• 제목/요약/키워드: Concrete-filled

검색결과 988건 처리시간 0.025초

콘크리트충전 강관기둥의 응력-변형도 관계에 관한 실험적 연구 (An Experimental Study on the Stress-Strain Relation of Concrete-Filled Steel Tubes)

  • 한병찬;임경택;엄철환;연길환;윤석천;정수영
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.210-214
    • /
    • 1995
  • Research on concrete-filled steel columns has been conducted. It is also well known that the load and deformation capacity of concrete-filled steel columns are considerable larger than those of widely used reinforced concrete columns and steel encased concrete columns because the concrete core in the steel is confined laterally by the steel. But, most of these works focused on columns with strength enhancement by the confinement effect, so that no local buckling prevented by the concrete. columns because the concrete core in the steel is confined laterally by the steel. But, most of these works focused on columns with strength enhancement by the confinement effect, so that no local buckling prevented by the concrete. This paper, therefore, presents on the stress-strain relation of a concrete filled rectangular steel tube under axial compression. As the results, the axial load verse average axial strain relationship of concrete-filled rectangular steel columns were very stable. The small B/t ratios in concrete-filled rectangular steel columns aren't affected prevention of local buckling but strength enhancement by confinement effect.

  • PDF

고성능 콘크리트를 충전한 각형강관 기둥의 구조적 거동 특성에 관한 연구 -재하조건별 거동특성- (A study on the Properties for Structural Behavior of High-Performance Concrete Filled Square Steel Tube Columns -The Behavior Properties by Loading Conditions-)

  • 박정민;이승조;김화중
    • 한국강구조학회 논문집
    • /
    • 제10권2호통권35호
    • /
    • pp.177-186
    • /
    • 1998
  • 콘크리트 충전 강관 기둥은 동일 단면의 비충전 강관 기둥에 비해 압축 내력이 우수하며 충전 콘크리트에 의한 강성의 향상, 국부좌굴 보강 효과에 의한 인성의 향상 등과 같은 구조적으로 우수한 점이 많다. 그러나. 강관과 충전 콘크리트의 상호작용 효과, 응력 분담율, 콘크리트의 파괴 양상 등에 대해서는 불분명한 점들이 많다. 본 연구는 일련의 실험을 통하여 고강도 콘크리트 충전 강관 기둥에 대해 재하 조건에 따른 구조적인 거동 특성에 대해 고찰하였다. 특히, 본 연구에서는 재하조건에 따른 강관과 콘크리트의 응력 분담율, 충전 콘크리트의 파괴 양상등에 대해 조사 하였다.

  • PDF

콘크리트 충전 원형 및 각형 합성 강관 기둥의 압축 거동에 관한 실험적 연구 (An Experimental Study on the Compression Behavior of the Circular and Square Tubular Steel Pipe filled with Concrete)

  • 박강근
    • 한국공간구조학회논문집
    • /
    • 제6권1호
    • /
    • pp.55-63
    • /
    • 2006
  • 본 논문은 콘크리트 충전 원형 및 각형 합성 강관을 기둥부재로서의 적합성 및 적용성을 위한 연구로 두개의 강관을 합성한 콘크리트 충전 강관 기둥의 축압축 좌굴내력 및 변형형상에 대한 실험적 연구이다. 강관 기둥에 대한 연구는 콘크리트 충전 원형 강관 기둥, 콘크리트 충전 각형 강관 기둥, 콘크리트 충전 합성 강관 기둥으로 분류하여 실험을 수행하였다.

