• Title/Summary/Keyword: Contamination evaluation

Search Result 463, Processing Time 0.032 seconds

Evaluation of cellular energy allocation (CEA) in the Manila clam, Ruditapes philippinarum as a tool for assessment of contaminated sediments (오염 퇴적물 평가 기법으로서의 바지락 (Ruditapes philippinarum) 세포내 에너지 할당 (cellular energy allocation, CEA) 적용성 검토)

  • Sung, Chan-Gyoung;Kang, Sin-Kil;Chung, Jiwoong;Park, Dong-Ho;Lee, Jong-Hyeon;Lee, Chang-Hoon
    • The Korean Journal of Malacology
    • /
    • v.32 no.1
    • /
    • pp.45-54
    • /
    • 2016
  • To evaluate the applicability of cellular energy allocation (CEA) in the bivalves as a biomarker for the assessment of environmental contamination, the energy contents and energy consumption in several tissues of the Manila clam, Ruditapes philippinarum were analyzed. The contents of lipid, glucose, protein and electron transport system (ETS) activity in the foot, siphons, gills, and body of R. philippinarum exposed to crude oil-spiked sediments were measured at 1, 2, 4, 7, 10 days after exposure. The reserved energy (energy available, EA) in the lipid, glucose and protein decreased as contamination level and exposure time increased. In contrast, the ETS activity (energy consumed, EC) showed the reverse tendency. The order of available energy contents were foot > siphons > gill > body. Significant differences in both EA and EC were found only at the highest contamination level (58.3 mg TPAHs/kg DW). EA decreased significantly in the foot and gill at 1 day, in the body at 2 and 7 days after exposure. EC increased significantly in the body at 4 days after exposure. CEA showed higher sensitivity to the contamination than EA or EC. Especially, CEA in the foot and body decreased significantly at lower ranges of contamination level (as low as 6.5 mg TPAHs/kg DW) during 1 to 7 days after exposure. The CEA is more useful than EA or EC alone for the assessment of sediment contamination at lower level that acute toxicity could not be detected. CEA analyses in the body of R. philippinarum after 4 days' exposure to contaminated sediments seem to be the most sensitive and reliable.

Investigation of Microbial Contamination Levels of Leafy Greens and Its Distributing Conditions at Different Time - Focused on Perilla leaf and Lettuce - (시기별 엽채류의 미생물 오염도와 유통 조건 조사 - 들깻잎과 상추를 중심으로 -)

  • Kim, Won-Il;Jung, Hyang-Mi;Kim, Se-Ri;Park, Kyeong-Hun;Kim, Byung-Seok;Yun, Jong-Chul;Ryu, Kyoung-Yul
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.3
    • /
    • pp.277-284
    • /
    • 2012
  • The objective of this study was to investigate and evaluate microbial contamination levels of leafy greens (perilla leaf and lettuce) and its distributing conditions at different seasons (Feb, May, Aug, and Nov of the year 2011) in order to provide insight into any potential health hazards associated with consumption of these commodities. Leafy greens were collected from a farm located in Geumsan, Chungnam and wholesale markets (WM) and traditional markets (TM) located in Suwon. At the same time, temperature and relative humidity fluctuations experienced by the leafy greens during distribution from the farm to the distribution center were measured by a data logger. The contamination levels of perilla leaf and lettuce were determined by analyzing total plate count. Coliform groups, Bacillus cereus, Escherichia coli, Escherichia coli O157:H7, Salmonella spp., Listeria monocytogenes and Staphylococcus aureus were determined. The contamination levels of total aerobic bacteria, coliform groups and B. cereus in both vegetables sampled during May and August found to be higher than those sampled during February and November. E. coli O157:H7, Salmonella spp., L. monocytogenes were not detected in the vegetables analyzed in this study. There were no significant trends between samples at WM and TM in the contamination levels. Relative humidity of vegetables distributed from the farm to the distribution center showed over 90% during distribution regardless of measured seasons. In the case of background microflora on leafy greens, the density was significantly increased at 20, 30 and $37^{\circ}C$ during storage of 24h. E. coli O157:H7 and B. cereus inoculated on the leaves also showed similar increases in the storage tests. The microbial contamination levels determined in this study may be used as the fundamental data for microbial risk assessment.

