• 제목/요약/키워드: Compensation reactive power

검색결과 298건 처리시간 0.036초

전압형 능동필터에 의한 교류고조파제거와 무효전력보상 (AC harmonic elimination and reactive power compensation by voltage-type active filter)

  • 김한성;최규하;신우석;이제필
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국내학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.688-692
    • /
    • 1988
  • The active filter system for harmonic current compensation is presented in this paper. The active filter, composed of a three-phase voltage-type PWM inverter and the capacitor, compensates both the harmonic currents and the reactive power by injecting the PWM current to the ac line. This paper describes the principle of harmonic current compensation, the calculation circuits for the harmonic currents to be injected, the several compensation characteristics. Also the experimental results are shown to verify the theory proposed in this paper.

  • PDF

400MW 급 해상풍력 발전단지의 계통연계를 위한 AC 외부망 해저케이블의 송전전압 선정 및 무효전력 보상 방안 연구 (A study on the transmission voltage selection of an AC export cable system and countermeasures to compensate for its reactive power for the connection of a 400 MW offshore wind farm to a power system)

  • 강숙현;김인재
    • 풍력에너지저널
    • /
    • 제13권1호
    • /
    • pp.21-29
    • /
    • 2022
  • With the technological advances of offshore wind turbines, the share of power generated by offshore wind farms in power systems is increasing significantly. An export cable transmission system is necessary to connect offshore wind farms to power systems. The voltage rating and reactive power compensation methods of the export transmission system are very critical, as they can influence the power transmission capacity and CAPEX. With this in mind, this paper suggests an acceptable transmission voltage and reactive power compensation method for an export cable system connecting a 400[MW] offshore wind farm to a power system.

실시간 디지털 시뮬레이터(Hypersim)을 이용한 이차적 전압제어 제어기 구현 (The realization of secondary voltage controller using real-time digital simulator(Hypersim))

  • 김봉식;서상수;이병준;송인준;신정훈;김태균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.269-271
    • /
    • 2006
  • In power system, the reactive power is closely associated with voltage. In addition Reactive power has localized characteristic. Recently wide area blackout caused by reactive power imbalance. Therefore it is important to control reactive power considering its characteristic. Until now maintenance of system voltage has been controlled by shunt compensation rather than generators. However because of a large time-constant, shunt compensators are difficult to manage disturbances immediately. In addition shunt compensation has discrete characteristic, which make disturbances in system. In this paper we studied the voltage maintenance method of local buses by controlling the reactive power output of a generator which is closely related a load bus in addition the proposed method was verified by test system.

  • PDF

Multi-Function Distributed Generation with Active Power Filter and Reactive Power Compensator

  • Huang, Shengli;Luo, Jianguo
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1855-1865
    • /
    • 2018
  • This paper presents a control strategy for voltage-controlled multi-function distributed generation (DG) combined with an active power filter (APF) and a reactive power compensator. The control strategy is based on droop control. As a result of local nonlinear loads, the voltages of the point of common coupling (PCC) and the currents injecting into the grid by the DG are distorted. The power quality of the PCC voltage can be enhanced by using PCC harmonic compensation. In addition, with the PCC harmonic compensation, the DG offers a low-impedance path for harmonic currents. Therefore, the DG absorbs most of the harmonic currents generated by local loads, and the total harmonic distortion (THD) of the grid connected current is dramatically reduced. Furthermore, by regulating the reactive power of the DG, the magnitude of the PCC voltage can be maintained at its nominal value. The performance of the DG with the proposed control strategy is analyzed by bode diagrams. Finally, simulation and experimental results verify the proposed control strategy.

Secondary Voltage Control for Reactive Power Sharing in an Islanded Microgrid

  • Guo, Qian;Wu, Hongyan;Lin, Liaoyuan;Bai, Zhihong;Ma, Hao
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.329-339
    • /
    • 2016
  • Owing to mismatched feeder impedances in an islanded microgrid, the conventional droop control method typically results in errors in reactive power sharing among distributed generation (DG) units. In this study, an improved droop control strategy based on secondary voltage control is proposed to enhance the reactive power sharing accuracy in an islanded microgrid. In a DG local controller, an integral term is introduced into the voltage droop function, in which the voltage compensation signal from the secondary voltage control is utilized as the common reactive power reference for each DG unit. Therefore, accurate reactive power sharing can be realized without any power information exchange among DG units or between DG units and the central controller. Meanwhile, the voltage deviation in the microgrid common bus is removed. Communication in the proposed strategy is simple to implement because the information of the voltage compensation signal is broadcasted from the central controller to each DG unit. The reactive power sharing accuracy is also not sensitive to time-delay mismatch in the communication channels. Simulation and experimental results are provided to validate the effectiveness of the proposed method.

