• Title/Summary/Keyword: Contact Sensitivity

Search Result 252, Processing Time 0.027 seconds

Development of $^{192}Ir$ Small-Focal Source for Non-Destructive Testing Application by Using Enriched Target Material (고농축 표적을 이용한 비파괴검사용 $^{192}Ir$ 미세초점선원 개발)

  • Son, K.J;Hong, S.B.;Jang, K.D.;Han, H.S.;Park, U.J.;Lee, J.S.;Kim, D.H.;Han, K.D.;Park, C.D.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.1
    • /
    • pp.31-37
    • /
    • 2007
  • A $^{192}Ir$ small-focal source has been developed by using the HANARO reactor and the radioisotope production facility at the Korea Atomic Energy Research Institute (KAERI). The small-focal source with the dimension of 0.5 mm in diameter and 0.5 mm in length was fabricated as an aluminum-encapsulated form by a specially designed pressing equipment. For the estimation of the radioactivity, neutron self-shielding and ${\gamma}-ray$ self-absorption effects on the measured activity was considered. From this estimation, it is realized that $^{192}Ir$ small-focal sources over 3 Ci activities can be produced from the HANARO. Field performance tests were performed by using a conventional source and the developed source to take images of a computer CPU and a piece of a carbon steel. The small-focal source showed better penetration sensitivity and geometrical sharpness than the conventional source does. It is concluded from the tests that the focal dimension of this source is small enough to maximize geometrical sharpness in the image taking for the close proximity shots, pipeline crawler applications and contact radiography.

The Effect of Natural Exploration Activity on Environmental Perception of the Science High School Students (자연탐사활동이 과학고 학생들의 환경인식에 미치는 효과)

  • Kim, Soon-Shik;Choi, Sung-Bong
    • Journal of Environmental Science International
    • /
    • v.19 no.3
    • /
    • pp.343-351
    • /
    • 2010
  • Since the effect of environmental education at class using textbooks or materials related to environment is limited, the importance of activities for field experience is getting increased day by day. Thereby, the education tends to change into the type of education providing students with direct environmental experience. Students attending the science high school have excellent aptitude and ability for science and will lead the development of science in the future. Now it is urgent to develop various experiential programs which are helpful for them to establish desirable values on environment. However, the field of environmental education that allows science high school students equipped with ample environmental knowledge to improve environment sensitivity and have proper environment awareness is quite restricted as of now. Natural exploration activities are the programs which provide science high school students having lack of chance for environmental education with good opportunities to contact nature and also play significant roles in arousing their interest in issues related with environment. Therefore, it is thought that they will let science high school students explore the natural features of Korea, understand the importance of preserving environment and ecosystem profoundly, and encourage environmental awareness and will of environmental practice. Thereupon, with the study subjects of 121 first and second graders at U Science High School, this article analyzed their recognition of the necessity for environmental education and environmental pollution problems before and after the natural exploration activities, and conducted a survey on their satisfaction after the natural exploration activities and analyzed it. The result of this research is as follows. First, it was shown that the natural exploration activities were effective to raise the science high school students' awareness of issues related with environmental pollution. Second, the natural exploration activities had effect upon enhancing the students' willingness of environmental practice. Third, there was statistically significant correlation between the science high school students' satisfaction with the natural exploration activities and their achievement in the science subject. Fourth, there also was a statistically non or weakness significant correlation between their satisfaction with the natural exploration activities and preference for the science subject. In particular, it was found that students preferring biology indicated higher satisfaction.

A NEW METHOD TO MEASURE THE LINEAR POLYMERIZATION SHRINKAGE OF COMPOSITES USING A PARTICLE TRACKING METHOD WITH COMPUTER VISION (컴퓨터 시각과 입자 추적 방법을 이용한 복합레진의 선형중합수축 측정의 새로운 방법)

