• Title/Summary/Keyword: Contact state

Search Result 825, Processing Time 0.027 seconds

Electrical Impedance Change due to Contamination at the Contact Interface of Connectors for Automobile Crank Shaft Position Sensor

  • Kim, Young-Tae;Sung, In-Ha;Kim, Dae-Eun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.5 no.2
    • /
    • pp.46-52
    • /
    • 2004
  • Numerous connectors are used in automobiles for transmission of electrical signals across various electro-mechanical components. The connectors must operate with high reliability in order to minimize failures due to signal degradation. In this work, the effects of contamination at the contact interface of connectors used fur automobile crankshaft position sensor on the impedance change were investigated. An experimental set-up was built to simulate the electrical signal transmitted from the sensor to the engine control unit through a connector. Output from the connector was investigated using connectors contaminated with engine block residues and water droplets. It was found that slight contamination of the connectors could lead to significant signal degradation which can lead to engine failure. Also, the effect of water in the connector altered the signal severely. However, the signal gradually regained the original state as the water evaporated from the interface.

A Study of Soft Contact Lens Wearer on Women College Students (여대생의 소프트 콘택트렌즈 착용자에 대한 연구)

  • Kim, Douk-Hoon;Yoo, Jae-Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.187-192
    • /
    • 2000
  • The objective of this study was to investigate the problems of soft contact lens wear on the women college students. The results were as follows 1. Almost the purchase of soft contact lens was the optical shop. 2. Almost the motive of soft contact lens use was the discomfort of glasses wear. 3. Almost the good feeling of glasses wear was moderate degree. 4. On the main reason of exchange of contact lens, teens was contact lens damage and tweenths was lifespan of contact lens. 5. On the contact lens wearing time at one day, teens was over 10 hours and tweenths was from 7 hours to 10 hours. 6. On the contact care and treatment, teens was a lens washing and storage and tweenths was a lens washing and disinfectant. 7. On the main difficult of contact lens handling, teens was a lens separation in eye and disinfection of lens case and tweenths was a solution treatment and insertion of contact lens in the eye. 8. On the contact lens insertion in the eye, the most difficult item was hanging of the eyelid and fear thinking in teens and fear thinking in tweenths. 9. On the difficult in separate of contact lens wear, a most subjects were eye opening. 10. On the most inconvenient state in contact lens wearing, the subjects were eye redness, foreign body and eye pain. 11. On the advantage of contact lens wearing, teens was decrease in glasses side effects and twenties was a beauty.

  • PDF

The Actual Management State of Trial Contact Lenses and Lens Care Products in Local Optical Shops (안경원의 시험착용 콘택트렌즈 및 관리용품 관리 실태)

  • Park, Mijung;Lee, Unjung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.391-401
    • /
    • 2011
  • Purpose: In the present study, the actual management state of trial contact lenses and lens care products in local optical shops was surveyed and analyzed to reduce the risk of lens complication possibly induced by neglecting lens care. Methods: The feeling of contact lens wearers during the wear of trial contact lenses was surveyed. Futhermore, the actual management state of trial contact lenses such as cosmetic lens and RGP lens and lens care products was also investigated by surveying opticians who trade contact lenses in local optical shops. Results: It was found that consumers trusted the sanitary conditions of the lens since trial cosmetic contact lens and RGP lens were cleaned before and after trails by over 98% of opticians in local optical shops. For trial cosmetic lens, cleaning with normal saline, multipurpose solution for soft lens and combination of saline and multipurpose solution were 38.5%, 40.5% and 21%, respectively, before trials. After trials, cosmetic lenses were cleaned with normal saline, multipurpose solution for soft lens and a combination of saline and multipurpose solution were 13%, 75%, and 12%, respectively. On the other hand, cleaning with normal saline, multipurpose solution for RGP lens and combination of saline and multipurpose solution were 28.5%, 38.5% and 33%, respectively, before trying trial RGP lens. After trials, RGP lenses were cleaned with normal saline, multipurpose solution for RGP lens and a combination of saline and multipurpose solution were 2.5%, 70%, and 27.5%, respectively, indicating that relatively many opticians followed the lens cleaning regimen. In local optical shops, the cleaning trial cosmetic lens was mainly conducted at every 10 days or a month and the washing cycle of cosmetic lens case was in a month or 2~3 months. The cleaning interval of trial RGP lens was primarily in a month or 2~3 months. For those lens cases, more than 75% of opticians washed them with a surfactant and then rinsed with cold water. The storing periods of lens care products were primarily in a week for saline and in a month and 2~3 months indicating that storing period of lens care products was relatively well-kept in local optical shops. Conclusions: It is thought that the concern about any microbial infection is not that high since trial contact lenses and lens care products were generally well-managed by opticians in local optical shops from the results above. However, better public eye health and better public confidence in opticians may be possible if further strengthen in avoidance of lens cleaning with saline, keep of cleaning cycles within 2 weeks and rinsing of lens cases with hot water happens.

