• Title/Summary/Keyword: Computer tomography

Search Result 424, Processing Time 0.03 seconds

EVALUATION OF CONDYLAR DISPLACEMENT USING COMPUTER TOMOGRAPHY AFTER THE SURGICAL CORRECTION OF MANDIBULAR PROGNATHISM (전산화단층촬영법을 이용한 하악전돌증 환자의 외과적 악교정술후 하악과두 위치 변화 검토)

  • Lee, Ho-Kyung;Jang, Hyun-Jung;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.3
    • /
    • pp.191-200
    • /
    • 1998
  • This study was intended to perform the influence of condyle positional change after surgical correction of skeletal Class III malocclusion after orthognathic surgery in 37 patients(male 13, female 24) using computed tomogram that were taken in centric occlusion before, immediate after, and long term after surgery and lateral cephalogram that were taken in centric occlusion before, 7 days within the period of intermaxillary fixation, at the 24 hours later removing intermaxillary fixation and long term after surgery. 1. Mean intercondylar distance was $84.42{\pm}5.30mm$ and horizontal long axis of condylar angle was $12.79{\pm}4.92^{\circ}$ on the right, $13.53{\pm}5.56^{\circ}$ on the left side. Condylar lateral poles were located about 12mm and medial poles about 7mm away from the reference line(AA') on the axial tomogram. Mean intercondylar distance was $83.15{\pm}4.62mm$ and vertical axis angle of condylar angle was $76.28{\pm}428^{\circ}$ on the right, $78.30{\pm}3.79^{\circ}$ on the left. 2. In amount of set back, We found the condylar change(T2C-T1C) which had increasing tendency in group III (amount of setback : 10-15mm). but there was no statistical significance(p>0.05). 3. There was some correlation between condylar change(T2C-T1C) and TMJ dysfunction. It seemed that postoperative condylar change had influenced postoperative TMJ dysfunction, through there was no statistical significance (p>0.05). As we have observed the change of condylar axis in the group that complained of TMJ dysfunction in cases of large amount of mandibular setback. So we consider that the more trying to conserve condylar position will decrease occurrence rate of post operational TMJ dysfunction.

  • PDF

Effect of bone-implant contact pattern on bone strain distribution: finite element method study (골-임플란트 접촉 양상에 따른 골 변형 연구: 유한요소법적 연구)

  • Yoo, Dong-Ki;Kim, Seong-Kyun;Koak, Jai-Young;Kim, Jin-Heum;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.214-221
    • /
    • 2011
  • Purpose: To date most of finite element analysis assumed the presence of 100% contact between bone and implant, which is inconsistent with clinical reality. In human retrieval study bone-implant contact (BIC) ratio ranged from 20 to 80%. The objective of this study was to explore the influence of bone-implant contact pattern on bone of the interface using nonlinear 3-dimensional finite element analysis. Materials and methods: A computer tomography-based finite element models with two types of implant (Mark III Br${\aa}$nemark$^{(R)}$, Inplant$^{(R)}$) which placed in the maxillary 2nd premolar area were constructed. Two different degrees of bone-implant contact ratio (40, 70%) each implant design were simulated. 5 finite element models were constructed each bone-implant contact ratio and implant design, and sum of models was 40. The position of bone-implant contact was determined according to random shuffle method. Elements of bone-implant contact in group W (wholly randomized osseointegration) was randomly selected in terms of total implant length including cortical and cancellous bone, while ones in group S (segmentally randomized osseointegration) was randomly selected each 0.75 mm vertically and horizontally. Results: Maximum von Mises strain between group W and group S was not significantly different regardless of bone-implant contact ratio and implant design (P=.939). Peak von Mises strain of 40% BIC was significantly lower than one of 70% BIC (P=.007). There was no significant difference between Mark III Br${\aa}$nemark$^{(R)}$ and Inplant$^{(R)}$ in 40% BIC, while average of peak von Mises strain for Inplant$^{(R)}$ was significantly lower ($4886{\pm}1034\;{\mu}m/m$) compared with MK III Br${\aa}$nemark$^{(R)}$ ($7134{\pm}1232\;{\mu}m/m$) in BIC 70% (P<.0001). Conclusion: Assuming bone-implant contact in finite element method, whether the contact elements in bone were wholly randomly or segmentally randomly selected using random shuffle method, both methods could be effective to be no significant difference regardless of sample size.

