• 제목/요약/키워드: Computed Tomography Fluoroscopy

검색결과 41건 처리시간 0.023초

Accuracy of Pedicle Screw Insertion Using Fluoroscopy-Based Navigation-Assisted Surgery : Computed Tomography Postoperative Assessment in 96 Consecutive Patients

  • Lee, Keong Duk;Lyo, In Uk;Kang, Byeong Seong;Sim, Hong Bo;Kwon, Soon Chan;Park, Eun Suk
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권1호
    • /
    • pp.16-20
    • /
    • 2014
  • Objective : Two-dimensional fluoroscopy-based computerized navigation for the placement of pedicle screws offers the advantage of using stored patient-specific imaging data in providing real-time guidance during screw placement. The study aimed to describe the accuracy and reliability of a fluoroscopy-based navigation system for pedicle screw insertion. Methods : A total of 477 pedicle screws were inserted in the lower back of 96 consecutive patients between October 2007 and June 2012 using fluoroscopy-based computer-assisted surgery. The accuracy of screw placement was evaluated using a sophisticated computed tomography protocol. Results : Of the 477 pedicle screws, 461 (96.7%) were judged to be inserted correctly. Frank screw misplacement [16 screws (3.3%)] was observed in 15 patients. Of these, 8 were classified as minimally misplaced (${\leq}2mm$); 3, as moderately misplaced (2.1-4 mm); and 5, as severely misplaced (>4 mm). No complications, including nerve root injury, cerebrospinal fluid leakage, or internal organ injury, were observed in any of the patients. Conclusion : The accuracy of pedicle screw placement using a fluoroscopy-based computer navigation system was observed to be superior to that obtained with conventional techniques.

Computed Tomography Fluoroscopy-Guided Selective Nerve Root Block for Acute Cervical Disc Herniation

  • Eun, Sang-Soo;Chang, Won-Sok;Bae, Sang-Jin;Lee, Sang-Ho;Lee, Dong-Yeob
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권5호
    • /
    • pp.419-422
    • /
    • 2010
  • Objective : To analyze the clinical outcomes of computed tomography (CT) fluoroscopy-guided selective neve root block (SNRB) for severe arm pain caused by acute cervical disc herniation. Methods : The authors analyzed the data obtained from 25 consecutive patients who underwent CT fluoroscopy-guided SNRB for severe arm pain, i.e., a visual analogue scale (VAS) score of 8 points or more, caused by acute soft cervical disc herniation. Patients with chronic arm pain, motor weakness, and/or hard disc herniation were excluded. Results : The series comprised 19 men and 6 women whose mean age was 48.1 years (range 35-72 years). The mean symptom duration was 17.5 days (range 4-56 days) and the treated level was at C5-6 in 13 patients, C6-7 in 9, and both C5-6 and C6-7 in 3. Twenty-three patients underwent SNRB in 1 session and 2 underwent the procedure in 2 sessions. No complications related to the procedures occurred. At a mean follow-up duration of 11.5 months (range 6-22 months), the mean VAS score and NDI significantly improved from 9 and 58.2 to 3.4 and 28.1, respectively. Eighteen out of 25 patients (72%) showed successful clinical results. Seven patients (28%) did not improve after the procedure, and 5 of these 7 underwent subsequent anterior cervical discectomy and fusion. Conclusion : CT fluoroscopy-guided SNRB may play a role as a primary conservative treatment for severe arm pain caused by acute cervical disc herniation.

월경성 각혈 - 1예 보고 - (Catamenial Hemoptysis - Report of one case -)

  • 곽영태;맹대현;배철영;이신영;김정숙;이혁표
    • Journal of Chest Surgery
    • /
    • 제33권7호
    • /
    • pp.597-600
    • /
    • 2000
  • 폐실질에 발생하는 자궁내막증은 월경시마다 반복되는 특징적인 증상을 갖는 드문 질환이다. 저자는 유산 및 출산 경험이 없는 3개월의 월경성 각혈의 증상을 가진 19세의 여자 환자를 흉부 전산화 단층촬영으로 확진 하였으며 우측 병변은 흉강경을 이용한 쐐기 절제술, 연이어 좌측 병변은 개흉술을 통한 상분엽절제술을 시행하였다. 수술 전에 시행하였던 투시경(fluoroscopy) 도음하의 hooking이 일측폐 마취에서의 병변의 확인에 도움을 주었다.

  • PDF

초음파를 활용한 하지와 체간부위의 신경차단술 (Ultrasound Guided Nerve Block at Vertebra and Lower Extremity)

  • 박형규
    • Clinical Pain
    • /
    • 제20권2호
    • /
    • pp.93-98
    • /
    • 2021
  • The use of ultrasonography has recently been increasing in musculoskeletal diagnosis or intervention treatment. Ultrasound guided procedure offers a reliable alternative to fluoroscopy or computed tomography for lumbar medial branch block, facet joint block and peripheral nerves of lower extremity. Further, there is no exposure to radiation and additional equipment necessary for the protection against radiation is required. And ultrasound guided procedure needs smaller space than fluoroscopy guided procedure with real time images in the outpatient department. This article reviews ultrasound guided procedure at lumbar vertebra and peripheral nerves of lower extremity.

