• 제목/요약/키워드: Contraction force

검색결과 275건 처리시간 0.023초

Muscarinic Receptor Subtype Controlling the Carbachol-Induced Muscle Contraction in Guinea Pig Gastric Antrum

  • Rhee, Jong-Chul;Uhm, Dae-Yong;Kang, Tong-Mook
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제4권2호
    • /
    • pp.105-111
    • /
    • 2000
  • Stimulation of muscarinic receptors by carbachol (CCh) in the circular smooth muscle of the guinea pig gastric antrum causes muscle contraction. In the present study, muscarinic receptor subtype controlling the muscle contraction in response to CCh was studied using putative muscarinic receptor antagonists. Isometric force of the isolated circular muscle strips was measured in an organ bath. CCh contracted the muscle in a dose-dependent way, and each of the three muscarinic receptor antagonists, 4-diphenylacetoxy- N-methylpeperdine methiodide (4-DAMP), methoctramine and pirenzepine shifted the concentration- response curves to the right without significantly reducing the maximum force. The affinities of the muscarinic antagonists $(pA_2\;values)$ obtained from Schild plot analysis were 10.15, 7.05 and 6.84 for 4-DAMP, methoctramine and pirenzepine, respectively. These results suggest that the $M_3-subtype$ mainly mediate the muscle contraction in response to CCh in guinea pig gastric antrum.

  • PDF

대퇴절단환자의 고관절 등속성근력비율에 관한 연구 (A Study on Isokinetic Strength Ratios of Hip joints in Above-knee Amputees)

  • 송창호;이완희
    • 대한물리치료과학회지
    • /
    • 제10권1호
    • /
    • pp.74-82
    • /
    • 2003
  • The purpose of this study is to provide guideline of muscle strengthening exercise for preparing ambulation by presenting suitable ratio of muscle power of agonist & antagonist, and that of concentric & eccentric contraction on behalf of amputee's normal ambulation training and it's strenthening as well. 7 Subjects who have femur amputee for experimental group were able to ambulate naturally without inconvenience and 20 adult subjects of comparison group for comparison were considered to be free from disturbance of ambulation. The method of study was to measure the muscle power of hip pint, was to figure out the ratio of agonist & antagonist, concentric contraction & eccentric contraction, and was to find out mean and standard deviation of each measurement. Every numerical value of comparison was tested by Mann-whitney and comparison group's comparison between left & right value was done with t-test. Results are as followings : 1) Extension force was stronger than flexor force and had no remarkable difference(p<0.05) 2) For normal adults, adduction farce was stronger than abduction force and for amputees, abduction force was stronger while adduction force was the same as the normal without showing remarkable difference(p<0.05) According the result above, I make an assumption that maintaining a proper ratio of muscle power on strengthening exercise for amputee's ambulation training & rehabilitation and finally bring out an improvement of transfer and ambulation.

  • PDF

주관절 굴곡근의 근피로가 힘 재현 감각에 미치는 영향 (Influence of Muscle Fatigue on the Sensing of Force Reproduction in Elbow Flexors)

  • 이원휘;하성민;김용욱;오재섭
    • 한국전문물리치료학회지
    • /
    • 제14권3호
    • /
    • pp.16-22
    • /
    • 2007
  • The purpose of this study was to determine the influence of muscle fatigue in elbow flexors on the sense of force reproduction. Fifteen healthy subjects were recruited for this study. Maximum voluntary force (MVF) of elbow flexor muscles was measured by a digital tensiometer. Force errors were measured to test accuracy of the sense of force reproduction in elbow flexors. The subject was required to flex the elbow joint, to maintain and concentrate on about 20% of the MVF target force under visual feedback for 3 seconds. After a 5 second period rest, the subject was asked to duplicate the target force actively. Muscle fatigue was evoked with isometric contraction of the elbow flexors. Isometric contraction was continued until a 50% drop in MVF. The difference, in kilogram between the target force and the reproduced force was calculated for measuring force error. Force errors were compared between the non-fatigued condition and the fatigued condition by the paired t-test. Force errors were significantly increased in the fatigued condition compare to non-fatigued condition. This result suggests that the sense of force reproduction can be disturbed by localized muscle fatigue.

