• Title/Summary/Keyword: Contactor

Search Result 225, Processing Time 0.025 seconds

Development of 7.2kV $SF_6$ Gas Electromagnetic Contactor Using Rotary Arc Method (7.2kV급 로타리아크 소호방식을 이용한 $SF_6$가스 전자접촉기 개발연구)

  • Chang, K.C.;Chong, J.K.;Shin, Y.J.;Kim, K.S.;Kim, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.330-332
    • /
    • 1997
  • In this paper, a development of the 7.2kV class $SF_6$ gas electromagnetic contactor which is used a rotary-arc principle in interrupting method is presented. A prototype contactor is made. In the interrupting small current permanent-magnet is used and in the interrupting high current the coil through which arc current itself flows is used. Successfully the prototype contactor carrys out the making, the braking and short time test.

  • PDF

Continuous Degradation of Formaldehyde by Peudomonas putida H-5 Using Rotation Disc Contactor (회전원판반응조에 의한 Peudomonas putida H-5의 포름알데히드의 연속적 분해)

  • 류병호;임복규
    • KSBB Journal
    • /
    • v.8 no.1
    • /
    • pp.42-48
    • /
    • 1993
  • Continuous degradation of formaldehyde by using a rotating disc contactor was investigated in this study. Peudomonas putida H-5K was selected as a mutant using N-methyl N'-nitro N-nitrosoguandine (250$\mu\textrm{g}$/$m\ell$), which showed 1.5 times higher ability of formaldehyde degradation than that of the parent strain. Enzyme activity for formaldehyde degradation released form Peudomonas putida H-5K showed the highest level of 6.2mo1/min/mg protein in the 2% glucose mineral medium containing 0.02% formaldehyde. Degradation of formaldehyde from the first stage in rotating disc contactor was 95% and 5% from the 4th stage when the reactor was fed with 0.02% or 0.04% formaldehyde solution at a rate of 20$m\ell$ per hour. Continuous degradation of formaldehyde using rotating disc contactor was above 95%o in the medium containing 0.04% formalchyde, at the medium feed ratc of 20$m\ell$ per hour.

  • PDF

Removal Phosphorus Using Iron Contactor by Intermittent Aeration Activated Sludge Process (철 접촉재를 이용한 간헐폭기식 활성슬러지 공법에 의한 인의 제거)

  • 이영신;김동민
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.4
    • /
    • pp.33-37
    • /
    • 1993
  • The problem for the removal of phosphorus increased due to reasons like eutrophication control. However its removal and operating criteria were not well developed. This study was made for enhanced removal of P by iron contactor by intermittent aeration activated sludge process. Experiment was conducted to find the effects of organic substance load and HRT, nutrient removal efficiency. When applied organic substance load and HRT, II &III reactor were good treatment efficient while come from Fe of iron contactor. Release of phophorus from II &III reactor sludge under anaerobic condition was low. As the process developed, the content of released ionized Fe from iron contactor increased. In addition, the rate of phosphorus removal became accelerating, and the removed sludge was stabilized in the existence of insoluble status.

  • PDF

Effects of Mm(misch metal) Addition on The Property of Ag-CdO alloys for Electrical Contactor (전기접점용 Ag-CdO합금의 물성에 미치는 Mm(misch metal) 첨가의 영향)

  • Park, Su-Dong;Lee, Hee-Woong;Kim, Bong-Seo;Kim, Byung-Geol;Song, Jae-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.34-37
    • /
    • 2004
  • It is well known that Ag-CdO alloy for electrical contactor has been widely used in weak or middle electric current field. But it is necessary to decrease Cd contents without decrease of contactor property because Cd is harmful to human body. The present work has been carried out to investigate effects of Mm (misch metal) addition on the property of Ag-CdO alloy for electrical contactor. As the results of present works, hardness and strength was improved and arc resistance was improved, also, in spite of decrease Cd contents by the Mm addition. It was estimated that Ag-oxide particle was refined by Mm addition.

  • PDF

A study on the suppress method of arc on a electromagnetic contactor (전자개폐기의 arc 억제방안에 관한 연구)

  • 노창주;홍순일;정승환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.40-48
    • /
    • 1983
  • Nowadays electromagnetic contactors are used for power on-off in various electrical loads. If the severe arc are occurred when power off, the magnetic contactor can not long run because of damage of contactor. In this paper, Authors indicate a method of how to minimize the arc when power off, Authors contrived a electronic circuit which can adjust the demagnetizing point of electro magnetic contactor, and control the demagnetizing point, utilizing our circuit, so as to occur the extinguish of arc at near the AC current zero point which is indispensibly exists. From the results of study, Authors could get confirmations the AC circuit could cut off with occurrence of mininum arc, and that possibility of extensive utilization of our method to hightension circuit.

  • PDF

Ammonia Removal Characteristics in Membrane Contactor System Using Tubular PTFE Membrane (관형 PTFE 분리막을 이용한 막 접촉기(Membrane Contactor) 시스템에서 암모니아의 제거 특성)

  • Ahn, Yong-Tae;Hwang, Yu-Hoon;Shin, Hang-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.5
    • /
    • pp.353-358
    • /
    • 2011
  • In this study, ammonia removal characteristics in membrane contactor system under various operating conditions were evaluated. The mass transfer coefficient was used to quantitatively compare the effect of various operation conditions on ammonia removal efficiency. Effective removal of ammonia was possible with the tubular PTFE membrane contactor system at all tested conditions. Among the various operation parameters, contact time and solution pH showed significant effect on ammonia removal mechanism. Overall ammonia removal rate was not significantly affected by influent suspended solution concentration unlike other pressure driven membrane filtration processes. Also the osmotic distillation phenomena which deteriorate the mass transfer efficiency can be minimized by preheating of strip solution. Membrane contactor system can be a possible alternative to treat high strength nitrogen wastewater by optimizing operation conditions such as stripping solution flow rate, influent wastewater temperature, and influent pH.

