• Title/Summary/Keyword: Cone Angle

Search Result 375, Processing Time 0.026 seconds

Comparison of Gait Stability of using an Outdoor Rollator with Walking and using a Bassinet as Ambulatory Aid

  • Park, Min-Su;Park, Soo-Hee;Yang, Yeong-Ae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.2
    • /
    • pp.327-336
    • /
    • 2012
  • Objective: The purpose of this study is to find the problems of stability when people use the bassinet as an ambulatory aid for old people. Background: Many aged people use a bassinet as ambulatory aid. But the safety of using the bassinet as ambulatory aid has not been verified yet. Method: The 13 university-students who don't have musculoskeletal disorders volunteered to participate in this study. According to structural analysis of the both tools, we compared the structural stability of an outdoor rollator with the structural stability of a bassinet. And when the participants walked using both tools, the motions were captured and analysed. We measured the angle of shoulder joint and the angle of trunk from the ground when the participants were walking. And we found the distance from participants' pressure cone apex and greater trochanter. Results: Following the structural analysis, the bassinet has the lower structural stability than the outdoor rollator. When the people used the bassinet as ambulatory aid, the angle of the shoulder joint was bigger than to use the outdoor rollator. The angle of trunk wasn't different between the outdoor rollator and the bassinet. And distance from pressure cone apex to greater trochanter was far to use the bassinet than to use the outdoor rollator. Conclusion: Through the structure analysis and gait analysis of the bassinet and the outdoor rollator, we can be aware of that the bassinet has problem of stability. Therefore the people who use the bassinet as an ambulatory aid, especially supporting body weight, may be hurt due to the problems of stability. Application: This research can be used for developing a study of the ambulatory aid and preventing the accident when the aged people use the ambulatory aid.

A survey study on recognition of periapical radiography in dental hygiene students (치위생과 학생의 치근단 촬영법 인식에 관한 조사 연구)

  • Park, Il-Soon;Jung, Jung-Ock;Lee, Kyeong-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.5
    • /
    • pp.987-997
    • /
    • 2012
  • Objectives : This study was carried out in order to obtain basic data for students' efficient acquirement and instruction of radiography technology in the future by surveying dental hygiene students' recognition of periapical radiography. Methods : This study carried out a questionnaire survey targeting dental hygiene students from December 2009 to December 2010, and obtained the following results. Results : 1. As a result of examining recognition on periapical radiography, the bisecting angle technique was indicated to be averagely $3.84{\pm}0.566$ points. The paralleling technique was indicated to be $2.66{\pm}0.701$ points. 2. As a result of examining about problems given the bisecting angle technique, what had been most difficult given the bisecting angle technique was indicated to be the highest in cone positioning with 34.2%. The most difficulty given deciding on the X-ray vertical-angel irradiation direction was indicated to be the highest with 66.9% in adjusting the cone direction on the virtual bisector. 3. As a result of examining about problems given the paralleling technique, what had been most difficult in the process of the paralleling technique was indicated to be the highest with 56.7% in fixing the film immobilization device inside the mouth. Conclusions : Examining the above results, it is considered that there is a need of understanding morphological and anatomical structure inside the mouth in order to reduce the mistake rate given the periapical radiography, and that it is important to increase skill level by repetitively shooting several times with having enough time.

Analysis of Variations in Mechanical Properties of Soil by Tillage Operations (경운작업에 의한 토양 역학적 특성의 변이 특성)

  • Park, J.G.;Lee, K.S.;Cho, S.C.;Noh, K.M.;Chung, S.O.;Chang, Y.C.
    • Journal of Biosystems Engineering
    • /
    • v.32 no.4
    • /
    • pp.215-222
    • /
    • 2007
  • In the study, the cone index, the cohesion and the internal friction angle of soil were measured before and after tillage in order to suggest relative improvement in soil properties by comparing the two measured values before and after tillage. The tillage methods tested in the study were five combinations of plowing and rotovating; one plow tillage operation, one plow followed by one rotary, one plow followed by two rotary, one rotary without plow and two rotary without plow. The experiments were performed in a soil bin in Sunggyunkwan Univ. and in four selected test fields in Yeoju, Seodun-Dong, Suwon (especially, two different fields) and Chungju. In general, the internal friction angle and cohesion of soil increased with the increase of soil compaction. After applying the tillage operations, the internal friction angle reduced by 14 degree and the cohesion decreased up to about $2.2N/cm^2$ on the soil bin in comparison with those before tillage. The two values, however, reduced by 9 degree and up to about $1.0N/cm^2$ on the tested fields. The CIs for all the tillage operations on the soil bin and on 4 different test fields were decreased by 800 kPa in comparison with those before tillage. The best combination of tillage operations for decreasing the CIs of soil was one plow operation followed by one rotary. The CIs for one plow operation followed by two rotary were slightly higher than that for one plow operation followed by one rotary because one plow operation followed by two rotary crushed down the soil excessively, so that the porosity of soil decreased.

