• 제목/요약/키워드: Continuous Conduction Mode(CCM)

검색결과 58건 처리시간 0.023초

이산 시간 영역 해석에 기반한 벅 AC/DC LED 구동기의 슬로프 보상 설계 (Slope Compensation Design of Buck AC/DC LED Driver Based on Discrete-Time Domain Analysis)

  • 김만고
    • 전력전자학회논문지
    • /
    • 제24권3호
    • /
    • pp.207-214
    • /
    • 2019
  • In this study, discrete-time domain analysis is proposed to investigate the input current of a buck AC/DC light-emitting diode (LED) driver. The buck power factor correction converter can operate in both discontinuous conduction mode (DCM) and continuous conduction mode (CCM). Two discontinuous and two continuous conduction operating modes are possible depending on which event terminates the conduction of the main switch in a switching cycle. All four operating modes are considered in the discrete-time domain analysis. The peak current-mode control with slope compensation is used to design a low-cost AC/DC LED driver. A slope compensation design of the buck AC/DC LED driver is described on the basis of a discrete-time domain analysis. Experimental results are presented to confirm the usefulness of the proposed analysis.

전류연속모드 승압형 컨버터의 효율 분석에 관한 연구 (A Study on the efficiency analysis of CCM boost converter)

  • 배진용;김용;이은영;권순도;조규만;엄태민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.920-921
    • /
    • 2008
  • This paper presents the efficiency analysis of CCM(Continuous Current Mode) boost converter. A thorough efficiency analysis of a boost converter taking into account the conduction losses, the diode power loss, the switching losses, the gate-drive loss and the capacitive switching loss, for both continuous conduction mode is presented.

  • PDF

Interleaved 부스트 컨버터에서 단일 공진 인덕터를 이용한 소프트 스위칭 기법 (A Soft Switching Scheme using a Single Resonant Inductor in Interleaved Boost Converter)

  • 박남주;이동명;하동현;현동석
    • 전력전자학회논문지
    • /
    • 제13권4호
    • /
    • pp.263-269
    • /
    • 2008
  • 본 연구에서는 연속도통모드에서 단일 공진 인덕터를 사용하여 ZVT를 갖는 interleaved 부스트 컨버터를 제안한다. ZVT셀을 가지는 제안된 ZVT가지는 Interleaved 부스트 컨버터는 간단한 회로를 가지며 필터 사이즈 감소와 저 비용이 가능하다는 장점을 가진다. 또한 고 전력 응용에 적합하다. 본 논문에서 제안된 ZVT 가지는 IBC의 회로와 동작 원리를 자세히 설명하였다. 그리고 제안된 ZVT 기법의 타당성은 실험을 통하여 검증하였다.

단상 브리지리스 배전압 변환기의 역률 개선에 관한 연구 (A Study on the Power Factor Improvement of Single-Phase Bridgeless Voltage Doubler Converter)

  • 구도연;김동욱;임승범;홍순찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.169-170
    • /
    • 2011
  • PFC(Power Factor Correction) converters are commonly designed for CCM(Continuous Conduction Mode). However, DCM(Discontinuous Conduction Mode) appears in the input current near the ZCP(Zero Crossing Point) at light loads, resulting in input current distortion. It is caused by inaccurate average current values obtained in DCM. This paper studies a simple digital control scheme that can be operated in both CCM and DCM with minimal changes to the CCM average current control structure.

  • PDF

Investigating Buck DC-DC Converter Operation in Different Operational Modes and Obtaining the Minimum Output Voltage Ripple Considering Filter Size

  • Babaei, Ebrahim;Mahmoodieh, Mir Esmaeel Seyed;Sabah, Mehran
    • Journal of Power Electronics
    • /
    • 제11권6호
    • /
    • pp.793-800
    • /
    • 2011
  • This paper investigates the operational modes of buck dc-dc converters and their energy transmission methods. The operational modes of such converters are classified in two types, discontinuous conduction mode (DCM) and continuous conduction mode (CCM). In this paper, the critical inductance relation of DCM and CCM is determined. The equations of the output voltage ripple (OVR) for each mode are obtained for a specific input voltage and load resistance range. The maximum output voltage ripple (MOVR) is also obtained for each mode. The filter size is decreased and the minimum required inductance value is calculated to guarantee the minimization of the MOVR. The experimental and simulation results in PSCAD/EMTDC prove the correctness of the presented theoretical concepts.

