• Title/Summary/Keyword: Continuous Sensor

Search Result 586, Processing Time 0.023 seconds

Measurement System of Photosynthetic Photon Flux Distribution and Illumination Efficiency of LED Lamps for Plant Growth

  • Lee, Jae Su;Kim, Yong Hyeon
    • Journal of Biosystems Engineering
    • /
    • v.37 no.5
    • /
    • pp.314-318
    • /
    • 2012
  • Purpose: This study was conducted to develop a measurement system for determining photosynthetic photon flux (PPF) distribution and illumination efficiency of LED lamps. Methods: The system was composed of a linear moving sensor part (LMSP), a rotating part to turn the LMSP, a body assembly to support the rotating part, and a motor controller. The average PPF of the LED lamp with natural cooling and water cooling was evaluated using the measurement system. Results: The PPF of LED lamp with water cooling was 3.1-31.7% greater than that with natural cooling. Based on the measured value, PPF on the horizontal surface was predicted. Illumination efficiency of the LED lamp was slightly increased with water cooling by 3.4%, compared with natural cooling. A simulation program using MATLAB was developed to analyze the effects of the vertical distance from lighting sources to growing bed, lamp spacing, and number of LED lamps, on the PPF distribution on the horizontal surface. The uniformity of the PPF distribution of the LED lamps was fairly improved with 15 cm spacing, as compared to the 5 cm spacing. By simulation, PPF of $217.0{\pm}27.9{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ was obtained at the vertical distance of 40 cm from six LED lamps with 12 cm spacing. This simulated PPF was compared to the measured one of $225.9{\pm}25.6{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. After continuous lighting of 346 days, the relative PPF of LED lamps with water cooling and natural cooling was decreased by 6.6% and 22.8%, respectively. Conclusions: From these results, it was concluded that the measurement system developed in this study was useful for determining PPF and illumination efficiency of artificial lighting sources including LED lamp.

A Study on the Ground S/W Simulator for the Test of a Star Tracker (별센서 시험을 위한 지상 S/W 시뮬레이터 연구)

  • Lee, Hyeon Jae;Bang, Hyo Chung;Jeong, Dae Won;Seok, Byeong Seok;Kim, Hak Jeong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.5
    • /
    • pp.117-123
    • /
    • 2003
  • One of the most important elements in satellite attitude control is sensor technology. Generally, inertial sensors introduce drift and noise which cause continuous errors. Absolute reference is needed to eliminate the problem of the inertial sensors. Star trackers are used primarily for such a purpose. There has been relatively less research effort or ground feasibility test experience on star trackers in the domestic side despite the importance of the associated technologies. In this paper, we re-introduce the basic concept of a star tracker and present the S/W simulator for the star tracker. The star simulator may be used ground test of a star tracker for the basic functioning test or the whole spacecraft test with the star tracker assembled.

The Relationship between Oxygen Saturation and Color Alteration of a Compromised Skin Flap: Experimental Study on the Rabbit

  • Prasetyono, Theddeus O.H.;Adianto, Senja
    • Archives of Plastic Surgery
    • /
    • v.40 no.5
    • /
    • pp.505-509
    • /
    • 2013
  • Background The aim of this study was to collect important data on the time of oxygen saturation change in relation to skin flap color alteration using non-invasive pulse oximetry to evaluate its ability to provide continuous monitoring of skin flap perfusion. Methods An experimental study on the monitoring of blood perfusion of 20 tube-island groin flaps of 10 male New Zealand rabbits was performed using pulse oximetry. The animals were randomly assigned to one of two groups representing a blockage of either arterial or venous blood flow. The oxygen saturation change and clinical color alteration were monitored from the beginning of vessel clamping until the saturation became undetectable. The result was analyzed by the t-test using SSPS ver. 10.0. Results The mean times from the vessel clamping until the saturation became undetectable were $20.19{\pm}2.13$ seconds and $74.91{\pm}10.57$ seconds for the artery and vein clamping groups, respectively. The mean time of the clinical alteration from the beginning of vein clamping was $34.5{\pm}11.72$ minutes, while the alteration in flaps with artery clamping could not be detected until 2.5 hours after clamping. Conclusions The use of neonate-type reusable flex sensor-pulse oximetry is objective and effective in early detection of arterial and vein blockage. It provides real-time data on vessel occlusion, which in turn will allow for early salvaging. The detection periods of both arterial occlusion and venous congestion are much earlier than the color alteration one may encounter clinically.

