• 제목/요약/키워드: Consistency test

검색결과 948건 처리시간 0.025초

콘크리트의 Consistency 변화가 소성수축에 미치는 영향 (Influence on the Plastic Shrinkage of Concrete for a Varieties of Consistency)

  • 오무영
    • 한국농공학회지
    • /
    • 제20권1호
    • /
    • pp.4626-4630
    • /
    • 1978
  • The objective of this study is to investigate how the varieties of consistency of fresh concrete influence on the plastic shrinkage in dry condition. The test was conducted under the controlled chamber in which the temperature was kept at 25 ${\pm}$2$^{\circ}C$, the humidity 35 ${\pm}$3%, and the wind velocity 4.0 ${\pm}$0.5m/sec. The results obtained from the test are as follow. 1) The rate of evaporation was highest at 2-3 hour after casting, and decreased gradually. 2) The plastic shrinkage was increased as to the slump values. The shrinkage rate was very highest at 2-4 hour and hardly showed any changes after 6 hour. 3) The recommendation for good cloncrete is that slump value should be as low as possible in construction.

  • PDF

콘크리트 표층부 품질이 SL재의 하자에 미치는 영향 - SL재의 하자 발생에 영향을 미치는 콘크리트 표층부의 품질 평가방법(II) - (The Relationship Between the Quality of Surface Layer of Concrete Floor and the Defect of Self-Leveling Material - Evaluation Method about Surface Layer Quality of Concrete Floor Groundwork Corresponding to Defect in Self-leveling Material (Part II) -)

  • 김두호;최수경
    • 한국건축시공학회지
    • /
    • 제7권4호
    • /
    • pp.125-132
    • /
    • 2007
  • The use of Self-Leveling material is increasing recently. This paper assesses the quality of surface layer of concrete floor when Self-Leveling material is defective. The paper shows how to predict the defect of SL material before construction begins. The relationship between the quality of surface layer of concrete floor and the defect of SL material was determined and the quality of surface layer of concrete floor was then estimated. The relations between the quality of surface layer and the defect of SL material were determine considering surface strength, moisture, and consistency of surface layer. Absorbing amount was used as the indicator of consistency and the absorbing amount of test material was measured. Then the relations between the test material and surface strength were determined. Generally concrete floor with greater consistency has greater surface strength, however in this study, we hound that high impact concrete floor could have lower surface strength as the consistency gets bigger. The relations between the level of defect occurred in SL material and the quality of surface layer were examined and we clarified that the surface layer with lower consistency gets higher possibility to occur exfoliation in early stage, one or two weeks after constructing SL material. When the consistency is sufficient, the occurring situation of defect depends upon the moisture of surface layer. Little amount of moisture gets higher possibility not to occur the defect. As the amount increases, fissure generates and early exfoliation may occur. In addition, the level of fissure is highly related with the surface strength.

중학생에 있어서 음양 기질의 안정성 (The Stability of Yin-Yang Temperament in Middle School Students)

  • 이수진;채한
    • 사상체질의학회지
    • /
    • 제31권1호
    • /
    • pp.94-101
    • /
    • 2019
  • Objectives The Yin-Yang construct was shown to have stable internal reliability or consistency using Sasang Personality Questionnaire (SPQ) throughout the various ages, however the study of stability over specific period of time was only conducted using adults. The purpose of the study was to examine the stability across the time using middle school students whose physical and psychological characteristics were most rapidly changing. Methods The 122 middle school students (65 boys and 57 girls) completed the SPQ at 1st year and 2nd year with one-year time difference. Cronbach's ${\alpha}$ and Pearson's correlation analysis were employed in order to show the internal consistency and stability over one-year interval after considering sex difference. Results The internal consistency of SPQ-T, SPQ-B, SPQ-C, SPQ-E using Cronbach's ${\alpha}$ were .61, .72, .28, .28 in 2016 and .62, .72, .26, .46 in 2017. The one-year test-retest reliability of SPQ-T, SPQ-B, SPQ-C, SPQ-E using Pearson's correlation analysis were .56, .61, .31, .23 in boys and .58, .63, .64, .29 in girls. Conclusion The current study showed the stability of Yin-Yang temperament across the one-year time suggesting that the Yin-Yang temperament is quite stable and measurable concept and the SPQ would be considered as an objective and reliable personality assessment.

