• Title/Summary/Keyword: Concentration variation

Search Result 2,461, Processing Time 0.03 seconds

One-Year Continuous Measurement of Outdoor Radon Progeny Concentration in Beijing Area

  • Zhang, Lei;Wang, Yunxiang;Guo, Qiuju
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.3
    • /
    • pp.95-100
    • /
    • 2020
  • Background: Compared with reported data of radon concentration, data of radon progeny concentration is limited in general, especially in outdoor environment. Materials and Methods: To know both the level and the variation of radon progeny concentration in outdoor environment in Beijing area, one-year continuous measurement with a cycle of 60 minutes was carried out by a step-advanced filter (SAF) monitor for radon progeny measurement. The observation site was located in a park in Eastern Beijing area, and the observation period was from October 17, 2018 to September 29, 2019. Results and Discussion: The equivalent equilibrium concentration (EEC) of radon progeny varies from 0.7 to 19.1 Bq·m-3, with an annual average of 4.9 ± 2.7 Bq·m-3. A clear diurnal variation of EEC, higher in the early morning and lower in the late afternoon, is observed due to the high sensitivity of the SAF monitor. Conclusion: Vertical convection of atmospheric boundary layer is thought to be the main reason of this phenomenon. For annual variation, the lowest monthly average EEC appeared in April, while the highest appeared in November, which might attribute to the atmospheric stability in different seasons.

Characteristics of Air Pollution at Kimhae (김해지방의 대기오염 특성)

  • 박종길;김종필;김지형
    • Journal of Environmental Science International
    • /
    • v.8 no.1
    • /
    • pp.33-43
    • /
    • 1999
  • This paper aims to describe the characteristics of air pollution using air pollutants concentration and meteorological data observed at Kimhae from December 1996 to November, 1997. The results are as follows : The concentration distribution of sulfur dioxide($SO_2$), carbon monoxide(CO), particulate matter(PM-10), and nitrogen dioxide($NO_2$) is high during the late fall and winter and low during the summer, but ozone concentration is low during the winter season and high during summer season except Jangma period and these distributions appear to be closely connected with insolation and the number of clear day. Diurnal variation of concentrations for sulfur dioxide, particulate matter, and carbon monoxide are high during the rush hours and nighttime and low during the daytime and these variations are distinct toward the winter season. And diurnal variation of nitrogen dioxide concentration has also same pattern and these patterns are closely related to the increasing traffic volume at rush hours. Diurnal variation of ozone concentration is generally increase for daytime and decrease for the late afternoon and are closely related to the insolation and photochemical reaction. The 24 hour average concentrations of air pollutant observed at Kimhae represented a positive correlation and a negative correlation for $O_3$ and also a negative correlation for the meteorological elements such as wind speed and cloud cover.

  • PDF

A study on the Character of Water Quality according to the Flux in Pal-Dang Reservoir (팔당호 유량변동에 따른 수질특성에 관한 연구)

  • 김종민
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.1
    • /
    • pp.12-24
    • /
    • 1995
  • I tried to evaluate the reason of the monthly variation of water quality according to the hydrologic character of Pal- dang reservoir inflow variation. The result of this study is as below; 1 ) COD, BOD, Total- nitrogen and Total- phosphate concentration increase generally according to the flux and Total- phosphate concentration is the most affected item by flux. 2) COD, BOD, Total- nitrogen and Total- phosphate concentration increase according the flux, but they begin to decrease at the below point ; COD · 1,154 CMS, BOD : 1,007 (CMS cubicmeter per second ) and Inflow- Concentration interrelation formula is as below; table omitted.

  • PDF

A Study on the Stress Distribution and Stress Concentration of Pipe with Respect to Attached Shape and Method of the Bracket in a Welding Structure (브래킷 결합형식에 따른 용접 구조물의 파이프에서 발생하는 응력분포와 응력집중에 관한 연구)

