• Title/Summary/Keyword: Continuous active motion

Search Result 23, Processing Time 0.031 seconds

The Effect of Continuous Passive Motion and Continuous Active Motion on Joint Proprioception After Total Knee Replacement (슬관절전치환술 후 연속수동운동(CPM)과 연속능동운동(CAM) 적용이 관절 고유수용감각에 미치는 영향)

  • Yang, Jin-Mo;Kim, Suhn-Yeop
    • Journal of Korean Physical Therapy Science
    • /
    • v.17 no.1_2
    • /
    • pp.41-52
    • /
    • 2010
  • Purpose: The purpose of this study was to compare the effects of continuous passive motion(CPM) and continuous active motion(CAM) on proprioception of the knee after total knee replacement(TKR). Methods: Twenty patients with TKR were randomly allocated into two groups, the CPM group(n=10) and the CAM group(n=10). All subjects were evaluated for levels of pain, passive range of motion and angle reproduction of the knee. An angle reproduction test was used to assess the proprioceptive deficit. Two types of angle reproduction test were used: a passive angle reproduction(PAR) test and an active angle reproduction(AAR) test. The relevant examinations were performed before and after intervention(on the 5th day and the 10th day). The statistical significance were calculated using a t-test and a one-way repeated ANOVA. Results: A pre-intervention significant difference was not found between the two groups. Significantly better results were before and after the intervention at 10 days, for the PAR(flexion direction) test; however, only in the CAM group. There were no significant difference, either before or after the intervention, for the AAR test(flexion and extension direction) in both group. Both groups experienced similar levels of pain and passive range of knee motion before and after the intervention. Conclusion: This study revealed that CAM was a better effect to restore position sense of the knee joint after TKR.

  • PDF

Human Face Tracking and Modeling using Active Appearance Model with Motion Estimation

  • Tran, Hong Tai;Na, In Seop;Kim, Young Chul;Kim, Soo Hyung
    • Smart Media Journal
    • /
    • v.6 no.3
    • /
    • pp.49-56
    • /
    • 2017
  • Images and Videos that include the human face contain a lot of information. Therefore, accurately extracting human face is a very important issue in the field of computer vision. However, in real life, human faces have various shapes and textures. To adapt to these variations, A model-based approach is one of the best ways in which unknown data can be represented by the model in which it is built. However, the model-based approach has its weaknesses when the motion between two frames is big, it can be either a sudden change of pose or moving with fast speed. In this paper, we propose an enhanced human face-tracking model. This approach included human face detection and motion estimation using Cascaded Convolutional Neural Networks, and continuous human face tracking and modeling correction steps using the Active Appearance Model. A proposed system detects human face in the first input frame and initializes the models. On later frames, Cascaded CNN face detection is used to estimate the target motion such as location or pose before applying the old model and fit new target.

The Effects of Auricular Electroacustimulation and Transcutaneous Electrical Nerve Stimulation on Postoperative Pain Control in Total Knee Replacement Patients (외이전기경혈자극과 경피전기신경자극이 슬관절 전 치환슬 환자의 수술 후 통증조절에 미치는 효과)

  • Kim, Tae-Youl;Hwang, Tae-Yeun;Huh, Choon-Bok
    • Journal of Korean Physical Therapy Science
    • /
    • v.1 no.1
    • /
    • pp.145-163
    • /
    • 1994
  • This study was done to determine differences in effect of postoperative pain control in patients receiving auricular electroacustimulation vs transcutaneous electrical nerve stimualtion following total knee replacement surgery. Thirty-one cases referred to physical therapy department after treated by total knee replacement surgery by orthopedic surgery department at the Pohang St. Mary's Hospital from January 1993 through June 1994. Of 31 total knee replacement cases, 13 cases were auricular electroacustimulation group, 11 cases were transcutaneous electrical nerve stimulation group, and 7 cases were control group. The results of the study summerized are as follows: Thirty-one total knee replacement cases(male in 12 cases, female in 19 cases), ranging in age from 34 to 61 years(mean${\pm}$SD=49.90 7.56) with diagnoses of degenerative arthritis(20 cases), rheumatoid arthritis(9 cases), and other(2 cases). In auricular electroacustimulation group, there was a significant change of pain intensity, unpleasantness, and active range of motion after treatment(p<0.01). In transcutaneous electrical nerve stimulation group, there was a significant change of pain intensity, unpleasantness, and active range of motion after treatment(p<0.01). In control group, did not show significant pre-posttreatment differences in pain intensity, unpleasantness, active range of motion(p>0.05). The mean change in pain intensity and unpleasantness, active range of motion from pretreatment baseline for the 3 groups. Auricular electroacustimulation group showed the large magnitude of increase in pain intensity and unpleasantness, active range of motion when compared to its own pretreatment cycle. Transcutaneous electrical nerve stimulation group showed small magnitude of increase in pain intensity and unpleasantness, active range of motion when compared to its own pretreatment cycle. No significant changes were observed in control group. Highly significant differences in pain intensity, unpleasantness, and active rage of motion were found using an ANOVA measures between treatment groups and control group(p<0.01). The squares correlation coefficients of pain and function measures pretreatment-posttreatment differences for each group. In treatment group, there was significant correlation between pain scale and function(p<0.001). In control group, there was no correlation between the pain scale and function (p>0.05). The continuous study is needd for many interesting issues of auricular electroacustimulation in new future.

