• Title/Summary/Keyword: Computer-guided

Search Result 294, Processing Time 0.027 seconds

A Design and Implementation of Class Management Support System for Effective Class Management (효율적인 학급 경영을 위한 학급 경영 지원시스템의 설계 및 구현)

  • Kim, Chul;Jung, Oh-Soo;Kim, Eun-Soo
    • Journal of The Korean Association of Information Education
    • /
    • v.6 no.1
    • /
    • pp.75-85
    • /
    • 2002
  • The change of following information society, now a point of time is that we need a cyberspace as Class Management Support System for effective classroom Management of web base and realized it and then tried to find the Internet use direction correctively. It guided more effective class management. Class Management Support System is applied that are realized information possibly in Web according to class management's work. we will incite more the Internet use resource is made ability to use in learning and stimulated their hobbies and specialities. That can be resulted fully the support role of usual calss management escape from time and space restriction. So we adapted this system when we leaded students participated themselves actively about student's activity, prospected the chance which is accomplished higher advanced education.

  • PDF

Hybrid Filter Based on Neural Networks for Removing Quantum Noise in Low-Dose Medical X-ray CT Images

  • Park, Keunho;Lee, Hee-Shin;Lee, Joonwhoan
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.15 no.2
    • /
    • pp.102-110
    • /
    • 2015
  • The main source of noise in computed tomography (CT) images is a quantum noise, which results from statistical fluctuations of X-ray quanta reaching the detector. This paper proposes a neural network (NN) based hybrid filter for removing quantum noise. The proposed filter consists of bilateral filters (BFs), a single or multiple neural edge enhancer(s) (NEE), and a neural filter (NF) to combine them. The BFs take into account the difference in value from the neighbors, to preserve edges while smoothing. The NEE is used to clearly enhance the desired edges from noisy images. The NF acts like a fusion operator, and attempts to construct an enhanced output image. Several measurements are used to evaluate the image quality, like the root mean square error (RMSE), the improvement in signal to noise ratio (ISNR), the standard deviation ratio (MSR), and the contrast to noise ratio (CNR). Also, the modulation transfer function (MTF) is used as a means of determining how well the edge structure is preserved. In terms of all those measurements and means, the proposed filter shows better performance than the guided filter, and the nonlocal means (NLM) filter. In addition, there is no severe restriction to select the number of inputs for the fusion operator differently from the neuro-fuzzy system. Therefore, without concerning too much about the filter selection for fusion, one could apply the proposed hybrid filter to various images with different modalities, once the corresponding noise characteristics are explored.

OBSERVATIONS OF EUV RECURRING JETS IN AN ACTIVE REGION CONFINED BY CORONAL LOOPS

  • Zheng, Yan-Fang;Wang, Feng;Ji, Kai Fan;Deng, Hui
    • Journal of The Korean Astronomical Society
    • /
    • v.46 no.5
    • /
    • pp.183-190
    • /
    • 2013
  • Recurring jets, which are jets ejected from the same site, are a peculiar type among various solar jet phenomena. We report such recurring jets ejecting from the same site above an active region on January 22, 2012 with high-resolution multi-wavelength observations from Solar Dynamics Observatory(SDO). We found that the recurring jets had velocities, lengths and lifetimes, but had similar directions. The visible brightening appeared at the jet base before each jet erupted. All the plasma produced by the recurring jets could not overcome the large coronal loops. It seemed that the plasma ejecting from the jet base was confined and guided by preexisting coronal loops, but their directions were not along the paths of the loops. Two of the jets formed crossing structures with the same preexisting filament. We also examined the photospheric magnetic field at the jet base, and observed a visible flux emergence, convergence and cancellation. The four recurring jets all were associated with the impulsive cancellation between two opposite polarities occurring at the jet base during each eruption. In addition, we suggest that the fluxes, flowing out of the active region, might supply the energy for the recurring jets by examining the SDO/Helioseismic and Magnetic Imager (HMI) successive images. The observational results support the magnetic reconnection model of jets.

Electronic Risk Assessment System as an Appropriate Tool for the Prevention of Cancer: a Qualitative Study

