• Title/Summary/Keyword: Concordance measure

Search Result 22, Processing Time 0.02 seconds

Study of Concordance Rate to Measure Symptoms in Interanl Researchers (중풍변증 진료기록부 및 변증지표 측정에 관한 내부연구자간 일치도 연구)

  • Kang, Byung-Kab;Go, Ho-Yeon;Kim, Joong-Kil;Kim, Bo-Young;Ko, Mi-Mi;Kang, Kyung-Won;Yu, Byeong-Chan;Seol, In-Chan;Lee, In;Jo, Hyun-Kyung;Choi, Sun-Mi
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.20 no.6
    • /
    • pp.1728-1731
    • /
    • 2006
  • To develop the Korean Standard Differentiation of the Symptoms and sings, We investigate concordance rate of symptoms between Korean Medicine Doctors. Two Korean medicine doctor surveyed symptoms with the Korean Standard Differentiation of the symptoms and sings for the Stroke(KSDS) case report form in stroke patients within 1 month of onset. The concordance rate of inspection, auscultation and olfaction, inquiry, and pulse feeling and palpitation are respectively 0.79, 0.90, 0.91,0.80. The study of inspection, pulse feeling and palpitation will be continued to evaluate concordance rate.

A Study on the Comovement of Industry Default (산업 부도의 동조화 현상 연구)

  • Jeon, Haehyun;Kim, So-Yeun;Kim, Changki
    • The Korean Journal of Applied Statistics
    • /
    • v.28 no.6
    • /
    • pp.1289-1312
    • /
    • 2015
  • This paper studies the comovement of industry defaults among listed companies. Rank correlation coefficients of Spearman's ${\rho}$ and Kendall's ${\tau}$ measure the concordance of default. These non-parametric coefficients do not require distributional assumptions and are easily used even with less data and extreme values. This study predicts a future financial crisis by looking at the comovement of industry defaults. We expect our analyses will aid market participants (including company executives) in making investment or risk management decisions.

Measuring Industry Greening Indices for Korean high priority green technologies by technology-industry concordance analysis (27대 중점녹색기술의 기술산업연계구조분석을 통한 산업녹색도 지수 연구)

  • Coh, Byoung-Youl
    • Journal of Technology Innovation
    • /
    • v.18 no.2
    • /
    • pp.121-145
    • /
    • 2010
  • This study relates to measure impact of green technology on industry sector by uses of industry greening indices. For this study, we performed patent trend analysis, technology-industry concordance analysis, and designed some industry greening indices. Through the results of this research, we found out the impact of Korean high priority green technologies on respective industries, and consequently identified which industries play an important role in the era of green innovation. IT related industries would catch somewhat weak attention in green technology policy, though they manufacture and use plenty of patents at present. Meanwhile, Energy related industry, such as battery industry would catch strong attention in green innovation, showed very high value of industry greening indices. In order to design proper R&D strategy for green technologies, understanding industry and market structure that can adapt and promote green technology innovation is important. In this context, this study could be an effective and systematic tool for assisting green innovation policy. Also, these indices developed are not limited to the case of green technology, other technologies can be used universally as a input for analysis.

  • PDF

Comparison of three types of analyzers for urine protein-to-creatinine ratios in dogs

  • Ji, Sumin;Yang, Yeseul;Jeong, Yeji;Hwang, Sung-Hyun;Kim, Myung-Chul;Kim, Yongbaek
    • Journal of Veterinary Science
    • /
    • v.22 no.1
    • /
    • pp.14.1-14.11
    • /
    • 2021
  • Background: Quantitation of urine protein is important in dogs with chronic kidney disease. Various analyzers are used to measure urine protein-to-creatinine ratios (UPCR). Objectives: This study aimed to compare the UPCR obtained by three types of analyzers (automated wet chemistry analyzer, in-house dry chemistry analyzer, and dipstick reading device) and investigate whether the differences could affect clinical decision process. Methods: Urine samples were collected from 115 dogs. UPCR values were obtained using three analyzers. Bland-Altman and Passing Bablok tests were used to analyze agreement between the UPCR values. Urine samples were classified as normal or proteinuria based on the UPCR values obtained by each analyzer and concordance in the classification evaluated with Cohen's kappa coefficient. Results: Passing and Bablok regression showed that there were proportional as well as constant difference between UPCR values obtained by a dipstick reading device and those obtained by the other analyzers. The concordance in the classification of proteinuria was very high (κ = 0.82) between the automated wet chemistry analyzer and in-house dry chemistry analyzer, while the dipstick reading device showed moderate concordance with the automated wet chemistry analyzer (κ = 0.52) and in-house dry chemistry analyzer (κ = 0.53). Conclusions: Although the urine dipstick test is simple and a widely used point-of-care test, our results indicate that UPCR values obtained by the dipstick test are not appropriate for clinical use. Inter-instrumental variability may affect clinical decision process based on UPCR values and should be emphasized in veterinary practice.

