• Title/Summary/Keyword: Conductor length

Search Result 169, Processing Time 0.03 seconds

CPW Directional Couplers with Enhanced Directivity Via Center-Elimination of Backed Conductor (Backed Conductor의 Center-Elimination을 통한 향상된 방향성을 갖는 CPW 방향성 결합기의 설계)

  • 박정훈;이창언;최경민;신철재
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.12
    • /
    • pp.1321-1328
    • /
    • 2003
  • In this paper, we demonstrate that the directivity of the CPW(Coplanar Waveguide) directional coupler with finite-extent backed conductor is enhanced by eliminating center region of backed conductor appropriately. If the backed conductor is removed at center region of couplers, the couplers have two backed conductors. If effective odd mode dielectric constant is decreased at center region, the electrical length for odd mode is changed and phase velocity is same at the directional couplers. Hence, directivity is improved. The eliminated length is solved by an odd and even mode analysis. The designed moderate CPW directional coupler with the proposed compensation structure has excellent directivity and matching characteristic at center frequency in simulation and measurement.

Fabrication and the transportation properties of 1000A class multistrand conductor for HTS power cable (고온초전도 전력케이블용 1000A급 multistrand conductor의 제조 및 특성분석)

  • Park, S.C.;Yoo, J.M.;Ko, J.W.;Kim, H.D.;Kang, S.C.;Chung, H.S.
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.115-119
    • /
    • 2001
  • For the fabrication of HTS power cable, multifilamentary Bi-2223/Ag tapes have been prepared using the powder-in-tube (PIT) process. After final heat treatment, these tapes have $I_{c}$ value of 43A, and$ J_{c}$ value of $28,000A/\textrm{cm}^2$(77K, 0T). Prototype 1000A class multistrand conductor(length~1m) was fabricated using these tapes(length~300m). This multistrand conductor was impregnated with low-temperature epoxy. The transportation properties of prototype 1000A class multistrand conductor has been evaluated at 77K, and yielding a current capacity up to 1200A.A.A.

  • PDF

Wind-and-flip technique for the fabrication of a persistent mode superconductive magnet by using a coated conductor

  • Lee, Hee-Gyoun;Kim, Jae-Geun;Kim, Woo-Seok;Lee, Seung-Wook;Choi, Kyeong-Dal;Hong, Gye-Won;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.2
    • /
    • pp.7-10
    • /
    • 2007
  • Persistent mode HTS pancake coil has been fabricated using a coated conductor by a "wind-and-flip" method. A coated conductor with the length of 1.2 meters was divided at the center along the length. The sliced coated conductor was wound on a pair of bobbins with a diameter of around 4 cm and two pancake coils connected superconductively without a resistive joint were prepared. By flipping one of the pancake coils, the magnetic field generated by each coil is to be aligned to the same direction and generate meaningful magnetic field while the magnetic fields of two spit coils are canceled without flipping. Permanent current was induced by flowing current to the coil immersed in liquid nitrogen pool using a power supply. A magnetic field of 48.8 Gauss was generated when 20 A of current was flowing in the pancake coils. The "Wind and flip" method can be applied for the fabrication of a long solenoid magnet by winding a sliced coated conductor on a cylindrical bobbin. It is also introduced that the construction of multiple sets of pancake (or solenoid) coils is possible by a "wind-and-flip" method using a wide coated conductor.

A study on Subspan Oscillation Analysis of 6 Bundle Conductor Transmission lines (6도체방식 송전선로의 서브스판진동 해석에 관한 연구)

  • 이형권
    • Journal of KSNVE
    • /
    • v.7 no.5
    • /
    • pp.729-736
    • /
    • 1997
  • The subspan oscillation is the most important in bundled transmission lines, which can cause conductor damage and transmission line hardware failures. So it is necessary to analyze the subspan oscillation in details for transmission lines. This paper suggests the basic concept and theoretical analysis method of subspan oscillation for 6 bundle conductor transmission line, which considers wind speed, subspan length and conductor tension. Especially this paper uses a spacer damper model with clamp-arm flexibility and damping characteristics. Theoretical analysis results are proposed.

  • PDF

Breakdown Characteristics of Air in the Gap between Line Conductor and Plane Electrode in Case of Combustion Flame on the Plane Electrode (선도체 대 평면전극 갭에서 평면전극에 연소화염 존재시 대기의 절연파괴 특성)

  • Kim, In-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.4
    • /
    • pp.73-80
    • /
    • 2013
  • Breakdown characteristics of air in the vertical arrangement of line conductor and plane electrode in case of combustion flame on the plane electrode are examined by the application of AC. and DC voltages to the gap. In order to investigate the effect of paraffin flame on the breakdown characteristics of air, flashover voltages are measured according to the variation of the gap length and the horizontal distance between the flame and the line conductor. As the result of the experiment, flashover voltages are substantially lowered down to 29.8% in case of the AC voltage, and 16.1% in case of the negative DC voltage, when in the presence of the flame. from 100% when in the absence of flame. Flashover voltages of air in the range of smaller than 3㎝ at the horizontal distance are increased in the proportion of the gap length and the horizontal distance in case of both AC and negative DC voltages. But before the flashover occurs, the flame is extinguished by such corona wind that is produced from the line conductor when the gap length and the horizontal distance reach to a certain degree. The effect of relative air density and the phenomenon of thermal ionization are analysed as the reduction factors of flashover voltages, due to high temperature of the flame.