Electric field distribution on the surface of polymer post insulator according to state of water drops (오손물질에 따른 고분자 장간애자의 표면 전계분포)

  • Jang, Dong-Uk;Han, Moon-Seob;Kim, Hyun-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1418-1419
    • /
    • 2007
  • In order to check the electric field distribution of polymer line post insulator, we performed electric field simulation according to state of water drops. Sea water is used to the contaminant. Electric field analysis is performed with change of contact angle, number and distance of water drops.

  • PDF

Dialogue State Tracking using Circumstance Information to Improve the Accuracy of Task-Oriented Dialogue System in Metaverse (메타버스에서 목적 지향 대화 시스템의 정확도 향상을 위한 상황 정보 활용 대화 상태 추적 기술)

  • Kim, Seungyeon;Bang, Junseong
    • Journal of Broadcast Engineering
    • /
    • v.27 no.5
    • /
    • pp.685-693
    • /
    • 2022
  • The Metaverse is getting popular due to the demands for digital transformation and non-contact communication platforms. A conversation system which facilitates communication is not widely applied yet in Metaverse. In this work, we present a method that revises primitive dialogue state using circumstance information from Metaverse. The presented model that leverages both dialogue and circumstance information consists of a dialogue state tracking module and a circumstance state tracking module. In the model, a dialogue state is updated with an algorithm which compares a dialogue state and a circumstance state. As a conversation that reaffirms user intent is added, a wrong dialogue state can be revised and the accuracy of a conversation system can be improved.

Effect of Experimental Muscle Fatigue on Muscle Pain and Occlusal Pattern (실험적으로 유발되는 근피로가 근통증 및 교합양상에 미치는 영향)

  • Kim, Jae-Chang;Lim, Hyun-Dae;Kang, Jin-Kyu;Lee, You-Mee
    • Journal of Oral Medicine and Pain
    • /
    • v.33 no.3
    • /
    • pp.279-294
    • /
    • 2008
  • This study aimed to make an analysis of the occlusion in the state of muscle fatigue produced by excessive mouth opening and clenching during the dental treatment to control the dental pain and to evaluate the sensory nerve in the muscle pain state. Most of the reasons why patients visit the dental office result in pain-either conceivably the dental origin pain or the non-dental origin pain. The dental offices have many therapeutic actions to produce the masticatory muscle fatigue for the treatment. Dental treatment with long minutes of mouth opening can cause some headaches, masticatory muscle pain and mouth opening difficulties. Patients with mastication problems who visits a dental office to alleviate pain run against another unexpected pain with other aspects. This study uses T-scan II system(Tekscan Co., USA) for the evaluation on the occlusal pattern in the experimental muscle fatigue after clenching, opening the mouth excessively and chewing gum. The occlusal contact pattern is analyzed by the contact timing, namely first, intercuspal, maximum and end point of contact. This inspection was performed at frequencies of 2000Hz, 250 Hz and 5 Hz before and after each experimental muscle pain was produced to 24 subjects who had normal occlusion without the orthodontic treatment or a wide range of the prosthesis by using $neurometer^{\circledR}$ CPT/C(Neurotron, Inc. Baltimore, Maryland, USA). The measuring sites were mandibular nerve experimental muscle fatigue respectively. This study could obtain the following results after the assessment of occlusion and sensory nerve of the experimental muscle fatigue. 1. There were the fastest expression after the excessive mouth opening in muscle fatigue and after tooth clenching in muscle pain. In the visual analog scale that records the subjective level, there was the highest scale after the clenching in the muscle fatigue in jumping off the point of pain. 2. Tooth contact time, contact force, relative contact force on the point of the first contact had no difference, and there were decreases in the contact force after the excessive mouth opening on intercuspal position point, after the excessive mouth opening and the gum chewing on the point of the maximum, and in the contact time after all the experimental muscle fatigue state on the point of the end contact. 3. There was no statistic significance in the current perception threshold before and after the experimental muscle fatigue. 4. There was no significant difference in the contact number, the maximal contact number on the point of the first contact, and the contact number after the mouth opening and gum chewing on the point of the intercuspal position and the contact number after the experimental muscle fatigue on the maximum point, and showed significant decreases. In conclusion, it was found that the occlusal pattern can cause the changes on the case of the clinical muscle weakness by intra-external oral events. It was important that the sedulous attention to details is required during dental treatment in case of excessive mouth opening, mastication and clenching.

