• 제목/요약/키워드: Connection facilities

Search Result 404, Processing Time 0.027 seconds

A Study on electric facilities plan and application of low-voltage grid connection for a photovoltaic electric power station (태양광 발전소의 전기설비 설계 및 저압 계통연계 적용사례에 관한 연구)

  • Lim, Kyung-Mi;Kim, Kyeong-Hwa
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.305-308
    • /
    • 2009
  • This paper resents a study on the electric facilities plan and application of low-voltage grid connection for a photovoltaic electric power station. The analysis for an installation cost is carried out and a new plan to solve the problem caused by a voltage drop in a low-voltage grid connection is devised. It is expected that the results can be usefully applied to spread the photovoltaic electric power station.

  • PDF

A Study on the Floor Plan Type and the Spatial Composition of Standard Mental Health Centers in Seoul (서울시 기초정신건강증진센터의 평면유형 및 소요공간구성에 관한 연구)

  • Lim, Yen Jung;Chai, Choul Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.20 no.1
    • /
    • pp.45-55
    • /
    • 2014
  • Purpose: The purpose of this study is to provide data on the basis for architectural planning of floor plan type and spatial composition by analysing standard mental health centers in Seoul. Methods: Data were collected through literature research, field surveys, and expert interviews to 22 standard mental health centers in Seoul. Results: The results of this study could be summarized as follows; Firstly, Mental Health Center is divided into five types according to the location. Location types of mental health center were 'Director type', 'Health center connection type', 'Public facilities connection type', 'Complex center connection type' and 'Commercial Facilities connection type'. Secondly, Depending on the type of management a mental health center is divided into two types. Types are 'Complex type' and 'Independent type'. Average area of 'Complex type' is $192.99m^2$ and 'Independent type' is $266.87m^2$. This difference affects the various spaces. Implications: It is necessary to give and architectural suggestion of mental health center in response to the proposal of the system.

A study on the exchange Kaesong area of goods transport train by the inter-Korean Railway Connection (남북철도 연결에 따른 개성지역 화물열차운행에 대한 연구)

  • Park Hong-Soon
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1671-1676
    • /
    • 2004
  • This thesis watches for the present condition of both economic exchange and goods transport between South and North Korea focused on material side as a provision for the railway connection between them. This is also a predicting thesis for a smooth goods transport in case of setting up a goods transport system between south and North Korea predicting transport demand for the connection of a railway and road studying fundamental facilities and transport related laws.

  • PDF

A study on the Exchange of goods transport freight by the Inter-Korean Railway Connection (남북철도 연결에 따른 화물운송에 대한 연구)

  • Park Hong-Soon
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.190-195
    • /
    • 2003
  • This thesis watches for the present condition of both economic exchange and goods transport between South and North Korea focused on material side as a provision for the railway connection between them. This is also a predicting thesis for a smooth goods transport in case of setting up a goords transport system between south and North Korea predicting transport demand for the connection of a railway and road studying fundamental facilities and transport related laws.

  • PDF

Intelligent Diagnostic System of Photovoltaic Connection Module for Fire Prevention (화재 예방을 위한 태양광 접속반의 지능형 진단 시스템)

  • Ahn, Jae Hyun;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.3
    • /
    • pp.161-166
    • /
    • 2021
  • To prevent accidents caused by changes in the surrounding environment or other factors, various protection facilities are installed at the photovoltaic connection module. The main causes of fire are sparks due to foreign substances inside the photovoltaic connection module through high temperature rise and dew condensation in the photovoltaic connection module, and fire due to heat from the power diode. The proposed method can predict the fire by measuring flame, carbon dioxide, carbon monoxide, temperature, humidity, input voltage, and current on the photovoltaic connection module, and when the fire conditions are reached, fire alarm and power off can be sent to managers and users in real time to prevent fire in advance.

A Basic Study on the Space-Program in Performance Facilities (공연시설의 스페이스프로그램에 관한 기초적 연구)

  • Hwang Mee-Young;Ko Jae-Min
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.1 s.54
    • /
    • pp.113-120
    • /
    • 2006
  • This study analyzes the space composition and the construction system of performance facilities, and research the area construction ratio of each necessary space to establish the specialized performance facilities. This study aims the exclusive facilities for opera among the various performance facilities at home and abroad. The results are as following, 1) Performance space is divided into Public space, Performance space and Administration space on the basis of user. 2) The difference in the scale of performance facilities depends on the fractionation of performance supporting facilities and the grade of specialty rather than the number of seats. 3) The scale and zoning of space in the performance facilities to be built in the future, it is necessary to consider ensuring the production support space, the organic connection of support space and the integrated public space.

