• Title/Summary/Keyword: Construction level

Search Result 4,375, Processing Time 0.034 seconds

Analysis of Flood Control Effect by Applying the Connecting Channel in Estuary Area Including the Confluence of Two Rivers (2개의 하천이 합류하는 하구역에서의 연결수로 통수능에 따른 홍수위저감효과 분석)

  • Kim, Sooyoung;Kim, Hyung-Jun;Yoon, Kwang Seok
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.12
    • /
    • pp.1065-1075
    • /
    • 2015
  • In the estuary where the structure such as river-mouth weir has been installed, the flow is developed very complicatedly due to river water from upstream, tide of the sea and floodgate operation. Especially, if basin outlets more than one exists in one estuary, the boundary conditions will be significantly more complex form. Saemangeum(SMG) project area in Korea is the most typical example. There are Mankyung river and Dongjin river in upstream. The water of them inflows into SMG project area. In the downstream, river flow was drained from inland to sea over the SMG sea dike through the sluice. The connecting channel was located between Mankyung and Dongjin basins. It functions not only as transportation by ship in ordinary period but also as flood sharing by sending flood flow to each other in flood period. Therefore, in order to secure the safety against flood, it is very important to understand the flood sharing capacity for connecting channel. In this study, the flood control effect was analyzed using numerical simulation. Delft3D was used to numerical simulation and simulated period was set up with neap tide, in which the maximum flood stage occurred due to poor drainage. Actually, three connecting channels were designed in land use plan of the SMG Master Plan, but they were simplified to a single channel for conciseness of analysis in this study. According to the results of numerical analysis, the water level difference between two basins was increased and the maximum flood stage at dike sluice was also upraised depending on decrease of conveyance. And the velocity induced by same water level difference was decreased when the conveyance became smaller. In certain conveyance above, there was almost no flood control effect. Therefore, if the results of this study are considered for design of connecting channel, it will be expected to draw the optimal conveyance for minimizing dredging construction cost while maximizing the flood control effect.

The Study on the Prediction of Algae Occurrence by the Multiple Regression Analysis After Weir Construction at Namhan River (다중회귀분석을 이용한 남한강 내 보 건설 후 조류 발생량 예측)

  • Oh, Seung-Eun;Ahn, Hong-Kyu;Chae, Soo-Kwon
    • Journal of Environmental Impact Assessment
    • /
    • v.26 no.6
    • /
    • pp.470-478
    • /
    • 2017
  • This study was classified into two groups, normal season group and drought season group, by the cluster analysis using the weather and water quality data from 2012 to 2015, using SPSS 18 version. Also each cluster was classified into three spaces, Gangcheon, Yeoju and Ipoh weir. We performed the multiple regression analysis with each monthly data that concentration of Chl-a was more than algae warming level. 6 groups classified in time and space were analyzed by the correlation analysis between concentration of Chl-a and 3 weather, 11 water quality and discharge factors. We developed Chl-a prediction equations of each group with independent variables of the multiple regression analysis applying to the correlation result. The result of cluster analysis was that the period was divided into two groups, normal group(2012-2013) that total annual precipitation rate was normal and drought group(2014-2015) that total annual precipitation rate was less than 1,000 mm/hr, in time. The months that concentration of Chl-a was more than algae warming level in each group classified by cluster analysis were that the normal group was 3~8 and drought group was 3 and 6~10. The correlation result between Chl-a and weather, water quality and discharge factors for each 6 group was that relationships between Chl-a and water, discharge factors were high in the drought group more than in normal group at all weirs. This was influenced by velocity reduction and increasing HRT according to the intense drought. Weather, water quality and discharge factors that were high correlation with Chl-a were applied to independent variables of Chl-a prediction equations and each equations were developed. Among them, Each adjusted R square of Prediction equations for Chl-a in each group at Ipoh weir where is located in Namhan river downstream and is directly connected to Paldang dam were normal group = 0.920 and drought group = 0.818. It's showed the high linear.

