• Title/Summary/Keyword: Continuous performance test

Search Result 485, Processing Time 0.026 seconds

Evaluating Feeding of Organic Waste and Stirring Interval to Optimize Anaerobic Digestion

  • Kim, Gi-Woong;Kim, Sang-Hun
    • Journal of Biosystems Engineering
    • /
    • v.39 no.4
    • /
    • pp.366-376
    • /
    • 2014
  • Purpose: In the process of anaerobic digestion, stirring of the digester and feeding of organic waste into the digester have been considered important factors for digestive efficiency. The objective of this study was to determine the most appropriate conditions for both stirring interval of the digester and organic feeding frequency in order to improve anaerobic digestion performance. Methods: A 5-L anaerobic digester was used to conduct continuous batch tests to process swine manure and food waste. Four different stirring intervals of the digester were used: 5 min/h, 10 min/2 h, 15 min/3 h, and 20 min/4 h. Results: The application of swine manure to the digester every 5 min/h resulted in the highest production of biogas as well as the highest removal rates of volatile solids (VS) and total chemical oxygen demand. Stirring the digester with a mixture of swine manure and food waste at intervals of 5min/h and 10min/2 h produced the highest biogas yields of 515.3 mL/gVS and 521.1 mL/gVS, respectively. To test different supply frequencies, organic waste was added to the digester in either a 12-hor 24-h cycle. The 24-h cycle produced 1.5-fold greater biogas production than that during the 12-h cycle. Conclusions: Thus, from the above results, to optimize anaerobic digestion performance, the ideal stirring condition must be 5min/h for swine manure feeding and 10min/2h for co-digestion of food waste and swine manure in a 24-h cycle.

Development and Performance Evaluation of the First Model of 4D CT-Scanner

  • Endo, Masahiro;Mori, Shinichiro;Tsunoo, Takanori;Kandatsu, Susumu;Tanada, Shuji;Aradate, Hiroshi;Saito, Yasuo;Miyazaki, Hiroaki;Satoh, Kazumasa;Matsusita, Satoshi;Kusakabe, Masahiro
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.373-375
    • /
    • 2002
  • 4D CT is a dynamic volume imaging system of moving organs with an image quality comparable to conventional CT, and is realized with continuous and high-speed cone-beam CT. In order to realize 4D CT, we have developed a novel 2D detector on the basis of the present CT technology, and mounted it on the gantry frame of the state-of-the-art CT-scanner. In the present report we describe the design of the first model of 4D CT-scanner as well as the early results of performance test. The x-ray detector for the 4D CT-scanner is a discrete pixel detector in which pixel data are measured by an independent detector element. The numbers of elements are 912 (channels) ${\times}$ 256 (segments) and the element size is approximately 1mm ${\times}$ 1mm. Data sampling rate is 900views(frames)/sec, and dynamic range of A/D converter is 16bits. The rotation speed of the gantry is l.0sec/rotation. Data transfer system between rotating and stationary parts in the gantry consists of laser diode and photodiode pairs, and achieves net transfer speed of 5Gbps. Volume data of 512${\times}$512${\times}$256 voxels are reconstructed with FDK algorithm by parallel use of 128 microprocessors. Normal volunteers and several phantoms were scanned with the scanner to demonstrate high image quality.

  • PDF

Investigation of a Pseudo Capacitor with Polyacrylonitrile based Gel Polymer Electrolyte

  • Harankahawa, Neminda;Weerasinghe, Sandaranghe;Vidanapathirana, Kamal;Perera, Kumudu
    • Journal of Electrochemical Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.107-114
    • /
    • 2017
  • Pseudo capacitors belong to one group of super capacitors which are consisted with non carbon based electrodes. As such, conducting polymers and metal oxide materials have been employed for pseudo capacitors. Conducting polymer based pseudo capacitors have received a great attention due to their interesting features such as flexibility, low cost and ease of synthesis. Much work has been done using liquid electrolytes for those pseudo capacitors but has undergone various drawbacks. It has now been realized the use of solid polymer electrolytes as an alternative. Among them gel polymer electrolytes (GPEs) are in a key place due to their high ambient temperature conductivities as well as suitable mechanical properties. In this study, composition of a polyacrylonitrile (PAN) based GPE was optimized and it was employed as the electrolyte in a pseudo capacitor having polypyrrole (PPy) electrodes. GPE was prepared using ethylene carbonate (EC), propylene carbonate (PC), sodium thiocyanate (NaSCN) and PAN as starting materials. The maximum room temperature conductivity of the GPE was $1.92{\times}10^{-3}Scm^{-1}$ for the composition 202.5 PAN : 500 EC : 500 PC : 35 NaSCN (by weight). Performance of the pseudo capacitor was investigated using Cyclic Voltammetry technique, Electrochemical Impedance Spectroscopy (EIS) technique and Continuous Charge Discharge (GCD) test. The single electrode specific capacity (Cs) was found out to be 174.31 F/g using Cyclic Voltammetry technique at the scan rate of 10 mV/s and within the potential window -1.2 V to 1.2 V. The same value obtained using EIS was about 84 F/g. The discharge capacity ($C_d$) was 69.8 F/g. The capacity fade over 1000 cycles was rather a low value of 4%. The results proved the suitability of the pseudo capacitor for improving the performance further.