  • Jeon, Hyung-Yong;Sung, Rak-Won;Han , Geun-Jo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.8
    • /
    • pp.28-37
    • /
    • 1999
  • This investigation is the result of the structural analysis by finite element method and test for considering stress distribution and stress concentration to be generated according to the change of attached shape and method of the bracket to pipe in welding structure. Generally, members that consist structures are subjected to various forces and are jointed each other with a number of bracket. In this case, circular pipe was adapted in order to weld these members easily and to study the optimal design which is used a beam with shape section as main components of the structure, According to attached shape and method, distributed stress on circular pipe is appeared so differently. This may result deeply effects with respect to thickness, material properties. So a study on attaching shape and method of bracket to circular pipe is needed. In this paper, to obtain the maximum equivalent stress or stress concentration was used experimental and F.E.M. analysis. First five parameter was defined with respect to attached a shape and method to circular pipe i.e. the variation of the attached area, the variation of the attached shape, the variation of the attached length, the variation of both directin angles, the variation of the upper angle. Afterward the experimental analysis was practiced as the variation of the both direction angel and the finite element analysis was practiced as each parameters. We can discover stress distribution and stress concentration according to the change of form of bracket. And the result can be referenced for a design of similar structure.

  • PDF

Seasonal variation of concentration and size distribution of Ionic species on aerosol in urban air (도시대기 입자상물질중 수용성 성분의 농도와 입경분로의 계절적 변동)

  • 이승일;황경철;조기철;신영조;김희강
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.3
    • /
    • pp.64-71
    • /
    • 1996
  • Measurement of concentration and size distribution of TSP, ammonium, nitrate and sulfate were made from Mar., 1991. to June., 1992 in Seoul. The seasonal variation of concentration and size distribution of aerosols has been investiated. Aerosol were collected and size frationated by Andersen air sampler. Size classified samples were extrated with deionized water and analyzed for ammonium, nitrate and sulfate by ion chromatography. As the results of measurement, the average of concentration and MMAD(mass median aerodynamic diameter) were $118.58 \mu g/m^3$, and $2.77 \mu m$ for TSP, $1.92 \mu g/m^3$ and $1.35 \mu m$ for ammonium, $1.34 \mu g/m^3$ and $1.58 \mu m$ for nitrate, $8.52 \mu g/m^3$ and $2.15 \mu m$ for sulfate. The Seasonal variation of concentration and size distribution was observed for ammonium, nitrate and sulfate. The concentration peak of TSP was observed in coarse particles in spring and observed in fine particles in winter. The concentration's distribution of TSP, ammonium, nitrate and sulfate was observed bimodal type during all season.

  • PDF

The Meteorological Factors Governing $SO_2$ Concentrations During the Wintertime in Seoul Area (서울 지역 겨울철 $SO_2$ 농도를 지배하는 기상 인자)

  • 박일수;이덕길;강인구
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.7 no.2
    • /
    • pp.96-104
    • /
    • 1991
  • An investigation is carried out for the roles of the synoptic meteorology in governing $SO_2$ concentrations in Seoul during the wintertime. This study has used the daily records of wind and temperature measured at the Korea Meteorological Administration in Seoul. A one-dimensional diffusion model has been used for investigating the influence of the mixing height on the diurnal variation of concentration. The day to day variations of the concentration are well correlated with those of wind and temperature. The diurnal variation of the concentration is dictated by the variation of mixing height. It is also found that mesoscale wind field is required to explain the mesoscale distribution of the concentration.

  • PDF

Seasonal variation of flavonoid glycosides in Epimedium koreanum (삼지구엽초(三枝九葉草) Flavonoid Glycoside의 계절적(季節的) 변동(變動))

  • Kang, Sam-Sik;Kim, Ju-Sun
    • Korean Journal of Pharmacognosy
    • /
    • v.22 no.2
    • /
    • pp.85-90
    • /
    • 1991
  • The seasonal variation of two flavonol glycosides, icariin and epimedoside A, in the aerial parts and underground parts of Epimedium koreanum from June through September was investigated. The icariin concentration was decreased with time in both parts. Epimedoside A concentration was fluctuated, being highest in June and lowest in July in the underground parts. In the aerial parts, however, it was almost same in concentration. Determinations were made of the occurrence of two new flavonol glycosides, 2‘-O-rbamnosyl ikarisoside A and 2’-O-rhamnosyl icarisid II in the aerial parts and their changes in concentration were similar to those in the underground parts, being highest in July in both parts.

