Purpose : This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. Materials and Methods : 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Results : Effective doses in ${\mu}Sv$ ($E_{2007}$) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. Conclusion : From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.
Purpose: To longitudinally observe the healing process of extracted socket and the alterations of the residual ridge in healthy adult dogs using cone beam CT (CBCT). Materials and Methods: The mandibular premolars of two beagle dogs were removed and the extraction sites were covered with the gingival tissue. CBCTs (3D X-ray CT scanner, Alphard vega, Asahi Co.) were taken at baseline and at 1 week interval for 12 weeks. Radiographic density of extracted wounds was measured on normalized images with a custom-made image analysis program. The amount of alveolar crestal resorption after the teeth extraction was measured with a reformatted three-dimensional image using CBCT. Bony healing pattern of extracted wound of each group was also longitudinally observed and analyzed. Results: Dimensional changes occurred during the first 6 weeks following the extraction of dogs' mandibular premolars. The reduction of the height of residual ridge was more pronounced at the buccal than at the lingual aspect of the extraction socket. Radiographic density of extracted wounds increased by week 4, but the change in density stabilized after week 6. New bone formation was observed at the floor and the peripheral side of extracted socket from week 1. The entrance of extracted socket was sealed by a hard-tissue bridge at week 5. Conclusion: The healing process of extracted wound involved a series of events including new bone formation and residual ridge resorption.
Kim, Yoon Sang;Kim, In-Sung;Yoo, Yon-Sik;Jang, Seong-Wook;Yang, Cheol-Jung
Clinics in Shoulder and Elbow
/
제18권3호
/
pp.152-158
/
2015
Background: Acromioclavicular (AC) stability is maintained through a complex combination of soft-tissue restraints that include coracoclavicular (CC), AC ligament and overlying muscles. Among these structures, the role of the CC ligament has continued to be studied because of its importance on shoulder kinematics, especially after AC injury. This study was designed to determine the geometric change of conoid and trapezoid ligaments and resulting stresses on these ligaments according to various scapular motions. Methods: The scapuloclavicular (SC) complex was isolated from a fresh-frozen cadaver by removing all soft tissues except the AC and CC ligaments. The anatomically aligned SC complex was then scanned with a high-resolution computed tomography scanner into 0.6- mm slices. The Finite element model of the SC complex was obtained and used for calculating the stress on different parts of the CC ligaments with simulated movements of the scapula. Results: Average stress on the conoid ligament during anterior tilt, internal rotation, and scapular protraction was higher, whereas the stress on the trapezoid ligament was more prominent during posterior tilt, external rotation, and retraction. Conclusions: We conclude that CC ligament plays an integral role in regulating horizontal SC motion as well as complex motions indicated by increased stress over the ligament with an incremental scapular position change. The conoid ligament is the key structure restraining scapular protraction that might occur in high-grade AC dislocation. Hence in CC ligament reconstructions involving only single bundle, every attempt must be made to reconstruct conoid part of CC ligament as anatomically as possible.
Purpose: To determine the conversion coefficients (CCs) from the dose-area product (DAP) value to effective dose in cone-beam CT. Materials and Methods: A CBCT scanner with four fields of view (FOV) was used. Using two exposure settings of the adult standard and low dose exposure, DAP values were measured with a DAP meter in C mode ($200mm{\times}179mm$), P mode ($154mm{\times}154mm$), I mode ($102mm{\times}102mm$), and D mode ($51mm{\times}51mm$). The effective doses were also investigated at each mode using an adult male head and neck phantom and thermoluminescent chips. Linear regressive analysis of the DAP and effective dose values was used to calculate the CCs for each CBCT examination. Results: For the C mode, the P mode at the maxilla, and the P mode at the mandible, the CCs were 0.049 ${\mu}Sv/mGycm^2$, 0.067 ${\mu}Sv/mGycm^2$, and 0.064 ${\mu}Sv/mGycm^2$, respectively. For the I mode, the CCs at the maxilla and mandible were 0.076 ${\mu}Sv/mGycm^2$ and 0.095 ${\mu}Sv/mGycm^2$, respectively. For the D mode at the maxillary incisors, molars, and mandibular molars, the CCs were 0.038 ${\mu}Sv/mGycm^2$, 0.041 ${\mu}Sv/mGycm^2$, and 0.146 ${\mu}Sv/mGycm^2$, respectively. Conclusion: The CCs in one CBCT device with fixed 80 kV ranged from 0.038 ${\mu}Sv/mGycm^2$ to 0.146 ${\mu}Sv/mGycm^2$ according to the imaging modes and irradiated region and were highest for the D mode at the mandibular molar.
