• Title/Summary/Keyword: Conductor temperature gradient

Search Result 5, Processing Time 0.02 seconds

Effect of Tension and Wind Velocity on Temperature of ACSR Overhead Conductor (장력과 풍속이 ACSR 가공송전선의 온도에 미치는 영향)

  • Kim Shang-Shu;Kim Byung-Geol;Lee Dong-Il;Min Byung-Uk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.5
    • /
    • pp.480-485
    • /
    • 2006
  • A research was undertaken on the thermal properties and behavior of the conductors in a controlled chamber, which was designed to implement the outdoor air temperature, heat and wind conditions With ACSR $410mm^2$ overhead conductors, we measured the maximum temperature of the conductors and the temperature gradient from the core to the surface regions as a function of current, tension, wind velocity and outdoor air temperature. This test also provided a comparative analysis between the measured temperature values of conductors in the controlled chamber and the theoretical calculations of ANSI/IEEE at normal condition. There was not much influence of tension on the conductor temperature. However, the compactness of conductor wires increased with an increase in tension, which eventually increased the coefficient of effective thermal conductivity and, accordingly the conductor temperature was reduced more or less.

Effect of Ambient Temperature and Current on Overhead Conductor (가공송전선의 열적거동과 전류 및 외기온도의 영향)

  • Kim Shang-Shu;Kim Byung-Geol;Hyun Suk-Kyu;Lee Dong-Il;Min Byung-Uk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.5
    • /
    • pp.486-491
    • /
    • 2006
  • A research was undertaken on the thermal properties and behavior of the conductors in a controlled chamber, which was designed to implement the outdoor air temperature, heat and wind conditions. With ACSR $410mm^2$ overhead conductors, we measured the maximum temperature of the conductors and the temperature gradient from the core to the surface regions as a function of current, tension, wind velocity and outdoor air temperature. This test also provided a comparative analysis between the measured temperature values of conductors in the controlled chamber and the theoretical calculations of ANSI/IEEE at normal condition.

Gradient YZO Buffer Deposition on RABiTS for Coated Conductor

  • Kim, T.H.;Kim, H.S.;Ko, R.K.;Song, K.J.;Lee, N.J.;Ha, D.W.;Ha, H.S.;Oh, S.S.;Pa, K.C.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.240-241
    • /
    • 2007
  • In general, high temperature superconducting coated conductors have intermediary buffers layer consisting of seed, diffusion barrier and cap layers. Simplification of the oxide materials buffer architecture in the fabrication of high temperature superconducting coated conductors is required because the deposition of multi-layers buffer architecture leads to a longer manufacturing time and a higher cost process of coated conductors. Thus, single buffer layer deposition seems to be important for practical coated conductor manufacturing process. In this study, a single gradient layered buffer deposition process of YZO for low cost coated conductors has been tried using DC reactive sputtering technique. About several thick YZO gradient single buffer layers deposited by DC co-sputtering process were found to act as a diffusion layer.

  • PDF

Study on Tension and Thermal Properties of Corrosive-fractured Steel Sleeve (강 슬리브 파단 직선 슬리브의 장력 및 열적 특성 분석 연구)

  • Ahn, Sang-Hyun;Kim, Byung-Geol;Kim, Sang-Shu;Sohn, Hong-Kwan;Kim, In-Pyo;Kim, Sung-Kyu
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.11
    • /
    • pp.1036-1041
    • /
    • 2008
  • According to previous report, aged sleeves of old transmission line showed several defaulted installation patterns, which was biased or corrosive-fractured of steel sleeve installed cases. These defects can cause serious accidents such as rapid increasing of sag or falling out of overhead conductor from sleeves. Consequently, the defects lead to the major power outage. Corrosion of steel sleeve is a typical defect by aging of sleeves. And it occupied almost 25 percent of investigated aged sleeves. This paper studied thermal properties and tension for ACSR conductor in case of fractured steel sleeve model by corrosion. The temperature distribution within overhead conductor has a specific gradient. Thermal properties of splice connectors(sleeve and clamp) showed normal behavior. However, mechanical properties were worse than normal sleeves. The detailed results were presented in the text.

HTS high gradient magnetic separator prototype

  • Diev, D.N.;Lepehin, V.M.;Makarenko, M.N.;Polyakov, A.V.;Shcherbakov, V.I.;Shutova, D.I.;Surin, M.I.;Tagunov, E. Ya.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.4
    • /
    • pp.1-5
    • /
    • 2018
  • A high gradient magnetic (HGM) separator prototype with the $2^{nd}$ generation high temperature superconducting (2G HTS) magnetic system operated in sub-cooled nitrogen is presently under development at NRC "Kurchatov Institute" (Moscow, Russia). The main goal of the project is an attempt to shift away from the complicated liquid helium cryostats towards simple cryocooler-based nitrogen cryogenics as much more convenient for HGM separators industrial applications. Using of commercial HTS tapes allows to get a sufficient level of magnetic fields and extraction forces with low energy consumption. The expected operational parameters of the device are 1.2-1.5 T in the empty operational gap and up to 3 T on the ferromagnetic filters. In this paper we briefly describe the design of the HTS rotary separator prototype with the horizontally oriented rotor axis and propose different types of ferromagnetic filters intended for weakly magnetic ores enrichment.