  • Amoli, Amir hossein Javan;Maserat, Elham;Safdari, Reza;Zali, Mohammad Reza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8595-8598
    • /
    • 2016
  • Background: Decision making modalities for screening for many cancer conditions and different stages have become increasingly complex. Computer-based risk assessment systems facilitate scheduling and decision making and support the delivery of cancer screening services. The aim of this article was to survey electronic risk assessment system as an appropriate tool for the prevention of cancer. Materials and Methods: A qualitative design was used involving 21 face-to-face interviews. Interviewing involved asking questions and getting answers from exclusive managers of cancer screening. Of the participants 6 were female and 15 were male, and ages ranged from 32 to 78 years. The study was based on a grounded theory approach and the tool was a semi-structured interview. Results: Researchers studied 5 dimensions, comprising electronic guideline standards of colorectal cancer screening, work flow of clinical and genetic activities, pathways of colorectal cancer screening and functionality of computer based guidelines and barriers. Electronic guideline standards of colorectal cancer screening were described in the s3 categories of content standard, telecommunications and technical standards and nomenclature and classification standards. According to the participations' views, workflow and genetic pathways of colorectal cancer screening were identified. Conclusions: The study demonstrated an effective role of computer-guided consultation for screening management. Electronic based systems facilitate real-time decision making during a clinical interaction. Electronic pathways have been applied for clinical and genetic decision support, workflow management, update recommendation and resource estimates. A suitable technical and clinical infrastructure is an integral part of clinical practice guidline of screening. As a conclusion, it is recommended to consider the necessity of architecture assessment and also integration standards.

Geomulticast: Location based Multicast Routing Protocol using Route Stability in Mobile Ad-hoc Wireless Networks (지오멀티캐스트: 모바일 Ad-hoc 무선 네트워크에서 경로 안정성을 이용한 위치기반 멀티캐스트 라우팅 프로토콜)

  • Ha, Sue Hyung;Le, The Dung;An, Beongku
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.7
    • /
    • pp.191-201
    • /
    • 2013
  • In this paper, we propose a location based multicast routing protocol, called Geomulticast, in mobile ad-hoc wireless networks. The main features and contributions of the proposed geomulticast are as follows. First, support data transmission to only the specific mobile nodes within a target area. Second, establish stable routing route by using mobility information of nodes. Third, reduce control overhead, power for construction of routing route by using geomulticast guided line information. Fourth, present a theoretical model for establishing stable route. The performance evaluation of the proposed geomulticast is executed by using OPNET simulation and theoretical analysis, and the results of simulation and theoretical analysis have similar patterns. And we can see that data packets are efficiently transmitted to specific user groups within a specific area.

AGV Dispatching with Stochastic Simulation (확률적 시뮬레이션 기반 AGV 배차)

  • Choe, Ri;Park, Tae-Jin;Ryu, Kwang-Ryel
    • Journal of Navigation and Port Research
    • /
    • v.32 no.10
    • /
    • pp.837-844
    • /
    • 2008
  • In an automated container terminal, various factors affect the operation of container handling equipment such as quay cranes and AGVs, and thus calculating the exact operation time is nearly infeasible. This uncertainty makes it difficult to dispatch AGVs well. In this paper, we propose a simulation-based AGV dispatching algorithm When dispatching an AGV to an operation, the proposed algorithm conducts multiple stochastic simulation for the succeeding AGV operations for the predetermined period to collect stochastic samples of the result of the dispatching. In the stochastic simulation, the uncertainty of crane operations is represented as a simple probability distribution and the operation time of a crane is determined according to this. A dispatching option is evaluated by the total delay time of quay cranes which is estimated by averaging the quay crane delay of each simulation In order to collect a sufficient number of samples that guarantee the credibility of the evaluation, we devised a high-speed simulator that simulates AGV operation The effectiveness of the proposed algorithm is validated by simulation experiments.

Laserthermia Induced Histological Changes in Different Thermal Condition (Laser Hyperthermia에서 조건변동에 따른 병소변화)

  • Kim, Sang-Woo;Lee, Kyung-Yup;Kim, Seong-Ho;Bae, Jang-Ho;Kim, Oh-Lyong;Choi, Byung-Yearn;Cho, Soo-Ho;Shin, Hyun-Jin;Lee, Jun-Ha
    • Journal of Yeungnam Medical Science
    • /
    • v.12 no.2
    • /
    • pp.331-338
    • /
    • 1995
  • Laserthermia is a new method of local hyperthermia using fiber optic guided probe with computer controlled Nd-YAG laser system. We used a synthetic sapphire probe and allowed irradiation with contolled low power laser energy (less than 5W), in different thermal condition (temprature: 38.5~50 degrees C) for 10 minutes, in the normal brain tissue of 18 rabbits. In results, the histological changes of brain tissue was variable (myelin condensation, chromatin condensation, nuclear waving and palisading, RBC discoloration, cell necrosis) in microscopic findings after laser irradiation, but changing area was not occured proportionally in thermal condition level. Cell necrosis appears to over 44.5 degrees C and the distance was about 1.25 mm. This study, using computer controlled laserthermia system for interstitial local hyperthermia, may offer many advantages in the experimental treatment and clinical management of tumor. Minimizing normal tissue damage is now being developed.

