• Title/Summary/Keyword: Condensate

Search Result 190, Processing Time 0.027 seconds

Vibration Phenomena between Condensate Vertical Pump and Condenser Debris system in Power Plant (발전소 복수기 볼세정계통에 의한 입형펌프 진동과 대책)

  • Kim, Yeon-Whan;Goo, Jae-Rayng;Bae, Yong-Chae;Lee, Hyun;Lee, Young-Shin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1020-1025
    • /
    • 2001
  • Vertical canned pumps are usually applied in the power plant to transport fluids that the available suction pressure is low at the condensate system and the circulating-water system. The top of the motor driver is 5.5m above the base and the barrel and drop column extend even further below the ground. While this size and configuration may produce an efficient pumping system, it also introduces several dynamic problems which must be considered in order to obtain a reliable operation. The main problem is that the vibrational mode of the long flexible cantilever structure above the ground exist near the operational characteristics of the condensate debris system. This system's trouble has been showed at 2,086 hp condensate water loading pumps in a nuclear power plant.

  • PDF

Process Design and Economic Evaluation of Condensate Recycling Process for Steam Consumption Reduction (스팀 사용 저감을 위한 응축수 재활용 공정설계 및 경제성 평가)

  • Kim, Jinuk;Choi, Yeongryeol;Cho, Hyungtae;Kim, Junghwan
    • Applied Chemistry for Engineering
    • /
    • v.31 no.6
    • /
    • pp.660-667
    • /
    • 2020
  • This study focused on the epoxy resin production process, which uses the steam of 155 ℃ or higher as a heat source, and discards all condensate generated. A part of the process is operated at low temperatures of 70 ℃ or below, thus there are opportunities to reduce the steam consumption by recycling wasted condensate as a heat source for the low temperature section of process. In this study, we developed process models that can reduce steam by recovering waste heat through recycling condensate and conducted a case study to find an optimal condensate recycling system. Three different process designs were proposed and economic evaluations were performed by comparing annual capital costs and steam savings in each case. Finally, an annual steam consumption of the low-temperature section could be reduced by up to 67.6%, which could also bring an additional economic benefit of 522.1 million won/yr.

CFD Analysis to Suppress Condensate Water Generated in Gas Sampling System of HANARO (하나로 기체시료채취계통에서 생성된 응축수 억제를 위한 CFD 해석)

  • Cho, SungHwan;Lee, JongHyeon;Kim, DaeYoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2_spc
    • /
    • pp.327-336
    • /
    • 2020
  • The high-flux advanced neutron application reactor (HANARO) is a research reactor with thermal power of 30 MW applied in various research and development using neutrons generated from uranium fission chain reaction. A degasifier tank is installed in the ancillary facility of HANARO. This facility generates gas pollutants produced owing to internal environmental factors. The degasifier tank is designed to maintain the gas contaminants below acceptable levels and is monitored using an analyzer in the gas sampling panel. If condensate water is generated and flows into the analyzer of the gas sampling panel, corrosion occurs inside the analyzer's measurement chamber, which causes failure. Condensate water is generated because of the temperature difference between the degasifier tank and analyzer when the gas flows into the analyzer. A heating system is installed between the degasifier tank and gas sampling panel to suppress condensate water generation and effectively remove the condensate water inside the system. In this study, we investigated the efficiency of the heating system. In addition, the variations in the pipe temperature and the amount of average condensate water were modeled using a wall condensation model based on the changes in the fluid inlet temperature, outside air temperature, and heating cable-setting temperature.

Dynamics of a Bose-Einstein Condensate on Changing Speeds of an Atomchip Trap Potential

  • Kim, Seung Jin;Noh, Jae June;Kim, Min Seok;Lee, Jin Seung;Yu, Hoon;Kim, Jung Bog
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.6
    • /
    • pp.633-638
    • /
    • 2014
  • We report experimental behaviors of condensed $^{87}Rb$ atoms responding to changes in the trap potential of the atomchip. The two-types of adiabatic and non-adiabatic overall changes were implemented by changing the ramp-down speed of the chip-wire current, which can dominantly modify the one-axis magnetic field gradient. Under the adiabatic process, a pure condensate stayed in the initial spin state and collectively oscillated with both monopole and dipole modes, while an atomic cloud above the critical temperature exhibited sound waves in a dense ultracold gas. On the other hand, Bose-Einstein condensate atoms with non-adiabatic perturbation were split into spatially different positions by spin states through spin-flip. We investigated the split ratio among spin states depending on final evaporation frequency. Potential changes, of course, cause collective oscillations regardless of the changing process.

Evaluation the Impact of Installing a Isolation Valve on Condensate System of Nuclear Power Plan (원자력발전소 복수기 수실 차단밸브 설치 영향 평가)

  • Lee, Sun-Ki
    • Journal of Industrial Convergence
    • /
    • v.18 no.4
    • /
    • pp.15-21
    • /
    • 2020
  • Because there are no isolation valves in condensate system of nuclear power plants, circulating water pump was shutdown for the condenser repair. When circulating water pump was shutdown, power plant output decreased about 45%. These output decreasing can minimize by establishing isolation valves. In this paper, evaluated effect to flow conditions change of condensate system, structural integrity of system, condenser pressure of in case of establish isolation valves to condensate system. Results of the evaluation, the flow rate due to the installation of the isolation valve decreased 0.3% when the valve was fully opened and 4.5% when fully closed. In addition, it was found that the vacuum degree of the condenser decreased with decreasing flow rate, but the integrity of the system was maintained.

