• Title/Summary/Keyword: Compression load

Search Result 1,361, Processing Time 0.033 seconds

Buckling load optimization of laminated composite stepped columns

  • Topal, Umut
    • Structural Engineering and Mechanics
    • /
    • v.62 no.1
    • /
    • pp.107-111
    • /
    • 2017
  • This paper deals with critical buckling load optimization of symmetric angle-ply laminated stepped flat columns under axial compression load. The design objective is the maximization of the critical buckling load and the design variable is the fiber orientations in the layers of the laminates. The classical laminate plate theory is used for the finite element solution of the laminated stepped flat columns. The modified feasible direction (MFD) method is used for the optimization routine. For this purpose, a program based on FORTRAN is exploited. Finally, the optimization results are presented for width ratios (b/B), ratios of fillet radius ($r_1/r_2$), aspect ratios (L/B) and boundary conditions. The results are presented in graphical and tabular forms and the results are compared.

A study on the part-load performance of 2-stage water source heat pump (2단 압축 수열원 열펌프 시스템의 부분부하 운전특성에 관한 연구)

  • Lee, Young-Soo;Baik, Young-Jin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.5 no.1
    • /
    • pp.13-17
    • /
    • 2009
  • The river water heat source heat pump has the advantage in the performance compared to air source heat pump. In this study, an experimental study on a 2-stage heat pump, which is designed to utilize a river water heat source, were carried out. Generally, a heat pump is designed for maximum capacity rate, but it actually operates at part load condition in most cases. Therefore, an information on the part-load characteristic is very important in view of the system overall performance. In this study, part-load performance tests of a R134a 2-stage compression heat pump were carried out over the river water and supply heating water temperature changes.

  • PDF

Evaluation of Limit Load of Granular Pavement Materials Considering Unsaturated Shear Strength Characteristics (불포화 강도특성을 고려한 도로 입상재료의 한계하중 평가)

  • Jeon, Hye-Ji;Park, Seong-Wan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.673-678
    • /
    • 2010
  • In this paper, the limit load of granular materials was evaluated considering unsaturated shear strength. The unsaturated shear strength parameters were estimated using the results from triaxial compression test and soil-water characteristic curves test. In addition, the limit load of different rates of materials was compared. Also, two important design parameters, yield and failure load were defined utilizing 2-D nonlinear finite element analysis respectively.

  • PDF

Design Approach of Large-scale Experimental Facilities Reflect the Load Flow (하중흐름을 통한 대형구조실험용 반력시설물의 설계)

  • Lee, Sung-Eun;Ko, Dong-Woo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.2
    • /
    • pp.69-77
    • /
    • 2016
  • The purpose of this study is to present a method that can estimate the height of reaction facilities for large structural experiment through load flow as primary design procedure. The characteristic of the load transmission according to the type of experiment was analyzed to obtain tensile and compressive forces occurring on the reaction facilities. Strong walls that are affected by the bending moment is applied the post-tensioning method, and the strong floor under the control of the tension and compression is designed in accordance with the load flow. And the optimum cross-section of the reaction facilities was obtained by comparing the stresses of the tensile stress and crack the concrete. Through validating elastic analysis, the design results were satisfied a given design conditions.

Confining Effect of CFS on Concrete Compressive Members under Load Actions (하중이력에 따른 콘크리트 압축부재의 CFS 보강효과에 관한 연구)

  • 배주성;김경수;김재욱;고영표
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.705-708
    • /
    • 1999
  • Advanced composite materials such as carbon fiber, aramid, and glass fiber sheet, are widely used recently to strengthening existing reinforced concrete structures. The purpose of this paper was to investigate the mechanical characteristics of concrete compressive members confined with carbon fiber sheet and evaluate the efficiency of the strengthening under load actions. Uniaxal compression tests of concrete compressive members confined with carbon fiber sheet were experimentally used to develop a relationship between the axial stresses and the lateral stresses. The resulting axial and lateral strains were used to determine the confinement effect of concrete compressive members.

  • PDF

Quantitative Analysis of Hot Forming with Stress Compensation to Dynamic Recrystallization (고온성형중 동적재결정에 의한 하중감소의 정략적 해석)

  • 장영원
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.03b
    • /
    • pp.203-206
    • /
    • 1999
  • The shift of flow behavior due to dynamic recrystallization during hot forming process is investigated, A series of load relaxation and compression tests has been conducted at various temperatures Constitutive relations and recrystallization behaviors were formulated from the mechanical test results, The consideration of dynamic recrystallization during a specific forming process was implemented to commercial FEM package by conditioned remeshing and remapping of state variables. Improvement of Load-Stroke prediction was validated by comparison with experimental results.

  • PDF

Compressive behavior of short fibrous reinforced concrete members with square cross-section

  • Campione, G.
    • Structural Engineering and Mechanics
    • /
    • v.37 no.6
    • /
    • pp.649-669
    • /
    • 2011
  • In this paper an analytical model is presented that addresses the compressive response of short-fiber reinforced concrete members (FRC) with hooked steel fibers. This model is applicable to a wide range of concrete strengths and accounts for the interaction between the cover spalling and the concrete core confinement induced by transverse steel stirrups and also for buckling of longitudinal reinforcing bars. The load-shortening curves generated here analytically fit existing experimental data well.

The Crushing Behaviour of Thin Plates Subjected to Compression -Ultimate Load and Energy Absorption-

  • Jae-Wook,Lee
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.19 no.1
    • /
    • pp.33-39
    • /
    • 1982
  • An experimental investigation on the ultimate load and energy absorption of thin plates is presented, which enables the damage to ship involved in a collision to be estimated in terms of the lost kinetic energy. The derived formulae are based upon experimental analysis and compared with theoretical presentations published by some authors. A relationship is found between the absorbed energy and the volume of damaged steel plates.

  • PDF

An Experimental Study on Eccentrically Loaded Steel Fiber Reinforced Concrete Columns (편심축하중을 받는 강섬유보강 콘크리트 기둥의 실험적 연구)

  • 박홍용;안영진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.857-860
    • /
    • 2000
  • An experimental study on the behavior of Steel Fiber Reinforced Concrete Columns under eccentric compression are presented. Forth-one columns were tested; the variables were column type, eccentricity of load, fiber contents, and longitudinal reinforcement ratio. The column size was $250\times160$ mm in cross section with an effective length of 1150 mm. Eccentricity of load was varied in the range from 1/6 to 1/2 times the column depth. This paper is to provides a framework for basic understanding of the steel fiber concrete columns.

Pullout Capacity of Ground Anchors in Weathered Soil (풍화토 지반에 설치된 앵커의 인발 특성)

  • 김낙경
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.4
    • /
    • pp.231-239
    • /
    • 2001
  • 건설 현장에서 널리 사용되고 있는 그라운드 앵커의 거동 특성을 연구하기 위하여 계측기를 부착한 일곱 개의 그라운드 앵커를 국내에 널리 분포되어 있는 화강 풍화토 지반인 $\bigcirc$$\bigcirc$$\bigcirc$대학교 지반 시험장에 설치하여 인발 시험을 수행하였다. 저압 그라우트 인장형 앵커 3개와 압축형 앵커 4개를 시험하였고, 시험은 AASHTO 규정에 의거한 인발시험, 크리프시험, 장기거동시험을 수행하였다. 시험 결과로부터 화강 풍화토 지반에 설치된 저압그라우트 직선형 앵커의 지반과의 마찰계수, 크리프 변형율, 하중감소 특성을 평가하였다.

  • PDF