A NEW METHOD - REAL TIME MEASUREMENT OF THE INITIAL DYNAMIC VOLUMETRIC SHRINKAGE OF COMPOSITE RESINS DURING POLYMERIZATION (복합레진의 초기 동적 체적 중합수축의 실시간 측정 -새로운 측정장치의 개발에 대한 소고-)

  • 이인복
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.2
    • /
    • pp.134-140
    • /
    • 2001
  • The polymerization shrinkage of composite resins is an important drawback although the composites have many advantages-more esthetic and conservative than metallic restoratives etc. The purposes of this research were to develop a new measurement method and to manufacture an instrument that can measure the initial dynamic volumetric shrinkage of composite resins during polymerization. The instrument was basically an electromagnetic balance that constructed with a force transducer using position sensitive photo detector(PSPD) and a negative feedback servo amplifier of proportional-derivative(PD) controller. The volumetric change of composites during polymerization was detected continuously as buoyancy change in distilled water by means of Archimedes's principle. It was converted to continuous electrical voltage signal in real time. The signal was properly conditioned and filtered and then it was stored in computer by a data acquisition(DAQ) board. By using this electronic instrument. the dynamic patterns of the polymerization shrinkage of eight commercial(Z-100, DenFil, AeliteFil, Z-250, P-60, SureFil, Synergy compact, and Tetric ceram) composite resins were measured and compared. The results were as follows. 1. From this project of developing instrument, the ability has been achieved that can acquire and process data of electrical signal transformed from various physical phenomenon by using temperature, displacement. photo. and force transducer. As a consequence, the instrumentation and measurement system used to analyze the physical characteristics of various dental materials in dental research field can be designed, manufactured and implemented in lab. 2. This instrument has some advantages. It was insensible to temperature change and could measure true dynamic volumetric shrinkage in real time without complicated process. It showed accuracy and high precision results with small standard deviation. 3. The polymerization shrinkage of composites was significantly different between brands and ranged from 2.47% to 3.89%, The order of polymerization shrinkage was as follows, in order of increasing shrinkage, SureFil, P60, Z250, Z100, Synergy compact. DenFil, Tetric ceram, and AeliteFil. 4. The polymerization shrinkage rate per unit time, dVol%/dt, showed that the instrument can provide an indirect research method for polymerization reaction kinetics.

  • PDF

Analysis of the risk of further oil spill from Sunken lanker, 'Kyung-Shin' (침몰 유조선 경신호의 추가 해양오염 가능성에 관한 연구)

  • Choi Hyuek-Jin;Byun Sung-Hoon;Lee Moon-Jin;Kang Chang-Gu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.5 no.4
    • /
    • pp.63-73
    • /
    • 2002
  • This paper presents the results of a ten-day long survey for assessing the possibility of further oil spillage from the sunken tanker, Kyung-Shin(995 G/T), which had sunken in the East Sea, off Pohang City, in February 1988. The survey was conducted using remotely operated vehicle(ROV), manned submersible and ultrasonic thickness gauge in September 2001. The external inspection by the optical camera shows that small scale oil spill has been continued from the sunken ship. It's hull thickness was also measured at several points of the ship, using an ultrasonic sensor for assessing the current corrosion status of the sunken ship. Taking into account the results of this survey and the existing salvage report, it is estimated that the remaining oil in the tanker is approximately 600 ㎘, and this oil could be leaked into marine environment due to continuous severe corrosion if no preventive is taken.

  • PDF

Filtering Method for Analyzing Renewable Energy Stream Data (신재생 에너지 스트림 데이터 분석을 위한 필터링 기법)

  • Jin, Cheng Hao;Li, Xun;Kim, Kyu Ik;Hwang, Mi Yeong;Kim, Sang Yeob;Kim, Kwang Deuk;Ryu, Keun Ho
    • Journal of Convergence Society for SMB
    • /
    • v.1 no.1
    • /
    • pp.39-44
    • /
    • 2011
  • Recently, due to people's incontinent use all over the world, fossil fuels such as coal, oil, and natural gas were nearly to be exhausted and also causes serious environment pollutions. Therefore, there is a strong need to develop solar, wind, hydro, biomass, geothermal to replace fossil fuels to prevent suffering from above problems. Wish advances in sensor technology, such data is collected as a kind of stream data which arrives in an online manner so that it is characterized as high- speed, real-time and unbounded and it requires fast data processing to get the up-to-date results. Therefore, the traditional data processing techniques are not fit to deal with stream data. In this paper, we propose a kalman filter-based algorithm to process renewable stream data.