Hydrogeochemical Characteristics and Contamination of Dissolved Major ions and Heavy Metals in Waters and Sediments from the Tancheon River (탄천의 하상퇴적물과 하천수내 주요 용존 이온과 중금속의 수리지구화학적 특성과 오염)

  • 이성은;김규한;이진수;전효택
    • Economic and Environmental Geology
    • /
    • v.35 no.1
    • /
    • pp.25-41
    • /
    • 2002
  • In order to investigate the hydrogeochemical characteristics and contamination of dissolved major ions and heavy metals in the Tancheon River, river water and sediment samples were collected at 18 locations, along a distance of 69 km, between Yongin-si in Kyunggi-do and Samsung-dong in Seoul on October in 2000 and April in 2001. After appropriate sample preparation, waters were analyzed for the dissolved constituents and sediments. The pH values of river waters were in the range of 7.0 to 9.3 and could be plotted in the area of surface environment. The level of $Ca^{2+}$, , CI-, sol-, N0$_{3}$ and HC0$_{3}$ in the Tancheon River were higher than those in world average river water. Most of dissolved constituents in the river waters increased toward downstream from upstream. In particular, high concentrations of Zn2+, Na$_{+}$, CI$^{-}$, SO$_{4}^{2-}$ and N03- were found near densely residential areas and the Sungnam waste water treatment plant. The relative ion enrichment was caused by the inflow of local domestic and industrial sewages. Also, Ca2+ and HC03- concentrations were enriched in the middle of the Tancheon River due to the dissolution of cements. This indicates that the apartment complexes were built on a large scale in the upriver since these ten years and large amounts of construction materials such as cements were flowed into the Tancheon River. Concentrations of heavy metals (Mn, Cd, Cu, Pb, Zn) in sediments from the Tancheon River exceeded the lower limit of tolerence level in bottom sediment established by the Ontario Ministry of the Environment (OME) of Canada. In particular, these metals were highly elevated in sediment (TSM-12) collected from near the Sungnam waste water treatment plant. Heavy metals were higher enriched in sediments collected from dry period rather than wet period.

The Construction and Application of Planning Support System for the Sustainable Urban Development (지속가능한 도시개발을 위한 계획지원시스템의 구축과 활용에 관한 연구)

  • Lee, Hee-Yeon
    • Journal of the Korean Geographical Society
    • /
    • v.42 no.1 s.118
    • /
    • pp.133-155
    • /
    • 2007
  • The sustainable urban development has emerged as a new paradigm of urban studies in recent years. A review of the literature of land use and transport policies in relation to sustainable development reveals a consensus that the main objectives of sustainable strategy should decrease the numbers and length of journeys, and change the land use pattern towards mixed use and high density. However, there is a lack of empirical research as to what types of policies might influence effectively the reduction in the energy consumption and emission of $CO_2$. in order to sustain urban development. This paper tries to construct the conceptual structure of the PSS(planning support system), which is designed to the simulation of the probable effects of policies and planning of different kinds in cities, and evaluate the sustainablilty level according to construct the structure of the PSS(planning support system), which is designed to the simulation of the probable effects of policies and planning of different kinds in cities, and evaluate the sustainablilty level according to the alternative scenarios. The PSS is composed of three components (input-modeling-output). The core of PSS is integrating land use-transport-environment modeling. The advantages of integrating land use-transport-environment modeling are well known, but there are very few such integrated modeling packages in practice. So this paper tries to apply TRANUS software, which is an integrated land use and transport model. The TRANUS system was calibrated to city of Yongin for the base year. The purpose of the application of TRANUS to Yongin is to examine the operability of TRANUS system in Korea. From the outputs and results of operating the system, TRANUS may be effectively used to evaluate the effects of alternative sustainable urban development policies, since sustainablilty indicators can be extracted from several aspects such as land use consumption, total trips, distance and cost, energy consumption, ratio of transport split.

