• 제목/요약/키워드: Connected-Component

검색결과 534건 처리시간 0.022초

SIMPLE MODELS TO INVESTIGATE THE EFFECT OF VELOCITY DEPENDENT FRICTION ON THE DISC BRAKE SQUEAL NOISE

  • Shin, K.;Brennan, M.J.;Joe, Y.G.;Oh, J.E.
    • International Journal of Automotive Technology
    • /
    • 제5권1호
    • /
    • pp.61-67
    • /
    • 2004
  • This paper suggests two simple two-degree-of-freedom models to describe the dynamical interaction between the pad and the disc of a disc brake system. Separate models for in-plane and out -of-plane vibration are described. Although a brake pad and disc have many modes of vibration, the interaction between a single mode of each component is considered as this is thought to be crucial for brake noise. For both models, the pad and the disc are connected by a sliding friction interface having a velocity dependent friction coefficient. In this paper, it is shown that this friction model acts as negative damping in the system that describes the in-plane vibration, and as negative stiffness in system that describes the out-of-plane vibration. Stability analysis is performed to investigate the conditions under which the systems become unstable. The results of the stability analysis show that the damping is the most important parameter for in-plane vibration, whereas the stiffness is the most important parameter for the out-of-plane vibration.

원격 제어 서비스를 지원하는 통합 홈 엔터테인먼트 시스템 (An Integrated Home Entertainment System supporting Remote Control Service)

  • 이현주;김상옥;김상욱
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제34권3호
    • /
    • pp.219-225
    • /
    • 2007
  • UPnP AV 프레임워크는 홈 네트워크 미들웨어 기술의 중요한 부분으로 네트워크에 접속한 다양한 AV 디바이스를 투명적으로 통합 및 관리한다. 그러므로 사용자는 언제 어디서나 AV 컨텐츠를 접근 및 제어할 수 있다. 기존의 흠 엔터테인먼트 시스템들은 멀티미디어 흠 서버 위주로 PC 환경에서 멀티미디어 컨텐츠의 서비스 제공을 목표로 하고 있다. 본 논문에서는 원격 제어 서비스를 지원하는 통합 홈 엔터테인먼트 시스템(u-MUSE 시스템) 개발에 대하여 설명한다. 제안하는 시스템은 기존의 홈 엔터테인먼트 서비스 외에 가정에서 멀리 떨어져있는 AV 디바이스의 어플리케이션을 조작하거나, AV 컨텐츠를 직접 제어할 수 있다. 이 시스템은 통합 시스템 제어 및 AV 컨텐츠 재생 서비스를 지원하여 가정에서의 가전 디바이스 제어 센터의 역할을 충분히 수행한다.

Correction of Signboard Distortion by Vertical Stroke Estimation

  • Lim, Jun Sik;Na, In Seop;Kim, Soo Hyung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제7권9호
    • /
    • pp.2312-2325
    • /
    • 2013
  • In this paper, we propose a preprocessing method that it is to correct the distortion of text area in Korean signboard images as a preprocessing step to improve character recognition. Distorted perspective in recognizing of Korean signboard text may cause of the low recognition rate. The proposed method consists of four main steps and eight sub-steps: main step consists of potential vertical components detection, vertical components detection, text-boundary estimation and distortion correction. First, potential vertical line components detection consists of four steps, including edge detection for each connected component, pixel distance normalization in the edge, dominant-point detection in the edge and removal of horizontal components. Second, vertical line components detection is composed of removal of diagonal components and extraction of vertical line components. Third, the outline estimation step is composed of the left and right boundary line detection. Finally, distortion of the text image is corrected by bilinear transformation based on the estimated outline. We compared the changes in recognition rates of OCR before and after applying the proposed algorithm. The recognition rate of the distortion corrected signboard images is 29.63% and 21.9% higher at the character and the text unit than those of the original images.

Characteristics of the magnetic flux-offset type FCL by switching component

  • Jung, Byung-Ik;Choi, Hyo-Sang
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권2호
    • /
    • pp.18-20
    • /
    • 2016
  • The study of superconducting fault current limiter (SFCL) is continuously being studied as a countermeasure for reducing fault-current in the power system. When the fault occurred in the power system, the fault-current was limited by the generated impedance of SFCLs. The operational characteristics of the flux-offset type SFCL according to turn ratios between the primary and the secondary winding of a reactor were compared in this study. We connected the secondary core to a superconductor and a SCR switch in series in the suggested structure. The fault current in the primary and the secondary winding of the reactor and the voltage of the superconductor on the secondary were measured and compared. The results showed that the fault current in the load line was the lowest and the voltage applied at both ends of the superconductor was also low when the secondary winding of the reactor had lower turn ratio than the primary. It was confirmed based on these results that the turn ratio of the secondary winding of the reactor must be designed to be lower than that of the primary winding to reduce the burden of the superconductor and to lower the fault current. Also, the suggested structure could increase the duration of the limited current by limiting the continuous current after the first half cycle from the fault with the fault current limiter.

Synthesis of ZrTiO4 and Ta2Zr6O17 Films by Composition-Combinatorial Approach through Surface Sol-Gel Method and Their Dielectric Properties

  • Kim, Chy-Hyung
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권9호
    • /
    • pp.1463-1466
    • /
    • 2007
  • Single phases of multi-component oxides films, ZrTiO4 and Ta2Zr6O17, could be synthesized by using the combinatorial approach through surface sol-gel route, coating the appropriate mole ratio of 100 mM zirconium butoxide, tantalum butoxide and titanium butoxide precursors on Pt/Ti/SiO2/Si (100) substrate, following pyrolysis at 450 oC, and annealing them at 770 oC. Both the films and bulks of ZrTiO4 and Ta2Zr6O17 showed very stable dielectric properties in temperature range, ?140 to 60 oC, and frequency range, 100 Hz to 1 MHz, promising their applications in wide range of temperatures and frequencies. The dielectric constants of the films were lower and a little more dependent on frequency than those of the bulks. The reduction of dielectric property in the film was mainly due to the interfacial effects that worked as series and parallel-connected capacitances toward the substantial film capacitance.