Spray Characteristics of Swirl-coaxial Injector According to the Recess Length and Injection Pressure Variation (리세스 길이 및 분사압력 변이에 따른 스월 동축형 인젝터의 분무특성)

  • Bae, Seong Hun;Kwon, Oh Chae;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.4
    • /
    • pp.68-76
    • /
    • 2016
  • This research is carried out for the performance evaluation of the injector that is one of the critical components of bipropellant-rocket-engine. Spray characteristics are investigated in detail according to the recess length and injection pressure on the swirl-coaxial-injector using gaseous methane and liquid oxygen as propellants. A visualization is conducted by the Schlieren photography that is composed of a light source, concave mirrors, knife, and high-speed-camera. A hollow-cone-shape is identified in the liquid spray that is spread only by inner injector and the spray angle is decreased due to the diminution of swirl strength in accordance with the increase of the length of injector orifice. When the injector sprays the liquid through the inner injector with the aid of gas through the outer injector, the spray angle in external mixing region tends to increase with rise of the recess length, while in internal mixing region, it is decreased. It is also confirmed that the same tendency of the spray angle with recess length appears irrespective of the injection pressure of liquid spray.

TECHNICAL ERRORS IN COMPLETE MOUTH RADIOGRAPHIC SURVEYS ACCORDING TO RADIOGRAPHIC TECHNIQUES AND FILM HOLDING METHODS (구내전악표준방사선사진 촬영시 촬영법과 필름유지법에 따른 촬영상의 실책)

  • Choi Karp-Shik;Byun Chong-Soo;Choi Soon-Chul
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.16 no.1
    • /
    • pp.103-112
    • /
    • 1986
  • The purpose of this study was to investigate the numbers and causes of retakes in 300 complete mouth radiographic surveys made by 75 senior dental students. According to radiographic techniques and film holding methods, they were divided into 4 groups: Group Ⅰ: Bisecting-angle technique with patient's fingers. Group Ⅱ: Bisecting-angle technique with Rinn Snap-A-Ray device. Group Ⅲ: Paralleling technique with Rinn XCP instrument (short cone) Group Ⅳ: Paralleling technique with Rinn XCP instrument (long cone) The most frequent cause of retakes, the most frequent tooth area examined, of retakes and average number of retakes per complete mouth survey were evaluated. The obtained results were as follows: Group Ⅰ: Incorrect film placement(47.8%), upper canine region, and 0.89 Group Ⅱ: Incorrect film placement (44.0%), upper molar region, and 1.12. Group Ⅲ: Incorrect film placement (79.2%), upper molar region, and 2.05 Group Ⅳ: Incorrect film placement (67.7%), upper molar region, and 1.69. The average number of retakes per complete mouth survey of paralleling technique (Group Ⅲ+Ⅳ) was higher than that of bisecting-angle technique (Group Ⅰ + Ⅱ) (p<0.01). There was no difference between Group Ⅰ and Group Ⅱ, and between Group Ⅲ and Group Ⅳ in the average number of retakes per complete mouth survey (p>0.05).

  • PDF

The Vertical Changes of Lip and Perioral Soft Tissue Following Orthognathic Surgery in Skeletal Class III Patients by a Cephalometric Analysis of Cone Beam Computed Tomography (Cone Beam Computed Tomography의 두부계측분석을 통한 골격성 제3급 부정교합 환자에서 악교정 수술 후 입술과 주위 연조직의 수직적 변화)

