• Title/Summary/Keyword: Construction facility

Search Result 1,626, Processing Time 0.028 seconds

Construction and Circuital Characteristics of Simple Synthetic Test Facility (간이 합성시험설비의 구성 및 회로특성)

  • Lee, J.H.;Park, K.Y.;Chang, K.C.;Shin, Y.J.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.168-170
    • /
    • 1995
  • This paper proposes the circuit of the simple synthetic testing facility using LC resonance circuit. The analyzed results of the circuit which can be useful for the design stage of the testing facility are also shown. EMTP has been used to analyze the circuit. Two cases of short-circuit test results obtained from the simple synthetic testing facility in KERI are shown with the waveforms of current and voltage. The results also indicate that the simple synthetic testing facility using LC resonance circuit can be easily designed and used very usefully for the research and development for the switchgears.

  • PDF

Development of infiltration facility by utilizing tree box for urban storm water runoff reduction (도시지역 우수유출 저감을 위한 식재박스형 침투시설의 개발)

  • Joo, Jin-Gul;Cho, Hye-Jin;Lee, Yu-Hwa;Kim, Lee-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5330-5336
    • /
    • 2011
  • It becomes more and more important to develop various infiltration facilities for healthy water cycle and reduction of urban storm water runoff. In this study, a infiltration facility by utilizing tree box was developed. The developed facility is capable of reducing storm water road runoff, improving urban water cycle, and performing other sustainable and environmental functions. Because the facility can be manufactured to a smaller size than an existing runoff reduction facility, it can be installed at various road types of not only existing urban areas, but new developed areas. If the facility is applied to four-lane roadways, it is expected to reduce 65% of rainfall runoff discharge. Urban flood control improvement can be accomplished by a wide application of the developed technique.

A Case Study on the Improvement of Real-Time Facility Safety Management Using Sensor (센서를 이용한 실시간 시설물 안전관리 개선에 대한 사례연구)

  • Choi, Suwon;Yoon, Yousang;Lim, Susang;Park, Yongbok;Suh, Sangwook
    • Korean Journal of Construction Engineering and Management
    • /
    • v.21 no.5
    • /
    • pp.38-45
    • /
    • 2020
  • Presently, safety management of facilities is conducted as a site-oriented safety inspection, but depending on the facilities, there are difficulties in access to the site, and the cost and time of inspection are inefficient due to excessive reliance on human resources. Therefore, the necessity of sensor-based safety management is being raised to ensure the safety of the facility at all times, and various studies on sensor safety management are being conducted, but the research on verification of practicality is still insufficient. Therefore, the improvement points were presented through analysis of domestic and international studies, and additional processes for setting sensor attachment location and threshold were derived by analyzing the H city sensor safety management process, and practicality of sensor safety management was verified through sensor data measurement values. It is expected that efficient, sensor-based facility safety management will be possible if clear criteria and ongoing practicality verification for the additional processes presented in this study should be carried out in the future.

Methane Engine Combustion Test Facility Construction and Preliminary Tests (메탄엔진 연소시험설비 구축 및 예비 시험들)

  • Kang, Cheolwoong;Hwang, Donghyun;Ahn, Jonghyeon;Lee, Junseo;Lee, Dain;Ahn, Kyubok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.3
    • /
    • pp.89-100
    • /
    • 2021
  • This paper deals with the construction of a combustion test facility and preliminary tests for hot-firing tests of a methane engine. First, the combustion test facility for a 1 kN-class thrust chamber using liquid oxygen/gas methane as propellants was designed and built. Before hot-firing tests, the cold-flow tests of each propellant line and the ignition tests of torch igniter/afterburner were performed to verify propellant supply stability of the combustion test facility, operation of the control and measurement system, and successful ignition. Finally, a preliminary hot-firing test was conducted to measure the combustion efficiency, heat flux, and combustion stability of a thrust chamber prototype. The constructed combustion test facility will be helpfully used for basic research and development of methane engine thrust chambers.

