• Title/Summary/Keyword: Compliance Coefficient

Search Result 95, Processing Time 0.025 seconds

Compliance Control of DD Manipulator using Ultrasonic Motor (초음파 모터를 사용한 DD 매니퓰레이터의 컴플라이언스 제어)

  • Kim, Dong-Ok;Sin, Duck;Kim, Won-Bae;Sung, Do-Saing;Kim, Young-Dong
    • Proceedings of the KIPE Conference
    • /
    • 1996.06a
    • /
    • pp.47-51
    • /
    • 1996
  • In this paper, we propose a method for compliance control of a SCARA type 2-freedom direct drive(DD) manipulator. Each joint of the manipulator is driven by a travelling ultrasonic motor(USM). The travelling USM has good some characteristics over conventional servo motors such as compact size, light weight, silent motion, high torque and high speed response. By controlling the elasticity and viscosity of robot joints, a robot can work in compliance with external environment. we control the elastic coefficient and the viscous coefficient of joint by adjusting the phase difference of the motor power. And we contemplate transient response of USM with adjusting the elastic coefficient and the viscous coefficient. To use the result, we can control the robot to reach its goal with compliance motion. It remains for further research to develop the impedance control of USM.

  • PDF

Measurement of Dynamic MOE of 3-Ply Laminated Woods by Flexural Vibration and Comparison with Blending Strength and Creep Performances

  • Park, Han-Min;Byeon, Hee-Seop
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.46-57
    • /
    • 2006
  • To estimate nondestructively strength performances of laminated woods, 3-ply parallel- and cross-laminated wood specimens exposed under atmosphere conditions after bending creep test were prepared for this study. The effects of density of species, arrangement of laminae and lamination types on dynamic MOE obtained by flexural vibration were investigated, and regression analyses were conducted in order to estimate static bending strength and bending creep performances. Dynamic MOE of parallel-laminated woods showed 1.0~1.2 times higher values than static bending MOE, and those of cross-laminated woods showed 1.0~1.4 times higher values than static bending MOE. The degree of anisotropy of dynamic MOE perpendicular to the grain of face laminae versus that parallel to the grain of face laminae was markedly decreased by cross-laminating. There were strong correlations between dynamic MOE by flexural vibration and static bending MOE (correlation coefficient r = 0.919~0.972) or bending MOR (correlation coefficient r = 0.811~0.947) of 3-ply laminated woods, and the correlation coefficient were higher in parallel-laminated woods than in cross-laminated woods. It indicated that static bending strength performances were able to be estimated from dynamic MOE by flexural vibration. Also, close correlations between the reciprocal of dynamic MOE by flexural vibration and initial compliance at 0.008 h of 3-ply laminated woods were found (correlation coefficient r = 0.873~0.991). However, the correlation coefficient between the reciprocal of dynamic MOE and creep compliance at 168 h of 3-ply laminated woods was considerably lower than those between dynamic MOE and initial compliance, and it was hard to estimate creep compliance with a high accuracy from dynamic MOE due to the variation of creep deformation.

Measurement of Crack Length by Ultrasonic Attenuation Coefficient (초음파 감쇠계수에 의한 균열길이의 측정)

  • Chung, Nam-Yong;Park, Sung-Il
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.340-345
    • /
    • 2003
  • In this paper, the ultrasonic attenuation coefficient was measured by variation of crack length for double-cantilever beam(DCB) specimen. The energy release rate, G, was obtained by the experimental measurement of compliance. The experimental results represents that the relation between crack length for the ultrasonic attenuation coefficient and energy release rate is increased proportionally. From the results of experiments, the measurement method of crack length by the ultrasonic attenuation coefficient was proposed and discussed.

  • PDF

Measurement of Crack Length by Ultrasonic Attenuation Coefficient (초음파 감쇠계수에 의한 균열길이의 측정)

  • Chung, Nam-Yong;Park, Sung-Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.4
    • /
    • pp.386-393
    • /
    • 2004
  • In this paper, the ultrasonic attenuation coefficient was measured by variation of crack length for double-cantilever beam(DCB) specimen. The energy release rate, G, was obtained by the experimental measurement of compliance. The experimental results represents that the crack length for the ultrasonic attenuation coefficient and energy release rate is increases proportionally From the experimental results, we proposed a detecting method of the crack length by the ultrasonic attenuation coefficient and discussed it.

Measurement of Crack Length by Ultrasonic Attenuation Coefficients on Interfaces of Al/Epoxy Bonded Dissimilar Materials (Al/Epoxy 이종재 접합 계면의 초음파 감쇠계수에 의한 균열길이의 측정)

  • Park, Sung-Il;Chung, Nam-Yong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1109-1114
    • /
    • 2003
  • The initial crack often occurs on the bonded interface and it is the general cause of the interface fracture. It is very significant to establish the measurement method of interfacial crack by applying the ultrasonic technology into the interface of bonded dissimilar materials. In this paper, the interfacial crack length was measured by ultrasonic attenuation coefficient in the Al/Epoxy bonded dissimilar materials of double-cantilever beam(DCB). The energy release rate, G, was obtained by the experimental and Ripling's equation measurement of compliance. The experimental results represent that the relation between interfacial crack length for the ultrasonic attenuation coefficient and energy release rate is increased proportionally. From the experimental results, a measurement method of the interfacial crack length by the ultrasonic attenuation coefficient was proposed and discussed.