  • Lee, In-Bog;Min, Sun-Hong;Seo, Deog-Gyu;Kim, Sun-Young;Kwon, Young-Chul
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.3
    • /
    • pp.180-187
    • /
    • 2010
  • Since the introduction of restorative dental composites, their physical properties have been significantly improved. However, polymerization shrinkage is still a major drawback. Many efforts have been made to develop a low shrinking composite, and silorane-based composites have recently been introduced into the market. In addition, many different methods have been developed to measure the polymerization shrinkage. In this study, we developed a new method to measure the linear polymerization shrinkage of composites without direct contact to a specimen using a particle tracking method with computer vision. The shrinkage kinetics of a commercial silorane-based composite (P90) and two conventional methacrylate-based composites (Z250 and Z350) were investigated and compared. The results were as follows: 1. The linear shrinkage of composites was 0.33-1.41%. Shrinkage was lowest for the silorane-based (P90) composite, and highest for the flowable Z350 composite. 2. The new instrument was able to measure the true linear shrinkage of composites in real time without sensitivity to the specimen preparation and geometry.

Method for Rapid Determination and Removal of Nitrogen Oxides in Flue Gases (Ⅰ). Rapid Determination on Nitrogen Oxides (배기가스중 질소산화물의 신속측정법과 그 제거에 관한 연구 (제1보). NO$_x$의 신속 정량법)

  • Yong Keun Lee;Tong Oh Seo;Kee Jung Paeng;Man Koo Kim;Kyu Ja Whang
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.1
    • /
    • pp.52-60
    • /
    • 1985
  • Oxides of nitrogen (NO$_x$) in exhaust gases was determined by absorbing the gas in alkaline peroxide solution containing 0.03${\%}$ H2O2 and 0.1N NaOH. About 100 ppm of NO$_x$ was rapidly oxidized to NO$_2$ or N$_2$O$_5$ by H$_2$O$_2$ and required a contact time of 2 minutes with the absorbing solution for complete absorption. With vigorous shaking including air or oxygen gas, high concentration of NO$_x$ (>200 ppm) can be absorbed within 30 minutes. The remaining H$_2$O$_2$ affect the absorbance of color solution strongly. However, the excess H$_2$O$_2$ was completely decomposed by zinc powder 0.5g and the sample solution should be adjusted to the pH range 6.1∼6.6 before the reduction so that conversion of nitrate to nitrite ion is possible. The absorbed NO$_x$ is determined colorimetrically by the diazotization-coupling method with sulfonilamide and NEDA as the coupling agent. The sensitivity of the new method was 4.48 ${\times}$ 10$^4$ as molar absorptivity which was high sensitive compared with that obtained for the usual zinc reduction NEDA method with O$_3$. This method was far more rapid, brief and accurate than previously published O$_3$-NEDA method in Korean industrial standard.

  • PDF

Study of dynamic mechanical behavior of aluminum 7075-T6 with respect to diameters and L/D ratios using Split Hopkinson Pressure Bar (SHPB)

  • Kim, Eunhye;Changani, Hossein
    • Structural Engineering and Mechanics
    • /
    • v.55 no.4
    • /
    • pp.857-869
    • /
    • 2015
  • The aluminum 7075-T6 is known as an alloy widely used in aircraft structural applications, which does not exhibit strain rate sensitivity during dynamic compressive tests. Despite mechanical importance of the material, there is not enough attention to determine appropriate sample dimensions such as a sample diameter relative to the device bar diameter and sample length to diameter (L/D) ratio for dynamic tests and how these two parameters can change mechanical behaviors of the sample under dynamic loading condition. In this study, various samples which have different diameters of 31.8, 25.4, 15.9, and 9.5 mm and sample L/D ratios of 2.0, 1.5, 1.0, 0.5, and 0.25 were tested using Split Hopkinson Pressure Bar (SHPB), as this testing device is proper to characterize mechanical behaviors of solid materials at high strain rates. The mechanical behavior of this alloy was examined under ${\sim}200-5,500s^{-1}$ dynamic strain rate. Aluminum samples of 2.0, 1.5 and 1.0 of L/D ratios were well fitted into the stress-strain curve, Madison and Green's diagram, regardless of the sample diameters. Also, the 0.5 and 0.25 L/D ratio samples having the diameter of 31.8 and 25.4 mm followed the stress-strain curve. As results, larger samples (31.8 and 25.4 mm) in diameters followed the stress-strain curve regardless of the L/D ratios, whereas the 0.5 and 0.25 L/D ratios of small diameter sample (15.9 and 9.5 mm) did not follow the stress-strain diagram but significantly deviate from the diagram. Our results indicate that the L/D ratio is important determinant in stress-strain responses under the SHPB test when the sample diameter is small relative to the test bar diameter (31.8 mm), but when sample diameter is close to the bar diameter, L/D ratio does not significantly affect the stress-strain responses. This suggests that the areal mismatch (non-contact area of the testing bar) between the sample and the bar can misrepresent mechanical behaviors of the aluminum 7075-T6 at the dynamic loading condition.

