• 제목/요약/키워드: Contrast to noise ratio

검색결과 296건 처리시간 0.029초

인터벤션에서 자동노출제어장치와 수동노출 사용 시 두께 변화에 따른 선량감소 방안 연구 (A Study on Dose Reduction Method according to Slice Thickness Change using Automatic Exposure Controller and Manual Exposure in Intervention)

  • 황준호;정구민;최지안;김현수;이경배
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권2호
    • /
    • pp.115-122
    • /
    • 2018
  • We aims to perform comparative analysis on the dose area and image qualities varying on the slice thickness when using Automatic Exposure Controller (AEC) and manual exposure; thus, it wants to suggest a measure to reduce exposure dose by setting the optimal examination condition for each slice thickness. The method was to set the thickness as Thin, Normal, and Heavy adult and evaluate the dose area, spatial resolution, low contrast resolution, Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) according to each slice thickness by using the AEC and the manual exposure controller. The dose area according to each slice thickness all increased both when using the AEC and the manual exposure. However, the manual exposure showed lower dose area product than the AEC. Spatial resolutions and low contrast resolutions were all observed to be higher than the evaluation standard. Also, the SNR and CNR of each thickness all increased when using the AEC. When using the manual exposure, SNR and CNR increased in all cases other than the Heavy Adult. Consequently, the Thin and Normal Adult showed dose reduction about 2 times when using the manual exposure controller, while ensuring the image quality. Heavy adult was able to maintain good image quality by using AEC.

심장 혈관 조영장치에서의 프레임 레이트(f/s) 변화에 따른 상관 관계 분석 : FOV 확대와 Live Zoom을 중점으로 (Analysis of the Relationships according to the Frame (f/s) Change of Cine Imaging in Coronary Angiographic System: With Focus on FOV Enlargement and Live Zoom)

  • 김원효;송종남;한재복
    • 한국방사선학회논문지
    • /
    • 제12권7호
    • /
    • pp.845-852
    • /
    • 2018
  • 본 연구는 심장 혈관 조영술의 투시 영상과 씨네 영상을 획득하는 데 있어서 초당 프레임 횟수를 변화함에 따라 흡수선량과 획득 영상의 화질의 추이를 살펴보는 것을 목적으로 한다. 또, FOV 확대와 Live Zoom이라는 두 가지 확대 모드에 따른 변화도 고찰 대상으로 한다. 인체모형 팬텀을 심장 혈관 조영장치 위에서 초당 프레임 횟수를 7.5, 15, 30 f/s로 설정하고 두 가지 확대 모드에 대하여 각각 5회씩 촬영하였다. 선량의 척도로서는 흡수선량과 에어 커머가 사용되었고, 화질 평가의 척도로는 잡음의 세기로서의 표준 편차(SD), 신호 대 잡음비(SNR)와 대조도 대 잡음비(CNR) 등을 활용하였다. 초당 프레임 횟수가 30부터 15, 7.5 f/s로 감소되었을 때, DAP와 에어 커머는 동일한 비율로 감소하였으나, 화질의 척도인 SD, SNR과 CNR은 거의 변화가 없었다. 확대 모드에의 의존도에 관해서는, Live Zoom이 FOV 확대와 비교하였을 때, DAP, 에어 커머와 SD에 대해서는 통계적 의미 있는 차이를 보이지 않았으나, SNR과 CNR에 있어서는 통계적 유의미한 개선을 보였다. 이러한 실험 결과에 의하여, 초당 프레임 횟수는 화질의 열화 없이 되도록 낮게 설정하는 것이 가능하며, 확대 모드도 추가적인 선량 없이 실시간 확대가 가능한 Live Zoom 모드를 적극적으로 활용 가능하며 이는 화질의 여러 척도의 저하를 가져오지 않음을 알 수 있었다.

검사 조건 제어와 반복 재구성의 조합을 이용한 흉부 CT의 선량 저감화 방안 (Dose Reduction Method for Chest CT using a Combination of Examination Condition Control and Iterative Reconstruction)

