• 제목/요약/키워드: Constant Pressure System

검색결과 570건 처리시간 0.027초

Unsteady Flow with Cavitation in Viscoelastic Pipes

  • Soares, Alexandre K.;Covas, Didia I.C.;Ramos, Helena M.;Reis, Luisa Fernanda R.
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권4호
    • /
    • pp.269-277
    • /
    • 2009
  • The current paper focuses on the analysis of transient cavitating flow in pressurised polyethylene pipes, which are characterized by viscoelastic rheological behaviour. A hydraulic transient solver that describes fluid transients in plastic pipes has been developed. This solver incorporates the description of dynamic effects related to the energy dissipation (unsteady friction), the rheological mechanical behaviour of the viscoelastic pipe and the cavitating pipe flow. The Discrete Vapour Cavity Model (DVCM) and the Discrete Gas Cavity Model (DGCM) have been used to describe transient cavitating flow. Such models assume that discrete air cavities are formed in fixed sections of the pipeline and consider a constant wave speed in pipe reaches between these cavities. The cavity dimension (and pressure) is allowed to grow and collapse according to the mass conservation principle. An extensive experimental programme has been carried out in an experimental set-up composed of high-density polyethylene (HDPE) pipes, assembled at Instituto Superior T$\acute{e}$cnico of Lisbon, Portugal. The experimental facility is composed of a single pipeline with a total length of 203 m and inner diameter of 44 mm. The creep function of HDPE pipes was determined by using an inverse model based on transient pressure data collected during experimental runs without cavitating flow. Transient tests were carried out by the fast closure of the ball valves located at downstream end of the pipeline for the non-cavitating flow and at upstream for the cavitating flow. Once the rheological behaviour of HDPE pipes were known, computational simulations have been run in order to describe the hydraulic behaviour of the system for the cavitating pipe flow. The calibrated transient solver is capable of accurately describing the attenuation, dispersion and shape of observed transient pressures. The effects related to the viscoelasticity of HDPE pipes and to the occurrence of vapour pressures during the transient event are discussed.

Pd/C촉매하 파라니트로아닐린 수소첨가에 의한 고순도 파라페닐렌디아민의 합성공정 (Synthesis of High Purity p-Phenylenediamine from p-Nitroaniline by Catalytic Hydrogenation)

  • 조철군;정광보
    • 공업화학
    • /
    • 제10권8호
    • /
    • pp.1210-1215
    • /
    • 1999
  • Pd/C촉매가 부유되어 있는 3상 슬러리 반응기에서 원료 p-nitroaniline(PNA)를 수소 첨가시켜 고순도의 p-phenylenediamine(PPD)를 합성하는 최적 반응조건을 구하였다. 수소첨가 반응시 활성점에서 수소부족을 줄이고 불순물의 생성을 감소시킬 수 있도록, 기체-액체, 액체-촉매사이의 물질전달 저항을 최소화하고 표면반응속도가 율속할 수 있게 반응조건을 설정하였다. 이 반응조건은 온도 $60^{\circ}C$, 압력 60~70 psig, 촉매농도 1~2 g-cat/L일 때가 최적이었으며, 반응속도는 PNA 농도에 0차, 수소 반응압력에 1차를 각각 보여주었으며, 총괄반응속도식은 $R_A=6.44{\times}10^6{\cdot}H{\cdot}P{\cdot}m{\cdot}$exp(-4659/T)로 나타났다.

  • PDF

수소저항합금을 이용한 150ℓ급 수소저장용기의 제작과 특성에 관한 연구 (Fabrication and Characteristics of 150ℓ Class Hydrogen Tank Using Hydrogen Storage Alloy)