A Study for the Adaptation of Simulation of Uniaxial Compressive Strength Test for Concrete in 3-Dimensional Particle Bonded Model (3차원 입자 결합 모델에서 콘크리트의 일축압축실험 모사 적용성 연구)

  • Lee, Hee-Kwang;Jeon, Seok-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.2
    • /
    • pp.147-156
    • /
    • 2008
  • In an uniaxial compressive test of a concrete standard specimen (150$\times$300 mm) the crack initiation and extension with the stress increase are the major reason of the failure, which is similar to the breakage of the particle bonding in the simulation by using particle bonded model, especially particle flow code in 3 dimensions (PFC3D) developed by Itasca Consulting Group Inc. That is the main motive to study the possibility of an uniaxial compressive strength test simulation. It is important to investigate the relationship between the micro-parameters and the macro-properties because the 3-dimensional particle bonded model uses the spherical particles to analyze the physical phenomena. Contact bonded model used herein has eight micro-parameters and there are five macro-properties; Young's modulus, Poisson's ratio, uniaxial compressive strength and the crack initiation stress and the ratio concerning the crack propagation with the stress. To simulate the compressive test we made quantitative relationships between the micro-parameters and the macro-properties by using the fractional factorial design and various sensitivity analyses including regression analysis, which result in the good agreement with the previous studies. Also, the stress-stain curve and the crack distribution over the specimen given by PFC3D showed the mechanical behavior of the concrete standard specimen under the uniaxial compression. It is concluded that the particle bonded model can be a good tool for the analyzing the mechanical behavior of concrete under the uniaxial compressive load.

Risk factors for hospital admission in revisiting patients to the emergency department with abdominal pain

  • Bae, Jung Kwang;Kim, Hye Jin;Ryu, Seokyong;Choi, Seung Woon;Kang, Tae Kyung;Oh, Sung Chan;Cho, Suk Jin;Lee, Sun Hwa
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.6
    • /
    • pp.679-686
    • /
    • 2018
  • Objective: The aim of this study was to identify the clinical characteristics and risk factors associated with the admission of patients in the emergency department (ED) within 30 days after discharge. Methods: A retrospective, observational study was conducted on adult patients presenting with abdominal pain to the ED of a single, urban, university hospital, between January 2014 and December 2015, who revisited the ED within 30 days after discharge. Data was collected on the emergency severity index level, time to contact doctors, physical examination, laboratory tests, use of computed tomography (CT), and patient disposition on revisitation. The primary outcome was hospital admission following an ED revisit in the 30-day period after the first visit. Results: During the study period, 19,480 patients visited the ED with the chief complaint of abdominal pain, and 13,577 were discharged. A total of 251 patients (1.29%) revisited the ED within 30 days, of which 89 were eligible for the study. The primary outcome was associated with not performing a CT scan on the initial visit and an increased C-reactive protein (CRP) value. Receiver operating characteristic curve analysis showed that a cut-off baseline CRP value of >0.35 mg/dL can predict the primary outcome with a sensitivity and specificity of 75% and 62.1%, respectively (area under the curve, 0.701; 95% confidence interval, 0.569-0.833; P=0.007). Conclusion: An increased CRP value and not performing abdominal CT were associated with a higher rate of admission following ED revisits of patients with abdominal pain. Future prospective studies on the role of abdominal CT imaging in patients presenting to the ED with abdominal pain will be needed.

