• 제목/요약/키워드: Confocal system

검색결과 176건 처리시간 0.027초

개발 웨이퍼 검사위한 Confocal 이미징 시스템의 개발 (Development of Confocal Imaging System for Wafer Inspection)

  • 고국원;다이 느엔 콩;고경철
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2010년도 춘계학술발표논문집 1부
    • /
    • pp.108-112
    • /
    • 2010
  • Confocal Imaging System is an essential machine for a wide range of inspection wafer. For concurrent and fast acquiring the image data of four channels, the new image acquisition system used the protocol of camera-link standard with the full mode of configuration in interconnection with a frame grabber integrated in a computer, which is popularly used for many cameras, so the programming environment of image processing is optional such as Visual C++, Matlab. In addition, many conventional methods were coordinately used for contribution to build the high quality of images for precise processing analog signals of PhotoMutiplier Tubes(PMTs), accurate control of scanning device, sensitivity of PMTs, and laser source. The prototype of new image acquisition system, could meet the goal of development, it is used in LSCM for high content screening to investigation the processes of elements of living specimens at the same time by simultaneous grab image data on 4 PMTs channels.

  • PDF

파이버 공초점법을 이용한 레이저 빔 자동 초점 제어 장치에 관한 연구 (Study on Auto Focusing System of Laser Beam by Using Fiber Confocal Method)

  • 문성욱;김종배;김선흠;배한성;남기중
    • 한국레이저가공학회지
    • /
    • 제9권3호
    • /
    • pp.7-13
    • /
    • 2006
  • Auto focusing system to find optimized focal position of laser beam used for material process has been investigated by using fiber confocal method. Wavelength of laser diode (LD) and diameter of single-mode fiber are 780nm and $5.3{\mu}m$, respectively. Intensity distributions of beam reflected from the surface of mirror and silicon bare wafer have been observed in a gaussian form. Experimental results show that focal position obtained by LD is shifted from one observed from surface scribed by laser about $80{\mu}m$. It is due to the difference of wavelength and each divergence of between LD and laser used for material process. It is confirmed that auto focusing control system through position calibration has operated steadily.

  • PDF

Rapid Detection of Methicillin Resistant Staphylococcus aureus Based on Surface Enhanced Raman Scattering

  • Han, Dae Jong;Kim, Hyuncheol
    • 대한임상검사과학회지
    • /
    • 제46권4호
    • /
    • pp.136-139
    • /
    • 2014
  • Methicillin-resistant Staphylococcus aureus (MRSA) is one of the severe nosocomial infectious agents. The traditional diagnostic methods including biochemical test, antibiotic susceptibility test and PCR amplification are time consuming and require much work. The Surface enhanced Raman spectroscopy (SERS) biosensor is a rapid and powerful tool for analyzing the chemical composition within a single living cell. To identify the biochemical and genetic characterization of clinical MRSA, all isolates from patients were performed with VITEK2 gram positive (GP) bacterial identification and Antibiotic Susceptibility Testing (AST). Virulence genes of MRSA also were identified by DNA based PCR using specific primers. All isolates, which were placed on a gold coated nanochip, were analyzed by a confocal Raman microscopy system. All isolates were identified as S. aureus by biochemical tests. MRSA, which exhibited antibiotic resistance, demonstrated to be positive gene expression of both femA and mecA. Furthermore, Raman shift of S. aureus and MRSA (n=20) was perfectly distinguished by a confocal Raman microscopy system. This novel technique explained that a SERS based confocal Raman microscopy system can selectively isolate MRSA from non-MRSA. The study recommends the SERS technique as a rapid and sensitive method to detect antibiotic resistant S. aureus in a single cell level.

