• Title/Summary/Keyword: Construction waterproofing

Search Result 337, Processing Time 0.027 seconds

Study on the Application of Site for Exposure Type of Complex Waterproofing Method with Liquefied Waterproof using of Vertical Type Reinforcing Sheet Material Reinforced Sheet Rising System in the Roof Tops (돌기 시스템을 이용한 입체보강형시트의 옥상노출복합방수공법 적용에 관한 재료 및 공법적 연구)

  • Oh, Sang-Keun;Son, Mum-Se;Kim, Jin-Seong;Yeo, In-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.6 no.4 s.22
    • /
    • pp.69-75
    • /
    • 2006
  • It often happen water leakage that roof membrane have a poor condition such as direct exposed to rain, ultraviolet lays, temperature change compare with other part of waterproofing. There are difficult to maintain the quality of waterproofing and durability due to use only few waterproofing materials in practical in spite of development and use the various waterproofing material as solution of these poor condition. Therefore, in this thesis, I would like to know the property to apply field and suggest other method to develop for this waterproofing method to adopt various field condition for roof tops, as searching exposed and complex waterproofing technology for roof tops which is reinforced sheet using rising system have a regular pitch, depth, space.

Tensile Adhesive Chracteristics of Waterproofing System for Concrete Bridge Decks (교량 바닥판 조건에 따른 교면방수 시스템의 인장접착 특성)

  • Lee, Byung-Duck;Shim, Jae-Won;Park, Sung-Ki;Kim, Kwang-Woo
    • International Journal of Highway Engineering
    • /
    • v.4 no.3 s.13
    • /
    • pp.15-23
    • /
    • 2002
  • The waterproofing system's performance is known to show a determing by complex interaction of material factors, design details, and the quality of construction, and the waterproofing integrity of waterproofing membranes is determined by the bond to the deck and the amount of damage to the waterproofing membrane. In this research, the basic properties of waterproofing membranes on market and the tensile adhesive chracteristics of waterproofing systems of concrete bridge deck have also been investigated in the view of the damages frequently reported from job site. For the tensile adhesive strength of sheet waterproofing membranes, the results after asphalt concrete paving tends to increase more than before those. The results of the liquid waterproofing membranes are upside-down, and the more concrete has strength, the more strength of tensile adhesive increase. The ambient temperature of asphalt concrete when application of the waterproofing membrane has considerable influence on the performance of waterproofing system. As described above, waterproofing system can be influenced by several factors. If they are not considered under construction, the overlooking will cause the damages of pavement and waterproofing system after traffic opening.

  • PDF

An Study on the Development of Waterproofing Execution Technology With high Temperature and Spray Equipments of Piston Type (피스톤 방식의 고온·고압 뿜칠장치를 이용한 방수 시공 기술 공법에 관한 연구)

  • Moon, You-Seok;Choi, Eun-Gyu;Choi, Sung-Min;Gwak, Gyu-Sung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.7-12
    • /
    • 2008
  • We constructed Seal type waterproofing with adhesive and swelling properties in the field of construction work as yet. But we have many problems of seal type waterproofing with adhesive and swelling properties for construction. Because it has high viscosity, so wokers are too adhered for the work. So, we developed and applied about the high temperature and spray equipments of piston type better than before. We able to be expect that cost reduction and increase construction ability by high temperature and spray equipments of piston type.

  • PDF

Waterproofing and Root Barrier Construction Design for Artificial Green Roof System of Residential Apartment Underground Parking Lots (공동주택 지하주차장 상부 인공지반녹화층 방수 및 방근 설계 방안)

  • Lee, Jung-Hun;Kim, Bum-Soo;Song, Je-Young;Kim, Soo-Yeon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.337-338
    • /
    • 2018
  • In recent years, residential apartment building parking lots are built in underground spaces, and with conjunction to improve the environment of the urban area, artificial greeen roof systems are installed on the upper slabs. However, early plant growth are resulting in root penetration into concrete cracks and in turn into the waterproofing membranes, leading to degradation and damaging of the waterproofing system and structural durability. This issue highlights a problem of conventional maintenance system of concrete structures, and proposals for amendments follow. In this study, a waterproofing and root barrier construction design for the upper slabs of residential building underground parking lots is proposed, and motioned to be added into future construction specifications.

  • PDF

A Study on Waterproofing and Anticorosive Performance Evaluation of Surface treatment material used wi th Glass Fiber, Inorganic and Organic Material for Water Tank (수조구조물의 방수.방식 공사용 유기.무기 소재 및 섬유보강형 바탕처리재의 성능평가에 관한 연구)

  • 오상근;박봉규;주웅일;박성진
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.70-75
    • /
    • 2001
  • There is a problem to be solved for improvement of durability and safety for concrete When the waterproofing and anticorrosive work of main concrete are design, the material a of construction need to be correctly applied to appropriate circumstance conditions. Epoxy mostly been used for concrete water tank structure. Lately, lots of subjects on adaption res in mortar for waterproofing and anticorrosive are under discussion. Then, we attempt to approach by evaluating and comparing every capabilities with waterproofing materials in this experiment. Capability evaluation items include the bond age and curing conditions, the bond strength after accelerated weathering test and fret impact resistance, a mount of water, seepage quan Through the experiment analysis, we found that waterproofingtity, drinking water chemicals resistance. and anticorrosive resin mortar used with glass fiber cloth, inorgar material is dominantly superior to other waterproofing materials. According to this paper, we suggest the resin mortar as a new surface treatment material water tank structure.