A Concordance Study of the Preprocessing Orders in Microarray Data (마이크로어레이 자료의 사전 처리 순서에 따른 검색의 일치도 분석)

  • Kim, Sang-Cheol;Lee, Jae-Hwi;Kim, Byung-Soo
    • The Korean Journal of Applied Statistics
    • /
    • v.22 no.3
    • /
    • pp.585-594
    • /
    • 2009
  • Researchers of microarray experiment transpose processed images of raw data to possible data of statistical analysis: it is preprocessing. Preprocessing of microarray has image filtering, imputation and normalization. There have been studied about several different methods of normalization and imputation, but there was not further study on the order of the procedures. We have no further study about which things put first on our procedure between normalization and imputation. This study is about the identification of differentially expressed genes(DEG) on the order of the preprocessing steps using two-dye cDNA microarray in colon cancer and gastric cancer. That is, we check for compare which combination of imputation and normalization steps can detect the DEG. We used imputation methods(K-nearly neighbor, Baysian principle comparison analysis) and normalization methods(global, within-print tip group, variance stabilization). Therefore, preprocessing steps have 12 methods. We identified concordance measure of DEG using the datasets to which the 12 different preprocessing orders were applied. When we applied preprocessing using variance stabilization of normalization method, there was a little variance in a sensitive way for detecting DEG.

A Pilot Study of Evaluating the Reliability and Validity of Pattern Identification Tool for Insomnia and Analyzing Correlation with Psychological Tests (불면증 변증도구 신뢰도와 타당도 평가 및 심리검사와의 상관성에 대한 초기연구)

  • Jeong, Jin-Hyung;Lee, Ji-Yoon;Kim, Ju-Yeon;Kim, Si-Yeon;Kang, Wee-Chang;Lim, Jung Hwa;Kim, Bo Kyung;Jung, In Chul
    • Journal of Oriental Neuropsychiatry
    • /
    • v.31 no.1
    • /
    • pp.1-12
    • /
    • 2020
  • Objectives: The purpose of this study was to evaluate the reliability and validity of the instrument on pattern identification for insomnia (PIT-Insomnia) and verify the correlation between PIT-Insomnia and psychological tests. Methods: Two evaluators examined the pattern identification of the participants who met insomnia disorder diagnostic criteria of the Diagnostic and Statistical Manual of Mental Disorder, Fifth Edition (DSM-5) and took the Insomnia Severity Index (ISI) score over 15 once manually and twice using the PIT-Insomnia to measure the inter-rater and test-retest reliability. We also conducted the following surveys: the Pittsburgh Sleep Quality Index (PSQI), the Korean version of Beck's depression inventory (K-BDI), the Korean version of the State-Trait Anxiety Inventory (STAI-K), the Korean Symptom checklist-95 (KSCL-95), and the EuroQol-5 dimension (EQ-5D), to measure concurrent validity and correlation between the PTI-Insomnia and psychological tests. Results: 1. The test-retest reliability analysis of the pattern identification results showed moderate agreement, and test-retest reliability analysis of each pattern identification score showed agreements from poor to moderate. 2. The inter-rater reliability analysis of the pattern identification results via manual showed slight agreement, when analysis was performed with calibration, the inter-rater reliability analysis of the pattern identification results via manual showed fair agreement. 3. The concordance analysis between results via manual and the PIT-Insomnia showed poor agreement, when the analysis was performed with calibration, concordance analysis showed fair agreement. 4. The concordance analysis between the PIT-Insomnia and the PSQI showed positive linear correlation. 5. The concordance analysis between the PIT-Insomnia and the PSQI, K-BDI, STAI-K, KSCL-95, and EQ-5D showed that non-interaction between the heart and kidney have positive linear correlation with the K-BDI, anxiety item of KSCL-95, dual deficiency of the heart-spleen have positive linear correlation with somatization item of KSCL-95, paranoia item of KSCL-95, heart deficiency with timidity have positive linear correlation with stress vulnerability item of KSCL-95, parania item of KSCL-95, phlegm-fire harassing the heart have positive linear correlation with K-BDI, paranoia item of KSCL-95, depressed liver qi transforming into fire have positive linear correlation with the anxiety item of KSCL-95, parania item of KSCL-95, all pattern identification have negative linear correlation with EQ-5D. Conclusions: The PIT-Insomnia has moderate agreement of reliability and reflects the severity of insomnia since it has some concurrent validity with the PSQI. There are some correlations between the PTI-Insomnia with specific psychological tests, so we could suggest it can be used appropriately in the clinical situation.