A Study on the Revision of the Fire Safety Standard of the Fire Department Connection (연결송수관설비 화재안전기준(NFSC 502) 개정에 관한 연구)

  • Jang, Gyeong-Nam;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.67-76
    • /
    • 2018
  • Among the firefighting facilities, the fire department connection during firefighting is more important than any other facilities at the firefighting site to supply fire water. This study examined the water supply port of a fire department connection installed at an apartment building based on the Standard for Fire Safety (NFSC 502). The time of discovery was measured by fire fighters who knew or did not know of the water supply port installed in the apartment building, and by separating day and night. To maximize the use of the fire department connection which is the full fire extinguisher facility used by the fire brigade based on the results of the experiment, the author suggests improvement proposals that can clarify the installation location and install the location sign of the fire department connection for the Standard for Fire Safety (NFSC 502).

A Study on the Healing Environment with Architectural Spatial Composition in Healthcare Facilities - Focused on the Space Analysis of Sou Fujimoto's Healthcare Projects (의료시설 내 건축공간구성을 통한 치유환경 조성에 관한 연구 - 소우 후지모토 의료시설 사례들의 공간분석을 중심으로)

  • Jeong, Taejong
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.2
    • /
    • pp.17-25
    • /
    • 2019
  • Purpose: The analysis of spatial composition is required for the creation of healing environment in healthcare facilities. This study has been accomplished to provide basic data for the planning and design of hospital architecture. Methods: Literature review of healing environment and investigation on characteristics of spatial composition in healthcare facilities have been conducted. The architectural plans of four Sou Fujimoto's healthcare projects have been analyzed with space syntax. Results: The result of this research can be summarized as followed. First of all, the healing environments are consisted with architectural composition in addition to physical and psychological factors for healing environment. The second one is that the characteristics of spatial composition in Sou Fujimoto's healthcare projects are different private/public/corridor relationships in program configuration, loop or one direction circulation, combined or independent corridor with program, and radical or linear connection in spatial connection methods. The third one is that the characteristics of spatial composition in selected cases through space syntax are high variation on integration, low variation on connectivity, and high distribution in main circulation on ERAM(3). Implications: In addition to the specific spatial composition in healthcare facilities of the architect's project, it is necessary to analyze the relationship with other factors and facilities to develop the planning of hospital architecture.

Housing Values and Satisfaction of the New Town Bundang Apartment Residents (서울 근교 신도시 , 분당지역 아파트 거주자의 주거가치와 주거만족)

  • 조성명
    • Journal of the Korean housing association
    • /
    • v.8 no.1
    • /
    • pp.77-85
    • /
    • 1997
  • The purpose of this study was to estimate the quality if New Town housing environment, and to present the direction of design policy to elevate it. For this study questionnaires were administrated to 272 homemakers living in apartment in Bundang. From 1st of May to 31st of May in 1995. Used statistical method was Frequency. Percentage. Mean, Factor Analysis, Correlation, Multiple Regression. The major finding is as follows : 1) Housing values were classified into five types : convenience, beauty, sociality, education, and economy, Resident ranked first economy among housing values the second is convenience, the third beauty, the forth education, while the most unimportant value is sociality. 2) House satisfaction was classified into four types : house size and plane structure, environment and facilities, interior decoration materials and facilities and building design. Residents were found to show the middle degree satisfaction on their house. 3) Housing complex satisfaction was ciassified four types : community facilities, management stage, neighborhood connection and complex facilities. Resident showed dissatisfaction on their apartment complex relatively. 4) Residents showed dissatisfaction on the interior decoration materials and facilities, local facilities and management attitude relatively.

  • PDF

Algorithm for the ATM Switching Node Location Problem (ATM 교환기의 위치 선정 문제에 관한 연구)

  • 김덕성;이경식;박성수;박경철
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.24 no.3
    • /
    • pp.93-107
    • /
    • 1999
  • We consider the development of an integer programming model and algorithm for the ATM switching node location problem. There are two kinds of facilities, hub facilities and remote facilities, with different capacities and installation costs. Each customer needs to be connected to one or more hub facilities via remote facilities, where the hub(remote) facilities need to be installed at the same candidate installation site of hub(remote) facility. We are given a set of customers with each demand requirements, a set of candidate installation sites of facilities, and connection costs between facilities, We need to determine the locations to place facilities, the number of facilities for each selected location, the set of customers who are connected to each installed hub facilities via installed remote facilities with minimum costs, while satisfying demand requirements of each customer. We formulate this problem as a general integer programming problem and solve it to optimality. In this paper, we develop a branch-and-cut algorithm with path variables. In the algorithm, we consider the integer knapsack polytope and derive valid inequalities. Computational experiments show that the algorithm works well in the real world situation. The results of this research can be used to develop optimization algorithms to solve capacitated facility location problems.

  • PDF