  • PDF

Research on Change of Tensile Strength with Joint Distance and Form in the Roof Composite Waterproofing Method for Synthetic Polymer Waterproofing Sheet (합성고분자계 방수시트를 이용한 옥상 복합방수공법의 접합부 이격거리 및 형태별 인장성능 변화에 관한 연구)

  • Go, Gun-Woong;Heo, Neung-Hoe;Kim, Yun-Ho;Park, Jin-Sang;Song, Je Young;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.65-67
    • /
    • 2012
  • The butt-joint system is widely used as the method of roof composite waterproofing system. However, there is stilll no objective research about proper distance, and proper structure associated with the performance in butt-joint system. In this research, we find proper distance and proper structure in butt-joint system through tensile strength test at joint, and comparative analyze with practical construction material of composite waterproofing sheet.

  • PDF

An Experimental Study on the Roofing Waterproofing Method Combined Soft and Hard Rapid Hardening Membrane (연질 및 경질 초속경도막방수재를 복합화한 옥상노출방수공법에 관한 실험적 연구(균열 대응성))

  • Choi, Eun-Gyu;Seo, Hyun-Jae;Lee, Jung-Hun;Lee, Sun-Gyu;Song, Je-Young;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.177-178
    • /
    • 2018
  • In the case of conventional ultra-fast hardness membrane waterproofing material (polyurea, etc.), damage such as breakage or tearing occurred frequently at the time of cracking of the surface after waterproofing. In this study, it is suggested that a waterproof layer can not cope with the occurrence of cracks at the same time by applying the soft type waterproofing material of soft type at the lower part of the construction method (securing of elongation) To minimize the possibility of water resistance.

  • PDF

Constructability of a Waterproofing Sheet Joint Combining an Aluminum Thin-film and Viscosity Layer Using a High-frequency Inductive Heating Apparatus (고주파 유도가열 장치를 이용한 알루미늄 박판 점착 복합방수시트 조인트부의 시공성)

  • Chang, Sang Mook;Kim, Yun Ho;Choi, Sung Min
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.2
    • /
    • pp.163-169
    • /
    • 2014
  • Engineers in the construction field have been using bonded waterproofing sheets in an attempt to resolve the imbalance in the quality, the risk of fire, safety of workers, and environmental pollution, as well as to eliminate separate use of organic adhesives on the surface of concrete. Recently, self-laminated waterproofing sheets have been developed. The purpose of this research is to find an appropriate processing speed according to the changes in physical properties, and visual observation of the waterproofing sheets laminated by the aluminum thin-film and viscosity layer that can be attached through self-adhesiveness on the surface of concrete and waterproofing sheets. Therefore, this research is conducted using a physical performance test. Based on the result of the test, when the high-frequency inductive heating apparatus was used, an improved adhesion and bonding stability effect were confirmed after the anti-hydrostatic pressure and bond strength in the temperature condition, and the surface observation in the processing speed condition.

An Experimental Study of Water Vapor Pressure that occurs at the Interface of a Fluid-Applied Membrane and Concrete (콘크리트와 도막 방수층 계면에 발생되는 수증기압에 관한 실험적 연구)

  • Ko, Jin-Soo;Kim, Mun-Hee;Lee, Sung-Bok;Shin, Yun-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.147-150
    • /
    • 2006
  • Of the total defects that have occurred recently in the Korean construction market, over 30% are caused by the construction of defective waterproofing, and the phenomenon of air pockets in the waterproofing layer, which is caused by the concrete vapor pressure, is known to be the primary cause of defective waterproofing. Accordingly, in this study the theory about the relationship between water pressure and temperature as well as the damp-proofing volume of concrete and, then, the change of vapor pressure volume was measured and analyzed by making a test sample after spraying a dampness remover and a waterproofing material to a prepared test body. As a result of measuring the water vapor pressure for the surface temperature of the waterproofing layer with the fluid-applied membrane temperature based on about $10^{\circ}C$, which is the average temperature of Seoul, it was found that first, the fluid-applied membrane elevated up to about $40^{\circ}C$, and the water vapor pressure generated from the fluid-applied membrane was about $0.3kgf/cm^2$ when the surface temperature of the waterproofing layer was raised up to about $80^{\circ}C$. Second, when the fluid-applied membrane temperature of the waterproofing layer was raised from $30^{\circ}C\;to\;35^{\circ}C,\;about\;0.1kgf/cm^2$ of water vapor pressure was generated, and when supplying a thermal source to raise the fluid-applied membrane temperature of the waterproofing layer from $35^{\circ}C\;to\;40^{\circ}C$, approximately $0.05kgf/cm^2$ of water vapor pressure was generated.

  • PDF

A Study on Changes of Physical Properties of Rooftop Exposed Waterproofing PVC Sheet based on Longterm Outdoor Exposure Testing with Bearings (North, South) (옥상 노출방수용 PVC 방수시트의 방위별(남, 북) 장기옥외폭로에 따른 물성 변화 연구)

  • An, Ki-Won;Moon, You-Seok;Kim, Chun-Hag;Song, Je-Young;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.147-148
    • /
    • 2015
  • Exposed type waterproofing PVC sheets installed on structure rooftops are subject to changes in physical properties after longterm exposure to sunlight. Particularly when consideration the rotational movement of sunlight over the day through the course of the sun rising from the east and setting in the west, in the case of flat roofs the amount of UV ray the the surface of the PVC waterproofing sheet receives may be even throughout, but in cases of slanted rooftops the sunlight exposure may be uneven across the surface. In this regard, this study examines the effect uneven sunlight exposure on the exposed type waterproofing PVC sheets installed on slanted rooftops.

  • PDF