• Title/Summary/Keyword: Contact center

Search Result 1,818, Processing Time 0.029 seconds

Dynamic Motion Analysis of a Moving Contact by Electromagnetic Repulsion Force in MCCB (3D FEM해석을 통한 배선용 차단기의 가동자 거동해석)

  • Song, Jung-Chun;Kim, Yong-Gi;Ryu, Man-Jong;Seo, Jung-Min
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.786-789
    • /
    • 2002
  • The behaviour of contactors protected by arcs under short-circuit currents is analysed using a simple model to represent the electric circuit and the contactor. In most cases, the protection of contactors against short-circuit currents is entrusted to fuses. Fuses are suitable for preventing excessive damage to the contactor, or parts of the contactor, under short-circuit conditions. In particular, they are capable of limiting the thermal and electrodynamic stresses which can lead to arcing or welding together of the contacts of a contactor. This paper is the Dynamic Motion Analysis of a Moving Contact by Electromagnetic Repulsion Force in Molded Case Circuit Breaker(MCCB)

  • PDF

High Performance Bottom Contact Organic TFTs on Plastic for Flexible AMLCD

  • Kim, Sung-Hwan;Choi, Hye-Young;Han, Seung-Hoon;Jang, Jin;Cho, Sang-Mi;Oh, Myung-Hwan
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.889-892
    • /
    • 2004
  • We developed a high performance bottom contact, organic thin-film transistor (OTFT) array on plastic using a self-organized process. The effect of OTS treatment on the PVP gate insulator for the performance of OTFT on plastic has been studied The OTFT without OTS exhibited a field-effect mobility of 0.1 $cm^2$/Vs on/off current ratio of > $10^7$. On the other hand, OTFT with OTS, exhibited a field-effect mobility of 1.3 $cm^2$/Vs and on/off current ratio of>$10^8$.

  • PDF

The Formation and Characteristics of Titanium Germanide with Cr capping layer on n-Ge(100) Substrate (Cr capping layer를 이용한 n-Ge(100) 기판에서의 Ti germanide 형성과 특성에 관한 연구)

  • Mun, N.J.;Choi, C.J.;Shim, K.H.;Park, D.S.;Yang, H.Y.;Jeong, M.R.;Yoon, C.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.154-154
    • /
    • 2009
  • Cr capping layer를 이용하여 Titanium germanide의 열적 안정성을 향상시키는 연구를 수행하였다. n-type Ge(100) 기판 위에 전자빔 증착기를 이용하여 30nm 두께의 Ti와 Cr capping layer를 증착하고 $400\;^{\circ}C$에서 $800\;^{\circ}C$까지 30초간 N2 분위기로 급속 열처리하여 Ti germanide를 형성하였다. XRD결과로부터 Cr capping layer의 유무에 관계 없이 Ti germanide가 형성된 것을 관찰할 수 있었다. Ge 기판 위에 CTLM 패턴을 형성하고 실험을 진행하여 Ti germanide의 I-V 측정 데이터를 통해 Ohmic 특성을 알아보았고, contact resistance, sheet resistance, specific contact resistance를 구하였다.

  • PDF

Experimental study on the Sealing Force of NBR O-Ring with high Temperature (고온조건에서 NBR O-링 밀봉력에 관한 실험적 연구)

  • Kim Dohyun;Kang Hyunjoon;Kim Chungkyun;Ko Youngbae
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.209-212
    • /
    • 2004
  • The O-ring seal is a usual component part in various mechanical apparatuses for sealing that makes efficient performance of the equipments. The sealing performance of 0-ring is effected in environments of the O-ring seal, like that applied pressures, working temperatures, interferences and materials. In this paper, an pressurized, NBR O-ring is calculated by experimental methods and analysed numerically using the MARC finite element program. The calculated experimental and FEM results showed that the Contact force O-ring decreases as a function of temperature.

  • PDF

Surface-Properties of Poly(Ethylene Terephthalate) Fabric by In-line Atmospheric Plasma Treatments (연속 대기압 플라즈마를 처리한 폴리에스테르 섬유의 표면 특성)

  • Kwon, Il-Jun;Park, Sung-Min;Koo, Kang;Song, Byung-Kab;Kim, Jong-Won
    • Textile Coloration and Finishing
    • /
    • v.19 no.4
    • /
    • pp.38-46
    • /
    • 2007
  • Surface properties of the plasma treated fabric were changed while maintaining its bulk properties. Surface of plasma treated fabric take charge of enhanced adhesion by surface etching, surface activity. The water repellency coating Poly(Ethylene Terephthalate) fabric was treated with atmospheric pressure plasma using various parameters such as Argon gas, treatment time, processing power. Morphological changes by atmospheric pressure plasma treatment were observed using field emmission scanning electron microscopy(FE-SEM) and the zeta-potential measurement, contact angle measurement equipment. At the atmospheric pressure plasma treatment time of 150 sec, the power of 800W, the best wettability and peel strength were obtained. And we confirmed the possibility of industrial application by using atmospheric plasma system.