파이버 공초점법을 이용한 레이저 빔 자동 초점 제어 장치에 관한 연구 (Study on auto focusing system of laser beam by using fiber confocal method)

  • 문성욱;김선흠;김종배;배한성;남기중
    • 한국레이저가공학회:학술대회논문집
    • /
    • 한국레이저가공학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.41-45
    • /
    • 2006
  • Auto focusing system to find optimized focal position of laser beam used for material process has been investigated by using fiber confocal method. Wavelength of laser diode (LD) and diameter of single-mode fiber we 780nm and $5.3{\mu}m$, respectively. Intensity distributions of beam reflected from the surface of mirror and silicon bare wafer have been observed in a gaussian form. Experimental results show that focal position obtained by LD is shifted from one observed from surface scribed by laser about $80{\mu}m$. It is due to the difference of wavelength and each divergence of between LD and laser used for material process. It is confirmed that auto focusing control system through position calibration has operated steadily.

  • PDF

디지털 홀로그래피에서의 공초점 렌즈계를 이용한 보다 큰 물체의 기록 (Recording of larger object by using two confocal lenses in digital holography)

  • 김성규;최현희;손정영
    • 한국광학회지
    • /
    • 제14권3호
    • /
    • pp.244-248
    • /
    • 2003
  • 공초점 렌즈의 조합으로 사용되는 두 렌즈의 초점거리의 비율에 해당하는 비율 만큼 입사되는 광의 입사각을 줄일 수 있다. 이 결과로 CCD상의 간섭 패턴의 공간 주파수가 낮아진다. 따라서 CCD의 구성 화소들의 간격에 의해 한정되는 기록 가능한 공간 주파수 보다 높은 공간 주파수의 간섭 패턴을 기록할 수 있어 보다 큰 물체의 간섭 패턴을 기록할 수 있다. 또한 이러한 광학계로 기록한 간섭 패턴의 수치적 재생(Numerical Reconstrction) 결과에서는 0-차 회절광의 면적이 초점거리 비율의 역수의 제곱에 해당하는 만큼 축소되는 장점이 있다.

Intracellular Trafficking of Transferrin-Conjugated Liposome/DNA Complexes by Confocal Microscopy

  • Lee Sang Mi;Kim Jin-Seok
    • Archives of Pharmacal Research
    • /
    • 제28권1호
    • /
    • pp.93-99
    • /
    • 2005
  • Intracellular trafficking of transferrin-conjugated dimethyldioctadecyl-ammonium bromide liposome $(T_f-liposome)/DNA$ complexes in HeLa cells was studied using the double-labeled fluorescence technique and confocal microscopy. The size of the $T_f-liposome/DNA$ complex was about 367 nm in diameter and the zeta-potential of it at a 5:1 (w/w) ratio was almost neutral. The intracellular pathway of the $T_f-liposome/DNA$ complex, noted as green (FITC), red (rhodamine) or yellow (FITC + rhodamine) fluorescence, was elucidated from the plasma membrane to the endosome (or lysosome), and finally to the nucleus. The results of this study indicate that plasmid DNA enters into the nucleus not only as a free form but as an associated form complexed with $T_f-liposome$. More interestingly, the $T_f-liposome$ undergoes a nuclear location in the form of ordered structures. This could be a very useful piece of information in designing a safe and advanced gene delivery system.

Optical System Design and Evaluation for an Augmented Reality Head-up Display Using Aberration and Parallax Analysis

  • Kim, Kum-Ho;Park, Sung-Chan
    • Current Optics and Photonics
    • /
    • 제5권6호
    • /
    • pp.660-671
    • /
    • 2021
  • We present a novel optical system for an augmented reality head-up display (AR HUD) with two virtual images at different conjugates by employing a confocal off-axis two-mirror and introducing the horopter circle. For a far virtual image with large asymmetrical aberrations, we initially obtain an off-axis two-mirror system corrected for these aberrations and compensated for the down angle by configuring its parameters to satisfy the confocal and Scheimpflug conditions, respectively. In addition, this system is designed to reduce the biocular parallax by matching Petzval surface into the longitudinal horopter circle in a near virtual image. This design approach enables us to easily balance the residual aberrations and biocular parallax when configuring the optical system with two different conjugates, which results in an AR HUD available for near and far virtual images together.