계통 연계형 풍력발전 시스템의 고조파 저감 및 무효전력 보상 (Reduction of Harmonics and Compensation of Reactive Power about Wind Power Generation System Connected to Grid)

  • 김영민;황종선;김종만;박현철;송승호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.1093-1096
    • /
    • 2002
  • In this paper, a novel multi voltage inverter system is proposed for reductions of harmonics, which can compensate reactive power. At first, we remove capacitor at input side for reactive power compensation. Secondly, by adding DC voltage to the filter capacitor, it can control power factors as lead-phase according to alterations of loads at power reception. Thirdly, if winding and single phase-bridge inverter(auxiliary circuit) is installed to DC power for reduction of harmonic, waveform of output voltages become to 36-steps. Thus, SVC(static var compensator) systems which can reduce harmonics are designed.

  • PDF

Intervening Firing Method and Passive Filter Design for Harmonic Elimination and Reactive Power Compensation in Three-Phase Thyristor Phase-Controlled Converters Supplying a DC Motor

  • Pattanapongchai, Artite;Wongtongdee, Surached W.;Laohasongkram, Piphat
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.813-816
    • /
    • 2005
  • This paper presents a method for harmonic elimination and reactive power compensation using an intervening firing method and passive power filter with is suitable to compensate rapidly changing loads and reactive power. The proliferation of three-phase thyristor phase-controlled converter of DC motor drives into a power system has the potential to increase the harmonic levels in the power system. The design procedure of an intervening firing method and passive power filter capable of reducing the voltage and current harmonics produced by converter supplied from a source having internal large inductive impedance is offered. The analysis uses the or CAD PSpice to model three-phase thyristor phase-controlled converter of DC motor drives as well as the system.

  • PDF

고조파와 무효전력 보상기능을 가지는 Smart PCS의 새로운 제어 알고리즘 (Novel control algorithm for smart PCS with harmonics and reactive power compensation)

  • 서효룡;장성재;박상수;김상용;김경훈;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1053_1054
    • /
    • 2009
  • A significant number of renewable energy systems have been connected to the grids as supplement power source. The renewable energy systems require control algorithm to maintain the power-supply reliability and quality. This paper proposes a novel control algorithm for smart Power Conditioning System (PCS) with harmonics and reactive power compensation. The smart PCS is used to feed Photovoltaic (PV) power to utility and compensate harmonics and reactive power at the same time. The experimentation is carried out on the proposed grid-connected PV generation system, and controlled by digital signal processor. The grid-connected PV generation system injects PV energy into the grid and performs as Active Filter (AF) and Static Synchronous Compensator (STATCOM) without additional devices. The experiment results show that the proposed control algorithm is effective for smart PCS with harmonics and reactive power compensation.

  • PDF

Control Strategy and Characteristic Analysis of Hybrid Active Power Filters with the Resonant Impedance Principle

  • Fang, Lu;Xu, Xian-Yong;Luo, An;Li, Yan;Tu, Chun-Ming;Fang, Hou-Hui
    • Journal of Power Electronics
    • /
    • 제12권6호
    • /
    • pp.935-946
    • /
    • 2012
  • A new kind of resonant impedance type hybrid active filter (RITHAF) is proposed for dynamic harmonic current suppression and high capacity reactive compensation in medium and high voltage systems. This paper analyzed the different performance of the RITHAF when the active part of the RITHAF is controlled as a current source and as a voltage source, respectively. The harmonic suppression function is defined in this paper. The influences of the changes caused by the grid impedance and the detuning of the passive power filter on the compensating characteristics of the RITHAF are studied by analyzing the suppression function. Simulation and industrial application results show that the RITHAF has excellent performances in harmonic suppression and reactive compensation, which is suitable for medium and high voltage systems.

고전압 무효전력 보상기를 사용한 대규모 풍력발전 설비의 전력 품질 보상 (Control of Power Quality Using a High Voltage STATCOM for the Integration of Large Scale Wind Power Plant)

  • 김지홍;송승호;정승기
    • 신재생에너지
    • /
    • 제8권4호
    • /
    • pp.13-20
    • /
    • 2012
  • This paper describes a transformerless static synchronous campensator (STATCOM) system based on cascade H-bridge multilevel inverter with star configuration. It is designed not only for the dynamic and continuous compensation of the reactive power but also for the improvement of power quality of existing wind power plant. Especially, when the induction generator of wind turbine is directly connected to the grid, reactive power are occurred by exiting current. so a reactive power compensation system based on the cascade H-bridge multilevel STATCOM is proposed because the output power quality and controllability of reactive power are required by grid code in many different countries. Using various The proposed reactive power control strategy using a STATCOM is compared with the conventional scheme using fixed-size of capacitor bank through various simulation results.