• Title/Summary/Keyword: Consumption power

Search Result 5,992, Processing Time 0.09 seconds

Improved Side Channel Analysis Using Power Consumption Table (소비 전력 테이블 생성을 통한 부채널 분석의 성능 향상)

  • Ko, Gayeong;Jin, Sunghyun;Kim, Hanbit;Kim, HeeSeok;Hong, Seokhie
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.27 no.4
    • /
    • pp.961-970
    • /
    • 2017
  • The differential power analysis calculates the intermediate value related to sensitive information and substitute into the power model to obtain (hypothesized) power consumption. After analyzing the calculated power consumption and measuring power consumption, the secret information value can be obtained. Hamming weight and hamming distance models are most commonly used power consumption model, and the power consumption model is obtained through the modeling technique. If the power consumption model assumed by the actual equipment differs from the power consumption of the actual equipment, the side channel analysis performance is declined. In this paper, we propose a method that records measured power consumption and exploits as power consumption model. The proposed method uses the power consumption at the time when the information (plain text, cipher text, etc.) available in the encryption process. The proposed method does not need template in advance and uses the power consumption measured by the actual equipment, so it accurately reflects the power consumption model of the equipment.. Simulation and experiments show that by using our proposed method, side channel analysis is improved on the existing power modeling method.

The Forecasting Power Energy Demand by Applying Time Dependent Sensitivity between Temperature and Power Consumption (시간대별 기온과 전력 사용량의 민감도를 적용한 전력 에너지 수요 예측)

  • Kim, Jinho;Lee, Chang-Yong
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.42 no.1
    • /
    • pp.129-136
    • /
    • 2019
  • In this study, we proposed a model for forecasting power energy demand by investigating how outside temperature at a given time affected power consumption and. To this end, we analyzed the time series of power consumption in terms of the power spectrum and found the periodicities of one day and one week. With these periodicities, we investigated two time series of temperature and power consumption, and found, for a given hour, an approximate linear relation between temperature and power consumption. We adopted an exponential smoothing model to examine the effect of the linearity in forecasting the power demand. In particular, we adjusted the exponential smoothing model by using the variation of power consumption due to temperature change. In this way, the proposed model became a mixture of a time series model and a regression model. We demonstrated that the adjusted model outperformed the exponential smoothing model alone in terms of the mean relative percentage error and the root mean square error in the range of 3%~8% and 4kWh~27kWh, respectively. The results of this study can be used to the energy management system in terms of the effective control of the cross usage of the electric energy together with the outside temperature.

Characteristics of Energy Consumption in an Office Building located in Seoul (사무소건물의 용도 및 측정기간에 따른 에너지 소비 특성)

  • Park Byung-Yoon;Chung Kwang-Seop
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.82-87
    • /
    • 2005
  • The purpose of this study is to suggest the characteristics and actual state of energy consumption by the analysis of energy consumption data in an office building. This study examines and analyzes daily and monthly energy consumption of an office building located in Seoul, Korea regarding type of load and business classification within a building. The results are as follows. 1) Energy consumption of office building for each type of load show similar consumption patterns, regardless of seasons such as cooling period and heating period. 2) Out of all annual energy consumption, consumption for lighting took about $43\;\%,$ general electric Power about $23\;\%,$ emergency power $25\;\%,$ computer center $5\;\%$ and cooling power $4\;\%,$ showing that the consumption for lighting was highest, and the percentage of energy consumption for cooling power for operation of cooling facilities took the lowest percentage. 3) Annual gas consumption used for heating and hot water supply were $38,\;36\;\%$ for officetel and office respectively, and $26\;\%$ for arcade. 4) Electricity consumptions used for cooling power for each use of building, office and officetel recorded in July and August of cooling seasons. Even though it shows different patterns for each month, energy consumption showed unique pattern throughout the cooling seasons.

Study on the Power Consumption Characteristics of Korean Domestic Species in Peripheral Milling with Image Analysis Technique

  • Lee, Hyoung Woo;Kim, Byung Nam;Kim, Kyung Yong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.5 s.133
    • /
    • pp.38-44
    • /
    • 2005
  • Peripheral milling is one of the most important wood machining processes in wood industry. Power consumption characteristics of twelve Korean domestic species in peripheral milling were investigated in this study. Image analysis technique was applied to extract proper data from the power consumption profiles. Average power consumption increased as cutting depth increased and specific cutting power decreased as cutting depth increased. However, no significant relationship could be found between density and power consumption and between cutting depth and surface roughness.

BMT-Model Based Evaluation of Power Consumption of Mobile Context-Aware Application (BMT 모델 기반 모바일 상황인지 어플리케이션의 전력 소비 평가)

  • Jeon, Jaehong;Baek, Dusan;Kim, Kyung-Ah;Lee, Jung-Won
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.5 no.11
    • /
    • pp.411-418
    • /
    • 2016
  • Context-aware application has a lot of power consumption because it creates context by using a number of smartphone's sensors. Furthermore, only few kinds of researches have been conducted that provide information for the evaluation result of power consumption in the aspect of applications. In addition, evaluation of power consumption do not consider user's usage pattern or provide only total amount of power consumption, and inform developers power consumption of sensors undistinguishable. It makes developers hard to develop a power consumption-considered application. If developers could get information for power consumption of context-aware application in detail, a development of power-considered context-aware applications would be possible. Consequently, this paper proposes a BMT(Bench Mark Test) model which is able to inform developers useful evaluation criteria and result about power consumption of smartphone's components and sensors with usage pattern considered.