Sex Determination of Cattle Meat by Polymerase Chain Reaction Amplification of the DEAD Box Protein (DDX3X/DDX3Y) Gene

  • Gokulakrishnan, P.;Kumar, R.R.;Sharma, B.D.;Mendiratta, S.K.;Sharma, D.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.25 no.5
    • /
    • pp.733-737
    • /
    • 2012
  • Determination of sex origin of cattle meat by fast and reliable molecular methods is an important measure to ensure correct allocation of export refunds particularly in European countries and also female cattle (cow) slaughter is legally banned in India because of religious beliefs. Based on the DEAD box protein gene located on the X and Y chromosomes, 2 pair of primers were designed and the system of PCR was optimized. Upon PCR amplification, male tissue showed 2 bands, while female tissue resulted in only one band. The accuracy and specificity of the primers was assessed using DNA template extracted from cattle meat of known sex. The protocol was subjected to a blind test and showed 100% concordance, proving its accuracy and reliability.

A study for assessing accuracy rates of pain rating Scales(KPRS & VAS) (국어통증 척도와 시각적 상사 척도의 정확도 연구)

  • 이은옥;정면숙
    • Journal of Korean Academy of Nursing
    • /
    • v.18 no.3
    • /
    • pp.239-244
    • /
    • 1988
  • The purpose of this study was to identify the accuracy rates(hit ratio) which mean the degree of concordance between pain rating scale differences over time & subjective comparisons. Subjective comparisons mean the responses to the question “how does the pain you are now experiencing compare with the one at the time of the assessment yesterday\ulcorner” Answers to this question were translated into ‘greater’, ‘same’, or ‘less’. KPRS(Korean Pain Rating Scale) was developed through 4 consecutive studies to assess pain extensively & accurately by Lee etc. VAS(Visual Analogue Scale) was reported as valid & veliable measure for the intensity of pain by many researchers. Thirty hospitalized patients with complaints of Headache were partispated in this study during the period from May 1 to July 31, 1987. In conclusion, the accuracy rates of KPRS and VAS were 60%, 67%, respectively.

  • PDF

A Study on the Harmonization of Poisonous Substance Used in Paint Manufacture (도료제조업종에서 취급하는 유독물의 GHS 분류 통일화 방안 연구)

  • Lee, Jong Han;Hong, Mun Ki;Kim, Hyun Ji;Park, Sang Hee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.2
    • /
    • pp.156-163
    • /
    • 2013
  • Objectives: Numerous poisonous substances are used in paint manufacture, but there are differences in the results of GHS classification between the Ministry of Labor(MOL) and the Ministry of Environment(MOE). Therefore, paint manufacturers suffer confusion as to how to classify a given chemical's risk and hazard level. This paper was designed to compare the classification results of chemicals by the MOL and the MOE and suggest a harmonization measure. Methods: After selecting 25 poisonous substances from among the organic solvents, pigments, and additives used in paint manufacturer, the GHS classification results by MOL and MOE were compared. Further the logic and classification of the GHS proposed by each Ministry was analyzed. Based on the derived results, a harmonization plan was proposed. Results: Based on the GHS classification of the poisonous substances, the concordance is 10.0-66.6 %, excluded flammable liquid. The GHS classifications differed based on the suggested building blocks, the sub-classification method used, the references(data sources), and subjective judgment of the experts from each Ministry. In order to pursue the harmonization plan, cooperation is demanded from the MOL and MOE.

A Study on the Validity of 'Hepa-S' Hepatitis B Antibody Detecting Reagent after Vaccination of 'Hepa-Vax' (B형 간염백신 'Hepa-Vax' 접종후 항체검사시약 'Hepa-S' kit의 정확도에 관한 연구)

  • Moon, In-Sook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.18 no.1
    • /
    • pp.51-57
    • /
    • 1985
  • To attempt to measure the effect of domestic product P.H.A. kit 'Hepa-S' after completion of 'Hepa-Vax' vaccination schedule, P.H.A. test and R.I.A. test on the 330 healthy adults were carried out. The results obtained were as follow ; 1. The positive anti HBs rate after completion of 'Hepa-Vax' vaccination were; in P.H.A. test with domestic product P.H.A. kit 81.2%, in P.H.A. test with foreign product P.H.A. kit 82.7%, and in R.I.A. test 95.8% 2. Using the result of R.I.A. test as the standard, sensitivity of P.H.A. test with domestic product P.H.A. kit was 84.8% and specificity was 100.0% 3. Using the result of R.I.A. test as standard, sensitivity of P.H.A. test with foreign P.H.A. kit was 86.4% and specificity was 100.0%. 4. The concordance rate of P.H.A. test with domestic product and foreign product kit was 98.5%. On the result of this study, there was no significant difference in the validity between the domestic product P.H.A. kit 'Hepa-S' and the foreign P.H.A. kit $'Hebsgencell^{TM}'$. So that it is recommendable to use domestic product P.H.A. kit instead of foreign product P.H.A. kit.

  • PDF