Preliminary Study of the Leaching Resistance of Boron from Borate Treated Wood by the Dual Treatment with Water-Repellent Preservative and Methyl Metacrylate (방부성(防腐性) 발수제(撥水劑)와 methyl metacrylate 이중처리(二重處理)에 의(依)한 붕소화합물(硼素化合物) 처리재(處理材)로부터 붕소(硼素)의 용탈(溶脫) 저항성(抵抗性)에 관(關)한 기초연구(基礎硏究))

  • Kim, Gyu-Hyeok;Ra, Jong-Bum
    • Journal of the Korean Wood Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.13-18
    • /
    • 1994
  • Sapwood samples of pitch pine were treated with disodium octaborate alone by dip-diffusion, or in combination with water-repellent preservative(WRP) and methyl metacrylate(MMA). Treated samples were subjected to an accelerated leaching test for determining the improvement of leaching resistance and to soft rot and mold tests for evaluating the increase in bioefficacy, due to the addition of WRP and MMA applied as a second treatment. The addition of WRP and MMA retarded leaching of boron to some extent from treated samples and this retardation can be explained by improved water repellency of WRP and MMA treated samples. Borate /WRP and borate /MMA systems will not qualify borate treated wood for ground and fresh water contact use but may improve performance of borate treated wood in above-ground applications not subjected to continuous wetting conditions. Bioefficacy against soft rot fungi and mold fungi was improved by a second treatment with WRP. However, improvement in the performance of borate /MMA systems was not observed. Considering improvement in both resistance of leaching and bioefficacy against micro fungi by the treatment of WRP and MMA, simultaneously, the dual treatment of borate treated wood by MMA containing co-biocides might be believed as an ideal treatment system.

  • PDF

A Study on Improving the Non-Combustible Properties of High-Density Fiber Cement Composites (고밀도 섬유 시멘트 복합체 불연특성 개선에 관한 연구)

  • Song, Tae-Hyeob;Jang, Kyong-Pil
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.521-528
    • /
    • 2021
  • The high-density fiber composite manufacturing method by the extrusion molding method has the characteristic that continuous production is possible, and the product is molded through a mold forming a specific cross-section. OPC is used as a defect material, an appropriate amount of SiO2 is supplied for CaO reaction activity, and high density and high strength are expressed through steam and autoclave curing. However, due to the use of organic reinforcing fibers, the flame duration exceeds the regulations during the non-combustible performance test, making it difficult to secure performance. In this study, the product was produced by mixing alkali-resistant organic fiber and fly ash having voids as a binder by replacing the existing polypropylene fiber. appeared to be possible.

A Study on Improving Plan of the Evaluating System for Efficient Defense M&S Accreditation Work (효율적인 국방M&S 인정업무 수행을 위한 평가시스템 발전방안 연구)

  • Han, Seung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.42-48
    • /
    • 2021
  • Recently, the defense industry has been improving high technology by developing convergence technology through the 4th industrial revolution. On the other hand, it is very difficult to guarantee the performance of high-tech weapon systems because the test for weapon systems has many risks and cannot perform in an actual operating environment. Therefore, M&S resources are needed to make sound weapon systems, but many people demand reliable M&S resources. Owing to the continuous demand and execution of the VV&A work, related rules have developed significantly, but tools and techniques for performing the work have not been developed. Hence, there are inefficient parts in the performance of work due to the absence of a systematic system. Accordingly, many risks may cause various safety accidents, such as security. This paper suggests a direction for the development of VV&A work procedures by improving efficiency and reducing risk.

RC Snubber Analysis for Oscillation Reduction in Half-Bridge Configurations using Cascode GaN (Cascode GaN의 하프 브릿지 구성에서 오실레이션 저감을 위한 RC 스너버 분석)

  • Bongwoo, Kwak
    • Journal of IKEEE
    • /
    • v.26 no.4
    • /
    • pp.553-559
    • /
    • 2022
  • In this paper, RC snubber circuit design technology for oscillation suppression in half-bridge configuration of cascode gallium nitride (GaN) field effect transistors (FETs) is analyzed. A typical wide band-gap (WBG) device, cascode GaN FET, has excellent high-speed switching characteristics. However, due to such high-speed switching characteristics, a false turn-off problem is caused, and an RC snubber circuit is essential to suppress this. In this paper, the commonly used experimental-based RC snubber design technique and the RC snubber design technique using the root locus method are compared and analyzed. In the general method, continuous circuit changes are required until the oscillation suppression performance requirement is met based on experimental experience . However, in root locus method, the initial value can be set based on the non-oscillation R-C map. To compare the performance of the two aforementioned design methods, a simulation experiment and a switching experiment using an actual double pulse circuit are performed.

