• 제목/요약/키워드: Cone Beam

검색결과 966건 처리시간 0.031초

상악전치부 임플란트 식립 시 상악전치부 치근첨에서 비강저까지 치조골의 수직적 길이 측정 (The Measurement of Vertical Length from the Root Tip of Maxillary Anterior Teeth to Nasal Floor, When Maxillary Anterior Implants Placed)

  • 장해만;김진욱;권대근;장현중;김진수;이상한
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제34권5호
    • /
    • pp.326-331
    • /
    • 2012
  • Purpose: Length measurement from maxillary anterior teeth root tip to nasal floor is incorrect in panoramic radiography. Comparison of cone beam computed tomography (CBCT) and panoramic radiography should be helpful in determining the vertical length. Methods: Sixty nine patients were taken CBCT and panoramic radiography of the maxillary anterior. First measurement is length of parallel lines from the central incisor and lateral incisor root tip to nasal floor on CBCT. Second measurement is length of perpendicular lines from the central incisor and lateral incisor root tip to nasal floor on CBCT. Third measurement is length from the central incisor and lateral incisor root tip to nasal floor on panoramic radiographys. Results: In the first measurement of the maxillary central incisors, an average of $11.36{\pm}2.49$ mm in males and $10.49{\pm}2.17$ mm in females. In the second measurement of the maxillary central incisors, $10.41{\pm}2.42$ mm in males and $9.18{\pm}2.08$ mm in females. In the third measurement of the maxillary central incisors, $10.71{\pm}2.20$ mm in males and $9.27{\pm}2.10$ mm in females. In the first measurement of the maxillary lateral incisors, an average of $13.40{\pm}2.04$ mm in males and $11.96{\pm}2.20$ mm in females. In the second measurement of the maxillary lateral incisors, $11.25{\pm}1.82$ mm in males and $10.06{\pm}1.68$ mm in females. In the third measurement of the maxillary lateral incisors, $11.47{\pm}2.01$ mm in males and $10.13{\pm}1.70$ mm in females. Conclusion: The vertical length from root tip to nasal floor was longer in male than female (P>0.05). First measurement was longer than third measurement (P<0.05). This is the actual placement of the implant site measured on the vertical length than the length of the panorama means that there are a few more free. The first measurement was longer than 114% over the third measurement.

Reproducibility of the sella turcica landmark in three dimensions using a sella turcica-specific reference system

  • Pittayapat, Pisha;Jacobs, Reinhilde;Odri, Guillaume A.;Vasconcelos, Karla De Faria;Willems, Guy;Olszewski, Raphael
    • Imaging Science in Dentistry
    • /
    • 제45권1호
    • /
    • pp.15-22
    • /
    • 2015
  • Purpose: This study was performed to assess the reproducibility of identifying the sella turcica landmark in a three-dimensional (3D) model by using a new sella-specific landmark reference system. Materials and Methods: Thirty-two cone-beam computed tomographic scans (3D Accuitomo$^{(R)}$ 170, J. Morita, Kyoto, Japan) were retrospectively collected. The 3D data were exported into the Digital Imaging and Communications in Medicine standard and then imported into the Maxilim$^{(R)}$ software (Medicim NV, Sint-Niklaas, Belgium) to create 3D surface models. Five observers identified four osseous landmarks in order to create the reference frame and then identified two sella landmarks. The x, y, and z coordinates of each landmark were exported. The observations were repeated after four weeks. Statistical analysis was performed using the multiple paired t-test with Bonferroni correction (intraobserver precision: p<0.005, interobserver precision: p<0.0011). Results: The intraobserver mean precision of all landmarks was <1 mm. Significant differences were found when comparing the intraobserver precision of each observer (p<0.005). For the sella landmarks, the intraobserver mean precision ranged from $0.43{\pm}0.34mm$ to $0.51{\pm}0.46mm$. The intraobserver reproducibility was generally good. The overall interobserver mean precision was <1 mm. Significant differences between each pair of observers for all anatomical landmarks were found (p<0.0011). The interobserver reproducibility of sella landmarks was good, with >50% precision in locating the landmark within 1 mm. Conclusion: A newly developed reference system offers high precision and reproducibility for sella turcica identification in a 3D model without being based on two-dimensional images derived from 3D data.