Cardiac Injury due to Thoracic Trauma (흉부외상에 의한 심장손상)

  • Kim, Han-Yong;Kim, Myoung-Young;Park, Jae-Hong;Chei, Chang-Seck;Hwang, Sang-Won
    • Journal of Chest Surgery
    • /
    • v.40 no.12
    • /
    • pp.831-836
    • /
    • 2007
  • Background: Cardiac injuries are the most commonly overlooked injuries in patients who die from trauma. Patients who survive blunt cardiac rupture or penetrating injuries are rare and the incidence is not well defined. Many patients require urgent or emergency operations and operative mortality is very high. Material and Method: A retrospective review of 26 patients with cardiac injuries due to thoracic trauma undergoing emergency thoracotomy from January 1997 to December 2005. Result: There were 17 male and 9 female patients, with a mean age of $45.3{\pm}16.2\;(range:\;17{\sim}80)$. Thirteen patients (50%) were injured in motor vehicle accidents, and five patients (19%) in motorcycle accidents. Six patients (23%) were injured by knives, and two patients (8%) were injured by falling. Anatomic injuries included right atrium (12 [46%]), left atrium (1 [4%]), right ventricle (5 [19%]), left ventricle (5 [19%]), and cardiac chambers (2 [7%]). Diagnosis was made by computer tomography in 12 patients and sonography in 14 patients. The average times from admission to operating room was $89.2{\pm}86.7\;min\;(range:\;10{\sim}335)$. The average time for diagnosis was $51.3{\pm}13.6\;min\;(range:\;5{\sim}280)$. The mean Revised Trauma Score (RTS) was $6.7{\pm}0.8$, and the Glasgow Coma Scale (GCS), was $12.8{\pm}2.8$. The overall mortality rate was 12% (3 out of 26 patients). Conclusion: The mortality rate from cardiac injury is very high. The survival rate can be increased only by a high index of suspicion, aggressive expeditious diagnostic evaluation, and prompt appropriate surgical management.

Facial soft tissue measuring analysis of normal occlusion using three-dimensional CT imaging (3차원 CT 영상을 이용한 정상교합자의 안면 연조직 계측 분석)

  • Han, Soo-Yeon;Baik, Hyoung-Seon;Kim, Kee-Deog;Yu, Hyung-Seog
    • The korean journal of orthodontics
    • /
    • v.35 no.6 s.113
    • /
    • pp.409-419
    • /
    • 2005
  • Studies for diagnostic analysis using three-dimensional (3D) CT images are recently in progress and needs for 3D craniofacial analysis are increasing in the fields of orthodontics. It is especially essential to analyze the facial soft tissue after orthodontic treatment and orthognathic surgery. In this study 3D CT images of adults with normal occlusion were taken to analyze the facial soft tissue. Norms were obtained from CT images of adults with normal occlusion (12 males, 11 females) using a computer program named V works 4.0 program. 3D coordinate planes were established using soft tissue Nasion as the reference point and a total of 20 reproducible landmarks of facial soft tissue were obtained using the multiple reconstructive sectional images (axial, sagittal and coronal images) of the V works 4.0 program: soft tissue Nasion, Pronasale, Subnasale, Upper lip center, Lower lip center, soft tissue B, soft tissue Pogonion, soft tissue Menton, Endocanthion (Rt/Lt), Alare lateralis (Rt/Lt), Cheilion (Rt/Lt), soft tissue Gonion (Rt/Lt), Tragus (Rt/Lt), and Zygomatic point (Rt/Lt). According to the established landmarks and measuring method, the 3D CT images of adults with normal occlusion were measured and the normal positional measurements and their Net (${\delta}=\sqrt{{X^2}+{Y^2}+{Z^2}}$) values were obtained using V surgery program, In the linear measurement between landmarks, there was a significant difference between males and females except Na' -Sn and En(Rt)-En(Lt). The normal ranges of Na'-Zy, Na'-Ch and Na'-Go' (facial depth) were obtained, which was difficult to measure by two-dimensional (2D) cephalometric analysis and facial photographs. These data may be used as references for 3D diagnosis and treatment planning for patients with malocclusion and dentofacial deformity.