  • 김상현
    • 한국방사선학회논문지
    • /
    • 제17권7호
    • /
    • pp.1025-1031
    • /
    • 2023
  • 저선량흉부 CT (Low Dose chest CT, LDCT)에서 Scout 관전압을 변화시키고 scan parameter인 자동노출제어장치(Auto Exposure Control, AEC)와 적응식 반복재구성기법(Adaptive Statistical Iterative Reconstruction, ASIR)등을 적용하여 최적의 프로토콜을 찾음으로써 방사선 피폭선량과 화질을 평가하고자 하였다. Scout 관전압을 80, 100, 120, 140 kV로 변화시키며 LDCT 프로토콜로 5회 반복 측정 후 선량을 비교하기 위해 장비에서 제공된 Dose report를 이용하여 연구 목적에 적합한 관전압을 선택하였다. 120 kV, 30 mAs의 조건으로 기본 LDCT 촬영한 후, 이 조건에 ASIR 50%를 적용하였으며 신호대잡음비와 대조도대잡음비를 평가하기 위해 배경의 노이즈를 측정하였다. 선량 비교를 위해 장비에서 제공되는 CTDIvol과 선량길이곱(Dose length product, DLP)를 식을 이용하여 비교 분석하였다. 그 결과 S140 + LDCT + ASIR 50 + AEC를 적용한 프로토콜에서 고식적인 LCDT보다 방사선 피폭선량을 감소시키고 영상의 질을 향상시켰으며 최적의 프로토콜을 얻을 수 있었으며 LDCT는 매 검사 시 필요 이상의 피폭선량이 우려되기 때문에 적절한 Parameter를 적용하는 것이 중요하며, 향후 LDCT를 이용한 건강검진에서 국민의 건강에 이바지 하는데 긍정적인 요인으로 작용될 것으로 사료된다.

Edge Preserving Smoothing in Infrared Image using Relativity of Guided Filter

  • Kim, Il-Ho
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권12호
    • /
    • pp.27-33
    • /
    • 2018
  • In this paper, we propose an efficient edge preserving smoothing filter for Infrared image that can reduce noise while preserving edge information. Infrared images suffer from low signal-to-noise ratio, low edge detail information and low contrast. So, detail enhancement and noise reduction play crucial roles in infrared image processing. We first apply a guided image filter as a local analysis. After the filtering process, we optimization globally using relativity of guided image filter. Our method outperforms the previous methods in removing the noise while preserving edge information and detail enhancement.

Performance evaluation of noise reduction algorithm with median filter using improved thresholding method in pixelated semiconductor gamma camera system: A numerical simulation study

  • Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제51권2호
    • /
    • pp.439-443
    • /
    • 2019
  • To improve the noise characteristics, software-based noise reduction algorithms are widely used in cadmium zinc telluride (CZT) pixelated semiconductor gamma camera system. The purpose of this study was to develop an improved median filtering algorithm using a thresholding method for noise reduction in a CZT pixelated semiconductor gamma camera system. The gamma camera system simulated is a CZT pixelated semiconductor detector with a pixel-matched parallel-hole collimator and the spatial resolution phatnom was designed with the Geant4 Application for Tomography Emission (GATE). In addition, a noise reduction algorithm with a median filter using an improved thresholding method is developed and we applied our proposed algorithm to an acquired spatial resolution phantom image. According to the results, the proposed median filter improved the noise characteristics compared to a conventional median filter. In particular, the average for normalized noise power spectrum, contrast to noise ratio, and coefficient of variation results using the proposed median filter were 10, 1.11, and 1.19 times better than results using conventional median filter, respectively. In conclusion, our results show that the proposed median filter using improved the thresholding method results in high imaging performance when applied in a CZT semiconductor gamma camera system.

PET/MR 영상에서의 팬텀을 활용한 노이즈 감소를 위한 변형된 중간값 위너필터의 적용 효율성 연구 (Efficiency of Median Modified Wiener Filter Algorithm for Noise Reduction in PET/MR Images: A Phantom Study)

  • 조영현;이세정;이영진;박찬록
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.225-229
    • /
    • 2021
  • The digital image such as medical X-ray and nuclear medicine field mainly contains noise distribution. The noise degree in image degrades image quality. That is why, the noise reduction algorithm is efficient for medical image field. In this study, we confirmed effectiveness of application for median modified Wiener filter (MMWF) algorithm for noise reduction in PET/MR image compared with median filter image, which is used as conventional noise redcution algorithm. The Jaszczak PET phantom was used by using 18F solution and filled with NaCl+NiSO4 fluids. In addition, the radioactivity ratio between background and six spheres in the phantom is maintained to 1:8. In order to mimic noise distribution in the image, we applied Gaussian noise using MATLAB software. To evlauate image quality, the contrast to noise ratio (CNR) and coefficient of variation (COV) were used. According to the results, compared with noise image and images with MMWF algorithm, the image with MMWF algorithm is increased approximately 33.2% for CNR result, decreased approximately 79.3% for COV result. In conclusion, we proved usefulness of MMWF algorithm in the PET/MR images.