Elution Properties of Naringin from Soft Contact Lens Containing Naringin (나린진(naringin)이 함유된 소프트 콘택트렌즈에서 나린진의 용출 특성)

  • Ryu, Geun-Chang;Jun, Jin;Jin, Moon-Seok;Chae, Soo-Chul;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.45-50
    • /
    • 2008
  • Purpose: A soft contact lens was manufactured by adding naringin known as natural anti-bacterial material to resin solution. With solution eluted from manufactured contact lens, we examined its optical properties, physical and chemical states of naringin in the polymer, and elution properties. Methods: The soft contact lens with naringin was synthesized by bulk polymerization method. IR spectrum and HPLC were used to define the bonding type of naringin itself in the soft contact lens contained naringin, elution process of naringin to the saline solution, and the amount of naringin solution eluted from the lens with elapsed time. Results: Naringin was continuously eluted with constant concentration from the soft contact lens for about a month and the structure ofnaringin which is eluted was as same as before it was added to resin solution. Any change in optical properties such as transmittance couldn't be found. Bonding state and the structure of naringin in contact lens were explained with IR spectrum and HPLC results. Conclusions: In the contact lens with naringin, naringin remained in the contact lens bonding with weak hydrogen bonding and/or van der Waals force between naringin and polymer. Naringin was continuously eluted from the contact lens contained naringin during about 1 month. Even after 1 month, it showed that the concentration of the naringin eluted was approximately 10 ppm in a day. From the results, adding naringin to the soft contact lens resin is very effective method for manufacturing the soft contact lens which has anti-bacterial function for a period of time.

  • PDF

A Bonding Surface Behavior of Bi-metal Bar through Hydrostatic Extrusion (이중복합봉 정수압 압출시 접합면 거동에 관한 연구)

  • Park, Hun-Jae;Na, Gyeong-Hwan;Jo, Nam-Seon;Lee, Yong-Sin
    • Transactions of Materials Processing
    • /
    • v.7 no.1
    • /
    • pp.66-71
    • /
    • 1998
  • The present study is concerned with the hydrostatic extrusion process of copper-clad aluminium bar to investigate the bonding conditions as well as the basic flow characteristics. Considering the bonding mechanism of bi-metal contact surface as cold pressure welding the normal pressure and the contact surface expansion are selected as process parameters governing the bonding conditions, in this study the critical normal pressure required for the local extrusion-the protrusion of virgin surfaces by the surface expansion at the interface-is obtained using a slip line method and is then used as a criteron for the bonding. A rigid plastic finite element method is used to analyze the steady state extrusion process. The interface profile of bi-metal rod is predicted by tracking the paths of two particles adja-process. The interface profile of bi-metal rod is predicted by tracking the paths of two particles adja-cent to interface surface. The contact surface area ration and the normal pressure along the interface are calculated and compared to the critical normal pressure to check bonding. It is found that the model predictions are generally in good agreement with the experimental observations. The compar-isons of the extrusion pressure and interface profile by the finite element with those by experi-ments are also given.

  • PDF

The Electrical Properties of GaN Individual Nanorod Devices by Wet-etching of the Nanorod Surface and Annealing Treatment (표면 습식 식각 및 열처리에 따른 GaN 단일 나노로드 소자의 전기적 특성변화)

  • Ji, Hyun-Jin;Choi, Jae-Wan;Kim, Gyu-Tae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.2
    • /
    • pp.152-155
    • /
    • 2011
  • Even though nano-scale materials were very advantageous for various applications, there are still problems to be solved such as the stabilization of surface state and realization of low contact resistances between a semiconducting nanowire and electrodes in nano-electronics. It is well known that the effects of contacts barrier between nano-channel and metal electrodes were dominant in carrier transportation in individual nano-electronics. In this report, it was investigated the electrical properties of GaN nanorod devices after chemical etching and rapid thermal annealing for making good contacts. After KOH wet-etching of the contact area the devices showed better electrical performance compared with non-treated GaN individual devices but still didn't have linear voltage-current characteristics. The shape of voltage-current properties of GaN devices were improved remarkably after rapid thermal annealing as showing Ohmic behaviors with further bigger conductivities. Even though chemical etching of the nanorod surfaces could cause scattering of carriers, in here it was shown that the most important and dominant factor in carrier transport of nano-electronics was realization of low contact barrier between nano-channel and metal electrodes surely.

Optimal Dimple Point of SFF HDD Suspension for Improving the Unloading Performance (언로드 성능 향상을 위한 딤플 포인트의 최적설계)

  • Kim, Ki-Hoon;Lee, Young-Hyun;Lee, Hyung-Jun;Park, No-Cheol;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.609-612
    • /
    • 2007
  • The HDD (hard disk drive) using Load/Unload (L/UL) technology includes the benefits which are increased areal density, reduced power consumption and improved shock resistance than those of contact-start-stop (CSS). Dynamic L/UL has been widely used in portable hard disk drive and will become the key technology for developing the small form factor hard disk drive. The main design objectives of the L/UL mechanisms are no slider-disk contact or no media damage even with contact during L/UL, and a smooth and short unloading process. In this paper, we focus on lift-off force, pitch static attitude (PSA), roll static attitude (RSA) and dimple point. The "lift-off" force, defined as the minimum air bearing force, is another very important indicator of unloading performance. A large amplitude of lift-off force increases the ramp force, the unloading time, the slider oscillation and contact-possibility. PSA and RSA are also very important parameters in L/UL system and stability of slider is mainly determined by PSA and RSA. Dimple point by PSA and RSA is also important indicator. Therefore we find the optimal dimple point of SFF HDD suspension for improving the unloading performance.

  • PDF