Effect of GB 34-GB 39 Electro-acupuncture on Regional Cerebral Blood Flow in Stroke Patients and Normal Volunteers Evaluated by $^{99m}Tc-ECD$ SPECT (양릉천-현종 전침치료가 뇌경색환자 및 정상인의 뇌혈류에 미치는 영향 - SPECT와 SPM을 이용한 연구 -)

  • Han, Jin-An;Jeong, Dong-Won;Bae, Hyung-Sup;Park, Sung-Uk;Jung, Woo-Sang;Park, Jung-Mee;Ko, Chang-Nam;Cho, Ki-Ho;Kim, Young-Suk;Kim, Deok-Yoon;Moon, Sang-Kwan
    • The Journal of Korean Medicine
    • /
    • v.27 no.3 s.67
    • /
    • pp.187-200
    • /
    • 2006
  • Objectives: Acupuncture has been applied in Asia for thousands of years, especially to rehabilitation after stroke. It has been reported that acupuncture increased cerebral blood supply and stimulated the functional activity of brain nerve cells shown by using brain imaging techniques. This study was to evaluate the effect of GB 34-GB 39 electro-acupuncture (EA) on regional cerebral blood flow (rCBF) in stroke patients and normal volunteers using single photon emission computed tomography (SPECT). Methods: The study procedure was divided into two parts: patients and volunteers studies. For the patients study, ten ischemic stroke patients (3 males, 7 females, mean age $68.5{\pm}8.9$ years old) were selected. Baseline brain SPECT was done with triple head gamma camera (MultiSPECT3, Siemens, USA) after intravenous administration of 1,110 MBq of $^{99m}Tc-ECD$. Fifteen-minute EA at GB 34 and GB 39 were applied on the affected limb. The same dose of $^{99m}Tc-ECD$ was injected during the EA, and the second set of SPECT images wasobtained. Using the computer software (ICON 7.1, Siemens, USA), 3 SPECT slices (upper, middle, lower) surrounding the brain lesion were selected and each slice was divided into 10-16 brain regions. Asymmetry indexes (AI) were analyzed in each brain region. We regarded over 10% changes of AI between before and after EA as significance. For the volunteers study, 10 healthy human volunteers (5 males, 5 females, mean age $28.1{\pm}6$ years old) were selected. In the resting state, $^{99m}Tc-ECD$ brain SPECT scans were performed. On the 7th day after the resting examination, 15 minute EA was applied at GB 34 and GB 39 on the right side of the subjects. Immediately after EA, the second SPECT images were obtained inthe same manner as the resting state. Significant increases and decreases of rCBF after EA were estimated by comparing their SPECT images with those of the resting state using paired t statistics at every voxel, which were analyzed by statistical parametric mapping with a threshold of p = 0.01, uncorrected (extent threshold: k=100 voxels). Results: In stroke patients, six of the eight (75%) had significantly increased perfusion in post-acupuncture scans compared to their baseline state. In normal volunteers, GB 34-GB GB EA increased rCBF in both hemispheres including right ventral posterior cingulate (Brodmann area (BA) 23), left superior temporal, anterior transverse temporal (BA 22, 41), left parastriate, peristriate (BA 18, 19), right occipitotemporal, angular (BA 37, 39), left rostral postcentral, caudal postcentral and preparietal (BA 2, 3, 5). However GB 34-GB 39 EA decreased rCBF in the right hemisphere including triangular and middle frontal lobes. Conclusions: The results demonstrated that OB 34-GB 39 EA increased cerebral perfusion in ischemic stroke patients and increased rCBF grossly in temporal lobes of normal volunteers. It is also suggested that there may be a correlation between the GB meridian and the territory of the middle cerebral artery.

  • PDF

The Heterogeneity of Flow Distribution and Partition Coefficient in [15O-H2O] Myocardium Positron Emission Tomography ([15O-H2O] 심근 양전자 단층 촬영에서 혈류 분포의 비균일성과 분배계수)

  • Ahn, Ji Young;Lee, Dong Soo;Kim, Kyung Min;Jeong, Jae Min;Chung, June-Key;Shin, Seung-Ae;Lee, Myung Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.32-49
    • /
    • 1998
  • For estimation of regional myocardial blood flow with O-15 water PET, a few modifications considering partial volume effect based on single compartment model have been proposed. In this study, we attempted to quantify the degree of heterogeneity and to show the effect of tissue flow heterogeneity on partition coefficient(${\lambda}$) and to find the relation between perfusable tissue index(PTI) and ${\lambda}$ by computer simulation using two modified models. We simulated tissue curves for the regions with homogeneous and heterogeneous blood flow over a various flow range(0.2-4.0ml/g/min). Simulated heterogeneous tissue composed of 4 subregions of the same or different size of block which have different homogeneous flow and different degree of slope of distribution of blood flow. We measured the index representing heterogeneity of distribution of blood flow for each heterogeneous tissue by the constitution heterogeneity(CH). For model I, we assumed that tissue recovery coefficient ($F_{MME}$) was the product of partial volume effect($F_{MMF}$) and PTI. Using model I, PTI, flow, and $F_{MM}$ were estimated. For model II, we assumed that partition coefficient was another variable which could represent tissue characteristics of heterogeneity of flow distribution. Using model II, PTI, flow and ${\lambda}$ were estimated. For the simulated tissue with homogeneous flow, both models gave exactly the same estimates, of three parameters. For the simulated tissue with heterogeneous flow distribution, in model I, flow and $F_{MM}$ were correctly estimated as CH was increased moderately. In model II, flow and ${\lambda}$ were decreased curvi-linearly as CH was increased. The degree of underestimation of ${\lambda}$ obtained using model II, was correlated with CH. The degree of underestimation of flow was dependent on the degree of underestimation of ${\lambda}$. PTI was somewhat overestimated and did not change according to CH. We conclude that estimated ${\lambda}$ reflect the degree of tissue heterogeneity of flow distribution. We could use the degree of underestimation of ${\lambda}$ to find the characteristic heterogeneity of tissue flow and use ${\lambda}$ to recover the underestimated flow.

