• 제목/요약/키워드: Construction behavior resistance.

검색결과 318건 처리시간 0.025초

지하주차장의 내화성능 평가를 위한 차량연소실험 (The combustion test of assuming in parking space for fire resistance)

  • 강승구;김동준;이재영;原田和典;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.48-50
    • /
    • 2013
  • In this study, Car fire for test using ISO 9705 10MW Large Scale Calorimeter. Especially, study on the underground parking for the fire resistance performance. The underground parking lot of the fire resistance regulations in according to with the standard heating curve in Korea. Because of this burning car through experiments to the propose a new heating curve.

  • PDF

압전센서를 이용한 콘크리트의 응결시간 추정 (Estimation of setting times of concrete using piezoelectric sensor)

  • 이준철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.99-100
    • /
    • 2021
  • In this study, the setting times of concrete was evaluated using the electro-mechanical (EMI) behavior of piezoelectric sensor embedded in the concrete. Penetration resistance test was also performed to compare with EMI sensing technique. As a result, the setting times of concrete can be measured more effectively than penetration resistance test through the EMI sensing technique using the piezoelectric sensor.

  • PDF

3차원 유한요소법을 이용한 강관합성 말뚝재료의 수평저항력 고찰 (Study on lateral resistance of steel-concrete composite drilled shafts by using 3D FEM)

  • 이주형;신휴성;최상호;박재현;정문경;곽기석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.683-690
    • /
    • 2008
  • Steel-concrete composite columns are popular for superstructures of bridges, and the outside steel attached to the shaft increases the shaft resistance due to confining concrete. In this study, lateral resistance of steel-concrete composite drilled shafts was evaluated quantitatively based on numerical analysis when steel casings are used as structural elements like composite columns. Ultimate lateral resistance of composite drilled shafts with various diameters was numerically calculated through 3D finite element analysis. For that, elasto-plastic model with perfectly plasticity is involved to capture the ultimate load. A commercial FEM program, MIDAS-GTS, is used in this study. Real field conditions of the West Coast, Korea were considered to set up the ground conditions and pile lengths required for this parametric studies. Detailed characteristics of the stress and displacement distributions are evaluated for better understanding the mechanisms of the composite shaft behavior.

  • PDF

고온에 노출된 PCM 충진형 바닥 시스템의 거동 특성 (Behavior Characteristics of PCM Infilled Floor System at Elevated Temperature)

  • 박민재;민정기;윤성원;주영규
    • 한국공간구조학회논문집
    • /
    • 제17권2호
    • /
    • pp.33-41
    • /
    • 2017
  • Composite Floor system infilled with PCM(Phase Change Material) between upper and lower steel plates was developed to apply the steel frame. When steel frames were applied this system, it can absolutely reduce the duration of construction due to dry construction method. However to apply this system as a structural floor member without fire resistance covering, it must have 2 hours fire resistance performance. Because PCM consisted of three quarters of section with thermal insulation performance, fire resistance performance of this floor system was expected to easily have 2 hours fire resistance performance. This paper was to investigate behavior characteristics of PCM infilled floor system at elevated temperature using FEM analysis to develop the fire resistance performance of it.

고속 비상체 충돌에 의한 콘크리트의 국부파괴에 미치는 혼입 섬유의 영향 (Influence of Reinforced Fiber on Local Failure of the Concrete subjected to Impact of High-Velocity Projectile)

  • 김홍섭;김규용;최경철;김정현;이영욱;한상휴
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.139-140
    • /
    • 2014
  • The purpose of this study in to evaluate relationship between mechanical properties of materials and fiber type by reinforced fiber with high-velocity impact fracture behavior of fiber reinforced concrete. As a result, for fracture behavior by high-velocity impact, it is considered that impact fracture behavior is not affected by static mechanical properties directly but affected by fiber type and density of the number of fiber. It is necessary to consider type, shape, mechanical properties and the number of fiber with flexural and tensile performance for the evaluation on impact resistance performance of fiber reinforced concrete.

  • PDF

성능기반 구조내화설계를 위한 단방향 연성해석 사용자가이드 조사에 관한 연구 (A Study on the Investigation of Users Guide of One-Way Coupled Analysis for Performance-Based Structural Fire Resistance Design)

  • 권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.96-97
    • /
    • 2021
  • In the Building Act, performance-based fire safety design is being promoted for institutionalization. The behavior of the structure against fire conditions can be predicted by using the advanced numerical analysis method based on the FEM (Finite Element Method) to predict the entire structural behavior including the behavior of the structure, but there is a limit to expressing the fire properties of the space and predicting the fire properties It is difficult to determine the variables to be transmitted to the FEM (Finite Element Method) model from the fire simulation results using FDS (Fire Dynamics Simulator). Accordingly, the purpose of this study is to introduce the code user's manual for FDS and FEM unidirectional coupling analysis.