결합 신경망을 이용한 여권 MRZ 정보 인식 (Recognition of Passport MRZ Information Using Combined Neural Networks)

  • 김진호
    • 디지털산업정보학회논문지
    • /
    • 제15권4호
    • /
    • pp.149-157
    • /
    • 2019
  • In case of reading passport using a smart phone in contrast with a dedicated passport reading system, MRZ(Machine Readable Zone) character recognition can be hard when the character strokes were broken, touched or blurred according to the lighting condition, and the position and size of MRZ character lines were varied due to the camera distance and angle. In this paper, the effective recognition algorithm of the passport MRZ information using a combined neural network recognizer of CNN(Convolutional Neural Network) and ANN( Artificial Neural Network), is proposed under the various sized and skewed passport images. The MRZ line detection using connected component analysis algorithm and the skew correction using perspective transform algorithm are also designed in order to achieve effective character segmentation results. Each of the MRZ field recognition results is verified by using five check digits for deciding whether retrying the recognition process of passport MRZ information or not. After we implement the proposed recognition algorithm of passport MRZ information, the excellent recognition performance of the passport MRZ information was obtained in the experimental results for PC off-line mode and smart phone on-line mode.

Local Similarity based Document Layout Analysis using Improved ARLSA

  • Kim, Gwangbok;Kim, SooHyung;Na, InSeop
    • International Journal of Contents
    • /
    • 제11권2호
    • /
    • pp.15-19
    • /
    • 2015
  • In this paper, we propose an efficient document layout analysis algorithm that includes table detection. Typical methods of document layout analysis use the height and gap between words or columns. To correspond to the various styles and sizes of documents, we propose an algorithm that uses the mean value of the distance transform representing thickness and compare with components in the local area. With this algorithm, we combine a table detection algorithm using the same feature as that of the text classifier. Table candidates, separators, and big components are isolated from the image using Connected Component Analysis (CCA) and distance transform. The key idea of text classification is that the characteristics of the text parallel components that have a similar thickness and height. In order to estimate local similarity, we detect a text region using an adaptive searching window size. An improved adaptive run-length smoothing algorithm (ARLSA) was proposed to create the proper boundary of a text zone and non-text zone. Results from experiments on the ICDAR2009 page segmentation competition test set and our dataset demonstrate the superiority of our dataset through f-measure comparison with other algorithms.

EHA 밸브 성능시험 장치 개발 (Development of Performance Test Equipment for Easy-Hill Assist Valve)

  • 정규홍
    • 드라이브 ㆍ 컨트롤
    • /
    • 제11권4호
    • /
    • pp.61-67
    • /
    • 2014
  • When a manual transmission equipped car stops on an incline where the nose of the car is higher than the rear, hill-start control or hill-holder could prevent the vehicle from rolling backward as the car moves forward. The easy-hill assist valve consists of a check valve and a needle type ON/OFF solenoid valve connected in parallel; it is a hydraulic actuator that can maintain brake pressure using an electrical signal from the ECU. As the EHA valve is a safety-related component of the brake system, high reliability as well as superior dynamic performance is required for it to be applied in commercial vehicles. This paper presents the design of the EHA valve as a piece of equipment that can simulate the brake actuation pressure with a pressurizing piston. Following specific test standards, the experimental results validate the implemented functions of the test equipment, proving the test stand to be effective for the performance and endurance of the EHA valve.

저전력 네트워크 기반의 확장 용이한 스마트 홈 IoT 시스템 (An Extensible Smart Home IoT System Based on Low-power Networks)

  • 이준영;유성은
    • 대한임베디드공학회논문지
    • /
    • 제13권3호
    • /
    • pp.133-141
    • /
    • 2018
  • There are increasing interests on smart home systems. However, most of the existing works focus on the functionality itself. In this paper, we propose an extensible smart home system based on low power networking such as CoAP, 6LoWPAN, and Zigbee. The proposed home IoT system consists of Home APP, Home Server, Home Broker, and Power Devices. Each component of the system is connected by the low-power network technologies aforementioned. As the end device, Power Device senses the current consumption of the attached appliance and controls the power to it. Power Device reports the sensing data to Home Server via Home Broker. The Home Broker enhances the scalability of the system. Home Broker extends the service area and the user's services, and it manages the connection of the underlying devices and processes, and transmits data to Home Server from Power Devices. Through the experimental evaluation, we show that the proposed system achieves the design goals such as extensibility and low power networking.

자속결합형 초전도 한류기의 인가전압별 전류제한 효과 (Current Limiting effects of a Flux-Coupling Type SFCL according to applied voltage)

  • 정병익;최효상;조용선;이주형;정수복;오금곤
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.249-251
    • /
    • 2008
  • We investigated a flux-coupling type superconducting fault current(SFCL) limiter. The SFCL consisted of the primary and secondary coils, which were wound in series each other through an iron core. Superconducting unit was connected with secondary coil in parallel. The flux generated from a coil in normal operation is cancelled out by its structure and the zero resistance of the superconducting unit. In this paper. In order to compare the current limiting effects of the SFCL by applied voltage. When a lied voltage was increased, quench time was shortened Fast quench time is important component under the same fault condition because power burden of the SFCL is reduced by that of the superconducting units. The current limiting behavior of flux-coupling type SFCL was dependent upon the applied voltage.

  • PDF