Optimum Superimposed Training for Mobile OFDM Systems

  • Yang, Qinghai;Kwak, Kyung-Sup
    • Journal of Communications and Networks
    • /
    • 제11권1호
    • /
    • pp.42-46
    • /
    • 2009
  • Superimposed training (SIT) design for estimating of time-varying multipath channels is investigated for mobile orthogonal frequency division multiplexing (OFDM) systems. The design of optimum SIT consists of two parts: The optimal SIT sequence is derived by minimizing the channel estimates' mean square error (MSE); the optimal power allocation between training and information data is developed by maximizing the averaged signal to interference plus noise ratio (SINR) under the condition of equal powered paths. The theoretical analysis is verified by simulations. For the metric of the averaged SINR against signal to noise ratio (SNR), the theoretical result matches the simulation result perfectly. In contrast to an interpolated frequency-multiplexing training (FMT) scheme or an SIT scheme with random pilot sequence, the SIT scheme with proposed optimal sequence achieves higher SINR. The analytical solution of the optimal power allocation is demonstrated by the simulation as well.

FHD급 DIC 플랫폼의 변위계측용 영상품질 분석 (Analysis of DIC Platform and Image Quality with FHD for Displacement Measurement)

  • 박종배;강민구
    • 인터넷정보학회논문지
    • /
    • 제19권1호
    • /
    • pp.105-111
    • /
    • 2018
  • 건축 구조물의 상대적인 변위 계측을 위하여 2메가 픽셀 Full HD(FHD) 해상도의 카메라와 디지털 영상상관(DIC, Digital Image Correlation) 플랫폼을 설계하고, 계측에 영향을 주는 영상 품질을 분석하였다. DIC 플랫폼은 Freescale사의 I.MX6를 기반으로 설계하였다. 영상 상관을 이용한 계측은 영상의 품질에 따라 계측 정밀도에 영향을 줄 수 있는데, 이러한 영상 품질 요인으로 영상의 밝기(brightness), 대조(contrast), 신호대 잡음비(SNR, Signal to Noise Ratio)를 분석하였다. 관심 영역(ROI, Region Of Interest)으로 설정한 부분에서 추출한 영상을 기준 영상으로 삼고, 일정 시간 경과 후 디지털 영상 상관(DIC)을 이용하여 기준 영상의 이동을 화소 및 부화소 단위로 추적 계산하여 변위를 측정하였다. 더불어 DIC 기반의 비접촉 원격 계측의 유효성을 파악하기 위하여 25m, 35m, 50m의 계측 거리에서, 영상 품질 요인 및 ROI 의 크기를 조정하여 측정을 하고 정밀도를 분석하였다.

The Effects of Image Dehazing Methods Using Dehazing Contrast-Enhancement Filters on Image Compression

  • Wang, Liping;Zhou, Xiao;Wang, Chengyou;Li, Weizhi
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권7호
    • /
    • pp.3245-3271
    • /
    • 2016
  • To obtain well-dehazed images at the receiver while sustaining low bit rates in the transmission pipeline, this paper investigates the effects of image dehazing methods using dehazing contrast-enhancement filters on image compression for surveillance systems. At first, this paper proposes a novel image dehazing method by using a new method of calculating the transmission function—namely, the direct denoising method. Next, we deduce the dehazing effects of the direct denoising method and image dehazing method based on dark channel prior (DCP) on image compression in terms of ringing artifacts and blocking artifacts. It can be concluded that the direct denoising method performs better than the DCP method for decompressed (reconstructed) images. We also improve the direct denoising method to obtain more desirable dehazed images with higher contrast, using the saliency map as the guidance image to modify the transmission function. Finally, we adjust the parameters of dehazing contrast-enhancement filters to obtain a corresponding composite peak signal-to-noise ratio (CPSNR) and blind image quality assessment (BIQA) of the decompressed images. Experimental results show that different filters have different effects on image compression. Moreover, our proposed dehazing method can strike a balance between image dehazing and image compression.

Sparse 표현을 이용한 이중 에너지 X 선 흡수 영상 잡음 제거 (Noise Reduction for Dual-energy X-ray Absorptiometry Image using Sparse Representation)

  • 김형일;엄원용;김대회;노용만
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2012년도 춘계학술발표대회
    • /
    • pp.369-372
    • /
    • 2012
  • 대사성 골 질환인 골다공증(Osteoporosis)의 조기 진단을 위한 골 밀도를 측정하는 방법이 최근 연구되고 있다. 골 밀도 영상은 이중 에너지 X 선 흡수법에 의해 측정되는데, 영상에 존재하는 잡음은 뼈 영역 추출과 골 밀도 계산에 어려움을 주고 있다. 따라서 본 논문에서는 최근 신호처리 분야에서 폭넓게 사용되고 있는 sparse 표현을 도입하여 X 선 영상의 잡음을 제거하는 방법을 제안한다. 실험을 통해 제안한 잡음 제거 방법의 결과가 기존의 방법에 비해 개선됨을 MSR(Mean to Standard deviation Ratio)과 CNR(Contrast to Noise Ratio)을 통해 확인하였다.