Effects of particle size and loading rate on the tensile failure of asphalt specimens based on a direct tensile test and particle flow code simulation

  • Q. Wang;D.C. Wang;J.W. Fu;Vahab Sarfarazi;Hadi Haeri;C.L. Guo;L.J. Sun;Mohammad Fatehi Marji
    • Structural Engineering and Mechanics
    • /
    • 제86권5호
    • /
    • pp.607-619
    • /
    • 2023
  • This study, it was tried to evaluate the asphalt behavior under tensile loading conditions through indirect Brazilian and direct tensile tests, experimentally and numerically. This paper is important from two points of view. The first one, a new test method was developed for the determination of the direct tensile strength of asphalt and its difference was obtained from the indirect test method. The second one, the effects of particle size and loading rate have been cleared on the tensile fracture mechanism. The experimental direct tensile strength of the asphalt specimens was measured in the laboratory using the compression-to-tensile load converting (CTLC) device. Some special types of asphalt specimens were prepared in the form of slabs with a central hole. The CTLC device is then equipped with this specimen and placed in the universal testing machine. Then, the direct tensile strength of asphalt specimens with different sizes of ingredients can be measured at different loading rates in the laboratory. The particle flow code (PFC) was used to numerically simulate the direct tensile strength test of asphalt samples. This numerical modeling technique is based on the versatile discrete element method (DEM). Three different particle diameters were chosen and were tested under three different loading rates. The results show that when the loading rate was 0.016 mm/sec, two tensile cracks were initiated from the left and right of the hole and propagated perpendicular to the loading axis till coalescence to the model boundary. When the loading rate was 0.032 mm/sec, two tensile cracks were initiated from the left and right of the hole and propagated perpendicular to the loading axis. The branching occurs in these cracks. This shows that the crack propagation is under quasi-static conditions. When the loading rate was 0.064 mm/sec, mixed tensile and shear cracks were initiated below the loading walls and branching occurred in these cracks. This shows that the crack propagation is under dynamic conditions. The loading rate increases and the tensile strength increases. Because all defects mobilized under a low loading rate and this led to decreasing the tensile strength. The experimental results for the direct tensile strengths of asphalt specimens of different ingredients were in good accordance with their corresponding results approximated by DEM software.

인장 좌굴 현상을 수반하는 음의 포아송 효과를 가지는 구조물 해석을 위한 비선형 트러스 유한요소 모델 (A Nonlinear Truss Finite Element Model for Structures with Negative Poisson Effect Accompanied by Tensile Buckling)

  • 김태완;김준식
    • 한국전산구조공학회논문집
    • /
    • 제36권3호
    • /
    • pp.193-201
    • /
    • 2023
  • 본 논문에서는 인장 좌굴 현상을 소개하고 이를 이용한 음의 포아송 효과를 가지는 구조물에 대한 분석을 다룬다. 일반적으로 널리 알려진 좌굴은 압축하중 하에서의 안정성 문제임에 반하여, 인장 좌굴은 인장에 의해 국소적으로 압축력이 생겨 발생하는 좌굴이다. 고전적인 좌굴에 비하여 비교적 최근의 연구이기 때문에 상대적으로 잘 알려지지 않았다. 이에 인장 좌굴 현상을 에너지 관점에서 고찰하고, 해석을 위하여 비틀림 스프링을 가지는 비선형 트러스 유한요소의 정식화를 수행하였다. 비선형해석을 통해 후좌굴 거동을 분석하고 비틀림 스프링이 주요 인자임을 확인하였다. 이러한 후좌굴 거동은 음의 포아송 비를 가지는 구조물에 적용할 수 있으며, 기계적 스위치 등의 장치에 적용할 가능성을 보였다. 얻어진 결과들의 정확성 확인을 위하여 해석해와 상용 유한요소해석 결과들과 비교하여, 개발된 유한요소 모델이 기초 설계에 유용함을 보였다.

수치해석을 이용한 강관합성말뚝의 보강효과 분석 (I) - 재료 강도 - (Analysis of Reinforcement Effect of Steel-Concrete Composite Piles by Numerical Analysis (I) - Material Strength -)

