• 제목/요약/키워드: Contamination monitoring

검색결과 506건 처리시간 0.026초

중금속으로 오염된 포화사질토의 저주파대에서의 유전특성

  • 방선영;오명학;김용성;박준범
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.289-292
    • /
    • 2003
  • Laboratory tests were performed to investigate the dielectric property of saturated sands contaminated by heavy metals solution at low frequency. Differences of contamination and the real part of dielectric constant depend on heavy metal concentration was measured at low frequency, 100KHz below. The optimal frequency to develop the detection potentials of monitoring was 1KHz, 10KHz, 100KHz. At this frequency, Heavy metal contamination of saturated sands contamination can be recommended by analysis of complex dielectric constant.

  • PDF

MODFLOW를 이용한 유류오염지역 지하수 유동 및 오염물질 이동 평가

  • 전권호;문철환;이진용;이재영
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.536-539
    • /
    • 2003
  • This study area has been contaminated by oils. To identify contaminated ranges and to assess the possibility of contamination dispersion, monitoring wells were installed and slug test, field soil permeability test, automatic or manual measurement of groundwater table, and groundwater quality analyses in field and laboratory were performed. In addition, a groundwater modeling program was used to assess the possibility of oil contamination dispersion, based on field data and groundwater quality data. The results showed that concentration of oil contaminants in groundwater have been decreased by dispersion and adsorption.

  • PDF

치과 진료실의 미생물 오염도에 대한 4차 암모늄 화합물의 효과 (Effect of quaternary ammonium compounds on microbial contamination levels in dental clinics)

  • 백세연;박연정;최승호;김희재;김성택
    • 구강회복응용과학지
    • /
    • 제36권1호
    • /
    • pp.55-60
    • /
    • 2020
  • 물리적 항균효과를 나타내는 4차 암모늄 화합물을 치과 진료실 미생물 주요 오염 구역에 도포 후 시기별 오염도의 변화를 측정하고자 하였다. 4개의 국내외 치과병의원에서 미생물 감염이 쉬운 유닛체어 핸들, 타구대 표면, 핸드피스 거치대 등에 ATP (adenosine triphosphate) 모니터링 시스템과 ATP 표면검사 테스트 키트를 사용하여 항균제 도포 전과 후 시기별 오염도를 비교 측정하였다. 4차 암모늄 화합물 도포 전 구역별 미생물 오염도는 치과의사가 주로 사용하는 핸드피스 거치대가 가장 높았다. 도포 후 시기별 오염도의 변화를 분석한 결과 대부분의 진료실에서 현저한 오염도의 감소를 보였으며, 대략 4-6개월 정도 효과가 지속되는 양상을 보였다. 항균효과의 지속성과 최소량의 화학성분 노출이라는 장점으로 향후 대단위 후속연구를 통해 4차 암모늄 화합물이 치과 진료실에서 효과적으로 사용될 수 있을 것으로 기대된다.

센서 네트워크를 이용한 수질 감시 원격 시스템 (Remote Sur-veillance network system for water contamination using Sensor network)

  • 곽호협;박세현;박세훈;김응수
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2008년도 춘계종합학술대회 A
    • /
    • pp.865-868
    • /
    • 2008
  • 센서 네트워크를 이용한 수질 감시 시스템을 설계하였다. 무선 센서 네트워크는 강과 같은 넓은 지역의 수질 오염을 모니터링 하는데 효과적인 해결책 중 하나다. 기존의 수질 감시 원격 시스템은 설치비용, 새로운 노드의 추가 및 결함이 있는 노드의 교체 등에 문제가 있다. 제안된 시스템은 기존 시스템에 비해 경제적으로 효과 있는 해결책을 가진다.

  • PDF

Assessment of groundwater contamination susceptibility based on water chemistry data - A review

  • Kim, Kang-Joo;Natarajan Rajmohan;Chae, Gi-Tak;Yun, Seong-Taek
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.12-15
    • /
    • 2004
  • Groundwater contamination susceptibility studies have many advantages in groundwater monitoring, management and future planning. Several methods have been developed and applied to the groundwater regime through out the world. However, each and every method has some limitations. In this study, a detailed review was carried out about the already existing methods for groundwater contamination susceptibility studies. Additionally, a new parameter called mineral dissolution factor is recommended for groundwater contamination susceptibility studies. This parameter is applied for groundwate contamination susceptibility studies in Namwon area, Korea. The result of this approach suggests that mineral dissolution parameter could overcome the limitations as observed in the earlier methods.