Evaluation of Water Quality Change by Membrane Damage to Pretreatment Process on SDI in Wastewater Reuse (하수재이용에서 전처리 막 손상에 의한 수질변화가 SDI에 미치는 영향평가)

  • Lee, Min Soo;Seo, Dongjoo;Lee, Yong-Soo;Chung, Kun Yong
    • Membrane Journal
    • /
    • v.32 no.4
    • /
    • pp.253-263
    • /
    • 2022
  • This study suggests a guideline for designing unit process of wastewater reuse in terms of a maintenance of the process based on critical parameters to draw a high quality performance of RO unit. Defining the parameters was done by applying membrane integrity test (MIT) in pretreatment process utilizing lab-scale MF. SDI is utilized for judging whether permeate is suitable to RO unit. However, result said TOC concentration matching with particle count analysis is better for judging the permeate condition. When membrane test pressure (Ptest) was measured to derive log removal value in PDT, virgin state of membrane fiber was used to measure dynamic contact angle utilizing surface tension of the membrane fiber. Actually, foulant affects to the state of membrane surface, and it decreases the Ptest value along with time elapsed. Consequently, LRVDIT is also affected by Ptest value. Thus, sensitivity of direct integrity test descends with result of Ptest value change, so Ptest value should be considered not the virgin state of the membrane but its current state. Overall, this study focuses on defining design parameters suitable to MF pretreatment for RO process in wastewater reuse by assessing its impact. Therefore, utilities can acknowledge that the membrane surface condition must be considered when users conduct the direct integrity test so that Ptest and other relative parameter used to calculate LRVDIT are adequately measured.

Dry Weight Singularity Analysis of Rock Specimen Depending on Temperature (온도에 따른 암석시편의 건조무게 특이점 분석)

  • Sukjoo Kim
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.9
    • /
    • pp.25-32
    • /
    • 2023
  • The Korean Industrial Standards (KS F) have a various regulations for measuring the weight of dried soil and rock. However, if the dried weight is measured in air after drying at 110±5℃ or 105±5℃, a weight singularity occurs, in which the weight decreases and then increases as the measurement time continues. In this study, basaltic rock from Ulleung Island was oven dried at 40 to 110℃. The weight was measured on an electronic scale with a sensitivity of 0.0001g (0.1mg) to find weight singularities. A method to easily determine the dry weight using the weight singularities was presented. As a result of analyses of the singularity of rock specimen according to temperature, the singularities were appeared in the temperature range of 40 to 110℃, and the weight of the singularity was smaller as the heating temperature increased. In particular, the weight singularity duration appeared, and the duration of the singularity was shorter as the heating temperature increased. The results of the convection measurement experiment showed that the cause of the singularity is the convection phenomenon caused by the contact of the heated rock with the air. The weight decrease of oven dried rock occurs when the effect of convection is dominant over the effect of air moisture absorption. Conversely, the weight increase of rock occurs when the effect of air moisture absorption is dominant over the effect of convection.

Rehabilitation with minimal increase in occlusal vertical dimension in a patient with excessive tooth wear and edge-to-edge bite (과도한 치아 마모와 절단교합을 보이는 환자에서 최소한의 수직 고경 증가를 통한 구강회복 증례)

  • Hee-Young Kim;Seong-A Kim;Yong-Sang Lee;Keun-Woo Lee;Joo-Hyuk Bang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.143-152
    • /
    • 2023
  • Although tooth wear is a normal process due to aging, severe tooth wear causes various complications such as increased tooth sensitivity, loss of tooth structure, and pulp complications. In the treatment of patients with excessive tooth wear, the evaluation of loss of vertical occlusal dimension should be prioritized. If it is necessary to increase the vertical dimension to secure the restoration space, it is important to establish a treatment plan with the comprehensive analysis and determine the minimum vertical dimension elevation. In this case, 66-year-old male patient with severe worn dentition wanted to restore masticatory function and improve esthetic restoration. In order to determine the appropriate vertical dimension of the patient, we evaluated oral examination, radiographic examination, and diagnostic cast examination, and performed rehabilitation with minimum vertical dimension elevation. As a result of observation for 8 months, the definitive prosthesis was completed with contact of all teeth in centric occlusion, and proper anterior/posterior guidance. Through the above process, satisfactory aesthetic and functional outcomes were obtained.