  • 김성렬;이주형;박재현;정문경
    • 대한토목학회논문집
    • /
    • 제29권6C호
    • /
    • pp.259-266
    • /
    • 2009
  • 강관합성말뚝의 강관은 내부 콘크리트의 변형을 억제하여 말뚝강도를 증가시키고 연성파괴를 유도하는 보강효과를 발휘한다. 본 연구에서는 강관, 콘크리트, 강관합성 시험체에 대하여 수행된 압축재하 실험의 하중-변위 곡선을 모사할 수 있는 해석모델 및 입력물성값을 분석하였다. 그 결과, 강관은 von-Mises 모델, 그리고 콘크리트는 소성변형률에 따라 점착력과 팽창각을 감소시키는 변형률 연화모델을 적용하여 실험결과를 모사하였다. 또한, 콘크리트 내부의 철근은 항복 모멘트 적용 및 철근의 단면적을 감소시켜 모사하였다. 본 연구에서 적용된 해석기법은 실험결과와 비교하여 강관합성말뚝의 항복거동 및 보강효과를 잘 모사할 수 있는 것으로 나타났다. 실물크기 말뚝에 대한 변수연구를 수행한 결과, 강관 합성말뚝의 재료강도는 강관의 보강효과에 의해 축방향에 대해 약 10%, 횡방향에 대해 약 20~45% 증가하는 것으로 나타났다.

중력식 항만구조물의 사석마운드 지반반력 평가식의 일반화 (Generalization of an Evaluation Formula for Bearing Pressures on the Rubble Mound of Gravity-Based Harbor Structures)

  • 박우선
    • 한국해안·해양공학회논문집
    • /
    • 제35권6호
    • /
    • pp.128-137
    • /
    • 2023
  • 본 연구는 비정형 바닥판을 갖는 중력식 구조물의 사석마운드 지반반력을 대상으로 하였다. 구조물 바닥을 강체로 가정하고, 사석마운드는 압축에 대해서만 저항하는 바닥에 균일하게 분포하는 선형스프링으로 모형화하여 지반반력 산정식을 유도하였다. 바닥 형상이 사각형인 경우, 그 유도된 식이 설계에 사용되고 있는 식으로 변환됨을 보임으로써 유도 과정에 오류가 없음을 확인하였다. 또한, 비정형 바닥 형상이 사각형으로 수렴할 때의 지반반력의 거동과 그 수렴값을 살펴봄으로써 유도된 식의 타당성을 입증하였다. 실제 설계에서 사용되고 있는 방법의 적정성을 살펴보기 위하여 기 설계된 방파제 단면에 대한 단부 지반반력을 계산하고 설계서에 제시된 값과 비교하였다. 그 결과, 설계에 사용한 방법이 비안전측의 결과를 주었다는 것을 확인하였다. 특히, 극한 설계조건의 경우와 같이 연직하중의 편심이 큰 경우에 그 차이가 더 크게 나타났다.

현사시나무로 제조(製造)된 열압축목재(熱壓縮木材)와 목재(木材)-고분자(高分子) 복합체(複合體) 재질(材質)의 비교연구(比較硏究) (Comparative Study on Mechanical Properties and Dimensional Stability of Staypak and Wood-Polymer Composites from Populus alba × P. Glandulosa wood)

  • 박상범;안원영
    • Journal of the Korean Wood Science and Technology
    • /
    • 제13권2호
    • /
    • pp.14-34
    • /
    • 1985
  • 본(本) 연구(硏究)에서는 국내산(國內産) 미이용(未利用) 활엽수재(闊葉樹材)인 현사시나무의 재질개량(材質改良)을 위한 방안(方案)으로 비닐계 단량체(單量體)인 methylmethacrylate (MMA) 용액(溶液)을 목재내(木材內)로 주입(注入)한 후(後) 가압(加壓) 가열(加熱) 촉매중합법(觸媒重合法)에 의하여 제조(製造)한 목재(木材)-고분자(高分子) 복합체(複合體)(WPC ; wood-polymer composites)와 열압축목재(熱壓縮木材) (Staypak ; heat-stabilized compressed wood)의 물리적(物理的), 기계적(機械的) 성질(性質)과 치수 안정성(安定性)을 조사(調査)하였다. WPC 제조시(製造時) 단량체(單量體)의 주입량(注入量)을 비교(比較)하기 위하여 침지법(浸漬法)과 진공감압법(眞空減壓法)을 실시(實施)하였다. 본(本) 연구(硏究)에서 얻어진 결과(結果)는 다음과 같다. 1. 목재내(木材內) 단량체(單量體)의 주입량(注入量)은 진공감압법(眞空減壓法)이 침지법(浸漬法)에 비(比)해 약(約) 2배(培)의 효과(效果)가 있었다. 2. 목재내(木材內)로 주입(注入)된 단량체(單量體)는 WPC 제조시(製造時) 약(約) 절반가량 중합(重合)되었다. 3. 제조(製造)된 WPC의 치수 안정효과(安定效果)의 측정결과(測定結果), 반경방향(半徑方向)에서의 항수축율(抗收縮率) 12.5~13.6%, 접선방향(接線方向)에서의 항수축율(抗收縮率)은 12.5~13.6%, 접선방향(接線方向)이 17.18~40.14%였다. 흡수감소율(吸收減少率)은 8.19~15.5%로 진공감압법(眞空減壓法)이 침지법(浸漬法)에 의(依)한 WPC보다 효과(效果)가 좋았다. 4. 휨강도(强度) 시험시(試險時) 하중(荷重)을 가(加)하는 방향(方向)을 달리하였을 때 반경방향(半徑方向)으로 하중(荷重)을 가(加)한 경우(境遇)가 접선방향(接線方向)에 비(比)해 높은 강도치(强度値)를 나타내었다. 5. Staypak 및 WPC는 소재(素材)에 비(比)해 횡압축강도(橫壓縮强度)가 70~90% 향상(向上)되었으며, 종압축강도(從壓縮强度)는 10~30% 증가(增加)되었다. 6. Staypak의 비중(比重)은 0.66, 침지법(浸漬法)에 의(依)한 WPC는 0.61, 진공감압법(眞空減壓法)에 의(依)한 WPC의 비중(比重)은 0.62, 소재(素材)는 0.44였다.

