• 제목/요약/키워드: Compression Buckling Strength

검색결과 205건 처리시간 0.023초

T300/924C 탄소섬유/에폭시 복합재 적층판의 이차원 압축 강도의 크기효과 및 좌굴방지장치의 영향 (Two Dimensional Size Effect on the Compressive Strength of T300/924C Carbon/Epoxy Composite Plates Considering Influence of an Anti-buckling Device)

  • 공창덕;방조혁;이정환
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 추계학술발표대회 논문집
    • /
    • pp.88-91
    • /
    • 2002
  • The two dimensional size effect of specimen gauge section (length x width) was investigated on the compressive behavior of a T300/924 [45/-45/0/90]3s, carbon fiber-epoxy laminate. A modified ICSTM compression test fixture was used together with an anti-buckling device to test 3mm thick specimens with a 30$\times$30, 50$\times$50, 70$\times$70, and 90mm$\times$90mm gauge length by width section. In all cases failure was sudden and occurred mainly within the gauge length. Post failure examination suggests that $0^{\circ}$ fiber microbuckling is the critical damage mechanism that causes final failure. This is the matrix dominated failure mode and its triggering depends very much on initial fiber waviness. It is suggested that manufacturing process and quality may play a significant role in determining the compressive strength. When the anti-buckling device was used on specimens, it was showed that the compressive strength with the device was slightly greater than that without the device due to surface friction between the specimen and the device by pretoque in bolts of the device. In the analysis result on influence of the anti-buckling device using the finite element method, it was found that the compressive strength with the anti-buckling device by loaded bolts was about 7% higher than actual compressive strength. Additionally, compressive tests on specimen with an open hole were performed. The local stress concentration arising from the hole dominates the strength of the laminate rather than the stresses in the bulk of the material. It is observed that the remote failure stress decreases with increasing hole size and specimen width but is generally well above the value one might predict from the elastic stress concentration factor. This suggests that the material is not ideally brittle and some stress relief occurs around the hole. X-ray radiography reveals that damage in the form of fiber microbuckling and delamination initiates at the edge of the hole at approximately 80% of the failure load and extends stably under increasing load before becoming unstable at a critical length of 2-3mm (depends on specimen geometry). This damage growth and failure are analysed by a linear cohesive zone model. Using the independently measured laminate parameters of unnotched compressive strength and in-plane fracture toughness the model predicts successfully the notched strength as a function of hole size and width.

  • PDF

양단고정 단부구속에 따른 H 형 강재기둥의 좌굴 후 잔존내력 평가 (Evaluation of Post-Buckling Residual Strength of H-Section Steel Column for Both Ends are Fixed Condition)

  • 아베베 다니엘 예쉬와웍;최재혁;김진향
    • 대한기계학회논문집A
    • /
    • 제37권1호
    • /
    • pp.83-88
    • /
    • 2013
  • 연쇄붕괴는 충격이나 폭발 등의 비정상 하중에 의하여 구조물의 하중 전달요소가 제거됨으로써 구조물의 일부 또는 전체가 연쇄적으로 붕괴되는 형상을 말한다. 예상외의 하중이 기둥부재에 작용할 경우, 좌굴이 발생하며 내력저하가 급격히 진행되어 붕괴에까지 이르게 된다. 하지만 좌굴 후 에너지를 흡수할 수 있는 잔존내력이 충분하면 붕괴를 막을 수 있다. 따라서, 구조물이 최종 붕괴상태에 도달되는 전 과정에 대한 기둥부재의 하중-변형관계를 명확히 파악할 필요가 있다. 본 논문에서는 비선형유한요소해석을 실시하여 H 형 강재기둥의 단부 구속조건이 고정일 경우 잔존내력의 변화추이를 파악하였다. 또한, 처짐이론을 기반으로 이론식을 도출하여 해석값과의 적합성을 검토하였다.