  • PDF

드롭랜딩 시 높이에 따른 슬개대퇴 압박력의 차이 (The Differences in Patellofemoral Compression Force with Different Height)

  • 조준행;김경훈;문곤성;이성철
    • 한국운동역학회지
    • /
    • 제21권3호
    • /
    • pp.335-343
    • /
    • 2011
  • Patellofemoral pain syndrome is the most common problem involving the knee, accounting for 25% of knee injuries. Repetitive, overuse activities cause increased force at the patellofemoral joint, resulting in pain during flexion and extension activities. Most research have been conducted in exploring the patellofemoral compressive force in gait, squat and lunges, even though in real cases, possibilities in landing exist. The purpose of this study was to compare the differences in patellofemoral compressive force according to two different height. Sixteen collegiate male students(age: 22.25 ${\pm}$ 3.30 yrs, height: 177.25 ${\pm}$ 4.44 cm, weight: 77.50 ${\pm}$ 8.18 kg) were chosen. The subjects performed drop landings in 45 cm, 60 cm. The findings demonstrated that higher height showed peak knee extension moment, quadriceps contraction force, patellofemoral compressive force with increased VGRF. Regarding the patellofemoral joint compressive force, it increased by quadriceps contraction force with knee flexion during landing, yet, it showed no difference in maximal knee flexion. To minimize patellofemoral joint stress and reduce the likelihood of developing PFPS, we recommend that predesigned quadriceps and hip muscle group strengthening are needed during conditioning and training.

교합기능시 흉쇄유돌근과 교근의 관계에 대한 근전도학적 연구 (AN INTEGRATED EMG STUDY OF THE RELATIONSHIP OF STERNOCLEIDOMASTOID AND MASSETER MUSCLES DURING OCCLUSAL FUNCTION)

  • 김교철;최부병
    • 대한치과보철학회지
    • /
    • 제27권2호
    • /
    • pp.37-52
    • /
    • 1989
  • The purpose of this study was to investigate the relationship between sternocleidomastoid (SCM) and masseter muscles during occlusal functions by means of EMG recordings of examined muscles. For the study, eighteen normal subjects were selected and the Bio-electric Processor EM2 (Myo-tronics Research, Inc., U.S.A.) with the surface electrodes was used to record the EMG activity from the right and left middle of masseter and insertion of SCM of each subject during right and left gum-chewing and isometric contraction by changing the biting force at right eccentric position of jaw. The amount of biting force ranged from 5 to 70kg during isometric contraction were measured by use of Jaw Force Meter. (Nihon Koden Kogyo, Japan.) The results were as follows: 1. The activity onset of SCM and masseter on the same side was almost at the same time, and integrated EMG values of two muscles on the chewing side were higher than the same named muscles on the non-chewing side during gum-chewing. (p<0.01) 2. The regression correlation was not present between both masseters (p>0.05), but between both SCM muscles or muscles of two kinds on the chewing or non-chewing side. ($p{\leqq}0.05$) 3. The integrated EMG value of SCM on chewing or non-chewing side were about 10 percent of that of ipsilateral masseter. 4. Mean voltage of each examined muscles were almost proportional to biting force during isometric contraction and the slope of voltage/biting force line was steepest at the ipsilateral masseter, followed by contalateral masseter, ipsi- and contra-lateral SCM muscles. 5. Mean voltage of ipsilateral masseter was highest during isometric contraction, followed by ipsilateral masseter, contra- and ipsi-lateral SCM muscles.