  • PDF

좌굴방지장치 영향을 고려한 복합재 적층판의 압축강도에 대한 이차원 크기 효과 (Two Dimensional Size Effect on the Compressive Strength of Composite Plates Considering Influence of an Anti-buckling Device)

  • 공창덕;이정환
    • Composites Research
    • /
    • 제15권4호
    • /
    • pp.23-31
    • /
    • 2002
  • 시편 게이지 면적($길이{\;}{\times}{\;}폭$)의 이차원 크기효과가 T300/924 $[45/-45/0/90]_3s$ 탄소섬유/에폭시 적층판의 압축거동에 대해 조사하였다. 개조된 압축시험치구(ICSTM)와 좌굴방지장치가 $30mm{\;}{\times}{\;}30mm,{\;}50mm{\;}{\times}{\;}50mm,{\;}70mm{\;}{\times}{\;}70mm,{\;}90mm{\;}{\times}{\;}90mm$의 게이지 길이와 폭을 가진 시편들의 압축시험에 사용하였다. 모든 경우의 파괴들은 시편 게이지 길이 내에서 주로 갑자기 발생하였다. 파괴 후 분석결과는 $0^{\circ}$층의 섬유의 미소좌굴에 의해 파괴를 시작하여 최종파괴를 일으키는 임계파괴기구일 것으로 생각되었다. 이것은 매트릭스 지배적인 파괴를 의미하며, 초기섬유굴곡에 따라 파괴가 지배적으로 시작된다는 것을 말한다 이것은 또한 제작공정과 품질이 압축강도를 결정하는 중요한 역할을 한다고 볼 수 있다. 좌굴방지장치를 장착하고 시험할 때 장치의 볼트 조임 토크에 따라 시편과의 접촉마찰 등에 의해 실제 압축강도 보다 크게 나타나는 결과를 보였다. 좌굴방지장치의 영향을 유한요소법을 이용하여 해석한 결과 실제 압축강도 보다 7% 정도 크게 나타남을 확인하였다. 부가적으로 홀을 갖는 시편들의 압축시험도 수행되었다. 홀에 의한 국부응력집중이 적층판 강도에 지배적 요인이었다. 파괴강도는 홀 크기와 시편 폭이 증가할수록 감소하였으나 탄성응력집중계수로 예측된 값보다는 일반적으로 크게 나타났다. 이것은 사용된 복합재가 이상적인 취성재질이 아니라는 것을 의미하며 홀 주위에서 다소간의 응력이완이 발생한다고 볼 수 있다. X선 검사 사진분석에서 섬유좌굴과 층간분리형태의 손상이 파괴하중의 약 80%에서 홀 가장자리로부터 시작되었고 임계파괴크랙길이인 2-3mm의 불안정한 상태에 도달하기 전까지는 하중 증가와 더불어 안정되게 파괴가 진전되었다(시편의 기하학적 크기에 의존함). 이 손상과 파괴는 선형 cohesive zone 모델로 해석되었다. 노치없는 시편의 압축강도와 평면 파괴인성의 측정된 적층판 변수들을 사용하여 홀의 크기와 시편 폭의 함수로서 홀을 갖는 적층판의 압축강도를 성공적으로 예측하였다.