  • PDF

토양오염방지를 위한 지하저장탱크의 관리 방안 연구 (Management Criteria of Underground Strage Tank for Prevention of Soil Contamination)

  • 김준현;한영한
    • 산업기술연구
    • /
    • 제18권
    • /
    • pp.453-460
    • /
    • 1998
  • The purpose of this study was to analyze their status of underground storage tank(UST) facilities and level of soil contamination, and to establish its management criteria. DB program was developed to analyze the correlation between specific characteristic of UST and level of soil contamination. For a suitable management of UST, leakage monitoring and inspection method of UST was investigated. Inspection period was established based on the leakage rate. The most dominant factor for leakage seemed to be caused by the corrosion. Therefore, main factor, construction method and installation year of UST, and corrosion protection system were suggested for optimal protection of UST. Considering the present management status of UST in Korea, inspection and management criteria of UST should be accomplished in term of contamination protection of leakage, and flexible regulation act should be introduced for each specific site.

  • PDF

수질 측정용 플로우 셀의 오염 모니터링을 위한 평면광도파로 센서 (PLC Optical Sensor for Contamination Monitoring on the Flow-Cell in the Water Quality Measurement System)

  • 한승헌;김태언;정행윤;기현철;김두근;김선훈
    • 한국전기전자재료학회논문지
    • /
    • 제32권6호
    • /
    • pp.472-476
    • /
    • 2019
  • We have proposed a novel planar lightwave circuit (PLC) optical sensor to monitor the contamination in a flow-cell where water is continuously supplied through a water quality measurement system. We designed a PLC chip with a V-shape waveguide and the simulated its function as a sensor for monitoring contamination in a flow-cell using a numerical the FDTD (finite-difference time-domain) analysis. A novel cross type of waveguide was introduced to make the PLC chip of the V-shaped waveguide. The fabricated PLC was cut into the cross waveguide. A change in the optical propagation loss of the PLC sensor was observed after immersing the PLC sensor into city water. It was determined that the propagation loss of the PLC sensor was 3 dB at a wavelength of $1.55{\mu}m$ in the city water for 15 days.

오염 지중환경 특성화와 자연저감평가를 위한 말단전자수용과정(TEAPs) 분석 및 평가기술 소개 (Review of Analytical and Assessment Techniques of Terminal Electron Accepting Processes (TEAPs) for Site Characterization and Natural Attenuation in Contaminated Subsurface Environments)

  • 송윤선;김한석;권만재
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제25권2_spc호
    • /
    • pp.1-15
    • /
    • 2020
  • Monitoring and assessing terminal electron accepting processes (TEAPs) are one of the most important steps to remediate contaminated sites via various in-situ techniques. TEAPs are a part of the microbial respiration reactions. Microorganisms gain energy from these reactions and reduces pollutants. Monitoring TEAPs enables us to predict degradability of contaminants and degradation rates. In many countries, TEAPs have been used for characterization of field sites and management of groundwater wells. For instance, US Environmental Protection Agency (EPA) provided strategies for groundwater quality and well management by applying TEAPs monitoring. Denmark has also constructed TEAPs map of local unit area to develop effective groundwater managing system, particularly to predict and assess nitrogen contamination. In case of Korea, although detailed soil survey and groundwater contamination assessment have been employed, site investigation guidelines using TEAPs have not been established yet. To better define TEAPs in subsurface environments, multiple indicators including ion concentrations, isotope compositions and contaminant degradation byproducts must be assessed. Furthermore, dissolved hydrogen concentrations are regarded as significant evidence of TEAPs occurring in subsurface environment. This review study introduces optimal sampling techniques of groundwater and dissolved hydrogen, and further discuss how to assess TEAPs in contaminated subsurface environments according to several contamination scenarios.

기계 상태진단을 위한 인-라인형 오일 모니터링 스마트 센서 (In-line Smart Oil Sensor for Machine Condition Monitoring)

  • 공호성;오씨아빅터;한흥구;류보브마르코바
    • Tribology and Lubricants
    • /
    • 제24권3호
    • /
    • pp.111-121
    • /
    • 2008
  • An integrated in-line oil monitoring detector assigned for continuous in situ monitoring multiple parameters of oil performance for predicting economically optimal oil change intervals and equipment condition control is presented in this study. The detector estimates oil deterioration based on the information about chemical degradation, total contamination, water content of oil and oil temperature. The oil oxidation is estimated by "chromatic ratio", total contamination is measured by the changes in optical intensity of oil in three optical wavebands ("Red", "Green" and "Blue") and water content is evaluated as Relative Saturation of oil by water. The detector is able to monitor oils with low light absorption (hydraulic, transformer, turbine, compressor and etc. oils) as well as oils with rather high light absorption in visible waveband (diesel and etc. oils). In a case study that the detector is applied to a diesel engine oil, it is found that the detector provides good results on oil chemical degradation as well as soot concentration.