Study on the effect of ties in the intermediate length Cold Formed Steel (CFS) columns

  • Anbarasu, M.;Kumar, S. Bharath;Sukumar, S.
    • Structural Engineering and Mechanics
    • /
    • 제46권3호
    • /
    • pp.323-335
    • /
    • 2013
  • This work aims to study the effect of stiffener ties in the behavior of intermediate length open section Cold-Formed Steel (CFS) Columns under axial compression. A comparative study on the behaviour and strength of Cold Formed Steel Columns by changing the direction of projection of lips (i.e., inwards or outwards) are also done. In this work two types of sections were considered Type-I section with lip projecting outwards (hat) and Type-II section with lip projecting inwards (channel). The length of the columns is predicted by performing elastic buckling analysis using CUFSM software. The theoretical analysis is performed using DSM - S100;2007, AS/NZ: 4600-2005 and IS: 801-1975. The compression tests are carried out in a 400 kN loading frame with hinged-hinged end condition. The non-linear numerical analysis is performed using Finite Element software ANSYS 12.0 to simulate the experimental results. Extensive parametric study is carried out by varying the width and spacing of the stiffener ties. The results are compared; the effects of stiffener ties on behaviour and load carrying capacity on both types of columns are discussed.

Flexural Strength of cold-formed steel built-up composite beams with rectangular compression flanges

  • Dar, M. Adil;Subramanian, N.;Dar, Dawood A.;Dar, A.R.;Anbarasu, M.;Lim, James B.P.;Mahjoubi, Soroush
    • Steel and Composite Structures
    • /
    • 제34권2호
    • /
    • pp.171-188
    • /
    • 2020
  • The past research on cold-formed steel (CFS) flexural members have proved that rectangular hollow flanged sections perform better than conventional I-sections due to their higher torsional rigidity over the later ones. However, CFS members are vulnerable to local buckling, substantially due to their thin-walled features. The use of packing, such as firmly connected timber planks, to the flanges of conventional CFS lipped I-sections can drastically improve their flexural performance as well as structural efficiency. Whilst several CFS composites have been developed so far, only limited packing materials have been tried. This paper presents a series of tests carried out on different rectangular hollow compression flanged sections with innovative packing materials. Four-point flexural tests were carried out to assess the flexural capacity, failure modes and deformed shapes of the CFS composite beam specimens. The geometric imperfections were measured and reported. The North American Specifications and Indian Standard for cold-formed steel structures were used to compare the design strengths of the experimental specimen. The test results indicate clearly that CFS rectangular 'compression' flanged composite beams perform significantly better than the conventional rectangular hollow flanged CFS sections.

일축대칭단면 HSB800 강재 플레이트거더의 비탄성 횡비틂좌굴강도의 해석적 평가 (Numerical Analysis of Inelastic Lateral Torsional Buckling Strength of HSB800 Steel Plate Girder with Monosymmetric Section)

  • 박용명;이건준;최병호;황민오
    • 한국강구조학회 논문집
    • /
    • 제25권2호
    • /
    • pp.153-164
    • /
    • 2013
  • 본 연구에서는 균일휨모멘트를 받는 일축대칭단면 HSB800 고강도강 플레이트거더의 횡비틂좌굴(LTB) 강도를 비선형해석으로 평가하였다. 압축플랜지 단면이 인장플랜지에 비해 작은 경우와 큰 경우에 대해 각각 세장, 비조밀 및 조밀 복부판을 갖는 단면들을 고려하였으며, 비지지길이는 비탄성 LTB 영역을 대상으로 하였다. Eurocode 3 및 AASHTO, AISC 기준들과의 비교를 위해 단일패널모델과 3-패널모델을 각각 고려하였으며, 모델의 타당성을 평가하기 위해 SM490 강재 거더에 대해 먼저 해석을 수행하고 각 기준과 비교하였다. 이후 동일한 방법으로 HSB800 강재거더에 대해 LTB 강도 평가 해석을 수행하였으며, 압축플랜지 단면이 인장플랜지에 비해 작고 비조밀플랜지-세장/비조밀복부판 단면들은 현재 기준의 휨강도에 도달하지 못하는 결과를 얻었다.