This study analyzed dose reduction and quality of images through dose reduction tools and shielding board to protect sensitive eye lens in radiation during orbit CT examinations for clinical data use. During CT scans of the phantom, surface dose (CT scanner dosimetry phantom, ion chamber-3 times) and quality of image (radiosurgery head phantom, visual assessment-2 times, HU standard deviation) were evaluated using X-care which is dose reduction tools and bismuth shielding board. The results of experiments of eight conditions showed a relatively reduced dose in all other conditions compared to when no conditions were set. In particular, the area corresponding to the ophthalmic part reduced the surface dose by up to 45.7 %. The visual evaluation of images by specialists and the quality evaluation of images analyzed by HU standard deviation were clinically closest to the use of X-care and shielding board (1 cm in height). Therefore, it is believed that the use of shielding board in a suitable location with dose reduction tools while investigating the optimal radiation dose will reduce the exposure dose of sensitive lens at radiation while maintaining the quality of the images with high diagnostic value.
June Park;Jaeseung Shin;In Kyung Min;Heejin Bae;Yeo-Eun Kim;Yong Eun Chung
Korean Journal of Radiology
/
제23권4호
/
pp.402-412
/
2022
Objective: To evaluate the image quality and lesion detectability of lower-dose CT (LDCT) of the abdomen and pelvis obtained using a deep learning image reconstruction (DLIR) algorithm compared with those of standard-dose CT (SDCT) images. Materials and Methods: This retrospective study included 123 patients (mean age ± standard deviation, 63 ± 11 years; male:female, 70:53) who underwent contrast-enhanced abdominopelvic LDCT between May and August 2020 and had prior SDCT obtained using the same CT scanner within a year. LDCT images were reconstructed with hybrid iterative reconstruction (h-IR) and DLIR at medium and high strengths (DLIR-M and DLIR-H), while SDCT images were reconstructed with h-IR. For quantitative image quality analysis, image noise, signal-to-noise ratio, and contrast-to-noise ratio were measured in the liver, muscle, and aorta. Among the three different LDCT reconstruction algorithms, the one showing the smallest difference in quantitative parameters from those of SDCT images was selected for qualitative image quality analysis and lesion detectability evaluation. For qualitative analysis, overall image quality, image noise, image sharpness, image texture, and lesion conspicuity were graded using a 5-point scale by two radiologists. Observer performance in focal liver lesion detection was evaluated by comparing the jackknife free-response receiver operating characteristic figures-of-merit (FOM). Results: LDCT (35.1% dose reduction compared with SDCT) images obtained using DLIR-M showed similar quantitative measures to those of SDCT with h-IR images. All qualitative parameters of LDCT with DLIR-M images but image texture were similar to or significantly better than those of SDCT with h-IR images. The lesion detectability on LDCT with DLIR-M images was not significantly different from that of SDCT with h-IR images (reader-averaged FOM, 0.887 vs. 0.874, respectively; p = 0.581). Conclusion: Overall image quality and detectability of focal liver lesions is preserved in contrast-enhanced abdominopelvic LDCT obtained with DLIR-M relative to those in SDCT with h-IR.
본 연구는 종합병원 내 응급실에 설치된 CT 장비와 일반촬영장비에 대한 세균 오염도 검사를 실시하여 보건학적 융복합 감염관리에 대한 기초자료를 마련하고자 하였다. 연구는 2015년 12월 1일부터 12월 31일까지 수도권 3곳과 전라도 2곳, 충청도 2곳 등 총 7곳의 의료기관을 대상으로하였다. 영상의학과 응급실 내 CT장비의 검출된 표면 오염 균주는 Micrococcus species(4,5%), Stenotrophomonas maltophilia(9%), Enteococcus faecium(4.5%), Providencia stuartii(4.5), Gram negative bacilli(4.5%), 일반촬영장비에서 검출된 표면 오염 균주는 Providencia stuartii(11%), Klebsiella pneumonia(3.5%), Stenotrophomonas maltophilia(11%), Pantoea species(11%), Acinetobacter baumannii(3.5%), Micrococcus species(3.5%), Escherichia coli(3.5%), Enterobacter species(3.5%), Gram negative bacilli(11%) 로 병원 감염의 원인균으로 알려진 균주는 없었고, 특이성을 가진 균주 역시 없었지만 가장 많이 검출된 구역이 모두 환자와 밀접한 관련을 갖는 곳이므로 방사선사는 검사 전후 알코올 등으로 깨끗이 닦아내야 할 것이다.
