• Title/Summary/Keyword: Connection line

Search Result 616, Processing Time 0.029 seconds

Coordinate and Length of Straight Transmission Line Minimally connecting X-Y axis via a Specific Point (특정지점을 경유하며 X-Y 축을 최단거리로 연결하는 전선로의 길이 산정)

  • Lee, Sang-Joong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.65-70
    • /
    • 2015
  • Minimal line length enables low-cost construction of the transmission lines and low-loss transportation of electric power. This paper presents a derivation to determine the coordinate and length of the straight line that minimally connects two perpendicular lines x-axis and y-axis via a specific point, using the optimization technique. The author shows a formula to obtain the minimal length, which is represented by the cube root of the coordinate given by the specific point. Case studies have been also discussed to prove the optimal solutions derived by the proposed formula.

Chaos Secure Communication using Chua Circuit with Equivalent Power Lines (등가 전력선을 가진 Chua 회로에서의 카오스 비밀통신)

  • 배영철
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.263-266
    • /
    • 2000
  • In this paper, we formed a transmitter and receiver by using two identical Chua's circuits and then formed wireless transmission line from the channel which was between those two circuits. We proposed a secure communication method in which the desired information signal was synthesized with the chaos signal created in a Chua's circuit and sent to the transmitter through channel. Then the signal was demodulated receiver of Chua's circuit. The method we used to accomplish the sun communication was synthesizing the desired information with the chaos circuit by parallel connection in a wireless transmission line. After transmitting the synthesized signal to the wireless transmission line, we confirmed the actuality of the secure communication by separating the information signal and the chaos signal in the receiver. In order to confirm the security, we compared the wiretapped signal and the recovery signal under the assumption that the wiretapping had taken place. In order to separate the two signals, we transformed the information signal to a current source in the transmitter and detected the current in the receiver.

  • PDF

Selection of Optimal Railway Line by Analyzing of VE/LCC (VE/LCC 분석을 통한 노선 평가 및 최적노선 선정)

  • Lee, Dong-Wook;Kwak, Dong-Koo;Lee, Tai-Sik
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1001-1006
    • /
    • 2004
  • Selection of optimal railway line is taken into consideration include of the purpose of railway, geographical features and facility of management. This study performed opinions of specialists, checking of industrial environment, analysis of bid guideline to select the optimal line and executed AHP method to make quality model and choose weight factors. Therefore, this study executed about six categories which are the efficiency of transportation, facility of planning and construction, economical efficiency, coincidency of planning, the civil appeal and environmental standards, connection with system, and indicated the differences of other method by analyze into specific factors of each categories.

  • PDF

Chaos Secure Communication Using Chua Circuit (Chua 회로에서의 카오스 비밀통신)

  • 배영철
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.238-241
    • /
    • 2000
  • In this paper, we formed a transmitter and receiver by using two identical Chua's circuits and then formed wireless transmission line from the channel which was between those two circuits. We proposed a secure communication method in which the desired information signal was synthesized with the chaos signal created in a Chua's circuit and sent to the transmitter through channel. Then the signal was demodulated receiver of Chua's circuit. The Method we used to accomplish the secure communication was synthesizing the desired information with the chaos circuit by parallel connection in a wireless transmission line. After transmitting the synthesized signal to the wireless transmission line, we confirmed the actuality of the secure communication by separating the information signal and the chads signal in the receiver. In order to confirm the security, we compared the wiretapped signal and the recovery signal under the assumption that the wiretapping had taken place. In order to separate the two signals, we transformed the information signal to a current source in the transmitter and detected the current in the receiver.

  • PDF

A New Algorithm of The Line to Ground Fault Section Isolation & Restoration in Ungrounded Distribution Power System (비접지 배전 계통에서 지락사고 시 고장구간 분리 및 복구를 위한 새로운 알고리즘)

  • Choi In. S.;Choi Myeon. S.;Lim Seong. I.;Lee Seung. J.
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.10
    • /
    • pp.550-555
    • /
    • 2004
  • Fault section isolation and service restoration are very important for function of DAS. In Japan, a progressive protection method is used for the line to ground fault section isolation and service restoration. But the progressive protection method has a drawback that the customer will experience outage time and that the rate in use of the feeder is not over 50%. This paper presents a new Service Restoration Algorithm which is for the line to ground fault section isolation and service restoration method for a ungrounded distribution system. If the proposed algorithm is used, the rate in use of the feeder can improve than before because a distribution system can change multi connection of feeder and the customer's outage time can be reduced. The proposed algorithm has been successfully tested in a distribution system.