Computed Tomography (CT) Simulated Fluoroscopy-Guided Transdiscal Approach in Transcrural Celiac Plexus Block

  • Kong, Yu Gyeong;Shin, Jin Woo;Leem, Jeong Gill;Suh, Jeong Hun
    • The Korean Journal of Pain
    • /
    • 제26권4호
    • /
    • pp.396-400
    • /
    • 2013
  • Conventional transcrural CPB via the "walking off" the vertebra technique may injure vital organs while attempting to proximally spread injectate around the celiac plexus. Therefore, we attempted the CT-simulated fluoroscopy-guided transdiscal approach to carry out transcrural CPB in a safer manner, spreading the injectate more completely and closely within the celiac plexus area. A 54-year-old male patient with pancreatic cancer suffered from severe epigastric pain. The conventional transcrural approach was simulated, but the needle pathway was impeded by the kidney on the right side and by the aorta on the left side. After simulating the transdiscal pathway through the T11-12 intervertebral disc, we predetermined the optimal insertion point (3.6 cm from the midline), insertion angle (18 degrees), and advancement plane, as well as the proper depth. With the transdiscal approach, we successfully performed transcrural CPB within a narrow angle, and the bilateral approach was not necessary as we were able to achieve the bilateral spread of the injectate with the single approach.

Measurement of S1 foramen depth for ultrasound-guided S1 transforaminal epidural injection

  • Ye Sull Kim;SeongOk Park;Chanhong Lee;Sang-Kyi Lee;A Ram Doo;Ji-Seon Son
    • The Korean Journal of Pain
    • /
    • 제36권1호
    • /
    • pp.98-105
    • /
    • 2023
  • Background: Ultrasound-guided first sacral transforaminal epidural steroid injection (S1 TFESI) is a useful and easily applicable alternative to fluoroscopy or computed tomography (CT) in lumbosacral radiculopathy. When a needle approach is used, poor visualization of the needle tip reduces the accuracy of the procedure, increasing its difficulty. This study aimed to improve ultrasound-guided S1 TFESI by evaluating radiological S1 posterior foramen data obtained using three-dimensional CT (3D-CT). Methods: Axial 3D-CT images of the pelvis were retrospectively analyzed. The radiological measurements obtained from the images included 1st posterior sacral foramen depth (S1D, mm), 1st posterior sacral foramen width (S1W, mm), the angle of the 1st posterior sacral foramen (S1A, °), and 1st posterior sacral foramen distance (S1ds, mm). The relationship between the demographic factors and measured values were then analyzed. Results: A total of 632 patients (287 male and 345 female) were examined. The mean S1D values for males and females were 11.9 ± 1.9 mm and 10.6 ± 1.8 mm, respectively (P < 0.001); the mean S1A 28.2 ± 4.8° and 30.1 ± 4.9°, respectively (P < 0.001); and the mean S1ds, 24.1 ± 2.9 mm and 22.9 ± 2.6 mm, respectively (P < 0.001); however, the mean S1W values were not significantly different. Height was the only significant predictor of S1D (β = 0.318, P = 0.004). Conclusions: Ultrasound-guided S1 TFESI performance and safety may be improved with adjustment of needle insertion depth congruent with the patient's height.

Comparative Analysis of Surgical Outcomes of C1-2 Fusion Spine Surgery between Intraoperative Computed Tomography Image Based Navigation-Guided Operation and Fluoroscopy-Guided Operation

  • Lee, Jun Seok;Son, Dong Wuk;Lee, Su Hun;Ki, Sung Soon;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권2호
    • /
    • pp.237-247
    • /
    • 2020
  • Objective : Fixation of the C1-2 segment is challenging because of the complex anatomy in the region and the need for a high degree of accuracy to avoid complications. Preoperative 3D-computed tomography (CT) scans can help reduce the risk of complications in the vertebral artery, spinal cord, and nerve roots. However, the patient may be susceptible to injury if the patient's anatomy does not match the preoperative CT scans. The intraoperative 3D image-based navigation systems have reduced complications in instrument-assisted techniques due to greater accuracy. This study aimed to compare the radiologic outcomes of C1-2 fusion surgery between intraoperative CT image-guided operation and fluoroscopy-guided operation. Methods : We retrospectively reviewed the radiologic images of 34 patients who underwent C1-2 fusion spine surgery from January 2009 to November 2018 at our hospital. We assessed 17 cases each of degenerative cervical disease and trauma in a study population of 18 males and 16 females. The mean age was 54.8 years. A total of 139 screws were used and the surgical procedures included 68 screws in the C1 lateral mass, 58 screws in C2 pedicle, nine screws in C2 lamina and C2 pars screws, four lateral mass screws in sub-axial level. Of the 34 patients, 19 patients underwent screw insertion using intraoperative mobile CT. Other patients underwent atlantoaxial fusion with a standard fluoroscopy-guided device. Results : A total of 139 screws were correctly positioned. We analyzed the positions of 135 screws except for the four screws that performed the lateral mass screws in C3 vertebra. Minor screw penetration was observed in seven cases (5.2%), and major pedicle screw penetration was observed in three cases (2.2%). In one case, the malposition of a C2 pedicle screw was confirmed, which was subsequently corrected. There were no complications regarding vertebral artery injury or onset of new neurologic deficits. The screw malposition rate was lower (5.3%) in patients who underwent intraoperative CT-based navigation than that for fluoroscopy-guided cases (10.2%). And we confirmed that the operation time can be significantly reduced by surgery using intraoperative O-arm device. Conclusion : Spinal navigation using intraoperative cone-beam CT scans is reliable for posterior fixation in unstable C1-2 pathologies and can be reduced the operative time.