CBCT를 이용한 유구치의 치근 및 근관의 형태학적 평가 (Assessment of Root and Root Canal Morphology of Human Primary Molars using CBCT)

  • 최유민;김선미;최남기
    • 대한소아치과학회지
    • /
    • 제47권1호
    • /
    • pp.25-35
    • /
    • 2020
  • 이 연구의 목적은 CBCT를 사용하여 유구치 치근 및 근관의 형태학적 특징을 평가하는 것이다. 과잉치 발거를 위해 전남대학교 치과병원 소아치과에 내원하여 CBCT를 촬영한 만 4 - 5세 환자 총 68명의 영상으로 연구를 진행하였다. 치근 흡수가 되지 않은 상악 제1유구치, 상악 제2유구치, 하악 제1유구치, 하악 제2유구치로 구분하여 분석하였다. 치근 및 근관의 수, 치근 및 근관의 길이와 각도 등의 다양한 변수들이 분석되었다. 상악 유구치는 모두 3개의 치근을 가졌고 원심 협측 치근과 구개 치근은 단일 근관을 가졌다. 한 치근에 2개의 근관이 있는 경우는 오직 상악 제2유구치의 근심 협측 치근에서 발견되었다. 하악 유구치는 대부분 근심과 원심 2개의 치근을 가졌다. 하악의 근심 치근은 대부분 2개의 근관을 가졌다. 치근의 길이와 관련하여, 상악의 구개 치근의 길이가 가장 긴 반면, 원심 협측 치근의 길이는 가장 짧은 것으로 밝혀졌다. 하악 유구치는 근심의 치근이 더 길었다. 상악 유구치에서는 구개 치근의 각도가 가장 컸으나 하악은 근심의 각도가 더 작았다. 상악 유구치의 치근 및 근관이 곡선형이 많은 반면 하악 유구치는 직선형을 더 많이 볼 수 있었다.

상악 제2유구치의 근심구개측 부가치근과 상악 제2소구치 사이의 연관성 (The Relationship between Additional Mesiopalatal Roots of Maxillary Primary Second Molars and Premolars)

  • 정우범;이고은;김미선;남옥형;최성철;김광철;이효설
    • 대한소아치과학회지
    • /
    • 제47권4호
    • /
    • pp.368-376
    • /
    • 2020
  • 상악 제2유구치는 일반적으로 3개의 치근을 갖는다. 하지만 드물게 근심구개측에 부가치근이 존재할 수 있다. 이 연구의 목적은 상악 제2유구치의 근심구개측 치근과 계승 영구치인 상악 제2유구치의 비정상적인 맹출 양상과의 연관성에 대해서 알아보는 것이다. 2010년 1월부터 2018년 12월까지 경희대학교 치과병원에 내원하여 전산화 단층 방사선 사진을 촬영한 3세부터 12세 어린이 916명을 대상으로 하였으며 744명의 어린이가 최종대상자로 선정되었다. 상악 제2유구치의 근심구개측 치근 발생률은 3.2%였으며 상악 제2소구치가 비정상적인 맹출 양상을 보이는 발생률은 19.2%였다. 상악 제2유구치의 근심구개측 치근이 존재할 때 상악 제2소구치가 비정상적인 맹출 양상을 보일 위험성이 상악 제2유구치가 근심구개측 치근이 없는 경우보다 약 13배 더 높았다. 상악 제2유구치에 근심구개측 치근이 존재한다면, 계승 영구치의 맹출 양상을 주의 깊게 관찰해야 하며 필요 시 치료가 개입되어야 한다.