Behaviour and strength of back-to-back built-up cold-formed steel unequal angle sections with intermediate stiffeners under axial compression

  • Gnana Ananthi, G. Beulah;Roy, Krishanu;Lim, James B.P.
    • Steel and Composite Structures
    • /
    • 제42권1호
    • /
    • pp.1-22
    • /
    • 2022
  • In cold-formed steel (CFS) structures, such as trusses, transmission towers and portal frames, the use of back-to-back built-up CFS unequal angle sections are becoming increasingly popular. In such an arrangement, intermediate welds or screw fasteners are required at discrete points along the length, preventing the angle sections from buckling independently. Limited research is available in the literature on axial strength of back-to-back built-up CFS unequal angle sections. The issue is addressed herein. This paper presents an experimental investigation reported by the authors on back-to-back built-up CFS unequal angle sections with intermediate stiffeners under axial compression. The load-axial shortening behaviour along with the deformed shapes at failure are reported. A nonlinear finite element (FE) model was then developed, which includes material non-linearity, geometric imperfections and modelling of intermediate fasteners. The FE model was validated against the experimental test results, which showed good agreement, both in terms of failure loads and deformed shapes at failure. The validated finite element model was then used for the purpose of a parametric study comprising 96 models to investigate the effect of longer to shorter leg ratios, stiffener provided in the longer leg, thicknesses and lengths on axial strength of back-to-back built-up CFS unequal angle sections. Four different thicknesses and seven different lengths (stub to slender columns) with three overall widths to the overall depth (B/D) ratios were investigated in the parametric study. Axial strengths obtained from the experimental tests and FE analyses were used to assess the performance of the current design guidelines as per the Direct Strength Method (DSM); obtained comparisons show that the current DSM is conservative by only 7% and 5% on average, while predicting the axial strengths of back-to-back built-up CFS unequal angle sections with and without the stiffener, respectively.

원형PET용기와 사각PET용기의 압축하중시 변형거동에 관한 수치적 연구 (Numerical Study of the Deformation Characteristics for Circle Shaped and Square Shaped PET Bottles under Compressive Loads)

  • 조승현;권창오;박균명;고영배
    • 소성∙가공
    • /
    • 제23권1호
    • /
    • pp.5-9
    • /
    • 2014
  • Although much research has been conducted to reduce the thickness of PET bottles in order to save manufacturing costs, the challenge remains of guaranteeing mechanical strength for top-loaded thin PET bottles. The current study investigates the large deformation characteristics of a circle shaped PET bottle and a square shaped PET bottle when compressively loaded using FEA. The arc length method is used in the nonlinear FEA to understand the buckling phenomenon. For PET bottles with the same capacity, the circle shaped bottle shows more resistance to buckling and compression loading than the square shaped bottle.

Seismic behavior of Q690 circular HCFTST columns under constant axial loading and reversed cyclic lateral loading

  • Wang, Jiantao;Sun, Qing
    • Steel and Composite Structures
    • /
    • 제32권2호
    • /
    • pp.199-212
    • /
    • 2019
  • This paper presents an investigation on seismic behavior of out-of-code Q690 circular high-strength concrete-filled thin-walled steel tubular (HCFTST) columns made up of high-strength (HS) steel tubes (yield strength $f_y{\geq}690MPa$). Eight Q690 circular HCFTST columns with various diameter-to-thickness (D/t) ratios, concrete cylinder compressive strengths ($f_c$) and axial compression ratios (n) were tested under the constant axial loading and reversed cyclic lateral loading. The obtained lateral load-displacement hysteretic curves, energy dissipation, skeleton curves and ductility, and stiffness degradation were analyzed in detail to reflect the influences of tested parameters. Subsequently, a simplified shear strength model was derived and validated by the test results. Finally, a finite element analysis (FEA) model incorporating a stress triaxiality dependent fracture criterion was established to simulate the seismic behavior. The systematic investigation indicates the following: compared to the D/t ratio and axial compression ratio, improving the concrete compressive strength (e.g., the HS thin-walled steel tube filled with HS concrete) had a slight influence on the ductility but an obvious enhancement of energy dissipation and peak load; the simplified shear strength model based on truss mechanism accurately predicted the shear-resisting capacity; and the established FEA model incorporating steel fracture criterion simulated well the seismic behavior (e.g., hysteretic curve, local buckling and fracture), which can be applied to the seismic analysis and design of Q690 circular HCFTST columns.

