양한 전립선 초음파 영상에 있어 기초 자료가 될 것으로 사료된다.

Current Trends and Recent Advances in Diagnosis, Therapy, and Prevention of Hepatocellular Carcinoma

  • Wang, Chun-Hsiang;Wey, Keh-Cherng;Mo, Lein-Ray;Chang, Kuo-Kwan;Lin, Ruey-Chang;Kuo, Jen-Juan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권9호
    • /
    • pp.3595-3604
    • /
    • 2015
  • Hepatocellular carcinoma (HCC) has been one of the most fatal malignant tumors worldwide and its associated morbidity and mortality remain of significant concern. Based on in-depth reviews of serological diagnosis of HCC, in addition to AFP, there are other biomarkers: Lens culinaris agglutinin-reactive AFP (AFP-L3), descarboxyprothrombin (DCP), tyrosine kinase with Ig and eprdermal growth factor (EGF) homology domains 2 (TIE2)-espressing monocytes (TEMs), glypican-3 (GPC3), Golgi protein 73 (GP73), interleukin-6 (IL-6), and squamous cell carcinoma antigen (SCCA) have been proposed as biomarkers for the early detection of HCC. The diagnosis of HCC is primarily based on noninvasive standard imaging methods, such as ultrasound (US), dynamic multiphasic multidetector-row CT (MDCT) and magnetic resonance imaging (MRI). Some experts advocate gadolinium diethyl-enetriamine pentaacetic acid (Gd-EOB-DTPA) MRI and contrast-enhanced US as the promising imaging madalities of choice. With regard to recent advancements in tissue markers, many cuting-edge technologies using genome-wide DNA microarrays, qRT-PCR, and proteomic and inmunostaining studies have been implemented in an attempt to identify markers for early diagnosis of HCC. Only less than half of HCC patients at initial diagnosis are at an early stage treatable with curative options: local ablation, surgical resection, or liver transplant. Transarterial chemoembolization (TACE) is considered the standard of care with palliation for intermediate stage HCC. Recent innovative procedures using drug-eluting-beads and radioembolization using Yttrium-90 may exhibit beneficial effects in HCC treatment. During the past few years, several molecular targeted agents have been evaluated in clinical trials in advanced HCC. Sorafenib is currently the only approved systemic treatment for HCC. It has been approved for the therapy of asymptomatic HCC patients with well-preserved liver function who are not candidates for potentially curative treatments, such as surgical resection or liver transplantation. In the USA, Europe and particularly Japan, hepatitis C virus (HCV) related HCC accounts for most liver cancer, as compared with Asia-Pacific regions, where hepatitis B virus (HBV) may play a more important role in HCC development. HBV vaccination, while a vaccine is not yet available against HCV, has been recognized as a best primary prevention method for HBV-related HCC, although in patients already infected with HBV or HCV, secondary prevention with antiviral therapy is still a reasonable strategy. In addition to HBV and HCV, attention should be paid to other relevant HCC risk factors, including nonalcoholic fatty liver disease due to obesity and diabetes, heavy alcohol consumption, and prolonged aflatoxin exposure. Interestingly, coffee and vitamin K2 have been proven to provide protective effects against HCC. Regarding tertiary prevention of HCC recurrence after surgical resection, addition of antiviral treatment has proven to be a rational strategy.

생체 외 조건의 소 경골에서 초음파를 이용하여 피질골 두께를 측정하기 위한 방법 (Ultrasonic methods for measuring the cortical bone thickness in bovine tibia in vitro)

  • 이강일
    • 한국음향학회지
    • /
    • 제41권5호
    • /
    • pp.557-563
    • /
    • 2022
  • 경골의 피질골 두께는 골절 위험 및 전반적인 골 상태와 관련이 있다. 본 연구의 목적은 생체 외 조건의 소경골에서 초음파를 이용하여 피질골 두께를 측정하기 위한 두 가지 다른 방법의 타당성을 조사하는 것이다. 반사법에서 경골의 피질골 두께는 신호 포락선에서 특정 피크를 생성하는 골외막 및 골내막으로부터의 초음파 반사로부터 결정되었다. 축방향 전달법에서 경골의 피질골 두께는 경골의 축방향을 따라 측정된 유도 초음파의 속도로부터 결정되었다. 반사법을 이용하여 측정된 피질골 두께는 캘리퍼스를 이용하여 측정된 피질골 두께와 r = 0.97(p < 0.0001)의 유의미한 피어슨 상관관계수를 나타냈다. 반면, 축방향 전달법을 이용하여 측정된 피질골 두께는 캘리퍼스를 이용하여 측정된 피질골 두께와 최초 도달 신호 방법의 경우에 r = 0.92(p < 0.0001), 느린 유도파 방법의 경우에 r = 0.89(p < 0.0001)의 상관관계수를 나타냈다. 본 연구에서 제시된 초음파 측정법이 골다공증의 스크리닝 도구로서 유용할 수 있고, 잠재적으로 대퇴골 및 요골과 같은 다른 골격 부위에 적용될 수 있는지 여부를 확인하기 위해서는 생체 내 조건에서 임상적 타당성이 입증되어야 한다.