Real-Time Measurement of Fry in the Cultivation Field Using a Line-Image Sensora

  • Ishimatsu, T.;Kawasue, K.;Kumon, T.;Ochiai, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.822-825
    • /
    • 1988
  • In this paper, we present a system which enables a real-time measurement of the number and also the body length of the fry (baby fish) using a line image sensor. Here, we consider a situation that fry are transported from a pond to another, pond through a pipe. At one position of the pipe a transparent rectanglar channel is mounted. The images of the fry, which run through this rectanglar channel, are detected by a line image sensor. The image signals are digitized to binary ones and the contour of the fry are detected. After that, a real-time image analysis is executed with a digital signal processor. Labeling program analyses the connection of every pixel. The results are transfered to a personal computer and displayed on the online monitor graphically.

  • PDF

Asymmetric Cascaded Coupled tine Couplers (비대칭 직렬 연결 결합선로 결합기)

  • Park Myun-Joo;Lee Byungje
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.4 no.2 s.7
    • /
    • pp.67-72
    • /
    • 2005
  • This work proposes a novel coupled line coupler structure based on the asymmetric cascaded connection of coupled lines. The proposed structure can be designed in smaller size than conventional single section coupled line couplers. Also, the additional design freedom offered by the proposed structure can serve many useful purposes such as the output phase control or the flexible coupler layout for complex circuit routing environments.

  • PDF

A design of $90^{\circ}$ hybrid phase shifter using ferroelectric materials (강유전체를 사용한 $90^{\circ}$ 하이브리드 구조의 위상 변위기 설계)

  • Kim, Young-Tae;Ryu, Han-Cheol;Lee, Su-Jae;Kwak, Min-Hwan;Moon, Seung-Eon;Kim, Hyeong-Seok;Park, Jun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1919-1921
    • /
    • 2002
  • In this paper, we were designed the ferroelectric phase shifter using 3-dB, $90^{\circ}$ branch-line hybrid coupler with two ports terminated in symmetric phase-controllable reflective networks. The design of phase shifter is based on reflection theory of terminating circuits. In order to find the optimum conditions of reflect phase, the effect of a change of capacitance and transmission line connected with two coupled ports of a coupler have been investigated. To obtain more accurate design parameters, finite element method is applied. We were showed large phase variation with small capacitance variation in the parallel connection of capacitor and transmission line by using EM-simulation and circuit-simulation.

  • PDF

Steady-State Harmonic Domain Matrix-Based Modeling of Four-Quadrant EMU Line Converter

  • Wang, Hui;Wu, Mingli;Agelidis, Vassilios G.;Song, Kejian
    • Journal of Power Electronics
    • /
    • v.14 no.3
    • /
    • pp.572-579
    • /
    • 2014
  • As a non-linear time variant system, the four-quadrant line converter of an electric multiple unit (EMU) was expressed by linear time periodic functions near an operating point and modeled by a steady-state harmonic domain matrix. The components were then combined according to the circuit connection and relations of the feedback control loops to form a complete converter model. The proposed modeling method allows the study of the amplitude of harmonic impedances to explore harmonic coupling. Moreover, the proposed method helps provide a better design for the converter controllers, as well as solves the problem in coordination operation between the EMUs and the AC supply. On-site data from an actual $CRH_2$ high-speed train were used to validate the modeling principles presented in the paper.

Experimental Tests and Analytical Study for the Prediction of the Plastic Moment Capacity of an Unstiffened Top and Seat Angle Connection (무보강 상·하부 ㄱ형강 접합부의 소성휨모멘트 저항능력 예측을 위한 실험 및 해석적 연구)

  • Yang, Jae-Guen;Choi, Jung-Hwan;Kim, Hyun-Kwang;Park, Jae-Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.5
    • /
    • pp.547-555
    • /
    • 2011
  • An unstiffened top and seat angle connection is a type of partially restrained connection that is suitable for low- and medium-rise steel buildings. The plastic moment resisting capacity of such connection is needed in practical design, in addition to the accurate prediction of the initial rotational stiffness. Therefore, most of the studies conducted for the mentioned connections were performed to predict the initial stiffness and the plastic moment resisting capacity with varying geometric properties. The main parameters of such experimental tests were the thickness and high-strength bolt gauge distance of AISC LRFD-type A top and seat angle connections. Based on the test results, the analytical model was also proposed in this study. The applicability of the proposed model was verified by comparing the test results from this study with those of other studies.