• Title/Summary/Keyword: Continuous performance test

Search Result 484, Processing Time 0.04 seconds

Diagnostic Significance of Comprehensive Attention Test in Children and Adolescents with Attention-Deficit Hyperactivity Disorder (주의력결핍 과잉행동장애 아동에서 종합주의력검사의 진단적 유용성)

  • Seo, Jong-Man;Lee, Jung-Sun;Kim, Seong-Yoon;Kim, Hyo-Won
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.22 no.4
    • /
    • pp.246-252
    • /
    • 2011
  • Background : The objective of this study was to evaluate the diagnostic efficiency of the Comprehensive Attention Test (CAT) by comparing the results of the continuous performance test (CPT) and the CAT in children and adolescents with attention-deficit hyperactivity disorder (ADHD). Method : A total of 110 children and adolescents with ADHD (mean age : 11.2${\pm}$2.9 years, 76 boys) and 36 children and adolescents without ADHD (mean age : 12.0${\pm}$2.7 years, 25 boys) completed the CAT. We compared the specificity and sensitivity of the CPT and CAT at two different cut-off points via the McNemar test. The areas under the receiver operating characteristic curves (AUC) between the two groups were compared using Medcalc software. Results : The sensitivity and specificity of the CPT were .419 and .806, respectively. The sensitivity of the CAT was .827, which was significantly higher than that of the CPT (p<.001), and the specificity of CAT is .444, which was significantly lower than that of CPT (p<.001). The AUC of the CPT and CAT was .664 and .692, respectively, and there were no significant difference between the two groups on the paired comparison (p=.513). Conclusions : The results of this study suggest that the CAT has moderate specificity and high sensitivity. The CAT can be used as a useful tool to evaluate the neuropsychological function of children and adolescents with ADHD.

Flexural Performance and Cracking Resistance of Continuous Composite Slab using Micro Steel Fibers (마이크로 강섬유 콘크리트를 적용한 연속 합성슬래브의 휨 및 균열 저항성능)

  • Hwang, Hyeon-Jong;Park, Hong-Gun;Hong, Geon-Ho;Kim, Gap-Deug;Choi, Se-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.4
    • /
    • pp.387-397
    • /
    • 2015
  • In the present study, to enhance the constructability, a composite slab system using deck plate and micro steel fiber concrete was studied. In the proposed slab system, on-situ re-bar placement is not required. Steel fibers replace the temperature reinforcement. The present study focused on the crack control at the slab top in the continuous composite slab without spliced bars. Eight continuous slabs with various parameters were tested under vertical loading. The test parameters were the amount and types of micro steel fibers, types of deck plate, and the use of top bars in the continuous slab. To evaluate the crack resistance of the slabs, crack widths were measured in the continuous slabs. The test results showed that although the top spliced bars were not used, cracking were restrained by large flexural stiffness of the composite sections.

DEVELOPMENT OF A REVERSE CONTINUOUS VARIABLE DAMPER FOR SEMI-ACTIVE SUSPENSION

  • Yoon, Young-Hwan;Choi, Myung-Jin;Kim, Kyung-Hoon
    • International Journal of Automotive Technology
    • /
    • v.3 no.1
    • /
    • pp.27-32
    • /
    • 2002
  • Semi-active suspension systems are greatly expected to be in the mainstream of future controlled suspensions fur passenger cars. In this study, a continuous variable damper for a passenger car suspension is developed. It is controlled actively and exhibits high performance with light weight, low cost, and low energy consumption. To get fast response of the damper, reverse damping mechanism is adapted, and to get small pressure change rate after blow-off, a pilot controlled proportional valve is designed and analyzed. The reverse continuous variable damper is designed as a HS-SH damper which offers good body control with reduced transferred input force from tire, compared with any other type of suspension system. The damper structure is designed, so that rebound and compression damping force can be tuned independently, of which variable valve is placed externally. The rate of pressure change with respect to the flow rate after blow-offbecomes smooth when the fixed orifice size increases. Damping forces are measured with the change of the solenoid current at the different piston velocities to confirm the maximum hysteresis of 20N, linearity, and variance of damping farce. The damping farce variance is wide and continuous, and is controlled by the spoof opening, of which scheme is usually adapted in proportional valves. The reverse continuous variable damper developed in this study is expected to be utilized in the semi-active suspension systems in passenger cars after its performance and simplicity of the design is confirmed through real car test.