  • PDF

Analysis of an Robust Control for a Vehicle Active Suspension System (차량 능동현가시스템에 대한 강인 제어 해석)

  • Kim, J.Y.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.7 no.3
    • /
    • pp.20-27
    • /
    • 2010
  • A vehicle suspension system performs two functions, the ride quality and the stability, which conflict with each other. An active suspension system has an external energy source, from which energy is always supplied to the system for continuous control of vehicle motion. Therefore, an active suspension system can have even more improved performance. Some control laws have been proposed for active suspension system, but in this paper, an optimal variable structure control(VSC) is proposed. The VSC method is well suited for a class of nonlinear system and can address the robustness issues to constant modelling errors and disturbances. This paper develops an optimal VSC controller and compares its performance to those of a passive suspension system and an active suspension system with an optimal controller. The transient and frequency responses are analyzed respectively.

  • PDF

Simple Postoperative Exercise of Acute Achilles Tendon Rupture without Active Range of Motion Exercise (아킬레스건 파열 이후의 능동적인 관절 범위 운동이 없는 간단한 재활 운동 방법)

  • Jae-Kwang Hwang;Youngjoo Jung;Dong-Kyo Seo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.27 no.1
    • /
    • pp.12-16
    • /
    • 2023
  • Purpose: Postoperative exercise for acute Achilles tendon rupture is important for a patient's return to daily life and sports. On the other hand, the protocol requires considerable effort to educate patients and continuous checking. This study evaluated the outcome of a new simple and delayed rehabilitation protocol after Achilles tendon rupture repair. Materials and Methods: From July 2014 to November 2020, one hundred eighty-three patients were operated on by one surgeon. The exercise protocol was classified into two methods. One group (immediate protocol, control group) started immediate full weight bearing with a 20° plantar flexion range of motion from two days postoperatively. Ankle dorsiflexion was restricted to 0°. The other group (delayed protocol, case group) started full weight bearing with a controlled ankle motion boot from two weeks postoperatively. No range of motion exercise was allowed until six weeks postoperatively. Age, sex, body mass index, ankle range of motion, muscle power, time to return to previous physical activity, functional score, and complication rate were evaluated. The results of the two groups were compared using a Mann-Whitney test. Statistical significance was set as p<0.05. Results: The range of motion, double heel rising, and one-leg standing were achieved faster in the control group (p<0.05). However, single-heel rising, repeated single-heel rising, return to previous activity (work, run, and sport), and functional scores showed no statistical difference (p>0.05). Conclusion: Simple and delayed postoperative rehabilitation of acute Achilles tendon rupture without active range of motion exercises showed satisfactory functional results and a low complication rate.

Arthroscopic Treatment of Post-traumatic Stiff Shoulder by Rotator Interval Bridging Scar Adhesion - Case Report - (회전근 개 간격의 가교 반흔 유착에 의한 외상성 견관절 강직증의 관절경적 치료 - 증례 보고 -)

  • Kim Young-Mo;Rhee Kwang-Jin;Kim Kyung-Cheon;Byun Byung-Nam
    • Clinics in Shoulder and Elbow
    • /
    • v.7 no.1
    • /
    • pp.41-45
    • /
    • 2004
  • In adhesive capsulitis of the shoulder of no response to nonoperative treatment, an arthroscopic capsular release and manipulation improves range of motion and pain relief. We performed an arthroscopic examination in the stiff shoulder, of which she had no response to nonoperative treatment, after the conservative treatment of a clavicular shaft fracture by motorcycle-driver traffic accident. We found the intra-articular 'rotator interval bridging scar adhesion' between subscapularis tendon and antero-superior glenoid fossa under the rotator interval which was no adhesion and contracture itself. We performed the scar adhesion removal and synovectomy, maintaining the rotator interval. We recommended nonsteroidal anti-inflammatory drug for postoperative pain relief and continuous active and passive range of motion (ROM) exercise to gain motions. Preoperatively, active and passive range of motion were 70° for forward elevation, 60° for abduction and especially 0° for external rotation. After postoperative 2 months, active ROM were 150° for forward elevation, 130° for abduction and 80° for external rotation. After postoperative 6 months, passive and active ROM were full. UCLA score improved from preoperative 9 points to postoperative 29 points.