Performance of innovative composite buckling-restrained fuse for concentrically braced frames under cyclic loading

  • Mohammadi, Masoud;Kafi, Mohammad A.;Kheyroddin, Ali;Ronagh, Hamid R.
    • Steel and Composite Structures
    • /
    • 제36권2호
    • /
    • pp.163-177
    • /
    • 2020
  • Concentrically Braced Frames (CBFs) are commonly used in the construction of steel structures because of their ease of implementation, rigidity, low lateral displacement, and cost-effectiveness. However, the principal disadvantage of this kind of braced frame is the inability to provide deformation capacity (ductility) and buckling of bracing elements before yielding. This paper aims to present a novel Composite Buckling Restrained Fuse (CBRF) to be utilized as a bracing segment in concentrically braced frames that allows higher ductility and removes premature buckling. The proposed CBRF with relatively small dimensions is an enhancement on the Reduced Length Buckling Restrained Braces (RL-BRBs), consists of steel core and additional tensile elements embedded in a concrete encasement. Employing tensile elements in this composite fuse with a new configuration enhances the energy dissipation efficiency and removes the tensile strength limitations that exist in bracing elements that contain RL-BRBs. Here, the optimal length of the CBRF is computed by considering the anticipated strain demand and the low-cyclic fatigue life of the core under standard loading protocol. An experimental program is conducted to explore the seismic behavior of the suggested CBRF compare with an RL-BRB specimen under gradually increased cyclic loading. Moreover, Hysteretic responses of the specimens are evaluated to calculate the design parameters such as energy dissipation potential, strength adjustment factors, and equivalent viscous damping. The findings show that the suggested fuse possess a ductile behavior with high energy absorption and sufficient resistance and a reasonably stable hysteresis response under compression and tension.

폭두께비에 따른 강판콘크리트구조의 압축거동 (Compression Behavior of Steel Plate-Concrete Structures with the Width-to-Thickness Ratio)

  • 한홍수;최병정;한권규
    • 한국강구조학회 논문집
    • /
    • 제23권2호
    • /
    • pp.229-236
    • /
    • 2011
  • 본 연구는 폭두께비(W/T)에 따른 중심압축하중을 받는 SC(Steel Plate-Concrete)구조의 압축거동 특성을 파악하는 것이 주목적이다. SC구조는 전단 연결재를 갖는 샌드위치 강판 사이에 콘크리트를 타설하여 시공하는 구조이다. SC구조의 실험체는 폭두께비(W/T)가 1.60와 3.56인 실험체로 구분하였다. 실험을 통하여 다음과 같은 결과를 얻었다. SC구조 실험체의 파괴양상은 최대압축강도에 도달하기 전에 스터드와 스터드 사이 강판이 국부좌굴하고 콘크리트는 일부 균열 및 박리현상이 나타났다. 또한 SC구조 실험체의 최대압축강도는 기존 설계기준식(AISC 2005, ACI318-05 및 KBC 2005)에 의한 압축강도보다 거의 크게 나타났다. SC구조 실험체의 폭두께비(W/T)가 증가할수록 강판에 의한 SC구조 실험체의 콘크리트 구속효과는 감소하는 것으로 나타났다.