A Study on the Determination of Optimal Circuit Constants of Shading Coil (Shading Coil의 최적 회로정수 결정에 관한 연구)

  • 김시화
    • Journal of the Korean Institute of Navigation
    • /
    • v.9 no.1
    • /
    • pp.95-109
    • /
    • 1985
  • It has been generally known that the chattering of an AC electromagnetic contactor due to the fluctuation of attracting force is the primary cause of its abrasion and noise. To reduce this chattering effect, an AC electromagnetic contactor is mostly fitted with a shading coil which works the role to make difference in phases of two distinct components of attracting force. The theoretical interpretation of an AC electromagnetic contactor with shading coil and the equation of its attracting force per unit wattage consumed have already been proposed, however, few explications so far have been made on the determination of optimal circuit constants of shading coil. In this paper, the auther constructs a circuit model of an AC electromagnetic contactor with shading coil which is based on the theoretical interpretation of shading coil examined to be valid by experiments under some assumptions, and defines the equation of attracting force without chattering per unit wattage consumed as a performance function for determining the optimal circuit constants of shading coil. And then, the optimal circuit constants maximizing the performance function are determined by means of computer simulation founded on the above circuit model and the characteristics of those circuit constants are examined with special attention to the coupling coefficient.

  • PDF

To Ensure A Product Reliability The Study on Accelerated Stress Tests for Magnetic Switch Used in Power Distribution System (제품 신뢰성 확보을 위한 배전 계통에 사용되는 전자개폐기 가속스트레스시험에 관한 연구)

  • Ryu, Haeng-Soo;Park, Sang-Yong;Han, Gyu-Hwan;Kwon, Young-Il;Yoon, Nam-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.377-380
    • /
    • 2005
  • In this paper, accelerated stress test(AST) for Magnetic Switch (MS) are applied to assure specified reliability of the products. Magnetic contactor that functions with over-current relay is called MS. Magnetic contactor closes and opens the motor load with ON/OFF switch of electronic contactor. It is also used for protecting and controlling the load. Magnetic contactor detects the over-current flow in the load with a over-current relay and disconnects the load by opening its control power. In this study, AST for product assembly are developed in order to improve the weak point so that increase the product reliability. Also we will show the basic information for the accelerated life test(ALT). The proposed AST results and procedures may be extended and applied to testing similar kinds of products to reduce test times and costs of the tests remarkably. Finally the results of this study will contribute to improving reliability of products and strengthening competitiveness of our products in the world markets.

  • PDF

A Study on Accelerated Life Tests for Magnetic Switch Used in Distribution System (배전선로에 사용되는 전자개폐기(Magnetic Switch)의 가속수명시험에 관한 연구)

  • Ryu, Haeng-Soo;Han, Gyu-Hwan;Kwon, Young-Il
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.536-540
    • /
    • 2002
  • In this paper, accelerated life test (ALT) models and procedures for Magnetic Switch (MS) are developed and applied to assure specified reliability of the products at development phase and guarantee the life of the products. Magnetic contactor that functions with over-current relay is called MS. Magnetic contactor closes and opens the motor load with ON/OFF switch of electronic contactor. It is also used for protecting and controlling the load. Magnetic contactor detects the over-current flow in the load with a over-current relay and disconnects the load by opening its control power. In this study, ALT models for MS are developed using the relationship between stresses and life characteristics of products. Using the ALT models, we performed life tests and analyzed the tests results. The proposed ALT models and procedures may be extended and applied to testing similar kinds of products to reduce test times and costs of the tests remarkably. Finally the results of this study will contribute to improving reliability of products and strengthening competitiveness of our products in world markets.

  • PDF

Biodergradation of Reactive Dyes Using Multistage Rotating Disc Contactor Immobilized by Aspergillus sojae B-10 (회전원판 반응조에 고정화시킨 Aspergillus sojae B-10에 의한 반응성 염료의 탈색)

  • 류병호;김동석;진승록;정종순;원용돈
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.4
    • /
    • pp.49-55
    • /
    • 1995
  • Dyes are released into the environment as industrial wasterwater. Dyes are considered to be a pollution problem because of the wide spread into environment with a variety of colors. Continuous biodegradation of reactive dyes such as Rifacion Red H-3EB, Rifazol Blue BT, Rifacion Yellow P4G and Rifacion Brown RT were demonstrated using multistage rotating disc contactor immobilized by Aspergillus sojae B-10. Aspergillus sojae B-10 was cultivated the optimal medium containing 2.0% glucose, 0.08% $NaNO_3$, 0.1% $KH_2PO_4$ and 0.5% $MgSO_4\cdot 7H_2O$, pH 5 at 32$\circ$C. Mycelium of Aspergillus sojae B-10 were guck to the rotating disc for 10 days until steady state. For continuous biodegradation of reactive dyes by using rotating disc contactor, it was most effective biodegradation in the medium containing 1,000 ppm each dyes at the medium feeding rate of 20 ml per hour. Under the conditions biodegradation of each dyes on 2, 4 and 6 days were 20~50%, 75% and 96%, respectively. Therefore, practical application of reactive dyes were carried out at the feeding rate of 20 ml/h as synthetic wasterwater containing 500 ppm of mixture reactive dyes. It was found the highest levels of 94% biodegradation during 20 days.

  • PDF