• 제목/요약/키워드: Conference recording

검색결과 585건 처리시간 0.03초

체적 홀로그래픽 메모리에서의 효율적인 인터리빙 기법 (Efficient Interleaving Scheme of Volume Holographic Memory)

  • Seunghoon Han;Kim, Minseung;Byungchoon Yang;Lee, Byoungho
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2003년도 제14회 정기총회 및 03년 동계학술발표회
    • /
    • pp.72-73
    • /
    • 2003
  • In volume holographic memory (VHM), two-dimensional data array (i.e. data page) is used for the recording and the retrieving process with the aid of spatial light modulator (SLM) and CCD camera. Due to this two-dimensional parallel data processing, burst errors in this system also have two-dimensional characteristics in a data page domain. In this paper, we present a channel model of the burst noise and burst error for the VHM system using disk type recording media. (omitted)

  • PDF

디지털 휴대용 생체 기록계 개발에 관한 연구 (A Study on Developement of Portable Digital Bio-signal Recorder)

  • 이호재;전태의;윤충화;허웅
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 춘계학술대회
    • /
    • pp.109-113
    • /
    • 1993
  • In this paper, we devised a simple portable digital recorder for a day life ECG signal recording. The system are consisted of ECG amp. part, signal conditioning part. A/D converter, data compression part and digital memory part. An ADPCM algorithm used at data compress part for 50% of data reduction. The maximum lengths of recording times take 3 hours in 1 mega byte memory.

  • PDF

근접장 광기록용 서스펜션의 최적설계 (Optimal Design of a Near-field Optical Recording Suspension)

  • 조태민;임경화
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.1146-1151
    • /
    • 2003
  • So far the study of near-field optical recording(NFR) suspensions has not been investigated sufficiently. In this study the optimization of a NFR suspension is performed using finite element method. NFR suspensions are required to have low compliance modes to allow the slider to comply with the rotating disk, and high tracking stiffness modes to maximize the servo bandwidth of the tracking controller First of all, a basic integrated type suspension model is obtained using topology optimization And the parametric study on the sensitivities of the compliance modes and tracking stiffness modes is performed. Finally, a model satisfying static characteristics is elected and shape optimization is performed to improve dynamic characteristics.

  • PDF

Effect of structural change on the magnetostriction coefficient in the CoCrPt alloy thin films

  • Im, Mi-Young;Jeong, Jong-Ryul;Shin, Sung-Chul
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2002년도 동계연구발표회 논문개요집
    • /
    • pp.178-179
    • /
    • 2002
  • CoCrPt alloy films are one of the most promising candidates for high-density perpendicular magnetic recording media due to their strong perpendicular magnetic anisotropy (PMA) and high coercivity [1]. In order to achieve high-density magnetic recording media, it is essential to characterize the magnetoelastic properties since experimental and theoretical research has revealed a significant magnetoelastic contribution to the magnetic properties in magnetic thin films. (omitted)

  • PDF

BOTTOM IrMn-BASED SPIN VALVES BY USING OXYGEN SURFACTANT

  • J. Y. Hwang;Kim, M. Y.;K. I. Jun;J. R. Rhee;Lee, S. S.;D. G. Hwang;S. C. Yu;Lee, S. H.
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2002년도 동계연구발표회 논문개요집
    • /
    • pp.62-63
    • /
    • 2002
  • To reach 100 Gbit/in$^2$ magnetic recording densities in hard disk drives specular enhancement of giant magnetoresistance (GMR) effect in spin valve (SV) films has become one of the indispensable means for application as read elements in recording heads [1]. More recently specular spin valve (SSV) structure containing nano-oxides layers (NOL) were reported [2], where MR enhancement is caused to extended mean free path of majority spin polarized electrons through specular reflection at metal/insulator interfaces [3] in the SV films. (omitted)

  • PDF

Effect of Variation of Membrane Thickness on the Activity of $Ca^{2+}$-activated $K^+$ Channel in Planar Lipid Bilayers