  • PDF

Role of Tyrosine Kinases in Vascular Contraction in Deoxycorticosterone Acetate-Salt Hypertensive Rats

  • Yeum, Cheol-Ho;Jun, Jae-Yeoul;Choi, Hyo-Sub
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제1권5호
    • /
    • pp.547-553
    • /
    • 1997
  • It has been known that activation of tyrosine kinases is involved in signal transduction. Role of the tyrosine kinase in vascular smooth muscle contraction was examined in deoxycorticosterone acetate (DOCA)-salt hypertensive rats. Male Sprague-Dawley rats underwent uninephrectomy, one week after which they were subcutaneously implanted with DOCA (200 mg/kg) and supplied with 1% NaCl and 0.2% KCl drinking water for $4{\sim}6$ weeks. Control rats were treated the same except for that no DOCA was implanted. Helical strips of carotid arteries were mounted in organ baths for measurement of isometric force development. Genistein was used as a tyrosine kinase inhibitor. Concentration-response curves to 5-hydroxytryptamine (5-HT) shifted to the right by genistein in both DOCA-salt hypertensive and control rats. Although the sensitivity to genistein was similar between the two groups, the maximum force generation by 5-HT was less inhibited by genistein in arteries from DOCA-salt hypertensive rats than in those from controls. Genistein-induced relaxations were attenuated in arteries from DOCA-salt rats. Genistein affected the contraction to phorbol 12, 13-dibutyrate (PDBu) neither in DOCA-salt nor in control arteries. These observations suggest that tyrosine kinase is involved in 5-HT-induced vascular contraction, of which role is reduced in DOCA-salt hypertension.

  • PDF

성견 상악 4절치의 Contraction과 압하시 치아 및 주위 조직의 조직학적 변화에 관한 실험 연구 (Histologic changes of tooth and periodontal tissues applying to contraction & intrusion force for the maxillary four incisors of dogs)

  • 김영국;차경석;이진우
    • 대한치과교정학회지
    • /
    • 제29권5호
    • /
    • pp.535-549
    • /
    • 1999
  • 본 연구는 Contraction Utility Arch wire를 이용하여 성견의 상악 4절치에 후방 견인력과 압하력을 2주와 4주간 적용하여 치아 및 치주 조직의 조직학적 변화를 관찰하여 생체에서 나타나는 생물학적인 효과와 작용의 진행과정을 확인하고자 시행되었다. 생후 약 10개월 정도의 성견 3 마리를 각각 실험군 2마리와 대조군 1 마리로 나누어 제 1, 2 절치에 1mm의 후방 견인력과 60gm의 압하력이 가해지도록 Contraction UTA를 삽입하였다. 장치 부착없이 2주후 희생시킨 것을 대조군으로, 장치 장착 2주후 희생시킨 것을 실험 1군으로, 장치 장착후 재활성화없이 4주후 희생시킨 것을 실험 2군으로 하여 각 군의 제 1, 2 절치에 대한 탈회 표본을 제작하여 Hematoxylin-Eosin염색과 Masson's Trichrome염색을 시행한 후, 각 치아의 치경부 l/3, 치근 중앙 1/3, 치근단 1/3의 치근 및 치아 주위 조직을 광학 현미경 하에서 관찰하여 다음의 결론을 얻었다. 1. 대조군 소견에서, 치주 인대는 치근단 부위에서 치조정까지 일정한 형태를 이루며 비교적 균일한 두께와 연속성을 나타내고 있었으며, 치조골 표면은 조골 세포와 함께 부드러운 골면을 이루고 있었다. 치근의 중앙부 및 치근단 부위에서는 세포성 백악질의 침착을 보였다. 2. 실험 1군의 제 1 절치에서, 치주 인대는 순설측 치경부에서 치근단 방향으로 신장되었다가 치근단부에서 압축되어 치조골에 평행하게 배열되는 소견을 보였으며, 치조골 흡수는 순측 치근 중앙부와 치근단부에서 활발히 진행되고 있었고 순측 치근단 부위의 치아면을 따라 백악질 흡수 부위가 산재되어 나타났다. 제 2 절치 역시 제 1 절치와 유사한 소견을 나타내고 있었으며 설측 치근단부에서 백악질 흡수 소와가 다수 관찰되었다. 3. 실험 2군의 제 1 절치에서,치주 인대의 주행 방향과 간격이 대조군 수준으로 회복되었으나, 치근단부에서는 여전히 혼재된 치주 인대 섬유의 주행이 관찰되었다. 설측 치근 중앙부에서 신생골의 석회화 반응이 강하게 관찰되었고, 순측 치근단부에서 골 흡수와 신생골 석회화가 진행중인 골 부위가 동시에 관찰되었다.