EPID와 FSRT를 이용한 치료표적위치 검증에 관한 연구 (A Study on Treatment Target Position Verification by using Electronic Portal Imaging Device & Fractionated Stereotatic Radiotherapy)

  • 이동훈;권장우;박승우;김윤종;이동한;지영훈
    • 전자공학회논문지SC
    • /
    • 제46권3호
    • /
    • pp.44-51
    • /
    • 2009
  • 고 에너지 방사선을 이용하여 종양을 치료하는 과정 중 발생하는 오차를 확인하여 보다 정교한 치료를 시행하는 것은 매우 중요하다. 특히, 두경부 종양을 치료하기 위해 작은 조사면에 방사선을 집중 조사하는 정위 방사선 분할치료와 같은 특수 치료에서는 치료위치의 확인을 더욱 요구하고 있다. 작은 조사면에 고선량의 방사선을 표적체적에 집중 조사하는 정위 방사선 분할 치료법에서 치료 중심점의 정확도 검증은 매우 중요하므로 표적에 3mm 납 볼을 놓고 정위 방사선 분할 치료용 25mm 콘을 장착한 후 얻은 전자 포탈 영상으로부터 콘 원의 중심점과 볼 원의 중심점을 영상처리를 통해 서로 비교해 본 결과 1픽셀(0.76mm)의 정확도까지 얻을 수 있었다. 정위 방사선 분할 치료에 전자 포탈 영상 장치를 적용하여 치료위치오차 여부를 검증하였다. 이를 위해 첫 번째 정위 방사선 분할 치료 영상과 임의로 2mm 이동시킨 후 얻은 영상의 두개골 외곽선을 검출한 후 서로 비교해 본 결과 발생된 2mm 오차를 검증할 수 있었다. 본 논문에서는 개발된 비디오 기반 전자포탈영상장치와 정위 방사선 분할치료장치를 이용하여 실시간적으로 포탈영상을 획득할 수 있었으며 치료위치 검증을 통해 보다 정교한 방사선 치료를 할 수 있으리라 본다.

New method of assessing the relationship between buccal bone thickness and gingival thickness

  • Kim, Yun-Jeong;Park, Ji-Man;Kim, Sungtae;Koo, Ki-Tae;Seol, Yang-Jo;Lee, Yong-Moo;Rhyu, In-Chul;Ku, Young
    • Journal of Periodontal and Implant Science
    • /
    • 제46권6호
    • /
    • pp.372-381
    • /
    • 2016
  • Purpose: The aim of this study was to determine the relationship between buccal bone thickness and gingival thickness by means of a noninvasive and relatively accurate digital registration method. Methods: In 20 periodontally healthy subjects, cone-beam computed tomographic images and intraoral scanned files were obtained. Measurements of buccal bone thickness and gingival thickness at the central incisors, lateral incisors, and canines were performed at points 0-5 mm from the alveolar crest on the superimposed images. The Friedman test was used to compare buccal bone and gingival thickness for each depth between the 3 tooth types. Spearman's correlation coefficient was calculated to assess the correlation between buccal bone thickness and gingival thickness. Results: Of the central incisors, 77% of all sites had a buccal thickness of 0.5-1.0 mm, and 23% had a thickness of 1.0-1.5 mm. Of the lateral incisors, 71% of sites demonstrated a buccal bone thickness <1.0 mm, as did 63% of the canine sites. For gingival thickness, the proportion of sites <1.0 mm was 88%, 82%, and 91% for the central incisors, lateral incisors, and canines, respectively. Significant differences were observed in gingival thickness at the alveolar crest level (G0) between the central incisors and canines (P=0.032) and between the central incisors and lateral incisors (P=0.013). At 1 mm inferior to the alveolar crest, a difference was found between the central incisors and canines (P=0.025). The lateral incisors and canines showed a significant difference for buccal bone thickness 5 mm under the alveolar crest (P=0.025). Conclusions: The gingiva and buccal bone of the anterior maxillary teeth were found to be relatively thin (<1 mm) overall. A tendency was found for gingival thickness to increase and bone thickness to decrease toward the root apex. Differences were found between teeth at some positions, although the correlation between buccal bone thickness and soft tissue thickness was generally not significant.