Evaluation and Prediction of Cleanliness Level in the Mini-Environment System Using Local Mean Air-Age (국소평균공기연령을 이용한 국소환경시스템의 청정도 평가 및 예측)

  • Noh, Kwang-Chul;Lee, Hyeon-Cheol;Park, Jung-Il;Oh, Myung-Do
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.5
    • /
    • pp.457-466
    • /
    • 2007
  • A numerical and experimental study on the evaluation and the prediction of cleanliness level in the mini-environment system was carried out. Using the concept of local mean air-age (LMA) and effective flow rate, the new direct method for estimating the mini-environment was developed and compared with the previous performance index of airflow pattern characteristics. It was found out that the airflow pattern analysis is a restricted method to estimate the real performance of the mini-environment. The reason is that the airflow pattern cannot predict the effect of the increment of the ventilation rate on the cleanliness level in the mini-environment. While LMA is capable of showing the effects of the contaminant accumulation caused by turbulent intensity, eddy, and the increment of the effective flow rate. This result showed that LMA is more exact and effective performance index than the previous one like the airflow pattern characteristics.

The comfort evaluation and analysis of the urban rail vehicle (도시철도차량 시트의 안락성 평가 및 분석)

  • Goo, Jae-Kwang;Suh, Woo-Sung;Choi, Se-Hwa
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.222-228
    • /
    • 2007
  • In order to solve the problem of traffic holdups and environmental pollution(contamination), several metropolises are operating the subway and many local government plans hereafter the light rail vehicle operation and it is in the process of preparing. This point of time, it need to evaluate the comfortable characteristic of the seat which is closely connected with passenger and it should be reflected to the product design through the data analysis. The methods of the comfortable characteristic evaluation should be considered to various methods from physical factor to psychological factor. Among these, the most universal and possible quantitative measurement estimate through 'Body pressure measurement system'. From this paper, it was measured the body pressure of the subway seat which is in the process of operating in a domestic and it will be compared and analyzed the material & seat shape, so we evaluated the comfortable characteristic of the short-distance transportation railway vehicle. It was operated the man and woman who belongs in standard shape of Korean, we compared and analyzed the Peak position where the body pressure is visible and body pressure spread out.

  • PDF

Microbial Analysis of Processing and Evaluation of Shelf life of Fried Bean Curd (유부의 가공공정중 미생물 분석과 저장 수명 평가)

  • 노우섭
    • Journal of Food Hygiene and Safety
    • /
    • v.13 no.1
    • /
    • pp.62-67
    • /
    • 1998
  • This study was undertaken to find out distribution and contamination sources of microbes on the processing steps and to estimate quality index and shelf life of fried bean curd. It was necessary that the sanitation for water, processing environment and instruments at digestion, formation, cutting and processes after frying must be controlled and microbial growth at digestion and formation must be inhibited, to process efficiently and to improve shelf life of fried bean curd. It was evaluated that quality indexes as to sensory evaluation, especially texture, mold generation and total viable cell counts will be useful to estimate shelf life of fried bean curd and that shelf life of fried bean curd was 6 days.

  • PDF

The Evaluation on Solidification of Dredged Sediment for Recycle from Stagnant Water Area (정체성 수역 퇴적물 재활용을 위한 고형화 평가)

  • Kim, Sang Hyun;Ahn, Tae Woong;Choi, I Song;Oh, Jong Min
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.1
    • /
    • pp.63-69
    • /
    • 2012
  • Sediment has been increasingly acknowledged as a carrier in water system and an available contamination. For this reason, dredging of sediment in reservoir to remediate water quality and secure storage capacity is conducted annually. However, disposal of numerous dredged sediment is necessary as a secondary problem. Currently, in Korea, dredged sediment is classified as waste to be reclamated or recycled into sandy soil, however, they are still in trouble because of spacial and environmental problem. Therefore, rather than simple disposal or reuse into sandy soil, it is necessary to research on method to manage main cause of pollution and increase the value as a resource. In this study, we intend to develop a recycle technology for numerous dredged sediment produced by dredging in deteriorated reservoirs using solidificator (stabilizer). To achieve this, we will consider utilization of dredged sediment and evaluation of use possibility as natural recycle by analysis the characteristics of soil-solidificator mixture in terms of physicochemical properties and the mixing ratio between sediment and solidificator.

Development of low-cost, compact, real-time, and wireless radiation monitoring system in underwater environment

  • Kim, Jeong Ho;Park, Ki Hyun;Joo, Koan Sik
    • Nuclear Engineering and Technology
    • /
    • v.50 no.5
    • /
    • pp.801-805
    • /
    • 2018
  • In this study, an underwater radiation detector was built using a GAGG(Ce) scintillator and silicon photomultiplier to establish an underwater radiation exposure monitoring system. The GAGG(Ce) scintillator is suitable for small radiation detectors as it strongly absorbs gamma rays and has a high light emission rate with no deliquescent properties. Additionally, the silicon photomultiplier is a light sensor with characteristics such as small size and low applied voltage. Further, a program and mobile app were developed to monitor the radiation coefficient values generated from the detector. According to the results of the evaluation of the characteristics of the underwater radiation monitoring system, when tested for its responsiveness to radiation intensity and reactivity, the system exhibited a coefficient of determination of at least 0.99 with respect to the radiation source distance. Additionally, when tested for its underwater environmental temperature dependence, the monitoring system exhibited an increase in the count rate up to a certain temperature because of the increasing dark current and a decrease in the count rate because of decreasing overvoltage. Extended studies based on the results of this study are expected to greatly contribute to immediate and continuing evaluation of the degree of radioactive contamination in underwater environments.