  • PDF

Synoptic Weather Patterns and Variation of Ozone Concentrations Association with High Ozone Days at Five Major Cities in Korea (고농도 오존이 발생하는 날의 종관 기상 패턴과 주요 5대 도시별 오존 농도 변화)

  • 김유라;윤일희;김희종
    • Journal of Environmental Science International
    • /
    • v.10 no.6
    • /
    • pp.437-444
    • /
    • 2001
  • The characteristic features of surface ozone concentration and the forecasting procedure of high ozone days have been studied. The ozone concentration was continuously measured during 3 years (1997~1999) at air quality monitoring stations in five major cities in Korea. The diurnal variation of surface ozone concentration on high ozone days is characterized by low ozone concentration at night. The ozone concentration Increases continuously after sunrise, In reach a peak at 1500~1600 LST. Thereafter it decreases steadily to a low concentration at sunset. The diurnal and annual maximum of the surface ozone concentration at Seoul were observed in May and June, respectively. The favorable synoptic condition for the high ozone day is divided into 4 different synoptic weather patterns: a high-pressure system from the Sea of Okhotsk, the Pacific subtropical high extending westward, a moving high-pressure system covering the Korean peninsula. and a synoptic system In front of a typhoon. Most of high ozone days occur under the high pressure system in Korea.

  • PDF

Evaluation of Variation Method to Improve the Sensitivity of Immunoradiometric Assay (면역방사계수측정법의 민감도 향상을 위한 변법의 평가)

  • Won-Hyun Kwon;Mi-Ji Kang;;Ji-Sol Park;Jung-In Kim;Kyung-Jae Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.29-35
    • /
    • 2023
  • Purpose The concentration of PSA (Prostate Specific Antigen) after radical prostatectomy in prostate cancer patients is a predictor of biochemical recurrence, and the AUA (American Urological Association) is defined as biochemical recurrence when the concentration of PSA is measured at 0.2 ng/mL or more, and when the concentration is measured at 0.2 ng/mL or more at the retest. This standard is also applied our hospital. In this laboratory, the PSA reagent using IRMA (Immunoradiometric Assay) is used, and the sensitivity at a very low value was not as good as the reagent used in the department of laboratory medicine. This study aims to increase the reliability of the results by improving the precision and sensitivity of very low values. Materials and Methods As a reagent for the study, PSA reagent using IRMA was used. As a method to improve the precision and sensitivity of very low values, a variation method on the serum volume(25 uL, 50 uL, 100 uL, 200 uL) was studied, and variation usefulness evaluation was conducted. The evaluation items were compared the results of precision, analytical sensitivity, recovery rate, dilution test, high-dose hook effect test, parallel test and very low concentration values(n = 20). Results The validation results were displayed in the order of 25 uL, 50 uL, 100 uL, 200 uL. As the serum volume increased, it was confirmed that CV (Coefficient of Variation)(%) improved. Analytical sensitivity(ng/mL) was 0.038, 0.041, 0.017, 0.015 and recovery rate(%) was 101±3, 101±3, 99±2, 97±4. very low concentration values(ng/mL) between each volume(n=20) were 0.135±0.068, 0.076±0.050, 0.048±0.034, 0.046±0.034. and high dose hook effect appeared as the serum volume increased. Conclusion Through the variation usefulness evaluation, it was confirmed that as the serum volume increased, the precision and sensitivity improved at very low concentration values. However, it is necessary to pay special attention to the occurrence of high-dose hook effect as the serum volume increases. In the case of tests that requires very low concentration values, it is thought that the reliability of the result will be increased if the variation method is properly used after the variation usefulness evaluation.

  • PDF

Variation of Phosphorus and Nitrogen Removal Characteristics According to the Decrease of Influent Phosphorus Concentration in SBR and SBBR (SBR과 SBBR에서 유입 인 농도 감소에 따른 인과 질소의 제거 특성 변화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.19 no.4
    • /
    • pp.483-490
    • /
    • 2010
  • The purpose of this study is to investigate the effect of influent phosphorus concentration on the nitrogen and phosphorus removal in sequencing batch reactor(SBR) and sequencing batch biofilm reactors(SBBRs) in order to recover the enhanced biological phosphorus removal (EBPR) capacity at the sludge of the deterioration of EBPR capacity. In SBBRs, comparing to SBR, the organic removal was occurred actively at the 1 st non-aeration period because of the active phosphorus release at this period. However, the variation of TOC removal according to the decrease of influent phosphorus concentration was not clearly shown both in SBR and SBBRs. In case of SBR losing EBPR capacity, the EBPR capacity was not recovered by the decrease of the influent phosphorus concentration from 7.5 mg/L to 0.9 mg/L. The nitrogen removal increased by the decrease of influent phosphorus concentration both in SBR and SBBRs.