Experimental and numerical studies on cyclic behavior of continuous-tenon joints in column-and-tie timber construction

  • Qi, Liangjie;Xue, Jianyang;Xu, Dan
    • Structural Engineering and Mechanics
    • /
    • v.75 no.5
    • /
    • pp.529-540
    • /
    • 2020
  • The mechanical properties of timber construction have drawn more attention after the 2013 Lushan earthquake. A strong desire to preserve this ancient architectural styles has sprung up in recent years, especially for residential buildings of the mountainous areas. In the column-and-tie timber construction, continuous-tenon joints are the most common structural form to connect the chuanfang (similar to the beam in conventional structures) and the column. To study the cyclic performance of the continuous-tenon joints in column-and-tie timber construction, the reversed lateral cyclic loading tests were carried out on three 3/4 scale specimens with different section heights of the chuanfang. The mechanical behavior was assessed by studying the ultimate bending capacity, deformation ductility and energy dissipation capacity. Test results showed that the slippage of chuanfang occurred when the specimens entered the plastic stage, and the slippage degree increased with the increase of the section height of chuanfang. An obvious plastic deformation of the chuanfang occurred due to the mutual squeezing between the column and chuanfang. A significant pinching was observed on the bending moment-rotation curves, and it was more pronounced as the section height of chuanfang increased. The further numerical investigations showed that the flexural capacity and initial stiffness of the continuous-tenon joints increased with the increase of friction coefficient between the chuanfang and the column, and a more obvious increasing of bending moment occurred after the material yielding. The compressive strength perpendicular to grain of the material played a more significant role in the ultimate bending capacity of continuous-tenon joints than the compressive strength parallel to grain.

Structural Performance of Super-Deck Plate Slab System with Truss Type Bar (트러스근을 사용한 슈퍼데크 플레이트의 구조성능평가)

  • Kim, Seong-Soo;Kim, Sang-Shik;Lee, Woo-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.2
    • /
    • pp.193-199
    • /
    • 2003
  • This paper presents the results of an experimental research project on 7 Super Deck Plates with continuous or simple beam types. The test parameters included the distance of truss, depth of deck plate and the type of beam. The test results are as follows ; When thickness of deck plate was increased, maximum strength was improved When the distance of truss bar was reduced from 20cm to 15cm, the mean value of maximum load was increased to 1.21 times. Continuous beam shown superior to simple beam, such as 5.03 times high strength, low deflection at yield point.

The Effect of Food Service Organization Employee's Leaderships Type on Organizational Commitment and Managerial Performance: Focused on Busan Haeundae Area (외식업 종사자 리더십 유형이 조직몰입, 경영성과에 미치는 영향: 부산 해운대 지역을 중심으로)

  • Ahn, Gee-jung;Kim, Dong-gyu
    • Culinary science and hospitality research
    • /
    • v.23 no.5
    • /
    • pp.187-198
    • /
    • 2017
  • The purpose of the study was to investigate the relationships among leadership, organizational commitment and management performance of restaurant workers from the Busan Haeundae area. Normally, each leadership type(transactional leadership, transformational leadership, servant leadership) effected organizational commitment and management result. For the field test and verification, 200 staffs of the Haeundae restaurant participated in the survey from April 1st to May 30th, 2017. The research result was summarized as follows. First, all leadership types(transformational leadership, transformational leadership, servant leadership) of Haeundae restaurant staffs had a positive impact on affective involvement. Second, transformational leadership and transactional leadership of restaurant staffs had a positive influence on continuous commitment. Lastly, continuous commitment of restaurant staffs in Haeundae affected management result. In conclusion, precedent study explained only hotel investigation.

An Experimental Study on Performance and Exhaust Emission of a Heavy-Duty Engine with CR-DPF (CR-DPF를 장착한 대형디젤기관의 기관 및 배출가스성능에 관한 실험적 연구)

  • Kim mi soo;Oh sang ki;Han young chool
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.6
    • /
    • pp.114-118
    • /
    • 2004
  • This research focused on the principle and the development of continuous regeneration DPF technology which was the best particulate matters removing technology of current existing technologies owing to its superior comparability and possible applicability. In addition, there were some discussions about the affecting engine parameters such as engine driving conditions and the amounts, velocity, temperature, pressure of exhaust emissions as well as sulfur contents and lubricants which were prerequisites to prevent poisoning effect on catalysts. The test was made on an 8000cc heavy-duty turbo diesel engine on which continuous regeneration DPF was in order to investigate regeneration characteristics of DPF and me performance under the condition of standard or 50ppm low sulphur diesel. Exhaust emissions, CO, HC, NOx PM were measured and compared under D-13 modes.