  • 강길구;강세선;권호영;이임렬
    • 한국수소및신에너지학회논문집
    • /
    • 제13권2호
    • /
    • pp.110-118
    • /
    • 2002
  • The hydrogen storage vessel having a good heat conductivity along with a simple structure and a low cost for these alloys was designed and manufactured, and then its characteristic properties were studied in this study. The various parts in hydrogen storage vessel consisted of copper pipes and stainless steel of 250 mesh reached the setting temperature after 4~5 minutes, which indicated that storage vessel had a good heat conductivity that was required in application. And also the storage vessel had a good property of hydrogen transport considering that the reaction time between hydrogen and rare-earth metal alloys in storage vessel was found to be within 10 min at $18^{\circ}C$ under 10 atmospheric pressure. It showed that the average capacity of discharged hydrogen volume was found to be $120{\ell}$ for $MmNi_{4.5}Mn_{0.5}$ under discharging conditions of $40^{\circ}C{\sim}80^{\circ}C$ at a constant flow rate of $5{\ell}$/min. It was found that the optimum discharging temperature for obtaining an appropriate pressure of 3atm was determined to be $60^{\circ}C$ for $MmNi_{4.5}Mn_{0.5}$ hydrogen storage alloy.

Low-temperature crystallization of high-dielectric (Ba,Sr)$TiO_3$ thin films for embedded capacitors

  • Cho, Kwang-Hwan;Kang, Min-Gyu;Kang, Chong-Yun;Yoon, Seok-Jin
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술회의 초록집
    • /
    • pp.21-21
    • /
    • 2010
  • (Ba,Sr)$TiO_3$ (BST) thin film with a perovskite structure has potential for the practical application in various functional devices such as nonvolatile-memory components, capacitor, gate insulator of thin-film transistors, and electro-optic devices for display. Normally, the BST thin films derived from sol-gel and sputtering are amorphous or partially crystalline when processed below $600^{\circ}C$. For the purpose of integrating BST thin film directly into a Si-based read-out integrated circuit (ROIC), it is necessary to process the BST film below $400^{\circ}C$. The microstructural and electrical properties of low-temperature crystallized BST film were studied. The BST thin films have been fabricated at $350^{\circ}C$ by UV-assisted rapidly thermal annealing (RTA). The BST films are in a single perovskite phase and have well-defined electrical properties such as high dielectric constant, low dielectric loss, low leakage current density, and high breakdown voltage. Photoexcitation of the organics contained in the sol-gel-derived films by high-intensity UV irradiation facilitates elimination of the organics and formation of the single-crystalline phase films at low temperatures. The amorphous BST thin film was transformed to a highly (h00)-oriented perovskite structure by high oxygen pressure processing (HOPP) at as low as $350^{\circ}C$. The dielectric properties of BST film were comparable to (or even better than) those of the conventionally processed BST films prepared by sputtering or post-annealing at temperature above $600^{\circ}C$. When external pressure was applied to the well-known contractive BST system during annealing, the nucleation energy barrier was reduced; correspondingly, the crystallization temperature decreased. The UV-assisted RTA and HOPP, as compatible with existing MOS technology, let the BST films be integrated into radio-frequency circuit and mixed-signal integrated circuit below the critical temperature of $400^{\circ}C$.

  • PDF

양산-물금 충적점토의 토질특성에 관한 연구 (A Study on the Characteristics of Alluvial Clay in Yangsan-Mulgum)

  • 이달원
    • 한국농공학회지
    • /
    • 제39권1호
    • /
    • pp.102-111
    • /
    • 1997
  • Experiments both in laboratory and field were performed to compare and analyze the characteristics of alluvial clay. The alluvial clay was sampled in test site in which large-scaled tests for the part of the site are under process to suggest the rational method for alluvial clay and the criterion for ground settlement monitoring system. The followings were observed through the experiments : 1. Natural water content, plastic limit, and liquid limit of alluvial clay composed of highly fine grains were 40~80%, 10~20%, and 30~55%, respectively. The values of these properties were relatively small at the ground surface, while the values showed maximum at G.L.- l0m and gradually decreased below the level. 2. Shear strength of alluvial clay was proportionally increased to the depth. Unconfined and triaxial compressive strengths were 0.2~0.6kgf/$cm^2$ and 0.1~0.3kgf/$cm^2$, respectively. 3. Compression index and secondary compression index showed maximum values at G.L.-l0m and gradually decreased below the level. The value of consolidation coefficient was relatively large at the ground surface, constant with decreasing the depth, and incresed when G.L. was below -20m. 4. Piezocone test appeared that alluvial clay with N value of 2~4 was uniformly distributed with 20~ 30m thickness from the ground surface, sand seam was nonuniformly distributed, and penetration pore pressure was 0.8 ~ 1 times of the hydrostatic pressure. Undrained shear strength and consolidation coefficient were 0.04 ~ 0.76kgf / $cm^2$ and $2.88{\times} 10{^-4}~1.3{\times} 10{^-2} cm^2/s$ respectively.