The Characteristic of TEC Power Consumption of Laser Diode Module (레이저다이오드 모듈 냉각용 TEC 소비전력 특성)

  • Lee Jong Jin;Yu Chong Hee;Kang Hyun Seo;Koh Jai Sang
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.3 s.32
    • /
    • pp.71-76
    • /
    • 2004
  • The power consumption of TEC for Laser diode cooling was predicted by 3-D FEM simulation and verified by experiment. The operating conditions such as power consumption of Laser diode, set temperature, ambient temperature, resistance of thermal path was considered to estimate the TEC power consumption. Using 3-D FEM simulation, the relation between TEC configuration defined by the pellet dimension and the number and power consumption was investigated for low power consumption scheme. As a result, as the thermal resistance of the pellet increased, the power consumption decreased.

  • PDF

Correlation Between Meteorological Factors and Hospital Power Consumption (기상요인과 병원 전력사용량의 상관관계)

  • Kim, Jang-Mook;Cho, Jung-Hwan;Kim, Byul
    • Journal of Digital Convergence
    • /
    • v.14 no.6
    • /
    • pp.457-466
    • /
    • 2016
  • To achieve eco-friendly hospitals it is necessary to empirically verify the effect of meteorological factors on the power consumption of the hospital. Using daily meteorological big data from 2009 to 2013, we studied the weather conditions impact to power consumption and analyzed the patterns of power consumption of two hospitals. R analysis revealed that temperature among the meteorological factors had the greatest impact on the hospital power consumption, and was a significant factor regardless of hospital size. The pattern of hospital power consumption differed considerably depending on the hospital size. The larger hospital had a linear pattern of power consumption and the smaller hospital had a quadratic nonlinear pattern. A typical pattern of increasing power consumption during a hot summer and a cold winter was evident for both hospitals. The results of this study suggest that a hospital's functional specificity and meteorological factors should be considered to improve energy savings and eco-friendly building.

Study on the Low Power Service with User State Recognition Algorithm Using Sensors (센서 기반 사용자 상태 인식 알고리즘을 이용한 저전력 서비스에 관한 연구)

  • Lee, Do-Kyeong;Hong, Won-Kee;Cha, Kyung-Ae
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.10 no.2
    • /
    • pp.91-99
    • /
    • 2015
  • The electric power consumed by the embedded devices has become a critical issue because the reduction of power consumption is an important factor to prolong the battery-operated devices' lifetime. Many researches and techniques to reduce the power consumption have been proposed and developed but any power method cannot guarantee optimal power consumption of an embedded device - it would be faced with numerous situation - in all ways. Specifically, power researches for embedded devices deployed in the industry field have hardly been done. In this paper, low power service is proposed to minimize power reduction with the several usage status of embedded devices in the industry field. The usage status is basically classified according to the distance between the device and the user which is obtained by the ultrasonic and PIR sensor. The performance evaluation shows that the proposed scheme can reduce the power consumption by up to 45.3% compared to the device with no power reduction scheme. It also shows that the power consumption of the proposed scheme is 5.2% ~ 16.8% lower than that of the timeout scheme.

Circuit Techniques for Low-Power Data Drivers of TFT-LCDs

  • Choi, Byong-Deok;Kwon, Oh-Kyong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.3
    • /
    • pp.167-181
    • /
    • 2001
  • A stepwise driving method was used for reducing the AC power consumption in a TFT-LCD. The AC power takes the largest portion of the total power consumption of a TFT-LCD. Experimental results confirmed that the AC power saving efficiency reached up to 75% when a 5-stepwise driving with each step time of $2\mu$ sec was applied to a 14.1 inch-diagonal XGA TFT-LCD. The second largest component of power consumption called the DC power comes from the quiescent currents in Op-amps. A simple and efficient architecture was proposed in this work to reduce this DC power consumption: Half of the Op-amps have the 5V-supplies, and the rest half have the 10V-supplies, and two Op-amps are shared by adjacent two channels. Measurements of test circuits showed that this simple method could reduce over 40% of the DC power consumption..

  • PDF

Analysis of Power Pattern According to Load Types (부하 형태에 따른 전력패턴 분석)

  • Mi-Yong Hwang;Seung-Joon Cho;Soon-Hyung Lee;Yong-Sung Choi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.4
    • /
    • pp.369-375
    • /
    • 2023
  • In this paper, we compared and analyzed the power load patterns of dormitory buildings and office buildings to use them as basic data (demand analysis and capacity design) for the design and operation of microgrids for multi-use facilities, and the following conclusions were got. During the daytime on regular weekdays, the power consumption load pattern of office buildings was relatively large at 264.0~332.3 kWh, and during the evening hours, the power consumption load pattern of dormitory buildings was relatively large at 233.0~258.3 kWh. In the case of vacation, during the daytime on weekdays, the power consumption load pattern of office buildings was relatively large at 279.1~407.4 kWh, and in the evening, the power consumption load pattern of dormitory buildings was relatively high at 280.1~394.1 kWh. During the daytime on regular weekends, the power consumption of dormitory-type buildings was relatively high at 133.5~201.6 kWh, and it was found that the power consumption of dormitory-type buildings appeared relatively high at 187.5~252.1 kWh. During a vacation in the daytime on weekends, the power consumption of dormitory-type buildings was found to be 186.5 kWh~ and 218.6 kWh. The increase in power consumption during a vacation (December-February) compared to normal (April-June) was thought to be due to an increase in electricity demand, and the reason for the higher power consumption in dormitory buildings during the vacation was due to reduced working hours in office buildings.