Investigation and Risk Assessment of Asbestos-Containing Materials used in Buildings (건축물에 사용된 석면함유물질(ACMs)의 조사 및 위해성 평가)

  • Kim, Hong-Kwan;Chon, Young Woo;Roh, Young Man;Hong, Seung-Han;Kim, Chi-Nyon;Lee, Ik-Mo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.1
    • /
    • pp.35-42
    • /
    • 2018
  • Objectives: The objectives of this study are to research the usage characteristics of asbestos-containing building materials and to conduct exposure risk assessment by applying no. 2016-230 "Methods of Risk Assessment of Asbestos-Containing Buildings" from the Ministry of Environment. Methods: One hundred buildings located in the Seoul and Gyeonggi-Incheon area were chosen, with 29 in Seoul, 20 in Incheon, and 51 in Gyeonggi-do Province. The year of construction was divided between three buildings in the 1970s, 11 buildings in the 1980s, 42 buildings in the 1990s, and 44 buildings in the 2000s. The bulk samples were analyzed by using a polarizing microscope after a pre-process using a stereomicroscope in a hood with an HEPA filter. This study defined ACMs(asbestos-containing materials) as asbestos when the content percentage was over 1% in the analysis result. Methods and standards of risk assessment of asbestos-containing building materials were conducted by refering to no. 2016-230 "Method of Risk Assessment of Asbestos-Containing Buildings" from the Ministry of Environment. The risk of exposure to ACMs was rated by a score based on three categories(high, middle, low risk of asbestos exposure). Results: In this study, 30 of the 100 buildings and 36 of the 416 bulk samples(8.6%) were found to have had asbestos. Asbestos was detected at a high rate, in 18 out of 42, in buildings constructed in the 1990s and at the lowest rate(7 out of 44) for buildings constructed in the 2000s. As a result of the evaluation according to no. 2016-230 "Method of Risk Assessment of Asbestos-Containing Buildings" of the Ministry of Environment, the risk assessment level of two asbestos-containing building materials was found to be "Medium", and 28 buildings materials were found to be at the "Low" level. Conclusion: As asbestos is regulated by the government, it is required to conduct active management and implemention by introducing methods of risk assessment of asbestos exposure that are supported by data from various situations. In the case of buildings owned by individuals, building owners should be aware of the risk of exposure to asbestos.

Detection Ability of Occlusion Object in Deep Learning Algorithm depending on Image Qualities (영상품질별 학습기반 알고리즘 폐색영역 객체 검출 능력 분석)

  • LEE, Jeong-Min;HAM, Geon-Woo;BAE, Kyoung-Ho;PARK, Hong-Ki
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.3
    • /
    • pp.82-98
    • /
    • 2019
  • The importance of spatial information is rapidly rising. In particular, 3D spatial information construction and modeling for Real World Objects, such as smart cities and digital twins, has become an important core technology. The constructed 3D spatial information is used in various fields such as land management, landscape analysis, environment and welfare service. Three-dimensional modeling with image has the hig visibility and reality of objects by generating texturing. However, some texturing might have occlusion area inevitably generated due to physical deposits such as roadside trees, adjacent objects, vehicles, banners, etc. at the time of acquiring image Such occlusion area is a major cause of the deterioration of reality and accuracy of the constructed 3D modeling. Various studies have been conducted to solve the occlusion area. Recently the researches of deep learning algorithm have been conducted for detecting and resolving the occlusion area. For deep learning algorithm, sufficient training data is required, and the collected training data quality directly affects the performance and the result of the deep learning. Therefore, this study analyzed the ability of detecting the occlusion area of the image using various image quality to verify the performance and the result of deep learning according to the quality of the learning data. An image containing an object that causes occlusion is generated for each artificial and quantified image quality and applied to the implemented deep learning algorithm. The study found that the image quality for adjusting brightness was lower at 0.56 detection ratio for brighter images and that the image quality for pixel size and artificial noise control decreased rapidly from images adjusted from the main image to the middle level. In the F-measure performance evaluation method, the change in noise-controlled image resolution was the highest at 0.53 points. The ability to detect occlusion zones by image quality will be used as a valuable criterion for actual application of deep learning in the future. In the acquiring image, it is expected to contribute a lot to the practical application of deep learning by providing a certain level of image acquisition.

