• 제목/요약/키워드: Component load Characteristic

검색결과 61건 처리시간 0.027초

Q축 제로 인덕턴스를 위한 영구자석 매입형 동기 릴럭턴스 전동기 특성 연구 (A Study on the Characteristics of PMASynRM for Zero Inductance of Q-axis)

  • 서준;김영현;김홍석;이중호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.894-895
    • /
    • 2015
  • This paper deals with the characteristic analysis & optimum design of Permanent Magnet Assisted Synchronous Reluctance Motor(PMASynRM) for Premium Efficiency Performance. The focus of this paper is characteristic analysis of d and q-axis inductances and torque according to magnetizing quantity of interior permanent magnet for PMASynRM. The d and q-axis current component ratios, load angles of a PMASynRM are investigated quantitatively on the basis of the proposed analysis method and the experimental test. Comparisons are given with output characteristic curves of PMASynRM and those according to the rated wattage in PMASynRM, respectively. And optimum design of PMASynRM is performed by Response Surface Methodology(RSM).

  • PDF

조합하중을 받는 원통형 곡판구조의 좌굴 및 최종강도 거동에 관한 연구 (A Study on the Buckling and Ultimate Strength for Cylindrically curved plate subject to combined load)

  • 오영철;고재용;이경우
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2007년도 추계학술대회 및 제23회 정기총회
    • /
    • pp.25-26
    • /
    • 2007
  • Ship are typically thin-walled structures and consists of stiffened plate structure by purpose of required design load and weight reduction etc. Also, a hull structural characteristics are often used in structures with curvature at deck plating with camber, side shell plating at fore and aft parts and bilge circle parts, It have been believed that these structures can be modelled fundamentally by a part of cylinder. Structural component with curvature subjected to combined loading regimes and complex boundary conditions, which can potentially collapse due to buckling. Hence, for more rational and safe design of ship structures, it is crucial importance to better understand the interaction relationship of the buckling and ultimate strength for cylindrically curved plate under these load components. In this study, the ultimate strength characteristic of curved plate under combined load(lateral pressure load + axial compressive load) are investigated through using FEM series analysis with varying geometric panel properties.

  • PDF

고압전동기용 진동 감시 시스템을 위한 특징 파라미터 추출기법 개발 (Development of the Extracting Technique of the Character Parameter for the Vibration Monitoring System in High Voltage Motor)

  • 이달호;박정철
    • 한국정보전자통신기술학회논문지
    • /
    • 제12권4호
    • /
    • pp.349-358
    • /
    • 2019
  • 본 논문에서는 회전체의 특징 파라미터들을 추출하기 위한 센서의 신호들을 수집하는 방법을 연구하고자 한다. 이를 위해, 모형 시험을 수행하기 위한 진동 테스트 리그를 개발하여 정상적으로 운전하에서의 신호특성을 분석하였다. 다른 진동 요소들로부터 주기적인 충격에 의해 발생되는 진동 성분을 추출하기 위하여 포락 신호처리(Envelope FFT Analysis) 기법을 사용하였다. 회전속도에 따른 신호분석과 더불어 회전체의 저주파수 특성을 잘 나타내는 속도센서 및 진동 테스트 리그의 부하변화에 따른 신호를 분석하였다. 그 결과, 베어링 하우징에서 측정되는 가속도 신호는 진폭이 작으며 조화 성분과 모터의 회전주파수 성분만이 발생함을 확인하였다. 즉, 회전수가 높아짐에 따라 가속도의 진폭이 높아짐을 확인할 수 있었다. 회전속도가 증가하면 원 데이터의 형상의 차이가 있는 것을 확인할 수 있었고, 가속도 FFT 그래프와 비교하였을 경우 저 주파수에서 노이즈에 강하며 해당 회전 주파수 성분을 뚜렷하게 나타내었다. 또한 부하를 변화시켜도 주요 회전 주파수 성분이 증가하지 않음을 알 수 있었다.

POWER FACTOR CORRECTION OF CO2 WELDING MACHINE USING SINGLE-SWITCH THREE-PHASE AC/DC CONVERTER

  • Kim, Jse-Mun;Kim, Yuen-Chung;Ahn, Jung-Jun;Won, Chung-Yuen;Kim, Sei-Chan
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.663-667
    • /
    • 1998
  • This paper describes for reducing harmonic distortion on CO2 welding machine with nonlinear load characteristic using single-switch three-phase AC/DC converter. The low-order harmonic component amplitude of the phase current of single-switch three-phase discontinuous mode is calculated. Experimental results show that CO2 welding machine with single-switch three-phase AC/DC converter is effectively controlled with power factor correction for phase current during welding time.

  • PDF

Study on Phase-Segregated Active Power Filter using PLECS

  • Zhang, Ying-Hao;Oh, Hyoung-Lok;Lim, Han-Jun;Zhang, Wen-Hao;Kim, Du-Sik
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.216-217
    • /
    • 2013
  • This paper presents an algorithm for a phase-segregated active power filter for three-phase electric system. Due to the symmetrical characteristic of three-phase system and the specialty of distribution system, the proposed algorithm focuses on the extraction of harmonic component of load current in each phase and simulations have been done by PLECS software to verify the validity of the proposed algorithm while loads are nonlinear.