생물학적 동등성 시험에서 추가시험의 일관성 검정에 대한 소고 (Some Remarks on Consistency Test of Add-on Test in Bioequivalence Trials)

  • 하명호;박상규
    • Communications for Statistical Applications and Methods
    • /
    • 제19권1호
    • /
    • pp.47-55
    • /
    • 2012
  • 식품의약품안전청에서는 제제간의 생물학적 동등성의 입증이 실패했을 경우 추가시험을 허용하는 시험 기준을 2008년 7월부터 시행하고 있다. 생물학적 동등성 시험의 추가시험규정은 원시험에서의 동등성 평가가 불충분한 시험 예수 때문에 실패했을 때 별도의 재시험 시험계획서를 제출하지 않고 피험자수를 증가시켜 다시 시험하여 제제간의 동등성을 평가할 수 있는 근거를 마련한 점에 긍정적이다. 하지만 최근 추가시험의 규정에 따라 군당 12명 이상의 피험자를 사용했을 경우 오히려 추가시험의 일관성 검정 규정을 만족하지 못하여 추가시험이 실패되는 경우가 자주 발생하고 있어 추가시험규정에 대한 불만이 고조되고 있다. 본 연구에서는 이러한 상황이 발생되는 통계적 원인을 살펴보고 현 기준을 일본 규정처럼 조금 더 일반화하게 되면 추가시험을 더 폭넓게 사용할 수 있는 것을 제안하고자 한다.

쌀 전분의 노화 특성에 관한 연구 (Studies on the Retrogradation Properties of Rice Starch)

  • 이찬
    • 한국식품영양학회지
    • /
    • 제16권2호
    • /
    • pp.105-110
    • /
    • 2003
  • 밥의 식미에 영향을 주는 쌀품종별 노화특성에 관한 연구에서 아밀로오스 함량과 gel consistency가 다른 5가지 품종에 대하여 조사하였다. Brabender amylograph에 의한 쌀품종별 호화특성에서는 아밀로오스 함량에 관계없이 hard gel인 품종이 높은 setback 값을 보였다. 저장시의 경도변화에서는 아밀로오스 함량이 높은 품종의 최종경도가 더 높았다. 또한 Avrami equation에 의한 쌀전분겔의 노화특성 연구에서도 아밀로오스 함량이 높은 품종에서 노화속도를 나타내는 지표로서 사용되는 time constant(l/k)값이 더 높은 것으로 나타남에 따라 아밀로오스 함량이 쌀전분의 노화현상에서 매우 중요한 요인라는 것을 알 수 있었다.

CaridexTM Caries Removal System이 우식상아질 제거에 미치는 영향 (AN EXPERIMENTAL STUDY OF THE EFFECT OF CARIDEXTM CARIES REMOVAL SYSTEM ON THE REMOVAL OF CARIOUS DENTIN)

  • 김현선;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제15권1호
    • /
    • pp.129-139
    • /
    • 1990
  • In order to determine if GK-101E(N-monochloro-DL-2-aminobutyrate) solution was effective in the removal of carious dentin, this study was conducted on 75 extracted human carious teeth. GK-101E solution was compared in effectiveness to saline solution.75 extracted human carious teeth were randomly assigned to two groups accordingly : (1) 50 teeth were treated with GK-101E solution : and (2) 25 teeth were treated with saline solution. Teeth in each group were divided into the medium or medium-hard consistency. Treatment consisted of directing the pulsating stream of each coded test solution utilizing the Caridex$^{TM}$ Caries Removal System against the carious surface for 4 mimutes. One operator treated all teeth with corded solution, and four investigators scored on the treated teeth based on visual examination and tactile evaluation with a dental explorer in conjunction with staining method with Caries Detector$^{TM}$ The results were as follows : 1. All groups showed various effect of carious dentin removal. 2. GK-101E solution was statistically superior to physiologic saline solution in the removal of carious dentin, regardless of carious consistency. 3. GK-101E solution in the medium-hard consistency was statistically superior to that in the medium consistency in the caries removal(p=0.001). 4. Saline solution in the medium consistency was equivalent to that in the medium-hard consistency in caries removal(p>0.1).