요추부 초음파 유도하 중재술 (Ultrasound-guided Intervention in Lumbar Spine)

  • 문상호
    • 대한정형외과 초음파학회지
    • /
    • 제6권2호
    • /
    • pp.81-93
    • /
    • 2013
  • 본 종설에서는 요추부 중재술에 있어서 초음파라는 장비가 영상 장치로서 얼마나 유용한가에 대해 기술하였다. 우선 요천추부의 표면 해부학과 초음파 해부학에 대하여 기술하였는데, 이는 초음파 유도하 중재술에서 영상의 판독과 술기의 수행에 있어 해부학의 자세한 이해가 반드시 필요하기 때문이다. 방사선 투시하에 척추 중재술을 하는 것이 보편화 되어 있지만 방사선을 피폭해야 하는 문제가 늘 존재한다. 초음파는 방사선이 없고 간편하며 높은 정확도로 실시간 영상을 제공하는 장점들이 있으며 어떠한 임상 환경적 조건에서도 시행할 수 있다. 초음파 유도하 요추부 중재술은 방사선 투시기나 컴퓨터 단층촬영 유도로 시행하였던 기존의 방식을 대신할 수 있으며 방사선 피폭 없이 안전하게 시행할 수 있는 방법이다.

  • PDF

응급 인터벤션 영상의학에서 가상 투시영상 검사의 유용성 (Usefulness of Virtual Fluoroscopy in Emergency Interventional Radiology)

  • Yoshihiro Tanaka;Akitoshi Oosone;Asuka Tsuchiya
    • 대한영상의학회지
    • /
    • 제81권4호
    • /
    • pp.852-862
    • /
    • 2020
  • 인터벤션 색전술은 영상 유도하에 카테터를 출혈 부위에 위치하고, 젤폼 또는 코일 등의 색전 물질을 사용해서 출혈을 막는다. 의인성 외상을 치료하는 것 이외에, 수술이 불가능한 간 및 신장의 출혈(blush-bleeding) 및 혈관 손상을 진단하고 치료하는 데에 유용하다. 그러나 병원 일과 시간이 아닌 경우, 숙련된 인터벤션 의료팀이 항상 준비되어 있지는 않다. 이러한 상황에서 인터벤션 팀의 협업은 심각한 손상을 입은 환자를 빠르게 치료하는데 꼭 필요하다. 이 논문은 가상 투시장비 검사의 유용성에 대한 현재의 원칙과 기술을 검토하고 응급 인터벤션 시술에서 유용한 사례들을 제시하고자 한다.

미만성 침윤성 폐질환을 보이는 환자에서 방사선투시유도 절단침 폐생검의 유효성 (Efficacy of Fluoroscopy-Guided Cutting Needle Lung Biopsy in Patients with Diffuse Infiltrative Lung Disease)

  • 최수전;신은아;김정숙
    • Tuberculosis and Respiratory Diseases
    • /
    • 제70권1호
    • /
    • pp.43-50
    • /
    • 2011
  • Background: Open lung biopsy is used for diagnosis of diffuse infiltrative lung diseases (DILD), but it is invasive and relatively expensive procedure. Fluoroscopy-guided cutting needle lung biopsy (FCNLB) has merits of avoidance of admission and rapid diagnosis. But diagnostic accuracy and safety were not well known in the diagnosis of DILD. Methods: We included 52 patients (37 men, 15 women) having DILD on HRCT with dyspnea, except the patients who could be confidently diagnosed with clinical and HRCT findings. FCNLB was performed using 16G Ace cut needle (length 1.5 cm, diameter 2 mm) at the area of most active lesion on HRCT. Final diagnoses were made by the consensus. Results: The mean interval between the HRCT and FCNLB was 4.5 days. Most cases were performed one biopsy during 5~10 minutes. Specific diagnosis was obtained in 43 of 52 biopsies (83%). The most common diagnosis was nonspecific interstitial pneumonia (11 cases) and followed by cryptogenic organizing pneumonia (7 cases), diffuse alveolar hemorrhage and usual interstitial pneumonia (5 cases in each), hypersensitivity pneumonitis (3 cases), tuberculosis and drug induced interstitial pneumonitis (2 cases in each), the others are in one respectively. Mild complication was developed in 9 patients (8 pneumothorax, 1 hemoptysis). Most of complications were regressed without treatment except one case with chest tube insertion for pneumothorax. Conclusion: Fluoroscopy-guided 16 G cutting needle lung biopsy was an useful method for the diagnosis of DILD.