A Plan to Strengthen the Role of Citizens as Co-Creators of Smart City Services - Focused on the Development of Function Issue Card Technology - (스마트도시서비스 공동창의자로서의 시민 역할 강화 방안 - 기능카드 기법 개발을 중심으로 -)

  • JI, Sang-Tae;PARK, Jun-Ho;PARK, Joung-Woo;NAM, Kwang-Woo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.24 no.2
    • /
    • pp.1-11
    • /
    • 2021
  • Lately, the Korean Government has gradually expanded participation by local residents who are users of the area in the smart city project for the construction of region specialization smart city service (hereinafter called "Smart Service") and the enhancement in the citizen's awareness. However, due to the lack of information on smart service-related technology, there has been a limitation in getting the specific opinion of citizens in the process of designing the Smart Service. In this study, reports made by 4 four local governments which were selected for implementation of 2019 "Smart Town Challenge Projects" were reviewed to diagnose the actualization level of the smart service suggested by citizens through the living lab. The analysis results show that though the smart service plan was established by using diverse design thinking methodology through the living lab, there was a limitation in having citizens design the specific functions of the smart service. So, this study suggests the function issue card technique which can be used by modulating and freely combining four elements such as information collection, processing, supplying method and technique of the smart service and the service contents. This function issue card technique was directly applied to the living lab of the smart city project to verify its effectiveness. It was found that through this technique, citizens can combine the functions and contents of the smart service to materialize smart services at the level of detailed functions. The function issue card technique suggested in this study is expected to contribute to the actualization of opinions for the role of citizens as co-creators in solving local problems in the citizen participation type smart city plan in the future, thus helping the design of the regional specialization smart service.

Mitigation of Insufficient Capacity Problems of Central Bus Stops by Controlling Effective Green Time (유효녹색시간 조정을 활용한 중앙버스정류장 용량 부족 완화 방안 연구)

  • Koo, Kyo Min;Lee, Jae Duk;Ahn, Se Young;Chang, Iljoon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.21 no.1
    • /
    • pp.35-50
    • /
    • 2022
  • After the introduction of the central bus lane system, bus traffic was prioritized. This resulted in improved trust from bus users. However, the low capacity at the central bus stop reduces traffic speed and punctuality. In addition, physical constraints are inevitable because the construction of central bus lanes and bus stops considers the city's road geometry. Therefore, this study attempted to optimize the effective green time of the traffic signal system at the entrance and exit of the central bus stop to remedy its insufficient operational capacity. The Transit Capacity and Quality of Service Manual and Korea Highway Capacity Manual were used as the analysis methodologies. The number of stop areas for central bus stops to be built was determined by excluding variable physical factors, and field survey data collected from nine randomly selected central bus stops currently installed in Seoul were used. A scenario analysis was conducted on the central bus stops with insufficient capacity by adjusting the effective green time, and the capacity of the central bus stop was set as the dependent variable. According to the results, 26.7 percent of the central bus stops with insufficient capacity can solve the problem of insufficient capacity. Therefore, the results of this study can be verified by improving the operation level, and it can be effective even if the number of central bus stops calculated by engineering is not guaranteed during the planning stage of the central bus stop. As the number of central bus stops is expected to increase further as the number of central bus stops increases, it is necessary to improve the number of central bus stops. Therefore, it is hoped that the results presented in this study will be used as basic data for the improvement plan at the operational level before introducing the physical improvement plan.