  • PDF

신형식 거더의 고강도 콘크리트 적용 시 비선형 거동 분석 (Non-linear Behavior of New Type Girder Filled by High-Strength Concrete)

  • 최성우;이학;공정식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.217-220
    • /
    • 2008
  • 구조물의 시공에 있어 더욱 경제적이고 안정적인 결과를 얻기 위해 최근 전 세계적으로 고성능 콘크리트와 복합재료에 관한 연구가 활발히 이루어지고 있다. 그 중 하나로 대구경의 강관 내부를 콘크리트계 재료로 충전하여 충전재간의 상호 구속효과(Confinement effect)로 인해 부재의 변형성능과 강성 및 내력을 향상시키는 콘크리트 충전 강관구조(Concrete Filled Steel Tubular Structure, CFT구조)에 아치구조 효과와 강선 등을 이용한 프리스트레스 구조를 도입하여, 구조적, 경제적 효율성을 극대화 시킨 새로운 형식의 거더인 CFTA 거더(Concrete Filled and Tied Steel Tubular Arch 거더)가 있다. 본 연구에서는 구조해석 프로그램인 ABAQUS 6.5-1을 사용하여 CFTA 거더에 일반 콘크리트와 여러 강도의 고강도 콘크리트를 충전한 모델의 비선형 거동을 분석하고 각각의 결과를 비교 분석하였다.

  • PDF

Fire resistance of high strength fiber reinforced concrete filled box columns

  • Tang, Chao-Wei
    • Steel and Composite Structures
    • /
    • 제23권5호
    • /
    • pp.611-621
    • /
    • 2017
  • This paper presents an investigation on the fire resistance of high strength fiber reinforced concrete filled box columns (CFBCs) under combined temperature and loading. Two groups of full-size specimens were fabricated. The control group was a steel box filled with high-strength concrete (HSC), while the experimental group consisted of a steel box filled with high strength fiber concrete (HFC) and two steel boxes filled with fiber reinforced concrete. Prior to fire test, a constant compressive load (i.e., load level for fire design) was applied to the column specimens. Thermal load was then applied on the column specimens in form of ISO 834 standard fire curve in a large-scale laboratory furnace until the set experiment termination condition was reached. The test results show that filling fiber concrete can improve the fire resistance of CFBC. Moreover, the configuration of longitudinal reinforcements and transverse stirrups can significantly improve the fire resistance of CFBCs.

Prediction of ultimate moment anchorage capacity of concrete filled steel box footing

  • Bashir, Muhammad Aun;Furuuchi, Hitoshi;Ueda, Tamon;Bashir, M. Nauman
    • Steel and Composite Structures
    • /
    • 제15권6호
    • /
    • pp.645-658
    • /
    • 2013
  • The objective of the study is to predict the moment anchorage capacity of the concrete filled steel box (CFSB) as footing by using the 3D finite element program CAMUI developed by authors' laboratory. The steel box is filled with concrete and concrete filled steel tube (CFT) column is inserted in the box. Numerical simulation of the experimental specimens was carried out after introducing the new constitutive model for post peak behavior of concrete in compression under confinement. The experimental program was conducted to verify the reliability of the simulation results by the FE program. The simulated peak loads agree reasonably with the experimental ones and was controlled by concrete crushing near the column. After confirming the reliability of the FEM simulation, effects of different parameters on the moment anchorage capacity of concrete filled steel box footing were clarified by conducting numerically parametric study.

팽창 콘크리트를 충전한 강관충전 콘크리트의 물성에 관한 연구 (A Study on Properties of CFT filled with Expansion Concrete)

  • 박춘영;이진성;송종목;김효열;강병희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.117-120
    • /
    • 2008
  • The Purpose of this is properties of CFT filled with expansion concrete. CFT(concrete filled steel tube) is the structure that circle shape steel column filled with concrete. 3 kinds of expansive additives and variation of replacement rate. we changed expansive additive from 0%, 10%, 20%, 30% of ratio of addition rate are selected for this experiment. Merits of CFT are concrete internal force rising influenced by steel shape restriction, reinforcing the local buckling, excellent resistance to transformation. Generally, High rise building using CFT utilize the high strength and fluidity concrete for packing the tube inside. As the result a steel tube charged expensive concrete has stiffness 1.5times more than a steel tube not charged concrete. Increase of resisting power about compressive stress by binding expansion of expansive concrete affects strength increase and softness.