설비공학 분야의 최근 연구 동향 : 2010년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2010)

  • 한화택;이대영;김서영;최종민;김수민;권영철;백용규
    • 설비공학논문집
    • /
    • 제23권6호
    • /
    • pp.449-469
    • /
    • 2011
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering during 2010. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery, and new and renewable energy. Various topics were presented in the field of general thermal and fluid flow. Research issues mainly focused on the thermal reliability of axial fan and compressor in the field of fluid machinery. Studies on the design of ground source heat pump systems and solar chemical reactors were executed in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (3) Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and CO2 were studied. Performance improvement of refrigeration systems are tried applying various ideas of refrigerant subcooling, dual evaporator with hot gas bypass control and feedforward control. The hybrid solar systems combining the solar collection devices with absorption chillers or compression heat pumps are simulated and studied experimentally as well to improve the understanding and the feasibility for actual applications. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. Various studies on heating and cooling systems, HVAC facilities, indoor air environments and energy resources were carried to improve the maintenance and management of building service equipments. In the field of heating and cooling systems, papers on a transformer cooling system, a combined heat and power, a slab thermal storage and a heat pump were reported. In the field of HVAC facilities, papers on a cooling load, an ondol and a drying were presented. Also, studies on HVAC systems using unutilized indoor air environments and energy resources such as air curtains, bioviolence, cleanrooms, ventilation, district heating, landfill gas were studied. (5) In the field of architectural environment and energy, studies of various purposes were conducted such as indoor environment, building energy, renewable energy and green building. In particular, renewable energy and building energy-related researches have mainly been studied reflecting the global interest. In addition, many researches which related the domestic green building certification of school building were performed to improve the indoor environment of school.

가새좌굴을 고려한 역 V형 가새골조의 기둥부재 내진설계법 (Seismic Design of Columns in Inverted V-braced Steel Frames Considering Brace Buckling)

  • 조준희;김정재;이철호
    • 한국강구조학회 논문집
    • /
    • 제22권1호
    • /
    • pp.1-12
    • /
    • 2010
  • 현행 강구조내진설계철학의 근거인 역량설계법(capacity design method)에 의할 때 중심가새골조의 에너지 소산요소인 가새가 인장항복하고 압축좌굴 할 때 보와 기둥은 탄성상태를 유지해야 한다. 중심가새골조의 대표적 형식인 역V형 가새골조의 경우 가새가 좌굴하면 인장가새와 압축가새 사이에 수직불균형력이 발생하여 보와 기둥에 추가적인 하중이 가해지므로 이를 반영하여 보 및 기둥 부재를 탄성설계해야 한다. 지진하중 발생시에 모든 가새가 동시에 좌굴하지 않는다는 것은 잘 알려져 있지만, 특정층의 좌굴발생 유무를 정확히 예견하는 방법은 아직 존재하지 않는다. 따라서 현행 설계기준에서는 모든 층에서의 동시 좌굴을 가정하여 보수적으로 설계하거나 시스템초과강도계수로 증폭된 특별지진하중에 대해 기둥부재를 탄성설계하는 경험적이고 우회적인 방법을 제시하고 있다. 이를 개선하기 위한 첫 번째 단계는 우선 지진 내습시에 좌굴발생이 예견되는 층을 정확히 예측하는 것이다. 본 논문에서는 1차모드 푸쉬오버해석, 고차모드 푸쉬오버해석, 선형고유치해석에 의해 좌굴층을 예측한 후 이를 토대로 가새좌굴이 기둥에 가하는 축력을 산정하는 세 가지의 새로운 방법, 즉 FMPM(First Mode Pushover Method), MMPM (Multi-Mode Pushover Method), MSBM(Mode Shape Based Method)을 제안하였다. 이 세 가지 방안의 핵심은 좌굴 포텐셜이 높은 것으로 감지된 층의 수직불균형력은 선형합산하고 그렇지 않은 층의 수직불균형력은 SRSS(square root of sum of squares)법에 의해 조합하여 기둥에 가해지는 축력을 산정하는 것이다. 3층에서 15층에 이르는 5개의 골조모델에 대해 20개 지진가속도기록을 입력으로 한 방대한 비선형동적해석을 수행하여 제시한 방안의 타탕성을 검증하였다. 세 방법에 의한 기둥설계 결과는 모두 현행 설계기준의 방법보다 기둥의 물량을 대폭 줄이면서도 기둥부재가 탄성상태를 유지하여 역량설계법의 철학을 만족시켰다. 특히 MSBM은 간단한 선형 고유치해석결과만을 이용하지만 본 연구에서 가장 정확한 축력산정법인 MMPM과 큰 차이를 보이지 않을 정도로 정확하다. 실무 여건에서도 사용 가능한 방법으로 MSBM을 추천한다.