Appearance/Instance of Genetically Modified Maize at Grain Receiving Harbors and Along Transportation Routes in Korea

  • Han, Sung Min;Kim, Do Young;Uddin, Md. Romij;Hwang, Ki Seon;Lee, Bumkyu;Kim, Chang-Gi;Park, Kee Woong
    • Weed & Turfgrass Science
    • /
    • v.3 no.3
    • /
    • pp.221-224
    • /
    • 2014
  • Genetically modified (GM) crops are not permitted to be cultivated in Korea, but can only be imported as food or feed purposes. The import of GM crops has sharply increased in recent years, thus raising concerns with regard to the unintentional escape of these crops during transport and manufacturing as well as the subsequent contamination of local, non-GM plants. Hence, monitoring of GM crops was studied in or outside of grain receiving ports as well as from feed-processing plants in Korea during July 2008. We observed spilled maize grains and established plants primarily in storage facilities that are exposed around the harbors and near transportation routes of the feed-processing areas. Based on the PCR analyses, a total of 17 GM maize plants and 11 seeds were found among the samples. In most cases, the established maize plants found in this study were at the vegetative stage and thus failed to reach the reproductive stage. This study concludes that, in order to prevent a genetic admixture in the local environment for GM crops or seeds, frequent monitoring work and proper action should be taken.

Development of Objective Nasometer Using a Vibratory Sensor and its Clinical Application (진동 센서를 이용한 객관적 비강공명 측정 장치의 개발 및 그 임상적 이용)

  • 최홍식;박용재;김광문
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.6 no.1
    • /
    • pp.46-55
    • /
    • 1995
  • Authors devised an objective test for nasal resonatory disorders using a vibratory sensor(Piezoelectric receiver) which is relatively cheap. The vibratory sensor was covered with duralumin to eliminate contamination of acoustic sound except a small hole which is attached on ala nasi during the test. Electrical signals front the vibratory sensor and the microphone while the subject is phonating vowel/a/ and nasal consonant /ng/ and phonating 8 syllable sentence /papa/ passage and /mama/ passage were digitized with n 12 bit A/D converter. For the evaluation of the hypernasality, the ratio of /ng/ to /a/ and /mama/ passage to /papa/ passage were used instead of individual values to reduce the observational error. For the evaluation of the hyponasality, the cul-de-sac resonation was induced by obstructing the nasal aperture of the ipsilateral side with the finger. In the normal control group, the ratio of /ng/ to /a/ and /mama/ passage to /papa/ passage was larger than 8. In the hypernasality with nasal emission group. the ratio was decreased markedly(p<0.01). When the nasal aperture was obstructed with the finger, the vibratory signals of /a/ and /ng/ were increased markedly in the control group and hypernasality group(p<0.01). However, in the hyponasality group(severe), the increment was minimal. So this system can be used to detect the nasal resonatory disorders objectively and differentiate the hypernasality front hyponasality easily.

  • PDF

Air Quality Changes in a Museum Damaged by a Tsunami - Whale and Sea Museum, Iwate, Japan -

  • MATSUI, Toshiya;KAWASAKI, Emi;Huttmann, Imme
    • Journal of Conservation Science
    • /
    • v.35 no.1
    • /
    • pp.51-60
    • /
    • 2019
  • This paper provides quantitative data that describes the evolution of the air quality in the Whale and Sea Museum, located in the Iwate prefecture, collected after the 2011 Great East Japan Earthquake and tsunami. The museum was damaged significantly by the disaster, and restoration works continued for over six years. The air quality in the temporary storage facility and museum was monitored during the rehabilitation process. Evaluation of air quality is carried out by gas chromatography- mass spectrometry, ion chromatography and high-performance liquid chromatography. The results showed that the characteristics of the chemical components differed depending on the measurement locations inside the building. The museum atmosphere tended to be alkaline as the airtightness increased because of the maintenance works at the entrance. It was also determined that it was necessary to study the intake/exhaust routes and to clean them according to the contamination degree. In Japan, there are recommended museum air quality standards for acetic acid, formic acid, alkali, and aldehydes. The results indicated that these standards should not be used as a reference for damaged museums. Furthermore, at the temporary storage facilities for to store the collections during the rehabilitation of the museum, solvents such as ethyl benzene, toluene, and xylene are initially abundant, although they can be reduced by ventilation, while other components such as 2E1H was confirmed in this case are likely to remain.