  • PDF

21톤급 전기 굴삭기용 파일럿 작동식 유량제어 밸브의 해석모델 개발 및 검증 (Development and Verification of Analytical Model of a Pilot Operated Flow Control Valve for 21-ton Electric Excavator)

  • 김동명;남용윤;서자호;장주섭
    • 드라이브 ㆍ 컨트롤
    • /
    • 제12권3호
    • /
    • pp.52-59
    • /
    • 2015
  • An electro hydraulic poppet valve (EHPV) and a variable orifice poppet are assembled in a single block, which is referred to as a RHINO but is also generally called a pilot-operated flow control valve. In this study, we analyzed the structure and the operating principle for a RHINO applied in a 21-ton electric excavator system. The RHINO was experimentally tested to measure the dynamic responses and the pressure energy loss. In this test, we investigated the variation in the conductance coefficient according to the increase in the supply pressure under a constant current and a variation in the flow rate according to the increase in the current. Then, the geometrical shapes and the spring stiffness of the RHINO were considered to develop an analysis model. The characteristics (current-force and hysteresis) for the solenoid based on the experimental data were reflected in the analysis model that was developed, and the reliability of the analysis model was also verified by comparing the experimental and analytical results. The developed model is thus considered to be reliable for use in a wide range of applications, including optimum design, sensitivity analysis, parameter tuning, etc.

능동형 근육펌프 구조의 수액 주입 펌프 개발에 관한 연구 (A Study on the Development of a Infusion Pump based on an Active Muscle Pump)

  • 이정환;이상엽;이정은;안인석
    • 한국산업융합학회 논문집
    • /
    • 제25권3호
    • /
    • pp.443-449
    • /
    • 2022
  • In this study, in order to improve the disadvantages of the environmental error of the infusion set that performs infusion therapy in the existing clinical practice and to maximize the user's convenience by miniaturizing the existing infusion pump system, the structure of the muscle pump of the human vein was imitated. As a double check valve method, a method for preventing the backflow of fluid and discharging a constant fluid in one direction by external pressure was proposed. The proposed bio-mimic muscle pump uses a check valve that controls the flow of fluid in one direction and a silicone tube with elasticity, and a chamber is constructed. A peristaltic pump for applying intermittent pressure to the tube chamber was constructed using a multi-cam structure roller. In order to verify the performance of the proposed pump, optimization was performed while changing the number of multi-cam rollers and adjusting the speed of the roller driving motor, and the reproducibility of the instantaneous discharge amount and the continuous discharge amount of the pump was compared and tested. The performance of the muscle pump proposed in this study was verified through experiments that it can inject up to 1L of fluid within 12 hours, and that it is possible to inject the fluid with an accuracy of ±0.1ml. Real-time monitoring of the fluid injection volume through the bio-mimic muscle pump proposed in this study not only increases the convenience of the administrator, but also provides a precise fluid administration environment to more patients at a low cost, and additionally applies bubble detection and occlusion detection technology If so, it is believed that a safer medical environment can be provided to patients.

초임계 ASES 공정으로 제조된 Vitamin-C 포접복합체의 안정성 평가 (Stability Evaluation of Vitamin-C Inclusion Complexes Prepared using Supercritical ASES Process)

  • 양준모;김석윤;한지현;정인일;유종훈;임교빈
    • KSBB Journal
    • /
    • 제21권2호
    • /
    • pp.157-163
    • /
    • 2006
  • 본 연구에서는 초임계 ASES 공정을 이용하여 인체내 및 피부에 여러 가지로 유익한 대표적 생리활성물질인 Vitamin-C의 불안정성을 극복하기 위하여 HP-${\beta}$-CD와의 포접복합체를 제조하여 수용액상에서의 안정성을 분석하였다. X-선 회절을 이용한 Vitamin-C와 HP-${\beta}$-CD의 결정성 분석으로 초임계 ASES 공정을 통하여 포접복합체가 용이하게 형성될 수 있음을 확인하였다. HP-${\beta}$-CD가 Vitamin-C의 안정성을 향상시키는 방법으로 이용될 수 있음을 확인하였으며, $25{\pm}0.1^{\circ}C$의 온도를 유지한 pH 7.0의 50 mM 인산완충용액 상에서 순수한 Vitamin-C, 물리적인 혼합물 및 용매증발법과 초임계 ASES 공정을 이용하여 제조된 포접복합체의 Vitamin-C 겉보기 1차 분해 속도 상수는 각각 $1.45{\times}10^{-2}h^{-1},\;1.41{\times}10^{-2}h^{-1},\;1.34{\times}10^{-2}h^{-1},\;0.20{\times}10^{-2}h^{-1}$로 초임계 ASES 공정으로 제조된 포접복합체의 경우 Vitamin-C의 안정성이 매우 크게 향상되는 것을 확인하였다.