  • Seo, Hyoung-Sik;Ryu, Pan-Dong
    • 한국생물물리학회:학술대회논문집
    • /
    • 한국생물물리학회 1999년도 학술발표회 진행표 및 논문초록
    • /
    • pp.56-56
    • /
    • 1999
  • Change of membrane property can affect the activity of membrane proteins. In this work, we investigated the single channel properties of large conductance $Ca^{2+}$-activated $K^{+}$(BK) channels in planar lipid bilayers of different thickness. First, we recorded the activity of single BK channels from rat skeletal muscle incorporated into the control bilayer, then increased the bilayer thickness by perfusing the recording solution with the one saturated with n-pentane, or reduced the thickness by adding diheptanoylphosphatidylcholine (di$C_{7:0}$PC) to the recording soluton.(omitted)

  • PDF

수직자기기록매체용 CoCr박막의 자기적 특성 개선에 관한 연구 (The Improvement of Magnetic Properties of CoCr Thin Film for Perpendicular Magnetic Recording Media)

  • 공석현;손인환;최형욱;최동진;김경환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.419-422
    • /
    • 1999
  • We prepared CoCr thin film for perpendicular magnetic recording media by facing targets sputtering system(FTS system) which can deposit a high quality thin films in plasma-free state and wide range of working pressure. In this study, we investigated that the effect of sputtering condition , that Argon gas pressure and substrate temperature, on magnetic and crystallographic characteristic of CoCr thin film as well as the variation perpendicular coercivity in changing of film's thickness. Crystallographic and magnetic characteristic of prepared thin films were evaluated by x-ray fractometry(XRD), vibrating sample magnetometer(VSM) and kerr hysteresis loop measurement.

  • PDF

시험소 충격전압 측정시스템의 소급성검토 (Review of the tracebility of impulse voltage measuring system in test laboratory)

  • 허종철;최익순;정주영;반석걸;박정후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1632-1634
    • /
    • 2003
  • For lihgtning and switching impulse voltage performances in laboratories, impulse voltage measuring system, which is consisted of voltage divider, recording instrument and connecting system between divider and recording instrument, is used. In order to show reliability of test result in test laboratory, tracebility of these measuring system to be using in test laboratory is needed. In this paper, we describe tracebility and uncertainty of impulse voltage measuring system in test laboratory.

  • PDF

Co-Cr(-Ta) 층의 결정성 및 자기적 특성에 미치는 하지층 효과 (Underlayer effects on crystallographic and magnetic characteristics of Co-Cr(-Ta) layer)

  • 금민종;공석현;가출현;손인환;김경환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.208-211
    • /
    • 2000
  • We prepared Co-Cr-Ta and Co-Cr-Ta/Ti thin film for perpendicular magnetic recording media by facing targets sputtering system (FTS system). Ti underlayer effects on crystallographic and magnetic characteristics of Co-Cr-Ta perpendicular magnetic recording media have been investigated. Crystallgraphic and magnetic characteristic of prepared thin films were evaluated by x-ray diffractometry(XRD), vibrating sample magnetometer(VSM) and kerr hysteresis loop measurement. The coercivity and anisotropy field increase by introduced Ti underlayer when substrate temperature is higher than 150$^{\circ}C$. The c-axis dispersion angle and grain size of Co-Cr-Ta/Ti thin film is decrease than Co-Cr-Ta when substrate temperature is higher than 100$^{\circ}C$. Consequently, the use of a Ti underlayer highly orientated can be improved crystallographic and magnetic characteristics of Co-Cr -Ta perpendicular media layer.

  • PDF

궤도틀림의 검측값과 측량결과 비교 (Comparison of Track Recording with Surveying in Track irregularity Measurement)

  • 이지하;최일윤;김박진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1090-1095
    • /
    • 2008
  • Track geometry changes by traffic loads. The bigger the changes are, the worse the riding comfort and running stability of train. This is so-called track irregularity and is the most important quality parameters of ballasted track. To objectively assess track irregularity, track geometry should be able to be measured. Practically, railway companies use moving chord method, which determine versine values via a chord. The versine is the vertical distance to curve measured in the middle of the chord. This type of method measures only versine of track irregularity curve by transfer function from the characteristics of measuring device. In this report, review the characteristics of two types of measuring tools by comparing the measurements. The one is GRP-1000 system, optical surveying system with Total station and lazar prism trolley. This calculates track geometry by surveying absolute coordinates of two points each on both rail heads. The other is EM-120, measures versine with 10m of symmetrical chord length.

  • PDF