  • PDF

아동용 Luria-Nebraska 신경심리검사의 한국 표준화를 위한 예비연구 (A Preliminary Study for a Korean Version of the Luria-Nebraska Neuropsychological Battery-Children's Revision)

  • 강차연
    • 아동학회지
    • /
    • 제13권2호
    • /
    • pp.203-216
    • /
    • 1992
  • The purpose of this study was to investigate the utility of the Luria-Nebraska Battery-Children's Revision (LNNB-CR) in the clinical situation in Korea: LNNB-CR was applied clinically in order to examine how well it differentiates brain damaged children from normals. Subjects were 30 children with the average age of 10 years. Among them 15 were diagnosed as the 'brain damaged' group, and the remaining 15 were normal. All subjects of the two groups were tested on all items in accordance with LNNB-CR manual. Data were analyzed by percentage, correlation coefficient, and t-test. The results were (1) the degree of consistency between testers averaged 97.2% which confirmed the stability of the scoring system. (2) Split-half reliability was ranged from .75 on the Tactile Scale (C3) to .95 on the Memory Scale (C10). Thus, consistency of items within the scales appeared high. (3) Internal consistency reliability ranged from .74 on the Visual Scale (C4) to .98 on the Reading Scale (C9). Thus, the homogenity of items within the scales appeared high. (4) In the diagnostic discriminative power test between the two groups, both individual scales and total scores showed significant differences at the level of p<.001. (5) The discriminative power test between two groups on all items showed significant differences at the level of p<.05 or better in 126(85%) out of 149 items. These results are supportive of the diagnostic utility of the application of LNNB-CR to the clinical situation in Korea. However, extensive additional research is needed in order to prove its worth.

  • PDF

Comparisons of Fit Factors Between Two Quantitative Fit Testers (PortaCount vs. MT)

  • Don-Hee Han;Hyekyung Seo;Byoung-kab Kang;Hoyeong Jang;HuiJu Kim;SuA Shim
    • Safety and Health at Work
    • /
    • 제13권4호
    • /
    • pp.500-506
    • /
    • 2022
  • This study evaluated the consistency between two quantitative fit test devices with different methods of ambient aerosol counting. Three types of respirators (N95, half mask, and full facepiece) were worn by 50 participants (male, n = 25; female, n = 25), PortaCount (Pro+ 8038) and MT (05U) were connected to one probe to one mask, and fit factors (FFs) were measured simultaneously with the original and modified protocols. As a result of comparing MT FFs with PortaCount FFs as references and by applying for the pass/fail criteria (FF = 100), the consistency between the two devices for half masks and full facepieces was very high. N95 was somewhat weaker than the two type of respirators in the consistency; however, the correlation between the two devices was very strong (p < 0.0001). The results showed that an FF of 100 as measured by PortaCount was likely to be measured as 75 by the MT. Therefore, when performing the fit test for N95 using the MT and pass level of FF 100, a certain level of adjustment is necessary, whether end-user or putting a scaling factor by manufacturer.

무릎관절 전치환술 환자에 대한 WOMAC 지수의 신뢰도와 타당성에 관한 연구 (Study of the Reliability and Validity of the WOMAC Index in Patients with Total Knee Replacement )

  • 조훈;김경;임상철
    • 대한물리의학회지
    • /
    • 제18권2호
    • /
    • pp.93-101
    • /
    • 2023
  • PURPOSE: The Western Ontario and McMaster Universities Arthritis (WOMAC) index has been used to measure the outcome of total knee replacement (TKR), but studies on its reliability and validity are limited. The present study examined the reliability and validity of this index for patients with knee osteoarthritis who underwent TKR. METHODS: Seventy-one inpatients and outpatients who underwent bilateral TKR for knee osteoarthritis were included in this study. The pain assessment scale and WOMAC index were used to evaluate the participants every two weeks to examine the test-retest reliability, internal consistency, and construct validity. RESULTS: The test-retest reliability scores for pain, stiffness, and physical function were .75-.92, .85-.90, and .75-.95, respectively. The corresponding intraclass correlation coefficients were .75-.88, .76-.88, and .71-.95, respectively. The internal consistency score in the first and second examinations was .92. Furthermore, the construct validity scores for pain, stiffness, and physical function were .83, .41, and .58, respectively. CONCLUSION: The application of the WOMAC index in patients who underwent TKR showed high test-retest reliability and internal consistency with the use of the WOMAC index and good validity with the use of the pain assessment scale.

합리적 쌍대비교행렬에서 일관성에 대한 새로운 기준 (New Criteria for the Consistency in Reasonable Pairwise Comparison Matrices)

  • 김재범;조용곤;김윤배;조근태
    • 대한산업공학회지
    • /
    • 제36권1호
    • /
    • pp.1-6
    • /
    • 2010
  • The Analytic Hierarchy Process (AHP) has been applied widely in various decision making fields. One of advantages of the AHP is the consistency test. However, it has several problems such as the limit of its concept, the limit of 9 scales and stern criteria, contradictory pairwise comparison. In this paper, we propose new criteria for the consistency with more realistic and ideal conditions. To derive the criteria, we conduct the simulation and use the bootstrap method, which is one of resampling techniques in the simulation area.