• Title/Summary/Keyword: Connection Characteristic

Search Result 381, Processing Time 0.023 seconds

A Study on the Analysis of Fatigue-fractured Surface of Aluminium for Aircraft (항공기용 Al의 피로파면 분석에 관한 연구)

  • Joo, Won-Kyung;Kwun, Yong-Gu;Bae, Sung-In;Song, Jung-Il
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.274-278
    • /
    • 2007
  • The purpose of this study is to analyze the important loads related with crack-growth in aircraft. Al Alloys mainly used in aircraft are Al2024 and Al7075 in Duralumin. In random fatigue loading, it has been understood crack-growth characteristic using fractured surface photograph by SEM. In order to obtained CTOD, we measured a crack size in wing frame part. As a result of fatigue experiment that accumulating plenty of fatigue loadings, we find more cracks than that produces in the same fatigue loading. The important loads relating to crack-growth was found in the largest strain cycle. Applying strain block in fatigue experiment, it is actually loading in connection of aircraft. In conclusion, These results can be used for preventing an accident owing fatigue-fracture in aircraft.

  • PDF

Response Characteristics of a Nonlinear MDOF Structure with Friction Dampers (마찰형 감쇠기가 설치된 다자유도 비선형 건물의 응답특성)

  • Lee, Sung-Kyung;Park, Ji-Hun;Moon, Byoung-Wook;Min, Kyung-Won;Lee, Sang-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.561-567
    • /
    • 2007
  • This paper deals with the numerical model of a bracing-friction damper system and its deployment using the optimal slip load distribution for the seismic retrofitting of a damaged building. The Slotted Bolted Connection (SBC) type friction damper system was tested to investigate its energy dissipation characteristic. Test results coincided with the numerical ones using the conventional model of a bracing-friction damper system. The placement of this device was numerically explored to apply it to the assumed damaged-building and to evaluate its efficiency. It was found by distributing the slip load that minimizes the given performance indicies based on structural response. Numerical results for the damaged building retrofitted with this slip load distribution showed that the seismic design of the bracing-friction damper system under consideration is effective for the structural response reduction.

  • PDF

An improvement of feedback mathematics instruction based upon the survey (피드백 수학수업의 실태조사에 따른 운영방식 개선)

  • 원승준;남주현
    • Journal of Educational Research in Mathematics
    • /
    • v.12 no.3
    • /
    • pp.313-329
    • /
    • 2002
  • The importance of professor's outline in a feedback instruction was examined through various documents and the way in which the evaluation was fulfilled in Korean educational environment and its reflection upon the evaluation result were investigated by means of research. Based upon the survey results in connection with the progress and basis of teachers' on the spot feedback mathematics instruction in schools, it was found that most of teachers who engaged in feedback mathematics instruction were going over the most frequently missed problems. I proposed that we should bring up the point at issue and grasp its tendency of a class and entire group's results by means of a relative comparative analysis method, and thereupon establish a fixed category and choose substantial feedback scholarship according to that category. From this basis, the sub-sequent research topics include the substantial feedback effects of the selected problems that should be given priority, a group analysed and classified by means of comparison of tendency as well as feedback outline depended on students' characteristic, and the determining factors of tendency(a condition of professors, a level of students, geographical difference(s), and gender difference(s), etc...).

  • PDF

Characteristics Analysis of 3-phase Induction Generator at the Unbalanced Load Operation (불평형 부하 운전시 3상 유도발전기 특성 해석)

  • Kim, Jong-Gyeum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.3
    • /
    • pp.123-128
    • /
    • 2007
  • Hydro power supplies no pollution energy, mainly induction generator has been applied at the small capacity power station. The generating power of small hydro-electric power station connects on the 22.9kV distribution system or low voltage system in the case of three-phase four-wire supply system. There are side effects of various kinds in the 3-three phase 4-wire distribution system mixing 1-phase load and 3-phase load. This system generates the voltage unbalance by unbalanced load operating condition. They have various serious effects on generator and connection system. In this paper, we analyzed what kind of operation characteristic are happened in the induction generator by customer load variation at the 3-three phase 4-wire distribution system.

A Study for Communication Mode of Bus Information System (버스안내정보시스템(BIS) 통신방식 도입에 관한 연구)

  • Lee, Young-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.10 no.4
    • /
    • pp.241-248
    • /
    • 2007
  • It is recently trend that local government which introduce the BIS is increasing steadily. Communication is inevitably necessary to offer a data of a collected bus position to transportation center and supply construed information. Until now, most BIS connection research is actively in data of collecting, processing, offer but Research is Relatively insufficient on communication mode to connect it. Therefore, this study is achieving applicable communication mode on BIS of present common use inning that communication mode. Study resulting, characteristic of BIS communication mode is analyzed that send-receive of short packet data happens frequently and It is inevitably necessary to synthetically analyze economical side, authoritativeness side of communication, introducing communication mode.