내화처리(耐火處理) 및 재건조(再乾操)가 라디에타소나무의 역학적(力學的) 성질(性質)에 미치는 영향(影響) (Effect of fire - retardant treatment and redrying on the mechanical properties of radiata pine)

  • 정두진;조재성;윤기언;김재진;김규혁
    • Journal of the Korean Wood Science and Technology
    • /
    • 제27권1호
    • /
    • pp.37-49
    • /
    • 1999
  • 내화처리 및 재건조가 목재의 역학적 성질에 미치는 영향을 구명하기 위하여 라디에타소나무 변재 무결점 소형 시험편 내로 내화제인 borax-boric acid(BRX), minalith(MIN), pyresote(PYR)를 가압주입한 후 25, 60, 80, $11^{\circ}C$로 재건조한 후 휨성질과 종압축강도를 측정하였다. 내화처리 및 재건조에 의한 라디에타소나무 시편의 역학적 성질 감소 정도는 내화제의 종류, 보유량, 그리고 재건조온도의 조합에 따라 상이하였으며, 내화처리와 재건조온도간에 통계학적으로 매우 높은 유의성을 보이는 상호작용이 존재하였다. 휨강도와 휨파괴시 최대일량은 내화처리에 의해 상당히 감소되었으나 휨탄성계수와 종압축강도는 내화처리에 의해 감소되지 않고 오히려 BRX 처리구의 탄성계수와 BRX 및 PYR 처리구의 종압축강도는 대구조인 무처리구보다 높았다. 몇가지 내화제와 재건조온도의 조합의 휨탄성계수와 종압축강도의 경우를 제외하고는 내화제 보유량간에는 역학적 성질의 차이도 인정되지 않았다. 휨탄성계수와 종압축강도는 재건조온도의 영향을 크게 받지 않는 것으로 나타났다. 그러나 휨강도와 휨파괴시 최대일량은 재건조온도가 증가할수록 일반적으로 감소하였는데, BRX처리구는 재건조온도 $80^{\circ}C$부터, 그리고 MIN과 PYR 처리구는 재건조온도 $110^{\circ}C$에서 대구조와 비교할 때 심각한 휨강도의 감소가 관찰되었다. 따라서 내화처리 라디에타소나무 목재를 구조부재로 사용하기 위해서는 BRX 처리재의 경우는 $60^{\circ}C$, 그리고 MIN과 PYR 처리재의 경우는 $80^{\circ}C$ 이상의 건구온도를 적용하는 것은 삼가야 할 것이다.

  • PDF

설비공학 분야의 최근 연구 동향 : 2007년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2007)

  • 한화택;신동신;최창호;이대영;김서영;권용일
    • 설비공학논문집
    • /
    • 제20권12호
    • /
    • pp.844-861
    • /
    • 2008
  • The papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during the year of 2007 have been reviewed. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro nano fluid, micropump and fuel cell. Traditional CFD was still popular and widely used in research and development. Studies about fans and pumps were performed in the field of fluid machinery. Characteristics of flow and fin shape optimization are studied in the field of piping system. (2) The research works on heat transfer have been reviewed in the field of heat transfer characteristics, heat exchangers, and desiccant cooling systems. The research on heat transfer characteristics includes thermal transport in pulse tubes, high temperature superconductors, ground heat exchangers, fuel cell stacks and ice slurry systems. For the heat 'exchangers, the research on pin-tube heat exchanger, plate heat exchanger, condensers and gas coolers has been cordially implemented. The research works on heat transfer augmenting tubes have been also reported. For the desiccant cooling systems, the studies on the design and operating conditions for desiccant rotors as well as performance index are noticeable. (3) In the field of refrigeration, many papers were presented on the air conditioning system using CO2 as a refrigerant. The issues on the two-stage compression, the oil selection, and the appropriate oil charge were treated. The subjects of alternative refrigerants were also studied steadily. Hydrocarbons, DME and their mixtures were considered and various heat transfer correlations were proposed. (4) Research papers have been reviewed in the field of building facilities by grouping into the researches on heat and cold sources, air conditioning and air cleaning, ventilation and fire research including tunnel ventilation, flow control of piping system, and sound research with drain system. Main focuses have been addressed to the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies were mostly focused on analyzing the indoor environment in various spaces like cars, old tombs, machine rooms, and etc. in an architectural environmental field. Moreover, subjects of various fields such as the evaluation of noise, thermal environment, indoor air quality and development of energy analysis program were researched by various methods of survey, simulation, and field experiment.