Alveolar ridge preservation with an open-healing approach using single-layer or double-layer coverage with collagen membranes

  • Choi, Ho-Keun;Cho, Hag-Yeon;Lee, Sung-Jo;Cho, In-Woo;Shin, Hyun-Seung;Koo, Ki-Tae;Lim, Hyun-Chang;Park, Jung-Chul
    • Journal of Periodontal and Implant Science
    • /
    • 제47권6호
    • /
    • pp.372-380
    • /
    • 2017
  • Purpose: The aim of this prospective pilot study was to compare alveolar ridge preservation (ARP) procedures with open-healing approach using a single-layer and a double-layer coverage with collagen membranes using radiographic and clinical analyses. Methods: Eleven molars from 9 healthy patients requiring extraction of the maxillary or mandibular posterior teeth were included and allocated into 2 groups. After tooth extraction, deproteinized bovine bone mineral mixed with 10% collagen was grafted into the socket and covered either with a double-layer of resorbable non-cross-linked collagen membranes (DL group, n=6) or with a single-layer (SL group, n=5). Primary closure was not obtained. Cone-beam computed tomography images were taken immediately after the ARP procedure and after a healing period of 4 months before implant placement. Radiographic measurements were made of the width and height changes of the alveolar ridge. Results: All sites healed without any complications, and dental implants were placed at all operated sites with acceptable initial stability. The measurements showed that the reductions in width at the level 1 mm apical from the alveolar crest (including the bone graft) were $-1.7{\pm}0.5mm$ in the SL group and $-1.8{\pm}0.4mm$ in the DL group, and the horizontal changes in the other areas were also similar in the DL and SL groups. The reductions in height were also comparable between groups. Conclusions: Within the limitations of this study, single-layer and double-layer coverage with collagen membranes after ARP failed to show substantial differences in the preservation of horizontal or vertical dimensions or in clinical healing. Thus, both approaches seem to be suitable for open-healing ridge preservation procedures.

치과용 CBCT를 이용한 상악 정중치의 3차원 분석 및 정중치와 정중이개와의 관계분석 (Three Dimensional Analysis of Maxillary Mesiodens Using Dental CBCT and Relationship Between the Mesiodens and Diastema)

  • 강은주;최남기;김선미
    • 대한소아치과학회지
    • /
    • 제40권4호
    • /
    • pp.260-267
    • /
    • 2013
  • 본 연구는 Cone-beam computed tomography(CBCT)를 이용하여 상악 정중치의 크기, 형태, 위치 등의 3차원적 특성을 분석하고 이들이 영구치열에 미치는 영향에 대해 알아보고자 시행되었다. 2006년 6월부터 2012년 12월까지 내원하여 CBCT를 촬영한 환자 중 15세 이하의 환자, 191명을 대상으로 하였으며 이 중 정중이개를 보이는 43명을 대상으로 정중치의 크기, 위치와 정중이개량과의 상관관계를 분석하였다. 연구 결과, 정중치는 남성에서 약 3.9배 많이 발견되었고 7세에서 가장 많이 나타났다. 평균 길이는 13.0 mm, 폭경은 6.8 mm이였으며, 원추형이 59.2%로 가장 많았다. 정중치는 순측보다 구개측에 다수 존재하였고 수직적으로는 영구치의 치관부위에 근접해 있는 경우가 많았다. 정중치의 63.0%가 역위 형태였으며 정중치에 의해 유발된 병발증은 맹출지연이 39.0%, 정중이개 23.6%, 치아회전이 15.9%를 차지하였다. 이 중 정중이개량은 정중치의 크기와 중등도의 상관관계를 보였으며 정중치의 근원심 위치도 정중이개량과 통계적 상관관계를 보였다. 본 연구에서 시행한 정중치의 3차원 분석을 통해 정중치의 크기, 위치, 병발증의 발생분포를 파악할 수 있으며, 이 중 정중이개량은 정중치의 크기, 근원심 위치와 상관성이 있다는 것을 알 수 있었다.