  • PDF

A Study on the Compliance of Kidney Transplantation Recipients (신장이식환자의 치료지시 이행정도)

  • Hwang, Young-Hui;Choe, Myoung-Ae
    • Journal of Korean Critical Care Nursing
    • /
    • v.4 no.2
    • /
    • pp.15-25
    • /
    • 2011
  • Purpose: The purpose of this study was to identify compliance of kidney transplantation(=KT) recipients and the factors influencing on compliance of KT recipients. Methods: One hundred patients who visited out-patients department after KT at S hospital transplant center in Seoul were enrolled in this study. Structured questionnaires of compliance, self-efficacy and family support were used to collect data. The data was collected from April 21 to May 21 in 2011. The data were analyzed by descriptive statistics, independent t-test, ANOVA and Pearson correlation coefficient. Statistical significance was accepted to the level of p<.05. Results: The mean score of compliance was 4.37(range from 1 to 5), and that of medication compliance was the highest and that of self care compliance was the lowest. There were no differences of compliance according to characteristics of the subjects. Compliance of the subjects had positive correlation with self-efficacy(r=0.23, p<0.05) and family support(r=0.33, p<0.05). Conclusion: Based on these results, it can be concluded that the nursing intervention program to improve self care using self-efficacy and family support need to be developed.

  • PDF

An Experimental Study for the Development of Epoxy Adhesives for Optical Top (광학정반용 에폭시 접착제 개발을 위한 실험적 연구)

  • Gil, Hyeong-Gyeun;Youn, Seok-Weon;Kim, Kwang-San
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.8
    • /
    • pp.727-733
    • /
    • 2010
  • Optical tables provide a platform for the establishment and test of measurement systems which use Laser. Therefore, not only static characteristics such as surface flatness, static stiffness and etc. but dynamic response characteristics is very important design parameter. The dynamic stiffness is generally estimated through the modal test, and compliance is used as a representative performance standard. Recently there is an example of defining the dynamic deflection coefficient and using it as a new performance standard of the dynamic stiffness, but it is not generalized yet in industry. In this study, we verify the validity of existing DDC calculus by making an experiment on granite. And for improvement in damping performance of optical tables, we are going to evaluate the effect of fillers on the compliance, then develop an epoxy adhesive based on the result of this experiment.

A Study on the Shaft End Displacement of the Centrifugal Pump under Nozzle Loads using Compliance Coefficients (컴플라이언스 계수에 의한 노즐하중 하에서의 원심펌프의 축단변위에 관한 연구)

  • 최복록;박진무;김광은
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.4
    • /
    • pp.233-239
    • /
    • 2000
  • Investigation results are presented fur the shaft end displacements due to the elastic deformation of the casing and support in double suction centrifugal pump. Suction and discharge nozzles of the pump are subject to external piping loads and, in API 610, maximum values of their components are specified. This means that each nozzle can be subject to various combinations of loading conditions. Considering upper and lower criteria of each load, we must perform for the 4,096 load cases, and assign the direction and range of the loads. So, this paper develops an efficient procedure(Compliance Coefficient Method) to calculate the shaft end displacements(@ coupling) to determine whether satisfying the pump's standard. Also, we analyzed the effects of the casing and support thickness on shaft end displacements.

  • PDF

A study on relationship between HbA1c, WHR, WTR and compliance in elderly diabetes mellitus patients (노인 당뇨병 환자의 당화혈색소, 허리/엉덩이둘레, 허리/허벅지둘레 및 치료지시이행과의 관계)

  • Yoo, Yong Kwon;Song, Min Sun
    • Journal of Home Health Care Nursing
    • /
    • v.22 no.1
    • /
    • pp.14-21
    • /
    • 2015
  • Purpose: The purpose of this study was to identify relationships between HbA1c (Glycosylated Hemoglobin), WHR (Waist hip ratio), WTR (Waist thigh ratio) and compliance in elderly diabetes mellitus patients aged 65 years or over. Method: We conducted a survey and measured HbA1c, WHR, WTR in a total of 180 elderly patients with diabetes from 5 May 2014 to 30 May 2014. The data were analyzed by t-test, ANOVA, and Pearson's Correlation Coefficient using the SPSS program. Results: There were no significant differences in diabetes-related characteristics for HbA1c, WHR and WTR. However, patients with a family history had low compliance scores (p=.004). Furthermore, patients who visited the hospital regularly had higher compliance scores than patients who visited hospital when they were sick (p<.001). Patients with diabetic complications had low treatment compliance scores (p=.001). In addition, WHR and WTR (r=0.47, p<.001). and WHR and compliance (r=0.15, p=.045) showed positive correlation. Conclusion: For elderly diabetes mellitus patients, diabetes-related characteristics and compliance were highly related, so it is necessary to improve compliance for managing diabetes mellitus.