• Title/Summary/Keyword: Compressible Flow Analysis

Search Result 298, Processing Time 0.028 seconds

A Computational Analysis of the Under-Expanded Moist Air Jet (부족팽창 습공기제트에 관한 수치해석적 연구)

  • Baek Seung-Cheol;Song Chul-Hwa;Toshiaki Setoguchi;Kim Heuy-Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.2 s.233
    • /
    • pp.197-204
    • /
    • 2005
  • The under-expanded jet discharged from a nozzle or an orifice has been extensively employed in industrial applications and aerospace technologies. A number of studies have been made to investigate the under-expanded jet structures such as Mach disk, barrel shock wave, jet boundary configuration, etc. In the current study, a computational work is performed to investigate the effect of non-equilibrium condensation of moist air on the under-expanded jet, which is discharged from a sonic nozzle. The results obtained are compared with an available experimental data. It is found that non-equilibrium condensation of moist air alleviates the oscillations of the under-expanded jet, and can increase Mach disk diameter, without changing the location.

Analysis and Design Spike-Nosed Configurations in Supersonic Flow (초음속 유동장 Blunt-spike 선두 형상 설계 및 해석)

  • Gang, Hong-Jae;O, Seong-Won;Choe, Han-Ul;Hwang, Je-Yeong;Son, Chan-Gyu;Lee, Gwan-Jung
    • Proceeding of EDISON Challenge
    • /
    • 2012.04a
    • /
    • pp.37-40
    • /
    • 2012
  • EDISON CFD 수치 해법 기법을 바탕으로 초음속 유동장 속에서 spike가 부착된 무딘 물체에 대하여, spike 형상 변화에 따른 압축성 효과에 의한 항력 변화 추이를 고찰하였다. Spike의 길이 따른 항력 변화 추이를 살펴보았다. Spike의 길이가 Main body와 특정한 비율을 가질 때 항력이 최소가 된다. 이를 기준으로 spike 길이가 특정 길이만큼 줄어들거나 늘어날 경우에 각각 1.35%, 4.95% 항력이 증가하였다. 이러한 자료들은 초음속 유동장에서 무딘 물체에 가해지는 압축성 효과에 의한 저항을 최소화하기 위한 spike 설계 시 중요한 견해를 제공한다.

  • PDF

Computational and Experimental Analysis of Exhaust Pipe Pressure Distributions in a Single Cylinder Gasoline Engine (단기통 가솔린 엔진 배기단의 압력 변화에 관한 실험 및 수치해석)

  • Jeong, H.M.;Choi, S.C.;Sim, K.J.;Kim, S.H.;Koh, D.K.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.8 no.4
    • /
    • pp.5-10
    • /
    • 2004
  • 본 연구는 단기통 4행정 기관의 배기단의 형상에 따른 실험과 수치해석이 소개되었다. 흡 배기 밸브가 작동하고 있고, 주요한 배기단의 변수로는 배기단 직경이 적용이 되었다. 실험결과로는 배기단의 직경에 따라 배기 압력은 많은 영향을 받았는 것으로 나타났다. 배기단의 직경이 감소하였을때, 배기압력파의 진폭과 파수가 증가되었다. 배기단의 직경이 증가 하였을 때, 배기압력파의 진폭이 감소하였다. 직경이 22mm 일 때의 소음의 주파수 분석이 16mm와 28mm 보다 진폭이 작게 나타났다.

  • PDF

Frequency Response Characteristics of Hydraulic Pipeline Systems (유압관로계의 주파수 응답특성)

  • 김도태;홍성태
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.38-44
    • /
    • 2000
  • An oil hydraulic line is modeled in which a pipe or two pipes of different size connected in series and terminated in a chamber, i.e. a composite line system. The frequency response characteristics are investigated analytically and experimentally. The theoretical analysis is base on unsteady laminar flow of a viscous compressible fluid. It is generally difficult to obtain exactly the frequency equation of these lines system and its solutions in consideration of viscosity of hydraulic fluid, because the diameters of two pipes and length are different. The effect of the position where the cross-sectional area of changes suddenly, the inner radius of pipe and the volume of terminal chamber on the frequency characteristics of this composite line system are also described.

  • PDF

Cooling Characteristics of a Parallel Channel with Protruding Heat Sources Using Convection and Conduction Heat Transfer (돌출된 열원이 있는 채널에서 대류와 전도열전달을 이용한 냉각특성)

  • 손영석;신지영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.923-930
    • /
    • 2002
  • Cooling characteristics of a parallel channel with protruding heat sources using convection and conduction heat transfer are studied numerically. A two-dimensional model has been developed for numerical prediction of transient, compressible, viscous, laminar flow, and conjugate heat transfer between parallel plates with uniform block heat sources. The finite volume method is used to solve the problem. The assembly consists of two channels formed by two covers and one printed circuit board which has three uniform heat source blocks. Six different cooling methods are considered to find out the most efficient cooling method in a given geometry and heat sources. The velocity and temperature fields of cooling medium, the temperature distribution along the block surface, and the maximum temperature in each block are obtained. The results are compared to examine the cooling characteristics of the different cooling methods.