  • PDF

The Satisfaction Survey of Users and Patients on the Developed Disposable Tourniquet (개발한 일회용 지혈대의 사용자 및 환자 만족도 조사)

  • Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.615-622
    • /
    • 2016
  • The 18~20G needle is used to computer tomography (CT) contrast examination. Therefore, a patient has to apply a self-administering hemostasis (conventional method: CM) and often experience bleeding in the course. Thus, we developed the new disposable transparent tourniquet (TT) for reducing. This study was to compare the usefulness between the proposed transparent tourniquet and the existing hemostatic methods. A Satisfaction survey was conducted by 50 patients and 25nurses. The survey contained the satisfaction of the convenience, safety, sanitation, and wearing sensation of transparent tourniquet. We employed face-to-face interview on 5 points likert scales. And Chi-square, paired T-test were used for the statistics verification. As for the patients, the satisfaction levels were measured for each category with the gender, age. Patients evaluation, overall satisfaction high average sore used TT and there were statistical significance by paired T-test(p<0.05). The following is the average satisfaction level for each category: $4.4{\pm}0.53$ in; $4.28{\pm}0.57$ in safety; $4.52{\pm}0.54$ in sanitation; $4.16{\pm}0.54$ in wearing sensation. So the overall satisfaction level is measured at $4.34{\pm}0.51$. As for the nurses, CT work experience and the current satisfaction with tourniquet were counted as variables. The satisfaction level for each category is: $3.8{\pm}0.7$ in; $3.6{\pm}0.68$ in safety; $3.4{\pm}0.5$ in sanitation; $3.9{\pm}0.49$ in hemostasis. The overall satisfaction level is $3.8{\pm}0.3$. Patients' satisfaction levels were very high with little difference among variables. Nurses' satisfaction levels were different with the TT depending on their work experience but their overall satisfaction was high. This TT will be a starting point to minimizing patient's inconvenience and more studies are necessary to enhance their satisfaction.

Consideration on Measured Patients Dose of Three-Dimensional and Four-Dimensional Computer Tomography when CT-Simulation to Radiation Therapy (방사선치료를 위한 CT 검사 시 3DCT와 4DCT에 대한 피폭선량 고찰)

  • Park, Ryeong-Hwang;Kim, Min-Jung;Lee, Sang-Kyu;Park, Kwang-Woo;Jeon, Byeong-Cheol;Cho, Jeong-Hee;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.341-349
    • /
    • 2011
  • This study was to measure the patient dose difference between 3D treatment planning CT and 4D respiratory gating CT. Study was performed with each 10 patients who have lung and liver cancer for measured patient exposure dose by using SOMATON SENSATION OPEN(SIMENS, GERMANY). CTDIvol and DLP value was used to analyze patient dose, and actual dose was measured in the location of liver and kidney for abdominal examination and lung, heart and spinal cord for chest examination. Rando phantom were used for the experiment. OSLD was used for in-vitro and in-vivo dosimetry. Increasing overall actual dose in 4D respiratory gated CT-simulation using OSLD increase the dose by 5.5 times for liver cancer patients and 6 times for lung cancer patients. In CT simulation of 10 lung cancer patients, CTDIvol value was increased by 5.7 times and DLP 2.4 times. For liver cancer patients, CTDIvol was risen by 3.8 times and DLP 1.6 times. The accuracy of treatment volume could be increased in 4D CT planning for position change due to the breaths of patient in the radiation therapy. However, patients dose was increased in 4D CT than 3D CT. In conclusion, constant efforts is required to reduce patients dose by reducing scan time and scan range.