Calculation and Mitigation of Magnetic Field Produced by Straight Line-Conductor with Finite Length (유한장 직선도체에 의한 자계의 계산 및 감소대책)

  • Kang, Dae-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.57-67
    • /
    • 2011
  • Purpose of this study is to find the mitigation method of magnetic field by finite length multi-conductors such as indoor distribution lines and to be applicable to design of the distribution lines. For this purpose, exact formula about the components $B_x$, $B_y$, $B_z$ of magnetic field need in case of straight line-conductor with finite length forward any direction. In this study simple formula of the components were deduced and by using these formula magnetic fields for various models of line-configurations were calculated. And also a calculation method of induced currents in conductive shield was presented and using this method, programing of calculation is relatively easy and calculation time is short. The magnetic field after cancellation by these induced currents was calculated. All of calculations were performed by Matlab 7.0 programs. Through the calculation results it could be obtained followings for the mitigation of magnetic fields. The separation between conductors ought to be smaller than smaller as possible. In case of 3-phase, delta configuration is more effective than flat configuration. In case of 3-phase, unbalanced currents ought to be reduced as possible.. In case of more than two circuits of 3-phase, adequate locations of each phase-conductor such as rotating configuration of 3-phase conductors are more effective. The magnetic shielding effect of the conductive shielding sheet is very high.

Development of a 1.8T HTS Insert Coil for High Field Magnet (고자장 자석용 1.8T HTS insert 코일 개발)

  • Bae, Joon-Han;Seong, Ki-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1035-1038
    • /
    • 2007
  • We designed and manufactured a 1.8T high temperature superconducting(HTS) insert coil for a NMR magnet operated at 4.2 K. Suitable HTS superconductor and HTS coil were carefully designed and developed. We have selected multi-filamentary Bi2223 conductor fabricated by American Superconductor Corporation(AMSC). The selected conductor consists of Bi2223 filaments of 55, silver stabilizer and stainless steel reinforcement tapes. Therefore, it shows good hoop strength as well as compression tolerance. The conductor has a tape cross-section of 0.31mm x 4.8mm. the Bi2223 conductor shows large anisotropy of critical current. The critical current of conductor in magnetic field parallel to the flat surface are much higher than that in magnetic field perpendicular. The HTS coil has an inner diameter of 78 mm, an outer diameter of 127 mm and a coil length of 600 mm. In this paper, the detailed design, fabrication and test results on the HTS insert coil are presented.

Transmission Characteristics & Analysis of Ignition Voltage According to Its Conductor Length from the Ballast to the HID Lamp (HID램프와 안정기 사이의 전선 길이에 따른 이그니션 전압 전달특성 분석)

  • Bang, Sun-Bae;Kim, Chong-Min;Han, Woon-Ki;Im, Byeong-No;Jang, Mog-Soon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.3
    • /
    • pp.148-154
    • /
    • 2007
  • In this paper, characteristics of ignition voltage and current by wire length of HID(High Intensity Discharge) lamp circuit are analyzed. In the construction field, decision of the wire thickness for HID lamp circuit has the problems, and these are presented. Through transmit parameters, equivalent model of the ballast and HID lamp circuit was derived. The graph of voltage reduction about length between the ballast and the lamp is shown. The simulation of proposed model and experimental results are presented in order to validate the proposed method. The proposed model and graph can use to choose the proper length of wire between the ballast and the lamp in the field.

Calculation of electromagnetic field by electric power facilities in building (건축물내의 수전설비에 의한 전자파 자계의 계산)

  • Kang, Dae-Ha;Lee, Yuong-Sik;Lee, Jae-Hoon;Jo, Yong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1510-1511
    • /
    • 2007
  • In this study quantifying techniques of ELF magnetic fields arising from currunt carrying indoor-conductor are proposed. These techniques can be applied to line-conductor with finite length and any configuration. Since each component of magnetic field in rectangular axes system is seperated, the resultant magnetic field can be caculated for multi-conductor system through these techniques.

  • PDF

Operation Effectiveness Evaluation According to Conductor Transposition Adoption in Underground Power Cable Systems (지중송전케이블의 도체연가방식 채용시 효용성 평가)

  • Kim, June;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.5
    • /
    • pp.636-643
    • /
    • 2014
  • Length of most underground power cable in nation is not so long. Therefore it is operated without conductor transposition due to low unbalanced ratio. However, if cable length is long, line constant of each cable will be different. Different line constant can induce unbalanced voltage and current of sheath. Also it can induce several induced interference. This paper describes the operation effectiveness through steady and transient analysis on transposition and untransposition of cable conductor. Especially sheath current and induced voltage are analyzed and compared in case of transposition and untransposition. EMTP is used for modeling and analysis.