  • PDF

Lightweight Attention-Guided Network with Frequency Domain Reconstruction for High Dynamic Range Image Fusion

  • Park, Jae Hyun;Lee, Keuntek;Cho, Nam Ik
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2022.06a
    • /
    • pp.205-208
    • /
    • 2022
  • Multi-exposure high dynamic range (HDR) image reconstruction, the task of reconstructing an HDR image from multiple low dynamic range (LDR) images in a dynamic scene, often produces ghosting artifacts caused by camera motion and moving objects and also cannot deal with washed-out regions due to over or under-exposures. While there has been many deep-learning-based methods with motion estimation to alleviate these problems, they still have limitations for severely moving scenes. They also require large parameter counts, especially in the case of state-of-the-art methods that employ attention modules. To address these issues, we propose a frequency domain approach based on the idea that the transform domain coefficients inherently involve the global information from whole image pixels to cope with large motions. Specifically we adopt Residual Fast Fourier Transform (RFFT) blocks, which allows for global interactions of pixels. Moreover, we also employ Depthwise Overparametrized convolution (DO-conv) blocks, a convolution in which each input channel is convolved with its own 2D kernel, for faster convergence and performance gains. We call this LFFNet (Lightweight Frequency Fusion Network), and experiments on the benchmarks show reduced ghosting artifacts and improved performance up to 0.6dB tonemapped PSNR compared to recent state-of-the-art methods. Our architecture also requires fewer parameters and converges faster in training.

  • PDF

Full mouth rehabilitation using 3D printed crowns and implant assisted removable partial denture for a crossed occlusion: a case report (3D 프린팅 금관과 임플란트 보조 국소의치를 이용한 엇갈린 교합의 전악 수복 증례)

  • Sung-Hoon Lee;Seong-Kyun Kim;Seong-Joo Heo;Jai-Young Koak;Ji-Man Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.367-378
    • /
    • 2023
  • With the recent development of computer-aided design-computer-aided manufacturing technology and 3D printing technology, and the introduction of various digital techniques, the accuracy and efficiency of top-down definitive prosthetic restoration are increasing. In this clinical case, stable occlusion support was obtained through the placement of a total of 9 maxillary and mandibular posterior implants in patient with anterior-posterior crossed occlusion. The edentulous area of the maxillary anterior teeth, which showed a tendency of high resorption of the residual alveolar bone, was restored with a Kennedy Class IV implant assisted removable partial denture to restore soft tissue esthetics. Computed tomography guided surgery was used to place implants in the planned position, double scan technique was used to reflect the stabilized occlusion in the interim restoration stage to the definitive prostheses, and metal 3D printing was used to manufacture the coping and framework. This clinical case reports that efficient and predictable top-down full mouth rehabilitation was achieved using various digital technologies and techniques.

Accuracy of 5-axis precision milling for guided surgical template (가이드 수술용 템플릿을 위한 5축 정밀가공공정의 정확성에 관한 연구)

  • Park, Ji-Man;Yi, Tae-Kyoung;Jung, Je-Kyo;Kim, Yong;Park, Eun-Jin;Han, Chong-Hyun;Koak, Jai-Young;Kim, Seong-Kyun;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.294-300
    • /
    • 2010
  • Purpose: The template-guided implant surgery offers several advantages over the traditional approach. The purpose of this study was to evaluate the accuracy of coordinate synchronization procedure with 5-axis milling machine for surgical template fabrication by means of reverse engineering through universal CAD software. Materials and methods: The study was performed on ten edentulous models with imbedded gutta percha stoppings which were hidden under silicon gingival form. The platform for synchordination was formed on the bottom side of models and these casts were imaged in Cone beam CT. Vectors of stoppings were extracted and transferred to those of planned implant on virtual planning software. Depth of milling process was set to the level of one half of stoppings and the coordinate of the data was synchronized to the model image. Synchronization of milling coordinate was done by the conversion process for the platform for the synchordination located on the bottom of the model. The models were fixed on the synchordination plate of 5-axis milling machine and drilling was done as the planned vector and depth based on the synchronized data with twist drill of the same diameter as GP stopping. For the 3D rendering and image merging, the impression tray was set on the conbeam CT and pre- and post- CT acquiring was done with the model fixed on the impression body. The accuracy analysis was done with Solidworks (Dassault systems, Concord, USA) by measuring vector of stopping’s top and bottom centers of experimental model through merging and reverse engineering the planned and post-drilling CT image. Correlations among the parameters were tested by means of Pearson correlation coefficient and calculated with SPSS (release 14.0, SPSS Inc. Chicago, USA) ($\alpha$ = 0.05). Results: Due to the declination, GP remnant on upper half of stoppings was observed for every drilled bores. The deviation between planned image and drilled bore that was reverse engineered was 0.31 (0.15 - 0.42) mm at the entrance, 0.36 (0.24 - 0.51) mm at the apex, and angular deviation was 1.62 (0.54 - 2.27)$^{\circ}$. There was positive correlation between the deviation at the entrance and that at the apex (Pearson Correlation Coefficient = 0.904, P = .013). Conclusion: The coordinate synchronization 5-axis milling procedure has adequate accuracy for the production of the guided surgical template.