A Flowfield Analysis Around an Airfoil by Using the Euler Equations (Euler 방정식을 사용한 익형 주위에서의 유동장 해석)

  • Kim M. S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1999.05a
    • /
    • pp.186-191
    • /
    • 1999
  • An Euler solver is developed to predict accurate aerodynamic data such as lift coefficient, drag coefficient, and moment coefficient. The conservation law form of the compressible Euler equations are used in the generalized curvilinear coordinates system. The Euler solver uses a finite volume method and the second order Roe's flux difference splitting scheme with min-mod flux limiter to calculate the fluxes accurately. An implicit scheme which includes the boundary conditions is implemented to accelerate the convergence rate. The multi-block grid is integrated into the flow solver for complex geometry. The flowfields are analyzed around NACA 0012 airfoil in the cases of $M_{\infty}=0.75,\;\alpha=2.0\;and\;M_{\infty}=0.80,\;\alpha=1.25$. The numerical results are compared with other numerical results from the literature. The final goal of this research is to prepare a robust and an efficient Navier-Stokes solver eventually.

  • PDF

Numerical Study of Tunnel Hood to Reduce Micro-Pressure Wave on Conventional Railways (기존선 터널 출구 미기압파 저감을 위한 터널 후드의 수치 해석적 연구)

  • Kim Byeong-Yeol;Kwon Hyeok-Bin;Yun Su-Hwan;Ku Yo-Cheon;Ko Tae-Hwan;Lee Dong-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.6 s.31
    • /
    • pp.513-519
    • /
    • 2005
  • The Korean Tilting Train eXpress may produced a strong micro-pressure wave in tunnel exit because of large train/tunnel area ration of conventional railways. This micro-pressure wave causes an impulsive noise which is a serious environmental noise pollution near tunnel exit. Tunnel hood can be the method of reducing the micro-pressure wave in tunnel exit. Therefore, parametric studies for tunnel hood are performed with respect to the hood length and size to investigate the effects of the tunnel hood. Also, axi-symmetric unsteady compressible flow solver was used to analyze train-tunnel relative motion. According to the result of numerical analysis, the maximum micro-pressure wave in tunnel exit is reduced by 56% throughout the hood establishment on conventional railways.

Steady State Analysis of Magnetic Head Slider at Ultra Low Clearance (마그네틱 헤드 슬라이더의 極小 空氣膜에 대한 定常狀態 解析)

  • 장인배;한동철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.4
    • /
    • pp.764-770
    • /
    • 1989
  • This paper analyze the steady state performance of a self-acting air lubricated slider bearing in hard disk/head system. Modified Reynolds' equation is derived from the steady state compressible Navier-Stokes equation, under slip-flow conditions. Finite difference technique and numerical procedure are described by using Newton-Raphson iteration method to slove the non-linear equations. These techniques are applied to conventional slider bearings and the effects of molecular mean free path(MMFP) for a recording surface of hard disk are shown. The calculation procedure developed here, wide applicabilities in practical head design procedures, and converges rapidly.

Numerical Analysis of Forced and Mixed Convection around the Circular Cylinder for Compressible Flow (압축성 유동장에서의 원형 실린더 주위의 강제 및 혼합대류에 대한 수치 해석)

  • 최윤호;이현찬;유재석;김기현
    • Journal of Energy Engineering
    • /
    • v.4 no.1
    • /
    • pp.126-139
    • /
    • 1995
  • 저속의 압축성 유동장에서의 원형 실린더 주위의 유동 및 열전달특성을 해석하였다. 비압축성 유동장에서의 실린더 주위의 유동 및 열전달현상에 대하여는 실험과 수치해석을 포함한 광범위한 연구가 진행되어 왔으며 매우 잘 알려져 있다. 실린더 벽면과 주위 유동장의 온도차가 큰 경우, 밀도의 변화가 커지므로 유동장은 압축성 유체가 되나 지배 방정식의 복잡함과 적절한 수치해석 방법의 부족으로 실린더 주위의 유동장을 압축성유체로 해석한 경우는 매우 드물다. 현재 압축성유동 해석에 널리 사용되는 time marching algorithm은 저속의 유동장 해석시 지배방정식에 나타나는 eigenvalue들의 괴리에 의하여 수렴속도가 현저히 떨어지게 된다. 본 연구에서는 이와 같은 난점을 극복할 수 있는 time-derivative preconditioning 방법을 사용하여 온도차가 큰 유동장에서의 강제 및 혼합대류에 대한 계산을 수행하였고 이들의 열전달특성을 비교하였다. 강제대류의 경우 실린더 벽면 온도의 증가에 따른 밀도 감소의 영향은 유동장의 Re수를 감소시켜 확산의 영향을 증가시키면서, 혼합대류의 경우 부력의 영향은 가열되는 유동장의 범위와 재순환 영역을 강제대류에 비해 현저히 감소시킨다.

  • PDF

Analysis of Decompression Control Characteristics of Pneumatic Pressure Control System Considering Heat Transfer Characteristics (열전달 특성을 고려한 공기압 압력제어계의 감압제어특성 해석)

  • Jang, J.S.
    • Journal of Power System Engineering
    • /
    • v.10 no.1
    • /
    • pp.90-95
    • /
    • 2006
  • Pneumatic control systems have been mainly used as a high speed operating system. Therefore, state change of air in a control volume was assumed to be adiabatic change and, pneumatic control systems have been analyzed by using this assumption. Especially, when absolute value of pressure change in the control volume is small, there is a tendency to neglect effect of temperature change on pneumatic control system because temperature change owing to pressure change is small. In this study, an effect of temperature change of air on the decompression control process was analyzed by considering change of mass flow rate, and heat transfer characteristics between air in the chamber and the chamber wall. As a result, this study could confirm that a slight temperature change of the air in the pneumatic pressure control system can influence on the dynamic characteristics of pressure response, and pressure control performance.

  • PDF