Surface Modification of Thin Film using Trimethylchlorosilane Vaporization Treatment

  • Choo, Byoung-Kwon;Kim, Ki-Hwan;Song, Na-Young;Choi, Jung-Su;Park, Kyu-Chang;Ang, Jin;Kim, Jin-Ook;Nam, Yeon-Heui;Chae, Gi-Sung;Chung, In-Jae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.900-903
    • /
    • 2007
  • We introduce non-contact surface modification using trimethylchlorosilane (TMCS) for thin film transistor application. The surface is not contacted to the TMCS solution because it is vaporized at room temperature. The hydrophobic surface with contact angle $of\;{\sim}\;70^{\circ}$ can be achieved by the transfer of TMCS using a PDMS mold.

  • PDF

Electrical Characteristics of Bottom-Contact Organic Thin-Film-Transistors Inserting Adhesion Layer Fabricated by Vapor Deposition Polymerization and Ti Adhesion Metal Layer

  • Park, Il-Houng;Hyung, Gun-Woo;Choi, Hak-Bum;Kim, Young-Kwan
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.958-961
    • /
    • 2007
  • The electrical characteristics of organic thin-filmtransistor (OTFTs) can be improved by inserting adhesion layer on gate dielectrics. Adhesion layer was used as polymeric adhesion layer deposited on inorganic gate insulators such as silicon dioxide $(SiO_2)$ and it was formed by vapor deposition polymerization (VDP) instead of spin-coating process. The OTFTs obtained the on/off ratio $of{\sim}10^4$, threshold voltage of 1.8V, subthreshold slop of 2.9 V/decade and field effect mobility about $0.01\;cm^2/Vs$.

  • PDF

Design of Shaking Beam for Piezoelectric Linear Ultrasonic Motor

  • Yoon, Seok-Jin;Park, Ji-Won;Kim, Sang-Jong;Yu, Yeon-Tae;Kim, Hyun-Jai
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.11
    • /
    • pp.1062-1066
    • /
    • 2003
  • Design of a piezoelectric actuator for the ultrasonic motor must ensure that contact point has elliptic trajectory of movement. The new idea of an elliptic trajectory formation of the piezoelectric actuator is investigated in the paper. Shaking beam for the piezoelectric linear ultrasonic motor was introduced to realize this new idea. The principle is based on the excitation of longitudinal and flexural vibrations of the actuator by using two sources of longitudinal mechanical vibrations shifted by $\pi$/2. Mode-frequency and harmonic response analyses of the actuator based on FEM have been carried out. The moving trajectory of the contact point has been defined. Finally, The experimental research of shaking beam has been confirmed an opportunity of the elliptic trajectory reception with the help of one stable mode of the vibrations.

A Study on Contact Force Analysis of Plate Gears for Cycloidal Speed Reducer with Friction Effect (마찰효과를 고려한 사이클로이드 감속기의 작용력 해석에 관한 연구)

  • 홍진표;신중호;권순만;장세원
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1262-1265
    • /
    • 2004
  • A cycloidal speed reducer is a type of the speed reducers of machinery. The cycloidal speed reducer consists of two cycloidal plate gears, housing roller gear, input shaft, output pin and shaft, and eccentric bearings. Especially the cycloidal plate gear has the peculiar parts of the teeth, because of gearing with the housing roller gear that has the several rollers on the circular line. And then all teeth on the cycloidal plate gear can be designed to contact with the rollers on the housing roller gear at the same time. Therefore the cycloidal plate gear has always contact motion with rollers and the force is interacted between roller gear with cycloidal plate gear. Because the contact force and friction force must be required to improve the accuracy in design procedures of cycloidal speed reducers, this paper presents a force analysis considered friction effect approach derived by static force equilibrium condition, geometrical adaptation, instant velocity center method and relative velocity method.

  • PDF

The Subsurface Stress Field Caused by Both Normal Loading and Tangential Loading

  • Koo Young- Phi;Kim Tae-Wan;Cho Yong-Joo
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.11
    • /
    • pp.1967-1974
    • /
    • 2005
  • The subsurface stress field caused by both normal loads and tangential loads has been evaluated using the rectangular patch solution. The effect of tangential loading on the subsurface stress field has been investigated in detail for both the cylinder-on-cylinder contact and a spur gear teeth contact. For the cylinder-on-cylinder contact, the subsurface stress fields are moved more to the direction of tangential loads and the positions where the maximum stress occur are getting closer to the surface with the increasing tangential loads. The subsurface stress fields of the gear teeth contact are expanded more widely to the direction of tangential loads with the increasing tangential loads. The friction coefficient of a gear teeth contact is low because they are operated in a lubricated condition, and therefore surface tractions in the EHL condition hardly affect on the subsurface stress field.