  • PDF

The Study Efficiency Characteristics of PV Inverter by Series Arc (아크발생에 따른 태양광 인버터의 효율 특성 연구)

  • Kim, Seung-Eul;Seo, H.U.;Kwon, W.S.;Lee, Y.J.;Han, D.H.;Ban, C.H.;Choe, G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.159-160
    • /
    • 2012
  • For renewable energy has been studied by many research. among them, non-pollution and infinite solar energy using solar power system is newly spotlighed. the DC output characteristic of the solar cell, connection to grid and using the inverter is essential to the process of converter DC to AC. in this paper, study the corresponding changes in the efficiency of the inverter and arcing occurs in the inverter, depending on the conditions and regulations in the UL-1699 series arc occurs.

  • PDF

A Study on the Spatial Characteristics of 'Gwan-gajung' by Analysis of Boundary (觀稼亭'의 경계구조분석을 통한 공간적 특성)

  • 김미나;김경희
    • Journal of the Korean housing association
    • /
    • v.14 no.1
    • /
    • pp.11-18
    • /
    • 2003
  • The purpose of this study is to make clear the identity of Korean traditional housing. And I'm trying to search characteristics of boundary in Korean traditional housing. In this study, I have analyzed boundary of ‘Gwan-gajung’. It is constructed on a square shaped plan, there is an elegant middle court, and a counter-roofed shrine house in the rear of the inner building. In this study, the definition of boundary is made based on what has been perceived as the proper structure, whose characteristics can be described in terms of openness, inside and outside parts and orientation. As a critical factor to spatial qualities, boundary is closely related with the connection and disconnection, background and atmosphere, and inferior and superior relations and hierarchical order from the view of space. The result of study is like followings. The characteristics of boundary in Korean traditional housing is 1. one way direction of penetrability, 2. having the face and the back 3. orientation 4. duplication.

An experimental study on weld characteristic for piping connection part (파이프 연결부위의 용접특성에 관한 실험적 연구)

  • Park, Keyung-Dong;Kim, Dong-Woog
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.226-227
    • /
    • 2005
  • In this study, it was investigated about endurance and fatigue crack propagation rate of according to welding methods of SMAW and FCAW commonly using for welding structures in present. Endurance limits carried out highly in the order of SMAW, FCAW and fatigue crack propagation rate out lowly in the order of SMAW, FCAW. By these results, it is needed to used SMAW welding methods for welding structures with small welding capacity and FCAW methods for large welding structures after consideration about economic gains and operation efficiency of welding. Fatigue crack propagation rate is more effected by strength of welding materials than endurance limit of welding materials according to welding methods..

  • PDF

Structural Behavior of Beam-to-Column Connections with Elasto-Plastic Hysteretic Dampers (탄소성 이력댐퍼를 구비한 접합부의 거동)

  • Oh, Sang-Hoon;Ryu, Hong-Sik;Kim, Young-Ju
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.552-559
    • /
    • 2005
  • The resistance of a structure against an earthquake is related to its ability to absorb the seismic input energy. The development of devices for dissipating the seismically induced energy on the structure is a subject that is receiving large attentionin the field of earthquake engineering. One example of these devices is the steel plate with slits. In this paper, a connection with a slit-type steel plate damper installed at each ends of wide-flange section beam, as an energy absorption element, was proposed. A series of experiment was performed to investigate their behavior and structural characteristic. The main parameters were the aspect ratio of the struts in slit plates, thickness of the struts and height of the vertical plates. Test results indicated that most of the energy was absorbed by plastic deformation of slit plate dampers.

  • PDF

The Operating Characteristics of 3kW Utility Interconnected Photovoltaic System (3kW 계통연계형 태양광발전시스템의 운전특성)

  • Kim, Hyung-Seok;Park, Jeong-Min;Na, Jong-Deok;Baek, Hyung-Rae;Cho, Geum-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.201-204
    • /
    • 2004
  • Consider the optimal design for PV system, it is apply to 3kW interconnected electric power PV system, that is a point of reference for 3kW PV the spread residential section system. Through the driving various practical system, we look into that for efficiency of generation and stability of interconnected system. Using obtained data acquisition, It can be suggest that installation and management for system parameter to optimal design maximum generation electric power. PV system have some losses that are variation radiation, shadow, change temperature, unbalanced grid connection, serial circuit loss, MPP deference loss, PCS loss and so forth. Using obtained various performance characteristic result, we can make database in the future, through the this study, we can get the reliance and have regard to spread PV system.