  • PDF

기계적 분석을 통한 송전용 자기 애자의 열화 판단 및 파손 부위에 대한 연구 (Determination of Deterioration and Damage of Porcelain Insulators in Power Transmission Line Through Mechanical Analysis)

  • 손주암;최인혁;구자빈;김태용;전성호;이윤정;이준신
    • 한국전기전자재료학회논문지
    • /
    • 제33권1호
    • /
    • pp.50-55
    • /
    • 2020
  • Porcelain insulators have been used for a long time in 154 kV power transmission lines. They are likely to be exposed to sudden failure because of product deterioration. This study was conducted to evaluate the quality of porcelain insulators. After stresses were applied, the damaged regions of aged insulators were investigated in terms of chemical composition, material structure, and other properties. For porcelain insulators that were in service for a long time, the mechanical failure load was 126 kN, whereas the average mechanical failure load was 167.3 kN for new products. It was also determined that corrosion occurred at the metal pin part due to the penetration of moisture into the gap between the pin and the ceramic. Statistical analyses of failure were performed to identify the portion of the insulators that were broken. Cristobalite porcelain insulators fabricated without alumina additives had a high failure rate of 54% for the porcelain component. In the case of the addition of Alumina (Al2O3) to the porcelain insulators to improve the strength of the ceramic component, a more frequent damage rate of the cap and pin of 73.3% and 27%, respectively, was observed. This study reports on the material component of SiO2 and the percentage of alumina added, with respect to the mechanical properties of porcelain insulators.

고주파 직렬공진형 DC-DC Converter의 특성 해석 (The Analysis of a High Frequency Series Resonant DC-DC Converter)

  • 이윤종;김철진
    • 대한전기학회논문지
    • /
    • 제39권9호
    • /
    • pp.934-943
    • /
    • 1990
  • There are no turn-on losses in the series Resonant Converter which operates above the resonance frequency, and the commutation stress on the switched component is low. For a given Series Resonant Converter with specified load resistance, the output voltage is a function of the operation frequency. This paper describes the static and dynamic characteristic analysis of the Series Resonant DC to DC Converter, which is operating above the resonant frequency, with frequency control. For the analysis method, state plane technique is adopted, and the circuit operation is defined from normalized switching frequency, Fsn. Under this condition, circuit performance is analyzed ideally. The validity of the proposed analysis is verified by comparing with experimental results, the stability of the converter is confirmed against small variations around the operating point by conventional frequency domain analysis, and the stress quantity added to switch component is shown.

  • PDF

배전시스템 고조파 모델링에 관한 연구 (Harmonics Modelling for Distribution System)

  • 한형주;왕용필;정형환;성병화;박희철;박인표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.205-207
    • /
    • 2005
  • In this paper, the Point of Common Coupling (PCC) is selected to analyze harmonic characteristic of distribution system by IEC 61000 - 3 - 6 in Electromagnetic Compatibility(EMC). Harmonic voltage and current were measured at the PCC of real distribution system. Harmonic distribution, nonlinear load component and Total Harmonic Distortion(THD) were verified by measurement. The effective and accurate modelling of real distribution system were proved through a analysis of harmonic impedance, voltage and current in steady-state. Harmonic transfer characteristic in distribution system were summarized and investigated through a analysis of harmonic voltage and harmonic current in harmonic current source.

  • PDF

Behavior and modeling of single bolt lap-plate connections

  • Rex, Clinton O.;Easterling, W. Samuel
    • Steel and Composite Structures
    • /
    • 제2권4호
    • /
    • pp.277-296
    • /
    • 2002
  • A research investigation of single bolt lap-plate connection load-deformation behavior is presented. Each important characteristic of this behavior is evaluated and two methods for analytically approximating the behavior are developed and presented. The first of these methods is a component method in which the behavior of the connection is modeled as a combination of the behavior of the parts. The second method utilizes a number of parametric relationships that relate the connection parameters to coefficients of two non-linear continuous analytical curves. The test results from four independent experimental programs that investigated the behavior of single bolt lap-plate connections are used in the development and verification of these methods.

마이크로 가스터빈 발전시스템의 운전성능 분석 (Analysis of Operation Performance of a Micro Gas Turbine Generator System)

  • 이종준;김동섭
    • 한국유체기계학회 논문집
    • /
    • 제8권5호
    • /
    • pp.13-21
    • /
    • 2005
  • This study aims to analyze operating performance of a micro gas turbine with the aid of detailed measurements of various system parameters. In addition to embedded measurements, parameters such as exhaust temperatures, engine inlet temperatures and fuel flow rates are measured. Variations in measured data and estimated performance parameters are analyzed. Those data are processed to calculate losses along the power transmission line and the net gas turbine performance (power and efficiency based on the gas turbine shaft end) is isolated from the overall system performance. A method to estimate characteristic parameters such as component efficiencies, based on the comparison between measured and predicted performance data, is suggested and exemplified for the full load condition.