  • Lee, Jong-Min;Kang, Joo-Wan;Lee, Jong-Ho;Kim, Chang-Hyen;Park, Je Uk
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.5
    • /
    • pp.311-319
    • /
    • 2012
  • Purpose: The aim of this study is to evaluate the vertical changes of the lip and perioral soft tissue, following orthognathic surgery in skeletal class III patients by a cephalometric analysis of a cone beam computed tomography (CBCT). Methods: A total of 20 skeletal class III patients, who had bimaxillary surgery with Le Fort 1 osteotomy and bilateral sagittal split ramus osteotomy, were included in this study. The surgical plan for maxilla was posterosuperior impaction with the anterior nasal spine, as the rotation center. Further, the surgical plan for mandible was also posterosuperior movement. The soft tissue changes between lateral cephalogram and CBCT were compared. And the correlations between independent variables and dependent variables were evaluated. Results: There were no significant differences of the soft tissues changes between lateral cephalogram and CBCT. Upper lip philtrum length (SnLs), nasolabial angle increased and upper lip vermilion length (LsStms), lower lip length (StmiB'), lower lip vermilion length (StmiLi), lower lip philtrum length (LiB') and soft tissue lower facial height (SnMe') decreased after surgery. Change of SnLs (${\Delta}$SnLs) was influenced by vertical change of menton (${\Delta}$MeV), and change of LsStms (${\Delta}$LsStms) was influenced by upper lip thickness (ULT). Change of StmiLi' (${\Delta}$StmiLi') were influenced by preoperative overjet. Change of StmiB' (${\Delta}$StmiB') were influenced by preoperative overjet, vertical change of lower incisor (${\Delta}$L1V) and horizontal change of posterior nasal spine (${\Delta}$PNSH). Change of LiB' (${\Delta}$LiB') was influenced by ${\Delta}$L1V and ${\Delta}$PNSH. Change of SnMe' (${\Delta}$SnMe') was influenced by ${\Delta}$MeV, horizontal change of upper incisor (${\Delta}$U1H) and horizontal change of lower incisor (${\Delta}$L1H). ${\Delta}$Nasolabial angle was influenced by change of ULT (${\Delta}$ULT). Conclusion: Both soft tissues and hard tissues can be evaluated by CBCT. Posterosuperior rotation of maxillomandibular complex resulted in increase of upper lip philtrum length and nasolabial angle, while the upper lip vermilion length, lower lip philtrum length, lower lip vermilion length, and soft tissue lower facial height showed a decrease.

LASER-INDUCED IGNITION OF REACTIVE SOLIDS WITH ROUGH SURFACE

  • Jae-Ou Chae;Gregory N. Mokhin;Nam-Ki Kim
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.157-168
    • /
    • 1995
  • Ignition of a reactive solid with rough surface by constant heat flux is studied. The geometry of surface is represented by a protrusion in shape of cone of infinite length. Ignition time and ignition criterion versus apex angle are determined, with the use of heterogeneous model of ignition. To study the effect of geometry on ignition the results are compared with the known results for the one-dimensional ignition of the semi-infinite body. It is shown, that: a) ignition time depends strongly upon the apex angle and is proportional to the angle to the second power; b) ignition criterion and ignition temperature do not depend strongly on angle. The ignition delay and the energy required for the successful ignition are substantially reduced compared to the one-dimensional case.

  • PDF

An Experimental Study on Injection and Durability Characteristics of Common-rail Injector According to mixture Ratio of Bio-diesel (바이오 디젤 혼합비에 따른 커먼레일 인젝터의 분사 및 내구특성에 관한 실험 연구)

  • Im, Seok-Yeon;Kim, Tae-Bum;Yu, Sang-Seok
    • Journal of ILASS-Korea
    • /
    • v.16 no.1
    • /
    • pp.44-50
    • /
    • 2011
  • An object of this study is to understand the correlation of injection characteristics and injector dimensions according to biodiesel mixture. The Injection characteristics of different types of common-rail injectors are the number of nozzle holes (5~8), jet cone angle ($146^{\circ}{\sim}153^{\circ}$), hydraulic flow rate (830~900 ml/min) injection quantity and response time. Prior to characteristic experiment, the reference injector has been selected in 6 candidates injectors under the investigation of injected quantity according to the biodiesel mixture so that injector type can be determined. The injector is used for the characteristic experiment which varied the various operating conditions including pressure 23 MPa, 80 MPa, 160 MPa, changing in injection duration 0.16 ms~1.2 ms and even mixture ratio. The result shows that the nozzle hole number and cone angle influence the injection quantity much more than nozzle hole diameter at low injection pressure and the nozzle hole diameter at high injection pressure, post injection duration.

Modeling of Breakup and Spray of Co-axial Swirl Injector's Outer Orifice Installed LRE combustor (액체로켓엔진에 장착되는 동축 스월형 분사기의 외측 오리피스에서의 분무 및 분열 모사)

  • Moon, Yoon-Wan;Seol, Woo-Seok;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.186-190
    • /
    • 2006
  • This study was performed to investigate the characteristics of a co-axial swirl injector. Especially to predict the initial liquid sheet thickness and spray cone angle of an outer orifice a concept of effective area was introduced from hydraulic analysis. In addition, the parameters determining the characteristics of a co-axial swirl injector were re-defined around outer orifice. The calculated results-SMD, spray cone angle, and spray thickness agreed well with the test results qualitatively.

  • PDF