A Study for the Community Vitalizing Strategy Through the Revision of Housing Construction Standards for Community Facilities in Apartment Housing Complexes from the Perspective of Professionals (공동주택단지 내 주민공동시설의 기준개선을 통한 커뮤니티 활성화방안에 대한 전문가 의견조사)

  • Shin, Hwa-Kyong;Kim, Young-Joo;Lee, Soo-Jin;Jo, In-Sook
    • Journal of Families and Better Life
    • /
    • v.30 no.1
    • /
    • pp.29-40
    • /
    • 2012
  • The purpose of this study is to find out the problems of current housing construction standards related to community facilities and to suggest the vitalizing strategies that enhance the sense of community among the residents living in apartment housing complexes. For the purpose, three times small group workshops were executed during April 26~May 3, 2010 for 14 professionals in construction company, university, research institute, and housing management company. Based on the results of small group workshops, questionnaire survey for the 10 professionals was done during August 13~23, 2010 to find out the additional opinions about the revision of housing construction standards related to community facilities in apartment housing complexes. Respondents indicated that the current housing standards related to the types and the area of community facility are too strict to respond to the diverse characteristics and needs of residents. Professionals suggested the newly revised standards that sum up the whole area of community facilities instead of the existing standards that regulate the area of each community facility in an apartment housing complex. Also, they recommended the regional community center that include several facilities in one common community building.

A Study on the Derivation of the User-Oriented Agricultural Drought Assessment Criteria Using the AHP technique (AHP기법을 이용한 수요자 중심의 농업가뭄 영향 평가 기준 도출 연구)

  • Lee, Suk-Ju;Song, Jae-Do;Jang, Tae-Il;Sul, Dong-Moon;Son, Jae-Kwon
    • Journal of Korean Society of Rural Planning
    • /
    • v.24 no.4
    • /
    • pp.47-55
    • /
    • 2018
  • Currently in the drought evaluation, which is a supplier-oriented standard that applies storage rates of reservoirs, evaluation for users that use agricultural water is not done. Therefore, this study established drought evaluation items for drought evaluation based on farmers' judgement, conducted a survey on farmers and experts, compared and analyzed weighted value between two groups, and then classified the evaluation standards per each evaluation item. The agricultural drought evaluation items are 5 major items of water supply lapse rate, agricultural weather, agricultural irrigation facility, crop and soil, and 12 subsections for regional characteristics and opinions of consumers that use water to be reflected. The result of analyzing weighted value of farmers and experts' major items shows that farmers is agricultural irrigation facility(0.219), water supply lapse rate(0.211), agricultural weather(0.204), crop(0.183) and soil(0.183). Experts is agricultural weather(0.297), agricultural irrigation facility(0.202), water supply lapse rate(0.189), crop(0.162) and soil(0.150), which displays difference between the two groups. The agricultural drought criteria standards are established based on precedent studies and cases, and grades of evaluation items are 1st grade(extreme stage), 2nd grade(warning stage), 3rd grade(alert stage) and 4th grade(attention stage). The above analysis per each consumer-oriented agricultural drought evaluation item and the analysis on the standards of evaluation grades are expected to be used as a basic resource for establishing agriculture drought policy and selecting drought area in the future.

Chemical/Biological/Radiological Protective Facility Entering Time Estimation Simulation with Procedure Analysis (화생방 방호시설의 행동 절차 분석을 통한 진입 소요시간 예측 시뮬레이션)