  • PDF

중심축압(中心軸壓)을 받는 콘크리트충전(充塡) 각형강관(角形鋼管)기둥의 내력(耐力)에 관한 실험적(實驗的) 연구(硏究) (Experimental Study on Compressive Strength of Centrally Loaded Concrete Filled Square Tubular Steel Columns)

  • 김종성;오윤태;권영환
    • 한국강구조학회 논문집
    • /
    • 제8권4호통권29호
    • /
    • pp.59-76
    • /
    • 1996
  • Concrete filled steel tube column has a large load carrying capacity through its steel and concrete interaction which makes it useful in construction. However, it has not been used often in a practical construction field. This is partly due to the non-destructive inspection method for concrete filling which has yet to be established. Furthermore, there are the lack of test data and a practical method in evaluating the ultimate load carrying capacity of concrete filled steel tube column. This paper will attempt to predict the ultimate strength of short concrete filled square tubular steel columns through conducting several tests. To accumulate the new test data on concrete filled steel tube columns, a total of 42 specimens of steel tubular columns were monotonically tested under concentric axial force, having the slenderness ratio(${\lambda}=10,\;15,\;20$), width-thickness ratio(d/t=25.0, 33.3) and concrete strengths($F_{c}=210,\;240,\;270kg/cm^{2}$). The hollow sections and concrete filled steel columns were compared to check the lateral confinded effects by steel tube. Through these test results, we propose a coefficient k=3.64 for the strength evaluation formula(10) of concrte filled tubular steel short columns.

  • PDF

콘크리트강도 및 단면특성에 따른 콘크리트 충전강관(CFT) 기둥의 극한강도 분포에 관한 실험적 연구 (An Experimental Study on Distribution of Ultimate Strength of Concrete-Filled Steel Tube Columns according to Concrete Strength and Section Properties Ratio)

  • 장갑철;장경호
    • 한국공간구조학회논문집
    • /
    • 제8권5호
    • /
    • pp.59-65
    • /
    • 2008
  • 최근, 교량교각과 같은 기둥구조물의 사용성능을 향상시킴과 동시에 복잡한 도심지 내 효율적 공간활용을 위해 콘크리트 충전강관(CFT: concrete-filled steel tube)의 적용이 점차 증가하고 있다. 이러한 기둥구조물의 정확한 설계를 위해서는 재료 및 기하학적 특성에 따른 콘크리트 충전강관 기둥의 거동에 관한 실험적 연구가 요구된다. 이에 본 연구에서는 압축강도실험을 통하여 외경-두께비 (D/t) 및 강재-콘크리트 단면적비 (As/Ac)에 따른 콘크리트 충전강관 기둥의 극한강도 분포특성에 대해 명확히 파악하였다. 또한 콘크리트 배합강도에 따른 콘크리트 충전강관 기둥의 극한강도 분포특성을 실험을 통하여 명확히 파악하였다. 실험결과의 고찰을 통하여 압축하중을 받는 콘크리트 충전강관 기둥의 극한강도는 콘크리트 강도보다 강과의 단면특성에 주로 의존함을 알 수 있었다.

  • PDF

Experimental behavior of circular flyash-concrete-filled steel tubular stub columns

  • Zhang, Yang;Fu, Guang-Yuan;Yu, Chen-Jiang;Chen, Bing;Zhao, She-Xu;Li, Si-Ping
    • Steel and Composite Structures
    • /
    • 제22권4호
    • /
    • pp.821-835
    • /
    • 2016
  • The paper presents an experimental study of the structural behavior of circular flyash-concrete-filled steel tubular stub columns under axial compressive loads. In this study, 90% and 100% by weight of the cement in the concrete core was replaced with flyash. Twenty-seven specimens were tested to study the influence of flyash content, wall thickness of the steel tube, and curing age on the ultimate capacity and confinement effect. The experimental results were compared with the design values calculated using AISC-LRFD (1999), ACI (1999), AIJ (1997) and Eurocode 4 (1994). From the experimental study, it was determined that the confinement effect of circular steel tubes filled with high content flyash concrete was better than that of specimens filled with ordinary Portland cement concrete. The 5.88-mm-thick steel tube filled with 100% flyash concrete was equivalent in strength to a steel tube filled with C30 concrete at 28 days.