  • PDF

작약감초탕(芍藥甘草湯) 및 구성약물(構成藥物)이 기관지평골근(氣管支平滑筋)에 미치는 영향(影響) (Effects of Jakyakgamchotang Extract on the Trachea Smooth Muscle)

  • 국윤범;이장천;김희수
    • 대한한의학방제학회지
    • /
    • 제10권2호
    • /
    • pp.143-158
    • /
    • 2002
  • The purpose of the present study is to determine the effect of Jakyakgamchotang on histamine or acetylcholine induced tracheal smooth muscle contraction in rats and guinea pigs. Guinea pig(500g, male) and Sprague Dawley rats(250g, male) were killed by $CO_2$ exposure and a segment (4-5mm) of the thoracic trachea from each rat and guinea pig was cut into equal segments and mounted 'in pairs' in a tissue bath. Contractile force was measured with force displacement transducers under 0.5g loading tension. The dose of histamine(His) which evoked 50% of maximal response($ED_{50}$) was obtained from cumulative dose response curves for histamine($10^{-7}{\sim}10^{-4}M$). Contractions evoked by His($ED_{50}$) were inhibited significantly by Jakyakgamchotang. In guinea pig tracheal smooth muscle, the mean percent inhibition of histamine induced contraction was 90.8% (p〈0.001) after $100{\mu}l/ml$ Jakyakgamchotang. In rat tracheal smooth muscle, the mean percent inhibition of acetylcholine induced contraction was 22.1% (p〈0.05) after $100{\mu}l/ml$ Jakyakgamchotang. Propranolol indomethacin and methylene blue($10^{-7}M$) slightly but significantly attenuated the inhibitory effects of Jakyakgamchotang. These results indicate that Jakyakgamchotang can relax histamine or acetylcholine induced contraction of guinea pig and rat tracheal smooth muscle.

  • PDF

전기자극이 가해진 골격근의 피로항을 갖는 근육 모델의 구조 (A structure of musculotendon model with a fatigue profile of electrically stimulated skeletal muscle)

  • 임종광;남문현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.611-613
    • /
    • 1998
  • A structure of musculotendon model with a fatigue profile is investigated. The Hill-type musculotendon model can predicts the decline in muscle force for a given fatigue profile. It consists of nonlinear activation and contraction dynamics based on the physiological concepts. It is normalized for generalization to deal with the various muscles. Muscle force generated by continuous tetanic electrical monophasic pulsewidth modulation stimulation is decreased in time. A fatigue profile is expressed by a function of intramuscular acidification and applied to the relationship between muscle force and shortening velocity in contraction dynamics. The results of computer simulation are well matched with data in a literature which are isometrically performed for knee extension muscles. Also change in optimal fiber length has an effect only on muscle time, constant not on the steady-state tetanic force.

  • PDF

경량 의수용 SMA 구동식 생체모방 손가락 모듈 (SMA-driven Biomimetic Finger Module for Lightweight Hand Prosthesis)

  • 정성윤;문인혁
    • 제어로봇시스템학회논문지
    • /
    • 제18권2호
    • /
    • pp.69-75
    • /
    • 2012
  • This paper proposes a biomimetic finger module to be used in a lightweight hand prosthesis. The finger module consists of finger skeleton and an actuator module driven by SMA (Shape Memory Alloy). The prototype finger module can perform flexion and extension motions; finger flexion is driven by a contraction force of SMA, but it is extended by an elastic force of an extension spring inserted into the finger skeleton. The finger motions are controlled by feedback of electric resistance of SMA because the finger module has no sensors to measure length and angle. Total weight of a prototype finger module is 30g. In experiments the finger motions and finger grip force are tested and compared with simulation results when a constant contraction force of SMA is given. The experimental results show that the proposed SMA-driven finger module is feasible to the lightweight hand prosthesis.