Semi-Continuous Hidden Markov Model with the MIN Module (MIN 모듈을 갖는 준연속 Hidden Markov Model)

  • Kim, Dae-Keuk;Lee, Jeong-Ju;Jeong, Ho-Kyoun;Lee, Sang-Hee
    • Speech Sciences
    • /
    • v.7 no.4
    • /
    • pp.11-26
    • /
    • 2000
  • In this paper, we propose the HMM with the MIN module. Because initial and re-estimated variance vectors are important elements for performance in HMM recognition systems, we propose a method which compensates for the mismatched statistical feature of training and test data. The MIN module function is a differentiable function similar to the sigmoid function. Unlike a continuous density function, it does not include variance vectors of the data set. The proposed hybrid HMM/MIN module is a unified network in which the observation probability in the HMM is replaced by the MIN module neural network. The parameters in the unified network are re-estimated by the gradient descent method for the Maximum Likelihood (ML) criterion. In estimating parameters, the variance vector is not estimated because there is no variance element in the MIN module function. The experiment was performed to compare the performance of the proposed HMM and the conventional HMM. The experiment measured an isolated number for speaker independent recognition.

  • PDF

Design of User Concentration Classification Model by EEG Analysis Based on Visual SCPT

  • Park, Jin Hyeok;Kang, Seok Hwan;Lee, Byung Mun;Kang, Un Gu;Lee, Young Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.11
    • /
    • pp.129-135
    • /
    • 2018
  • In this study, we designed a model that can measure the level of user's concentration by measuring and analyzing EEG data of the subjects who are performing Continuous Performance Test based on visual stimulus. This study focused on alpha and beta waves, which are closely related to concentration in various brain waves. There are a lot of research and services to enhance not only concentration but also brain activity. However, there are formidable barriers to ordinary people for using routinely because of high cost and complex procedures. Therefore, this study designed the model using the portable EEG measurement device with reasonable cost and Visual Continuous Performance Test which we developed as a simplified version of the existing CPT. This study aims to measure the concentration level of the subject objectively through simple and affordable way, EEG analysis. Concentration is also closely related to various brain diseases such as dementia, depression, and ADHD. Therefore, we believe that our proposed model can be useful not only for improving concentration but also brain disease prediction and monitoring research. In addition, the combination of this model and the Brain Computer Interface technology can create greater synergy in various fields.

Case Studies on the Field Application of Miniature CPT's in South Korea (소형콘관입시험(Miniature CPT)의 국내현장적용 사례분석)

  • Yoon, Sung-Soo;Hwang, Dae-Jin;Kim, Jun-Ou;Ji, Wan-Goo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.269-281
    • /
    • 2010
  • The cone penetration test(CPT) has been increasingly used for in situ site characterization. However, the use of CPT is often limited due to specific site conditions depending on the cone size, geometry, and capacity of the CPT system used. In South Korea, it has generally been considered that the CPT could be satisfactorily performed only in soft soils. Louisiana State University/ Louisiana Transportation Research Center has implemented a field-rugged continuous intrusion miniature cone penetration test (CIMCPT) system since the 1990s. The miniature cone penetrometer of the CIMCPT system has a cross-sectional cone area of $2cm^2$ allowing finer soil profiles compared to the standard $10cm^2$. The reduced cross-sectional area also enables a system capacity reduction leading to cost saving and ease in maintenance. In addition, the continuous intrusion mechanism allows fast and economic site investigations. Samsung C&T Corporation has recently implemented a similar CIMCPT system. In this study, case studies on the field application of Samsung CIMCPT system for the last 2 years are presented to illustrate its performance investigation and its usefulness and limitation. Results of the case studies show that the CIMCPT system can be applied to soils with cone tip resistance($q_c$) values up to about 30MPa and allows a reliable and useful way to characterize soft soils. The results also show that the rod buckling limits the investigation depth by the system and the large contact pressure of the CIMCPT truck prevents the use of the system at sites with soft surface soils. According to the results of the case studies, the Samsung CIMCPT system has been being upgraded with a miniature cone with a longer rod, a crawler-type transportation system, a pre-boring system, and so on.

  • PDF