Characteristics and Status of Roof Tile Buildings of Pungnaptoseong Fortress (풍납토성 기와건물지의 성격과 위상)

  • SO Jaeyun
    • Korean Journal of Heritage: History & Science
    • /
    • v.56 no.3
    • /
    • pp.46-59
    • /
    • 2023
  • Various Baekje ground-level building sites have been identified, in Pungnaptoseong Fortress, including Mirae Village's site E-1. However, building site E-1 is the only one with excavated roof tiles that are directly connected to the building site. As for building sites E-2, D-1, and D-2, which are comparable to site E-1, it is very possible that they had tiles on the roof based on their jeoksim (blocking facilities for roof slopes) and building structures. Also, although they are semi-underground pit structures, pit building sites A-30 and modern apartment site A-5, as well as the No.44 remains of Gyeongdang District, which is closer to a ground-level type, the buildings with tiles may have been constructed in the form of partial tile roofs rather than full-face tile roofs. Therefore, there may be several reasons behind the use of tiles on roofs in the early days, but the primary background of the building's authoritative function would have been considered first. Considering that China and Japan started using tiles on nationally important buildings such as palaces, temples, and ritual buildings, it may be presumed that Baekje began using tiles from the time it centralized power. It is believed that Baekje's early roof tile buildings evolved from rudimentary residential architecture to advanced public architecture, taking into consideration fire prevention and structural stability in large buildings. It is difficult to find similar cases in Korea with structural features such as the elevated foundations or underground stone foundations that can be found in Mirae Village building site E-1. Rather, similar architectural techniques can be found in China and Japan. In China, similar construction techniques were discovered in buildings of worship that were primarily built in the palace surroundings, such as Jangan Castle. Based on this, it appears that roof tile building sites, such as site E-1, that have been discovered have a strong correlation with the characteristics of buildings of worship, and ground type buildings, such as sites D-1 and D-2, are important facilities that are related to important public facilities such as state-run warehouses. This provides many implications regarding the early Baekje city structure.

Distribution, Preservation Characteristics of Land and River Natural Aggregates in Nonsan City, Korea (논산시 하천 및 육상 골재 자원의 부존 현황과 특성)

  • Hyun Ho Yoon;Sei Sun Hong;Min Han;Jin-Young Lee
    • Economic and Environmental Geology
    • /
    • v.57 no.2
    • /
    • pp.143-159
    • /
    • 2024
  • Natural aggregate is an essential resource for human activities, closely related to construction. The aggregate demand has been increasing annually, and due to the nature of the resource, it is difficult to procure from distant locations. This study identifies the distribution and characteristics of aggregate-bearing areas as part of a municipal-level aggregate resource survey conducted in Nonsan City, Korea, in 2023. Nonsan City is located approximately 35 km straight distance from the Geum River estuary and lies at the passageway of the main stream of the Geum River. The topography of Nonsan City features eastern mountainous areas and western plains, creating an east-high-west-low geomorphic setting, with 33 streams distributed across the city, including tributaries of the Geum River like Nonsan Stream, Noseong Stream, and Ganggyeong Stream. All streams originate from the highlands in the north and east, converge with Nonsan Stream, and then join the west bank of the main stream of the Geum River at the western boundary of Nonsan City. Drilling core results show shallow depths in the highlands to the north and east, deepening towards the west, reaching a maximum depth of 25 m near the main stream of the Geum River. The total reserve of land aggregates is calculated to be 246,789,000 m3, with a developable amount of 172,750,000 m3. The total reserve of river aggregates is 5,236,000 m3, with a developable amount of 3,765,000 m3. The distribution of aggregates varies according to the geomorphic, geologic, and development pattern of the river system. Reserves are scarce in mountainous areas but are abundant in regions with rivers and wide alluvial plains, although reserves appear at depths greater than 4m. The distribution of aggregate resources in Nonsan City is influenced by stream activities and sea level changes, with the tidal range of the Yellow Sea acting as an unfavorable condition for the preservation of aggregate resources.