High Efficiency Design Considerations for the Self-Driven Synchronous Rectified Phase-Shifted Full-Bridge Converters of Server Power Systems

  • Cetin, Sevilay
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.634-643
    • /
    • 2015
  • This paper presents a high frequency design approach for improving efficiency over a wide load range in the self-driven phase-shifted full-bridge converters for server power systems. In the proposed approach, a detailed ZVS analysis of the lagging leg switches in both the continuous conduction mode (CCM) and the discontinuous conduction mode (DCM) is presented. The optimum dead time and the determination of the appropriate operation mode are given for high efficiency according to the load conditions. Finally, the optimum operation conditions are defined to achieve a high-efficiency. A laboratory prototype operating at 80 kHz, rated 1 kW (12 V-83.3 A), is built to verify proposed theoretical analysis and evaluations. The experimental results show that the maximum efficiency is achieved as 95% and 83.5% at full load and 5% load conditions, respectively.

듀얼모드 제어를 통한 DC/DC 위상천이 풀브릿지 컨버터의 과도상태 개선 (A Dual-Mode Control of DC/DC Phase-Shift Full-Bridge Converter for Transient Response Improvement)

  • 이선호;이현우;장유남;김이삭;박정욱
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2020년도 전력전자학술대회
    • /
    • pp.261-262
    • /
    • 2020
  • 본 논문은 DC/DC 위상천이 풀브릿지 컨버터의 과도상태 개선을 위한 듀얼모드 제어를 제안한다. 기존의 discontinuous conduction mode (DCM)과 continuous conduction mode (CCM)을 이용하여 운용하는 위상천이 풀브릿지 컨버터는 각 모드의 상이한 전압게인의 특성을 고려하지 않아 급격한 로드 변동시 출력 전압의 언더슈트 혹은 오버슈트가 크게 발생한다. 제안하는 듀얼모드 제어는 DCM과 CCM 각 모드 별개로 제어가 적용되고 출력 전류의 변화에 대응하는 적응형 feed-forward 제어가 적용되어 컨버터의 과도상태를 개선할 수 있다. 듀얼모드의 제어 방법의 성능과 타당성을 시뮬레이션을 통해 입증한다.

  • PDF

경부하에서 위상천이 풀브릿지 DC-DC 컨버터의 동작 분석 (Analysis of DC-DC Phase-Shifted Full-Bridge Converter in Light Load Condition)

  • 이선호;박정욱
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.430-431
    • /
    • 2018
  • DC-DC 위상천이 풀브릿지 컨버터는 경부하 운용시에 영전압 스위칭이 발생하지 않아 큰 스위칭손실이 발생한다. 경부하에서 위상천이 풀브릿지 컨버터의 낮은 효율을 개선하기 위해 DCM (Discontinuous Conduction Mode) 동작을 이용한다. 본 논문은 경부하에서 위상천이 컨버터의 DCM과 CCM (Continuous Conduction Mode) 동작의 특성 및 도통 손실 절감을 위한 동기 정류기의 제어 방법을 이론적으로 분석하고, 시뮬레이션을 통해 검증하였다.

  • PDF

소프트 스위칭 기법을 적용한 싱크로너스 양방향 DC-DC 컨버터 (Synchronous Bidirectional DC-DC Converter Applying Soft-Switching Technique)

  • 이동규;박남주;현동석
    • 전력전자학회논문지
    • /
    • 제13권4호
    • /
    • pp.311-318
    • /
    • 2008
  • 본 논문은 소프트 스위칭 기법을 적용한 싱크로너스 양방향 DC-DC 컨버터를 제안한다. 제안된 컨버터는 싱크로너스 벅 컨버터를 병렬구성을 하여 인터리브드 기법을 통해 도통 손실을 줄이고, 하나의 공진인덕터를 사용한 ZVT-Cell을 적용함으로써 스위칭 손실을 최소화 하였다. 전 부하 범위에서 CCM(Continuous Conduction Mode) 으로 동작하고 ZVS가 성립되도록 하였으며, 전류주입 기법을 통해 넓은 출력전압 범위에서도 ZVS 조건을 만족하였다. 또한, 기존 싱크로너스 벅 컨버터의 데드타임(dead time)동안 발생하는 역병렬 다이오드의 도통손실 및 dv/dt, di/dt 발생을 저감하는 효과를 얻을 수 있다. 제안된 컨버터의 유효성은 실험을 통해서 검증하였다.

저궤도 인공위성용 태양전력 조절기의 전류 불연속 모드 해석 (DCM Analysis of Solar Array Regulator for LEO Satellites)

  • 박희성;차한주
    • 전기학회논문지
    • /
    • 제65권4호
    • /
    • pp.593-600
    • /
    • 2016
  • The solar array regulator for low earth orbit satellites controls a operating point of solar array for suppling electric power to the battery and the other units. Because the control object is reversed, the new approach for large and small signal analysis is needed despite using buck-converter for power stage. In this paper, the steady state analysis of solar array regulator is performed in continuous conduction mode and discontinuous conduction mode, and the border condition for each mode is established. Also, the small signal model of solar array regulator is established in discontinuous conduction mode. Experiments are carried on in worst condition which the solar array regulator can face with discontinuous conduction mode. The results show that the solar array regulator is in stable.