목적 : 자체 제작한 Q.A tool을 이용하여 AAPM Task Group Report No.66 에서 제시하는 CT simulator의 Q.A 항목을 확인하여 보다 안전하고 정확한 CT-simulation 과정을 확보하기 위해 효율적이고 편리성을 갖춘 정도관리 과정을 제시하고자 한다. 대상 및 방법 : 본원에 CT simulator의 Q.A tool을 제작하여 Report of the AAPM Task Group No.66에서 제시하는 wall laser system, patient table, CT scanner의 imaging plane의 isocenter간의 정렬을 일간 단위로 확인한다. 결과 : Report of the AAPM Task Group No.66에서 제시하고 있는 정도관리 항목의 확인으로 wall laser의 ${\pm}\;2mm$, table의 ${\pm}\;2mm$, imaging plane의 ${\pm}\;2mm$ 허용 오차 범위내의 측정치를 확인하였다. 결론 : 방사선 치료을 위한 CT-simulation 과정에서 기존의 진단 영역의 CT Q.A protocol로는 확인되지 않는 항목이 있는데, Report of the AAPM Task Group No.66에서 제시하고 있는 Q.A 항목을 확인하여 방사선 치료전용 CT-simulator 장비의 적절한 정도 관리를 기하여 안전하고 정확한 CT-simulation 과정을 보장받을 수 있었다.
Purpose: Computed tomography theoretically should improve detection of foreign bodies and provide more information of adjacent soft tissues. And the CT scanner and PACS program proved to be an excellent instrument for detection and localization of most facial foreign bodies above certain minimum levels of detectability. The severity of injury in penetrating trauma to the face, it is often underestimated by physical examination. Diagnosis of a retained foreign object is always critical. Methods: From March, 2005 to February 2008 a study was done with 200 patients who had facial trauma. Axial and coronal CT images were obtained with a General Electric(Milwaukee, Wis) 9800 CT scanner at 130 kV, 90 mA, with a 2-mm section thickness and a $512{\times}512$ matrix. Results: Axial and coronal CT images at various window widths should be used as the first imaging modality to detect facial foreign bodies. The attenuation coefficients for the metallic and nonmetallic foreign bodies ranged from -437 to +3071 HU. As a general rule, metallic foreign bodies produced more Hounsfield artifacts than nonmetallic foreign bodies, thus providing a clue to their composition. All of the metallic foreign bodies were represented by a single peak and had a maximum attenuation coefficient of +3071 HU. Of the nonmetallic foreign bodies, glass had an attenuation coefficient that ranged from +105 to +2039, while plastic had a much lower coefficient that ranged from -62 to -35. wood had the lowest range of attenuation coefficients: -491 to -437. Conclusion: The PACS program allows one to distinguish metallic from nonmetallic foreign bodies and to individually identify the specific composition of many nonmetallic foreign bodies. This program does not, however, allow identification of the specific composition of a metallic foreign body. We recommend this type of software program for CT scanning of any patient with an injury to the face in which a foreign body is suspected.
신장의 기능을 정량분석 할 수 있는 $^{99m}Tc$-DMSA 평면 영상은 단층영상에 비해 병소의 위치 정보에 한계가 있다. 따라서 광자 신호에 민감한 범용성 collimator로 교체하여 SPECT 방식으로 임상실험을 시행한 후, 진단의 정확도와 검사 소요시간을 분석하여 임상적용 가능성을 평가하였다. 10명의 실험대상에게 방사성의약품(1.0-1.2 MBq/kg)을 정맥주사하고, 이중 검출기 감마카메라를 이용하여 planar scan (high resolution (HR)-mode, $256{\times}256$, 50 kcts/view, 4 image)과 SPECT (HR / high sensitive (HS)-mode, $128{\times}128$, step and shoot, $180^{\circ}$, variable sec/angle, total 64 frame, OSEM reconstruction)를 시행하였다. 획득한 데이터를 분석 프로그램을 이용하여 비교한 결과, 실험 방법에 따라서 total counts는 high sensitive-mode SPECT가 대략 1.8-5.6 배 정도 많았고, counts를 이용한 상대신장기능은 모든 실험에서 유의한 수준 범위에서 차이가 없었으며(p=0.96), 검사 소요시간은 39%정도 단축되었다. 그러므로 고감도 범용성 collimator를 이용한 $^{99m}Tc$-DMSA renal SPECT는 planar scan에 비하여 신장의 기능을 정량분석 할 수 있고, 병변의 위치에 대한 정보를 보다 정확하게 진단할 수 있으며, 동시에 검사 소요시간을 단축시킬 수 있으므로 임상적으로 유용하게 활용할 수 있을 것으로 사료된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.