Evaluation of SPACE Code Prediction Capability for CEDM Nozzle Break Experiment with Safety Injection Failure (안전주입 실패를 동반한 제어봉구동장치 관통부 파단 사고 실험 기반 국내 안전해석코드 SPACE 예측 능력 평가)

  • Nam, Kyung Ho
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.5
    • /
    • pp.80-88
    • /
    • 2022
  • The Korean nuclear industry had developed the SPACE (Safety and Performance Analysis Code for nuclear power plants) code, which adopts a two-fluid, three-field model that is comprised of gas, continuous liquid and droplet fields and has the capability to simulate three-dimensional models. According to the revised law by the Nuclear Safety and Security Commission (NSSC) in Korea, the multiple failure accidents that must be considered for the accident management plan of a nuclear power plant was determined based on the lessons learned from the Fukushima accident. Generally, to improve the reliability of the calculation results of a safety analysis code, verification is required for the separate and integral effect experiments. Therefore, the goal of this work is to verify the calculation capability of the SPACE code for multiple failure accidents. For this purpose, an experiment was conducted to simulate a Control Element Drive Mechanism (CEDM) break with a safety injection failure using the ATLAS test facility, which is operated by Korea Atomic Energy Research Institute (KAERI). This experiment focused on the comparison between the experiment results and code calculation results to verify the performance of the SPACE code. The results of the overall system transient response using the SPACE code showed similar trends with the experimental results for parameters such as the system pressure, mass flow rate, and collapsed water level in component. In conclusion, it can be concluded that the SPACE code has sufficient capability to simulate a CEDM break with a safety injection failure accident.

Comparison of educational activities and performance of dental hygiene and other healthcare students (치위생학과 학생과 보건의료계열 학생의 교육활동과 교육성과에 대한 비교)

  • Kim, Hoon;Hwang, Soo-Jeong
    • Journal of Korean Dental Hygiene Science
    • /
    • v.5 no.1
    • /
    • pp.39-45
    • /
    • 2022
  • Background: Dental hygienists undergo 3 or 4 years of college education, and dental hygienist education must receive continuous feedback through evaluation. The purpose of this study was to compare the educational performance of students from the Department of Dental Hygiene in 2018 with those from other departments in the healthcare field. Methods: We used data from the National Assessment of Student Engagement in Learning, conducted by the Korean Educational Development Institute in 2018. The survey data of 55 dental hygiene students and 60 healthcare students at K University were provided after excluding all identifying information. An independent t-test was used for comparisons between the Department of Dental Hygiene and other healthcare departments. Results: Regarding class-related activities, dental hygiene students were passive in presentations, discussions, and projects and had significantly lower grades in cooperative learning and challenging learning. Regarding extra-class activities, dental hygiene students had significantly lower global learning and external experiences, domestic experiences, club activities, and interactions with professors. Regarding learning outcomes, students had significantly lower grades in writing, speaking, critical and analytical thinking, data evaluation, understanding of data meaning, problem-solving ability, goal setting and execution, core content extraction, human and material resource utilization, creative convergence thinking, statistical understanding and analysis, information technology use, collaboration, sense of community, stress management, time management, and foreign language proficiency. Conclusions: Dental hygiene education requires innovation in educational methods and efforts of instructors to improve poor learning activities and outcomes.

A study on the data transmission performance for the development of the telesounder based on LTE communication system (LTE 통신 시스템 기반의 원격 어군탐지기 개발을 위한 데이터 전송 성능에 관한 연구)

  • HEO, Gyeom;HWANG, Doo-Jin;KANG, Tae-Jong;SHIN, Hyeon-Ok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.58 no.2
    • /
    • pp.153-158
    • /
    • 2022
  • A telesounder is a device that can monitor the appearance of fish in the sea on land and store fish detection data. This study was conducted to monitor the appearance of fish resources in coastal or near seas by using LTE communication for data transmission of the telesounder. The purpose of this study was to develop a prototype telesounder that can monitor the appearance of fish groups in the waters about 50 km away from the coast and store fish detection data. In this study, the prototype telesounder including a fish finder, communication device and battery for stable operation at sea was developed. The stability of telesounder buoy, data transmission/reception and expected use time were investigated. The expected use time of the telesounder using LTE communication with a lithium battery (12 V, 120 Ah) was about 274 hours under the conditions of 10 minutes off and 10 minutes on, about 520 hours under the conditions of 30 minutes off and 10 minutes on, and about 142 hours under continuous conditions. As a result of the sea test, it was found that the telesounder can be used in the sea area moved about 34 km from the land and the telesounder buoy was evaluated to have secured basic stability (buoyancy balance, waterproof, antenna strength, etc.) for operation in a marine environment.