  • Park, Sun Ho;Lee, Hyun-Soo;Park, Moonseo;Kim, Sooyoung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.5
    • /
    • pp.40-48
    • /
    • 2014
  • As CBR(Chemical, Biological, and Radiological) attack increases, the importance of CBR protective facilities is being emphasized. When CBR warfare emerges, a task force team, who exist outside of CBR protective facility, should enter the CBR protective facility through neutralizing process in CCA(Contamination Control Area) and TFA(Toxic Free Area). If a bottleneck occurs in the process or zones, the task force team cannot enter the CBR protective facility efficiently and may cause inefficiency in its operation performance or result in casualties. The current design criteria of the CBR protective facility is only limited to ventilation system and it does not consider how much time it takes to enter the facility. Therefore, this research aims to propose the entering time estimation model with discrete event simulation. To make the simulation model, the procedure performed through CCA and TFA is defined and segmented. The actual time of the procedure are measured and adapted for the simulation model. After running the simulation model, variables effecting the entering time are selected for alternatives with adjustments. This entering time estimation model for CBR protective facility is expected to help take time into consideration during the designing phase of CBR protective facility and help CBR protective facility managers to plan facility operation in a more realistic approach.

A Quantity Prediction Model for Reinforced Concrete and Bricks in Education Facilities Using Regression Analysis

  • Lee, Jong-Kyun;Kim, Boo-Young;Kim, Jang-Young;Kim, Tae-Hui;Son, Kiyoung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.5
    • /
    • pp.506-512
    • /
    • 2013
  • Since the amendment of the law on the private sector investment in social infrastructure in January of 2005, the government has been actively promoting Build-Transfer-Lease (BTL) projects. Notably, most new educational facilities have been built as BTL projects. For these facilities, the unit cost per unit area has been applied to predict construction costs. However, since construction costs are mostly managed after the detailed design phase, the costs can be estimated incorrectly. For this reason, cost management is needed in the planning phase, with a sound approximate estimate to prevent the wasteful use of funds. To address this shortcoming, this study aims to develop a quantity prediction model for education facilities using regression analysis in the planning phase. The developed model is focused on the required quantities of reinforced concrete and bricks. In order to achieve the objective, the data of 44 educational facility projects collected from Gyeonggi-do was used in the regression model. This study can be utilized by major stakeholders to accurately predict construction costs by estimating the appropriate quantities of reinforced concrete and bricks in the planning design phase.

Airport Power Information System Design in the Inchon Inta'l Airport (인천국제공항 공항전력정보시스템 설계)

  • Oh, Y.D.;Min, S.J.;Lim, J.G.;Moon, J.H.;Lee, T.S.;Yun, T.H.;Kim, M.H.;Moon, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1121-1124
    • /
    • 1998
  • Inchon International Airport(IIA) is constructed for Northeast Asia Gate as is important for IIA to become a 21 century's leader in the world, as is planned for open at december 2000 as a important economic link for unified korea. Airport Power Information System(APIS) is designed through investigation of advanced domestic and international example. In addition to power facility operation it is designed for using an information infrastructure of whole airport. APIS is newly designed for uninterupted power supply, effective power management, information infrastructure's construction. making a profit by positively introduction of new technology for collection and conservation of power related data, correlation with airport infra systems, data interrelative arrangement about related systems like outdoor lighting system and automatic measuring record, CCTV systems for remote power facility monitoring, and promotion of management ability in the emergency status.

  • PDF

The Study On A Marina's Construction Location Analysis Using Integer Optimization Programming (정수최적계획법을 이용한 마리나 건설 대상지 분석에 관한 연구)

  • Pak, Seong-Hyeon;Joo, Ki-See
    • Journal of Navigation and Port Research
    • /
    • v.34 no.1
    • /
    • pp.59-64
    • /
    • 2010
  • This study is to determine an optimal marina's construction location candidate among many alternative candidates in order to obtain the maximized efficiency under the natural conditions. To deal with marina's construction location, the optimal construction location is selected using 10 important factor analysis for 10 candidates in Yeosu city. In this paper, the new model to assign the most reasonable alternative is introduced using 0-1 integer programming. This proposed model has not been applied in the optimal marina's facility candidate selection problem yet. This paper will contribute to determine the most reasonable alternative. Also, this proposal model can be applied to other marina's facility candidate selection problem in other regions.