Development of Reflected Type Photoplethysmorgraph (PPG) Sensor with Motion Artifacts Reduction (생명신호 측정용 반사형 광용적맥파 측정기의 움직임에 의한 신호왜곡 제거)

  • Han, Hyo-Nyoung;Lee, Yun-Joo;Kim, Jung-Sik;Kim, Jung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.12
    • /
    • pp.146-153
    • /
    • 2009
  • One of the most important issues in the wearable healthcare sensors is to minimize the motion artifacts in the vital signals for continuous monitoring. This paper presents a reflected type photoplethysmograph (PPG) sensor for monitoring heart rates at the artery of the wrist. Active noise cancellation algorithm was applied to compensate the distorted signals by motions with Least Mean Square (LMS) adaptive filter algorithms, using acceleration signals from a MEMS accelerometer. Experiments with a watch type PPG sensor were performed to validate the proposed algorithm during typical daily motions such as walking and running. The developed sensor is suitable for ubiquitous healthcare system and monitoring vital arterial signals during surgery.

A study on the variable damping characteristics of the continuous controlled semi-active suspension system and the effect analysis of the vehicles motion performance (연속제어방식의 반능동형 전자제어 현가장치의 가변댐퍼 감쇠력 특성 연구 및 차량 운동성능에 미치는 효과 분석)

  • 소상균;조경일
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.8
    • /
    • pp.190-198
    • /
    • 1999
  • Continuously controlled semi-active suspension system may improve ride and handling properties. Here, as a mechanism to control the fluid flow solenoid valve mechanism is introduced and added to the basic passive damper to create damping forces of the shock absorbers. The system may produce continuously controlled damping forces in both solenoid valve only and combination with passive shock absorber including fluid flow is studied, and then the combined model is added to the full vehicle model to evaluate its ride and handling performance. Finally, the simulation results are compared to the vehicle models having similar suspension system.

  • PDF

Development of an Ultra Precision Hydrostatic Guideway Driven by a Coreless Linear Motor

  • Park Chun Hong;Oh Yoon Jin;Hwang Joo Ho;Lee Deug Woo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.6 no.2
    • /
    • pp.55-60
    • /
    • 2005
  • In order to develop the hydrostatic guideways driven by a core less linear motor for ultra precision machine tools, a prototype of guideway is designed and tested. A coreless linear DC motor with a continuous force of 156 N and a laser scale with a resolution of 0.01 ㎛ are used in the system. Experimental analysis on the static stiffness, motion errors, positioning error and its repeatability, micro step response and velocity variation of the guideway are performed. The guideway shows infinite stiffness within 50 N applied load in the feed direction, and by the motion error compensation method using the Active Controlled Capillary, 0.08 ㎛ linear motion error and 0.1 arcsec angular motion error are acquired. The guideway also reveals 0.21 ㎛ positioning error and 0.09 ㎛ repeatability, and it shows stable responses following a 0.01 ㎛ resolution step command. The velocity variation of feeding system is less than 0.6 %. From these results, it is estimated that the hydrostatic guideway driven by a coreless linear motor is very useful for the ultra precision machine tools.

The Clinical Case Report about Postoperative Rehabilitation for the Tear of Anterior Cruciate Ligament Treated with Korean Medical Treatment and Continuous Passive Motion (한방 치료와 연속 수동 운동(CPM)을 병행한 전방 십자인대 파열 환자의 수술 후 재활 치료에 대한 증례 보고)

  • Park, Chang-Hyun;Song, Yun-Kyung
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.11 no.1
    • /
    • pp.97-107
    • /
    • 2016
  • Objectives : The objective of this study is to report the effect of Koran medical treatment and CPM exercise on recovery after reconstruction surgery of torn anterior cruciate ligament Methods : A 27-year-old male patient who had anterior cruciate ligament reconstruction surgery was treated by Korean medical treatment and CPM exercise from March 24th 2015 to April 16th 2015. Results : After treatments, VAS were generally decreased, ROM of Lt. knee got better from $95^{\circ}/10^{\circ}$(flexion/extension) to $120^{\circ}/-5^{\circ}$ (flexion/extension), Lysholm Score increased from 26 to 63. Conclusions : This study showed that Korean medical treatments and CPM exercise has meaningful effect on recovery after reconstruction surgery of anterior cruciate ligament. And it is considered that we need to apporoach recovery of these kinds of operation with more active Korean medical treatment, and further researches should be done steadily.

  • PDF