  • PDF

지하 콘크리트 구조물의 거동에 대한 방수층의 대응성 평가에 관한 실험적 연구 (Performance Test Method on the Influence Waterproofing as Behavior of Concrete Structure)

  • 노종수;권시원;곽규성;권기주;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2004년도 학술대회지
    • /
    • pp.77-81
    • /
    • 2004
  • The massive structures are not free to move with vibration, differential settlement, thermal stresses because, construction and expansion joint, crack etc., can be large enough to cause leakage as deformation of waterproofing. It has been depended on the test method of tensile/tear strength which is waterproofing performance as behavior of concrete structure crack. However, not to practically confirm the creep applied to concrete surface, even waterproofing membrane have more performance than definite strength and elasticity. Therefore, in this study will focus on the test method to consider a resistance performance about loose adhesion and deformation of waterproofing and behavior of concrete structure as construction/expansion joint, crack. Performance test method on the influence as behavior of concrete structure crack is to choose waterproofing materials and construction method which possible to confront with behavior of 50mm crack in the atmosphere and low temperature. Examine the deformation of waterproofing membrane and loose adhesion which can occur to structure in general job site, suggest standard testing method to analyze correlation waterproofing membrane and structure with 5-types of materials used in this study, such as Adhesion membrane and sheet complex, sheet and urethane complex, self-adhesive sheet, spray poly-urea, spray membrane of rubberized Asphalt.

  • PDF

경계조건에 따른 일반강재 적용 보부재의 내화성능 연구 (Study on the Fire Resistance of Structural Beams Made of Ordinary Structural Steel(SS 400) According to Boundary Conditions)

  • 권인규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.167-168
    • /
    • 2014
  • Building destruction can be occurred by decreasing of structural stability and deformation according to fire. Especially, a structural behavior of beam can be shown a slightly difference by beam types. In this paper, an evaluation of the structural stability of beam made of ordinary structural steel designed by fixed and simple boundary condition was done by an analytic method using mechanical properties of SS 400 and an heat transfer theory.

  • PDF

하이브리드 유기섬유 보강 콘크리트의 제조 및 휨성능 평가 (A Processing and Flexural Performance Evaluation of Hybrid Organic Fiber Reinforced Concrete)

  • Jeon, Chanki;Jeon, Joongkyu;Shim, Jaeyeong
    • 한국재난정보학회 논문집
    • /
    • 제13권2호
    • /
    • pp.213-220
    • /
    • 2017
  • 일반적으로 유기섬유는 섬유 자체의 인장강도 및 탄성계수는 작지만, 내화성 및 내부식성이 우수하고, 콘크리트의 균열 제어 및 내충격 성능 향상에 효과적인 섬유이다. 따라서, 유기섬유는 콘크리트용 보강 섬유로서의 적용성이 매우 높은 재료이다. 본 연구에서는 폴리아미드(PA)섬유와 고강력의 폴리에스터(PET)섬유를 혼입한 하이브리드 유기섬유를 개발하였으며, 하이브리드 유기섬유를 혼입한 섬유보강 콘크리트의 휨성능 시험을 통해 하이브리드 유기섬유 보강 콘크리트의 에너지 흡수능력을 평가하고자 한다.

Behavior and resistance of truss-type shear connector for composite steel-concrete beams

  • Lima, Jerfson M.;Bezerra, Luciano M.;Bonilla, Jorge;Silva, Ramon S.Y.R.C.;Barbosa, Wallison C.S.
    • Steel and Composite Structures
    • /
    • 제36권5호
    • /
    • pp.569-586
    • /
    • 2020
  • The behavior of composite steel-concrete beams depends on the transmission of forces between two parts: the concrete slab and the steel I-beam. The shear connector is responsible for the interaction between these two parts. Recently, an alternative shear connector, called Truss Type connector, has been developed; it aligns efficient structural behavior, fast construction and implementation, and low cost when compared to conventional connectors applied in composite structures. However, there is still a lack of full understanding of the mechanical behavior of the Truss Type connector, due to its novelty. Thus, this study aims to analyze the influence of variation of geometric and physical parameters on the shear resistance of the Truss Type connector. In order to investigate those parameters, a non-linear finite element model, able to simulate push-out tests of Truss Type connectors, was specifically developed and validated with experimental results. A thorough parametric study, varying the height, the angle between rods, the diameter, and the concrete strength, was conducted to evaluate the shear resistance of the Truss Type connector. In addition, an equation to predict the resistance of the original Truss Type shear connector was proposed.