  • PDF

FMCW Radar simulation model with interference using a new radar performance parameter (새로운 레이더 성능지표를 이용한 FMCW 레이더 간섭 시뮬레이션 모델)

  • Mun, Sang-Kon;Park, Seung-Keun;Yang, Hoon-Gee;Cheon, Chang-Yul;Chung, Young-Seek;Bae, Kyung-Bin
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.4
    • /
    • pp.86-92
    • /
    • 2011
  • ITS(Intelligent Transport System) has been researched actively to guarantee the smooth traffic and the safety of the vehicle. In recent, as the sensor for the measurement of distance between vehicles, the FMCW radar system in millimeter wave band has been interested in ITS. Actually, 47, 60, 77, 94 and 139 GHz have been assigned for the vehicle radar frequencies in Europe and Japan. However, the performances of the FMCW radar are deteriorated due to the interferences from the surrounding radars and mobile devices. In this paper, in order to model and simulate the performance of FMCW radar under the exterior interference, we propose a new performance parameter, RER(Radius Error Rate), which contains the information of the range error due to the interferences, and show the effectiveness of the proposed parameter.

Application of Combined-Type Sensors for the Behavioral Measurement of Concrete Beams (콘크리트 보의 거동 측정을 위한 조합형 센서의 활용)

  • Kim, Yun-Tae;Kim, Sang-Chel
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.3
    • /
    • pp.454-461
    • /
    • 2003
  • This study addressed a procedure to carry out an experimental study on a behavior of simple and continuous concrete beams. For this purpose, sample concrete beams were fabricated and sensors for the measurement of strains and deflections were attached both on the surface of the beams and inside them. Two types of sensors were used to measure strains associated with loading: electric resistance strain sensors and fiber optic sensors. Displacement gauges were also attached on the bottoms of beams to investigate the behavior of beams more rationally. The behavior of the beams was then evaluated throughout the results measured from different sensors while they were subject to steady loading up to failure. From results of this study, it was found that concurrent use of sensors and displacement gauges is helpful in investigating the behavior of concrete beams more effectively. Especially, combined-type strain sensors specifically fabricated in this experiment were found not to be affected by the occurrence of cracks so significantly and to be very effective in monitoring strains of concrete structure. It was also observed that beams show nonlinear force-displacement relationship and reinforcing bars take charge of resisting the external force once cracks occur in concrete beams.

An Extraction Method of Meaningful Hand Gesture for a Robot Control (로봇 제어를 위한 의미 있는 손동작 추출 방법)

  • Kim, Aram;Rhee, Sang-Yong
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.27 no.2
    • /
    • pp.126-131
    • /
    • 2017
  • In this paper, we propose a method to extract meaningful motion among various kinds of hand gestures on giving commands to robots using hand gestures. On giving a command to the robot, the hand gestures of people can be divided into a preparation one, a main one, and a finishing one. The main motion is a meaningful one for transmitting a command to the robot in this process, and the other operation is a meaningless auxiliary operation to do the main motion. Therefore, it is necessary to extract only the main motion from the continuous hand gestures. In addition, people can move their hands unconsciously. These actions must also be judged by the robot with meaningless ones. In this study, we extract human skeleton data from a depth image obtained by using a Kinect v2 sensor and extract location data of hands data from them. By using the Kalman filter, we track the location of the hand and distinguish whether hand motion is meaningful or meaningless to recognize the hand gesture by using the hidden markov model.

New Control Method for Power Decoupling of Electrolytic Capacitor-less Photovoltaic Micro-Inverter with Primary Side Regulation

  • Irfan, Mohammad Sameer;Shin, Jong-Hyun;Park, Joung-Hu
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.677-687
    • /
    • 2018
  • This paper presents a novel power decoupling control scheme with the bidirectional buck-boost converter for primary-side regulation photovoltaic (PV) micro-inverter. With the proposed power decoupling control scheme, small-capacitance film capacitors are used to overcome the life-span and reliability limitations of the large-capacitance electrolytic capacitors. Then, an improved flyback PV inverter is employed in continuous conduction mode with primary-side regulation for the PV power conditioning. The proposed power-decoupling controller shares the reference for primary side current regulation of the flyback PV inverter. The decoupling controller shapes the input current of the bidirectional buck-boost converter. The shared reference eliminates the phase-delay between the input current to the bidirectional buck-boost converter and the double frequency current at the PV primary current. The elimination of the phase-delay in dynamic response enhances the ripple rejection capability of the power decoupling buck-boost converter even with small film capacitor. With proposed power decoupling control scheme, the additional advantage of the primary-side regulation of flyback PV inverter is that there is no need to have an extra current sensor for obtaining the ripplecurrent reference of the decoupling current-controller of the power-decoupling buck-boost converter. Therefore, the proposed power decoupling control scheme is cost-effective as well as the size benefit. A new transient analysis is carried out which includes the source voltage dynamics instead of considering the source voltage as a pure voltage source. For verification of the proposed control scheme, simulation and experimental results are presented.