All-in-one adhesive의 다층적용이 미세인장결합강도에 미치는 영향 (THE EFFECT OF MULTIPLE APPLICATION ON MICROTENSILE BOND STRENGTH OF ALL-IN-ONE DENTIN ADHESIVE SYSTEMS)

  • 손성애;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제29권5호
    • /
    • pp.423-429
    • /
    • 2004
  • The purpose of this study was to evaluate the effect of multiple application of all-in-one dentin adhesive system on microtensile bond strength using confocal laser scanning microscope and microtensile bond strength test. Flat occlusal dentin surfaces were prepared using low-speed diamond saw. In group I, Scotchbond Multipurpose (SM) was applied by manufacturer's recommendation. In group II, after Adper Prompt L-Pop was applied for 15s and light cured for 10s. the second coat was re-applied and light-cured. In group III, after light-curing the second layer. the third coat was re-applied and light-cured. Specimens bonded with a resin-composite were sectioned into resin-dentin stick for measuring the adhesive layer thickness by confocal laser scanning microscope and evaluating micro-tensile bond strength. The adhesive layers of three-step dentin adhesive system. 3 coats of Adper Prompt L-Pop had significantly thicker than SM. 2 coats of Adper Prompt L-Pop (p < 0.05). However. there was no significant differences in bond strengths between SM and 3 coats of Adper Prompt L-Pop (p > 0.05). And SM. 3 coats of Adper Prompt L-Pop had significantly higher than 2 coats of Adper Prompt L-Pop in bond strengths (p < 0.05).

손톱하부면 초상(nail bed) 패턴의 콘포칼 광 스케닝 방법을 이용한 추출과 개인인증 (Individual identification by extraction of nail bed pattern of the finger nail using confocal scanning optical system)

  • 김태근;김용우;김해일(주)미래시스
    • 한국광학회지
    • /
    • 제13권2호
    • /
    • pp.155-161
    • /
    • 2002
  • 혼탁매질인 손톱의 하부면에는 개인별로 상이한 융선과 곡 구조의 패턴인 조상(爪床, nail bed)이 있다. 이중 융선에는 혈액이 흐르는 모세혈관 고리(capillary loop)가 밀집되 있고 융선과 융선은 모세혈관 고리가 밀집되 있지 않은 골로 구분되어 있다. 670nm 파장의 레이저 빛은 피부의 진피(dermis)에서 산란특성을 가지며 혈액에는 강하게 흡수된다. 손톱하부면 조상(nail bed)의 이와 같은 생체-광학적 특성에 착안하여 혼파매질인 손톱하부면에 위치하는 조상(nail bed) 패턴을 얻어내는 콘포칼 광 스케닝(confocal optical scanning) 구조를 특징으로 하는 광학계를 제안한다. 그리고 이를 이용하여 개인별로 상이한 조상(nail bed) 패턴을 추출해 조상(nail bed) 패턴간의 correlation를 구해 비교함으로써 개인을 구별해내는 개인인증 기법을 제안한다.

Fiber Optics for Multilayered Optical Memory

  • Kawata, Yoshimasa;Tsuji, Masatoshi;Inami, Wataru
    • 정보저장시스템학회논문집
    • /
    • 제7권2호
    • /
    • pp.53-59
    • /
    • 2011
  • We have developed a compact and high-power mode-locked fiber laser for multilayered optical memory. Fiber lasers have the potential to be compact and stable light sources that can replace bulk solid-state lasers. To generate high-power pulses, we used stretched-pulse mode locking. The average power and pulse width of the output pulse from the fiber laser that we developed were 109 mW and 2.1 ps, respectively. The dispersion of the output pulse was compensated with an external single-mode fiber of 2.5 m length. The pulse was compressed from 2.1 ps to 93 fs by dispersion compensation. The fiber laser we have developed is possible to use as a light source of multilayered optical memory. We also present a fiber confocal microscope as an alignment-free readout system of multilayered optical memories. The fiber confocal microscope does not require fine pinhole position alignment because the fiber core is used as the point light source and the pinhole, and both of which are always located at the conjugated point. The configuration reduces the required accuracy of pinhole position alignment. With these techniques we can present an all-fiber recording and readout system for multilayered memories.