마이크로프로쎄서를 이용한 과채류 자동 저장 제어장치의 제작과 온도 자동계측 관리 시스템 (Development of Microprocessor-based Automatic Storage Controller and Temperature Auto-measurement System for Horticultural Crops)

  • 박제균;전재근;이승구;김공환
    • 한국식품과학회지
    • /
    • 제20권6호
    • /
    • pp.845-849
    • /
    • 1988
  • 저장실, 저장상자, 공기분배장치 등을 포함한 실험실 규모의 저장실을 설계, 제작하였다. 과실류를 수용할 수 있는 저장상자(1.7 l)는 투명아크릴을 재질로 일정 공기가 계속해서 순환되도록 하고 저장실은 $0{\sim}30^{\circ}C$ 범위내에서 ${\pm}0.5^{\circ}C$의 정확도로 온도제어가 가능하였다. 저장상자로 유입되는 공기는 공기분배 장치를 통하여 예냉과 공기압의 균일화가 이루어지도록 하였고 Solenoid valve를 사용한 저장상자 선택장치를 제작하였다. 이와 같은 저장시설의 환경제어와 계측을 전담할 수 있는 마이크로프로셰서 시스템을 8 bit 마이크로프로쎄서와 기억장치, 그리고 입출력장치 등의 IC chip을 이용하여 설계 제작하였다. 동 시스템을 활용하기 위하여 저장환경의 제어를 위한 소프트웨어를 개발하고 운영프로그램을 ROM화 할 수 있었다. 제작된 저장 자동제어장치 시스템을 이용 밀감류 저장에 적용하여 저장시설의 운영 및 온도의 자료수집을 성공적으로 수행할 수 있었다.

  • PDF

PHASE-B PRE-SIMULATION USING BORON AND GADOLINIUM AS POISON IN THE MODERATOR SYSTEM FOR WOLSONG-1

  • Kim, Sung-Min;Kim, Hyeong-Taek;Donnelly, Jim;Marleau, Guy
    • Nuclear Engineering and Technology
    • /
    • 제44권5호
    • /
    • pp.551-560
    • /
    • 2012
  • The Wolsong-1 (W-1) Phase-B pre-simulations were carried out in preparation for tests to be conducted for the restart of the reactor after a major refurbishment project that included replacement of the pressure tube. These pre-simulations for Wolsong-1 Phase-B differ from those in the past that were performed for the Wolsong-1,2,3,4 tests in that these tests use the WIMS/DRAGON/RFSP-IST code suite for verification of the tests and gadolinium instead of the traditional PPV/MULTICELL/RFSP code system and boron as poison in the moderator system. The use of gadolinium is deemed not to have domestically accumulated experience gained from the previous Phase-B tests. Thus, it is appropriate to conduct a study in order to gain a correct understanding and interpretation of potential differences in test results stemming from using gadolinium rather than boron. Although the calibration of the reactivity device will not be noticeably different using boron and gadolinium at a constant moderator temperature, the temperature dependency of the neutronic behavior due to the presence of gadolinium in the moderator system might be pronounced. The results of the pre-simulations using gadolinium revealed that the moderator temperature reactivity coefficients indeed showed significant differences in comparison with those with boron. In order to secure the validity of the analysis results, the newly acquired WIMS/DRAGON/RFSP-IST code suite was verified against the W-2,3,4 Phase-B test results. The results of the new code suite verifications revealed some overall improvements in accuracy; justification of the use of the code can be claimed for the validation of the W-1 Phase-B test results.