A Fundamental Study on Development of a Rotating Horizontal Heat Pipe (회전식 수평 Heat Pipe의 개발에 관한 기초 연구)

  • 임광빈;이진성
    • Journal of Energy Engineering
    • /
    • v.8 no.2
    • /
    • pp.325-332
    • /
    • 1999
  • When a rotating heat pipe is in operation, liquid condensate returns from the condenser to the evaporator along the inside surface by both components of gravitational and centrifugal forces. It was known that its performance was largely dependent on how to increase the flow rates of condensate and keep the condensate film thickness as thin as possible. Most of research works were focussed on this goal, and various inner wall structures such as tapered wall, stepped wall or coil inserted pipe etc. were developed. In the present study, a stepped wall structure with 3 internal grooves in the condenser and adiabatic zone was examined. For this system, the condensate would flow down to the evaporator through the grooves, resulting a reduced film thickness over the condenser surface. Experimental data showed an enhancement of heat transfer coefficient in the condenser zone. An analytical solution to the condensate film thickness showed that the analytically calculated values of heat transfer coefficient were considerably higher than the experimental data.

  • PDF

Effect of Various Superplasticizers on the Hydration of Cement Paste (시멘트페이스트 수화 반응에 미치는 고유동화제의 영향성에 관한 연구)

  • Shin Jin-Yong;Kim Jae-Young;Hong Ji-Sook;Suh Jeong-Kwon;Lee Young-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.1019-1024
    • /
    • 2005
  • To research effects of various chemical superplasticizers(Lignosulfonic acid, Naphthalene sulfonated formaldehyde condensate, melamine sulfonated formaldehyde condensate, and Polycarboxylate) on the hydration of cement, experiments involving XRD, SEM, and DSC have been analysed with cement paste specimens. Regardless of types and dosages of superplasticizers, hydration reaction of specimen applied superplasticizer was delayed to 3 day, but then it showed similarity to plain which don't add superplasticizer. Moreover, the hydrating rate of cement paste was retarded as dosage of superplasticizer was increased. Also, kinetics related with hydrate of cement paste was slow in order of lignosulfonic acid, polycarboxylate, melamine and naphthalene sulfonated formaldehyde condensate. Nevertheless, when all kinds of chemical admixtures were used, morphologies of these hydrates were denser and more uniform than those of plain.

Examination on High Vibration and Branch Vent Pipe's Failure of Complex Piping System Suppling Condensate-Water in Power Site (발전소 복수 공급 배관계의 고진동과 분기 배기배관의 절손 규명)

  • Kim, Yeon-Whan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.380-384
    • /
    • 2010
  • A disturbance flow at piping bands and discontinuous regions such as a valve, a header has a intense broadband internal pressure field and a sound field which are propagated through the piping system The fields becomes the source of a vibration of this piping system. Intense broadband disturbance flow at a discontinuous region such as elbows, valves or headers generates an acoustical pulsation. The pulsation becomes the source of structural vibration at the piping system. If it coincides with the natural frequency of the pipe system, excessive vibration results. High-level vibration due to the pressure pulsation affects the reliability of the plant piping system. This paper discusses the high vibration and the branch vent pipe's failure of condensate-water supply piping system due to the effect of acoustical pulsations by flow turbulence from the flow control valves of globe type in a power site.

  • PDF

The improvement of the efficiency of power plant by the reformation of steam line in the return system (화력발전소에서 응축수 회수계통의 증기배관 개선에 의한 발전시스템의 효율 향상)

  • Kwon, Y.S.;Suh, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.867-871
    • /
    • 2001
  • The main reason for reviewing the condensate water return system in the auxiliary steam system is to obtain the thermal high efficiency of the power plant and thus save the fossil energy in power plant. This study intends to analyze the thermal efficiency of the power plant and predict the increasing in the generator output by the return system reformation of auxiliary steam line in the thermal power plant.

  • PDF

A Case Study on High Vibration in a Condensate Pump for Combined Cycle Power Plants (복합 화력 Condensate Pump 의 고진동 사례 분석 및 대책)

  • 최성필;류석주;하현천
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.510-513
    • /
    • 2001
  • Several kinds of vibration problems have been frequently encountered in industrial vertical pumps in spite of their widespread use for long time. In fact, vibration problems of the vertical pumps are so complicated and difficult with compared to those of the horizontally mounted pumps that more careful attention should be taken for solving the vibration problems. This paper introduces a case study experienced from troubleshooting for excessive vibration occurred in a vertical-type condensate pump for combined cycle power plants. Subsynchronous whirl vibration was caused by the instability of the guide bearing whose lubricant is water. A newly modified guide bearing has solved the vibration problem, which should be the best countermeasure.

  • PDF