Field-in-Field Technique to Improve Dose Distribution in the Junction of the Field with Head & Neck Cancer (Field-in-Field Technique을 이용한 두경부암의 접합부위 선량개선에 관한 고찰)

  • Kim, Seon-Myeong;Lee, Yeong-Cheol;Jeong, Deok-Yang;Kim, Young-Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.17-23
    • /
    • 2009
  • Purpose: In treating head and neck cancer, it is very important to irradiate uniform dose on the junction of the bilateral irradiation field of the upper head and neck and the anterior irradiation field of the lower neck. In order to improve dose distribution on the junction, this study attempted to correct non uniform dose resulting from under dose and over dose using the field-in-field technique in treating the anterior irradiation field of the lower neck and to apply the technique to the treatment of head and neck cancer through comparison with conventional treatment. Materials and Methods: In order to examine dose difference between the entry point and the exit point where beam diffusion happens in bilateral irradiation on the upper head and neck, we used an anthropomorphic phantom. Computer Tomography was applied to the anthropomorphic phantom, the dose of interest points was compared in radiation treatment planning, and it was corrected by calculating the dose ratio at the junction of the lower neck. Dose distribution on the junction of the irradiated field was determined by placing low-sensitivity film on the junction of the lower neck and measuring dose distribution on the conventional bilateral irradiation of the upper head and neck and on the anterior irradiation of the lower neck. In addition, using the field-in-field technique, which takes into account beam diffusion resulting from the bilateral irradiation of the upper head and neck, we measured difference in dose distribution on the junction in the anterior irradiation of the lower neck. In order to examine the dose at interest points on the junction, we compared and analyzed the change of dose at the interest points on the anthropomorphic phantom using a thermoluminescence dosimeter. Results: In case of dose sum with the bilateral irradiation of the upper head and neck when the field-in-field technique is applied to the junction of the lower neck in radiation treatment planning, The dose of under dose areas increased by 4.7~8.65%. The dose of over dose areas also decreased by 2.75~10.45%. Moreover, in the measurement using low-sensitivity film, the dose of under dose areas increased by 11.3%, and that of over dose areas decreased by 5.3%. In the measurement of interest point dose using a thermoluminescence dosimeter, the application of the field-in-field technique corrected under dose by minimum 7.5% and maximum 17.6%. Thus, with the technique, we could improve non.uniform dose distribution. Conclusion: By applying the field-in-field technique, which takes into account beam divergence in radiation treatment planning, we could reduce cold spots and hot spots through the correction of dose on the junction and, in particular, we could correct under dose at the entry point resulting from beam divergence. This study suggests that the clinical application of the field-in-field technique may reduce the risk of lymph node metastasis caused by under dose on the cervical lymph node.

  • PDF

Evaluation of the accuracy of two different surgical guides in dental implantology: stereolithography fabricated vs. positioning device fabricated surgical guides (제작방법에 따른 임플란트 수술 가이드의 정확성비교: stereolithography와 positioning device로 제작한 수술 가이드)

  • Kwon, Chang-Ryeol;Choi, Byung-Ho;Jeong, Seung-Mi;Joo, Sang-Dong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.271-278
    • /
    • 2012
  • Purpose: Recently implant surgical guides were used for accurate and atraumatic operation. In this study, the accuracy of two different types of surgical guides, positioning device fabricated and stereolithography fabricated surgical guides, were evaluated in four different types of tooth loss models. Materials and methods: Surgical guides were fabricated with stereolithography and positioning device respectively. Implants were placed on 40 models using the two different types of surgical guides. The fitness of the surgical guides was evaluated by measuring the gap between the surgical guide and the model. The accuracy of surgical guide was evaluated on a pre- and post-surgical CT image fusion. Results: The gap between the surgical guide and the model was $1.4{\pm}0.3mm$ and $0.4{\pm}0.3mm$ for the stereolithography and positioning device surgical guide, respectively. The stereolithography showed mesiodistal angular deviation of $3.9{\pm}1.6^{\circ}$, buccolingual angular deviation of $2.7{\pm}1.5^{\circ}$ and vertical deviation of $1.9{\pm}0.9mm$, whereas the positioning device showed mesiodistal angular deviation of $0.7{\pm}0.3^{\circ}$, buccolingual angular deviation of $0.3{\pm}0.2^{\circ}$ and vertical deviation of $0.4{\pm}0.2mm$. The differences were statistically significant between the two groups (P<.05). Conclusion: The laboratory fabricated surgical guides using a positioning device allow implant placement more accurately than the stereolithography surgical guides in dental clinic.