Half-fan 모드를 이용한 방사선치료환자 위치교정을 위한 디지털영상 합성영상기술에 관한 예비연구 (Digital Tomosynthesis for Patient Alignment System Using Half-fan Mode CBCT Projection Images)

  • 박천주;박성호;김진성;한영이;주상규;신은혁;신정석;박희철;안용찬
    • 한국의학물리학회지:의학물리
    • /
    • 제21권4호
    • /
    • pp.360-366
    • /
    • 2010
  • 최근 정밀한 암 치료를 위해 방사선 치료기술이 강도변도 방사선치료, 영상유도 방사선치료 등의 눈부신 발전을 이루어 왔다. 2000년 이후로는 치료실에서 환자의 실제 치료위치를 정확히 파악하여 정밀한 치료를 가능하게 하는 영상 유도방사선 치료기술이 사용되고 있으며 가장 중요한 기술 중 하나가 방사선 치료 전에 다양한 방법의 의료 영상을 이용하여 환자의 치료 위치를 보정하는 것으로 가장 최근의 기술로는 선형가속기에 장착된 2차원 평면검출기를 이용한 콘빔CT (Cone Beam CT: CBCT)가 사용되고 있다. 본 연구에서는 기존의 CBCT의 "half fan" 조건에서 획득된 projection영상을 이용하여 360도 회전한 모든 영상이 아닌 제한된 각도에서 획득한 투사영상을 이용하여 환자의 해부학적 정보를 볼 수 있는 디지털 영상합성영상(Digital Tomosynthesis) 기술을 구현하였고 실제 위치교정을 위해 촬영된 환자 데이터를 이용하여 방사선 치료 환자 위치 교정을 위한 효용성을 검증하였다. 그 결과 동일 단층상에서의 해부학적 정보 표현에서 CBCT 영상과 비교하였을 때 유사성을 보였고 선량적인 측면에서 우월성을 나타냈다. 이러한 DTS의 장점을 극대화 하고 최적화가 이루어진다면 방사선 치료 위치 보정용으로 CBCT를 대체 할 수 있는 기술이 될 수 있을 것이라 기대한다.

Evaluation of the Geometric Accuracy of Anatomic Landmarks as Surrogates for Intrapulmonary Tumors in Image-guided Radiotherapy

  • Li, Hong-Sheng;Kong, Ling-Ling;Zhang, Jian;Li, Bao-Sheng;Chen, Jin-Hu;Zhu, Jian;Liu, Tong-Hai;Yin, Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권5호
    • /
    • pp.2393-2398
    • /
    • 2012
  • Objectives: The purpose of this study was to evaluate the geometric accuracy of thoracic anatomic landmarks as target surrogates of intrapulmonary tumors for manual rigid registration during image-guided radiotherapy (IGRT). Methods: Kilovolt cone-beam computed tomography (CBCT) images acquired during IGRT for 29 lung cancer patients with 33 tumors, including 16 central and 17 peripheral lesions, were analyzed. We selected the "vertebrae", "carina", and "large bronchi" as the candidate surrogates for central targets, and the "vertebrae", "carina", and "ribs" as the candidate surrogates for peripheral lesions. Three to six pairs of small identifiable markers were noted in the tumors for the planning CT and Day 1 CBCT. The accuracy of the candidate surrogates was evaluated by comparing the distances of the corresponding markers after manual rigid matching based on the "tumor" and a particular surrogate. Differences between the surrogates were assessed using 1-way analysis of variance and post hoc least-significant-difference tests. Results: For central targets, the residual errors increased in the following ascending order: "tumor", "bronchi", "carina", and "vertebrae"; there was a significant difference between "tumor" and "vertebrae" (p = 0.010). For peripheral diseases, the residual errors increased in the following ascending order: "tumor", "rib", "vertebrae", and "carina"; There was a significant difference between "tumor" and "carina" (p = 0.005). Conclusions: The "bronchi" and "carina" are the optimal surrogates for central lung targets, while "rib" and "vertebrae" are the optimal surrogates for peripheral lung targets for manual matching of online and planned tumors.