• Title/Summary/Keyword: Comparison factor

Search Result 3,219, Processing Time 0.043 seconds

The characteristics on dose distribution of a large field (넓은 광자선 조사면($40{\times}40cm^2$ 이상)의 선량분포 특성)

  • Lee Sang Rok;Jeong Deok Yang;Lee Byoung Koo;Kwon Young Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.19-27
    • /
    • 2003
  • I. Purpose In special cases of Total Body Irradiation(TBI), Half Body Irradiation(HBI), Non-Hodgkin's lymphoma, E-Wing's sarcoma, lymphosarcoma and neuroblastoma a large field can be used clinically. The dose distribution of a large field can use the measurement result which gets from dose distribution of a small field (standard SSD 100cm, size of field under $40{\times}40cm2$) in the substitution which always measures in practice and it will be able to calibrate. With only the method of simple calculation, it is difficult to know the dose and its uniformity of actual body region by various factor of scatter radiation. II. Method & Materials In this study, using Multidata Water Phantom from standard SSD 100cm according to the size change of field, it measures the basic parameter (PDD,TMR,Output,Sc,Sp) From SSD 180cm (phantom is to the bottom vertically) according to increasing of a field, it measures a basic parameter. From SSD 350cm (phantom is to the surface of a wall, using small water phantom. which includes mylar capable of horizontal beam's measurement) it measured with the same method and compared with each other. III. Results & Conclusion In comparison with the standard dose data, parameter which measures between SSD 180cm and 350cm, it turned out there was little difference. The error range is not up to extent of the experimental error. In order to get the accurate data, it dose measures from anthropomorphous phantom or for this objective the dose measurement which is the possibility of getting the absolute value which uses the unlimited phantom that is devised especially is demanded. Additionally, it needs to consider ionization chamber use of small volume and stem effect of cable by a large field.

  • PDF

Evaluation of Detector Dependency on Collimator in SRS: Compared Detectors; CC01, CC13, SFD (뇌정위적 방사선수술 시 콜리메이터 크기 변화에 따른 검출기 의존성 평가)

  • Bae, Yong-Ki;Bang, Dong-Wan;Park, Byung-Moon;Kang, Min-Yeong;Kim, Yeon-Rye
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.109-113
    • /
    • 2008
  • Purpose: To evaluate the detector dependency in the various collimator size for Stereotactic Radiosugery (SRS). Materials and Methods: This study was performed with 6 MV photon beam (Varian 21EX, Varian, US) and the measurement detectors are used by ion chamber CC01, CC13 (Wellhofer, Germany) and stereotactic diode detector (SFD, Wellhofer, Germany). SRS collimator size was used by ${\varphi}$5, 10, 20, 30 mm (Brain Lab, Germany). Percentage depth dose (PDD) was measured at SSD 100 cm and field size 10×10 cm from individual detectors. Ouput factor was measured by using same setup of PDD and with maximum dose depth. Data was normalized at field size $10{\times}10\;cm$. Beam profile was measured at SSD 100 cm in SRS collimator ${\varphi}$10, 30 mm and field $10{\times}10\;cm$ and a comparison of FWHM (full width half maximum), penumbra width (20~80%). Results: The CC13 detector was overestimated 16% than other detectors from the PDD in the 5 mm collimator. Output factors were underestimated CC01 28%, CC13 72% in the 5 mm collimator and CC01 9.6%, CC13 25% in the 10 mm collimator than the SFD. Maximum difference was 3% at the FWHM of the dose profile in the 10 mm collimator and difference of the 30 mm collimator was 0% at the FWHM. Penumbra width was increased CC01 122%, CC13 194% in the 10 mm collimator and CC01 68%, CC13 185% in the 30 mm collimator than the SFD. Conclusion: It is very important for accurate dosimetry to select a detector in small field. The SFD was considered with the most accurate dosimeter for small collimator dosimetry in this study.

  • PDF

Comparison of Amphotericin B and Itraconazole as Empirical Antifungal Therapy in Children with Acute Leukemia with Neutropenic Fever (발열을 동반한 호중구감소 상태의 급성백혈병 환아에서 경험적 항진균제로 투여한 Amphotericin B와 Itraconazole의 효과와 이상 반응 비교)

  • Lee, Sang-Yun;Park, Jong-Sun;Kim, Sun-Young;Yang, Keum-Jin;Park, Kyung-Deok;Kim, Hack-Ki
    • Pediatric Infection and Vaccine
    • /
    • v.12 no.1
    • /
    • pp.75-85
    • /
    • 2005
  • Purpose : Fungal infection is one of the important causes of morbidity and mortality in patients with hematologic malignancies. Amphotericin B(ABV) and itraconazole(ITZA) have been used as the standard empirical antifungal therapy in neutropenic patients with acute leukemia who have persistent fever that does not respond to antibiotic therapy. ABV is an antifungal drug associated with side effects such as fever and chills, symptoms which may be mediated by pro-inflammatory cytokines such as interleukin-$1{\beta}$(IL-$1{\beta}$) and tumor necrosis factor-${\alpha}$(TNF-${\alpha}$). We assessed modulation of these pro-inflammatory cytokines as well as the anti-inflammatory cytokines(IL-4, IL-1Ra) by ABV and ITZA. Methods : From March 2004 to February 2005, a total of 30 episodes from acute leukemia patients with febrile neutropenia were analyzed for this study. They were randomly allocated to receive intravenous ABV or ITZA for 14 days. Clinical responses were evaluated at the completion of therapy, and cytokine IL-$1{\beta}$, TNF-${\alpha}$, IL-4, and IL-1Ra were measured for determination to know the correlation between two antifungal agents and inflammatory cytokines. Results : Empirical antifungal agents were given to 37 patients(ABV 20, ITZA 17), and 30 patients(ABV 15, ITZA 15) were evaluable for efficacy. White blood cell and absolute neutrophil count in the group treated with ITZA increased early days of treatment, so the duration of neutropenia in ITZA group is shorter. Serum creatinine level is lower in ITZA group than in ABV group but this is not statistically significant. There was no significant difference in response rate between two groups. The IL-$1{\beta}$ was increased in ABV treatment group and the ratio of IL-1Ra/IL-$1{\beta}$ is markedly decreased in ABV treatment group while increased in ITZA group. Conclusion : ITZA and ABV have at least equivalent efficacy as empirical antifungal therapy in neutropenic children with acute leukemia. However ITZA is associated with significantly less toxicity in clinical and molecular aspects.

  • PDF

Clinical Study on Hemolytic Uremic Syndrome in Children: Review of 23 Cases (소아 용혈성 요독 증후군 23예에 대한 임상적 고찰)

  • Oh Seungjin;Yook Jinwon;Kim Ji Hong;Kim Pyung-Kil
    • Childhood Kidney Diseases
    • /
    • v.4 no.2
    • /
    • pp.136-143
    • /
    • 2000
  • Purpose : The hemolytic uremic syndrome (HUS) is characterized by microangiopathic hemolytic anemia thrombocytopenia, and acute renal failure. It is ole of tile most common cause of acute renal failure in children but few reports are available in Korea. Thus we investigated the 23 patients diagnosed as HUS during last 14 years. Method : We retrospectively investigated the etiologic factor, clinical manifestations laboratory findings, treatment modalities, and final outcomes of the patients. Then patients were divided into two groups according to outcome, md comparison was performed. Group A(8) comprised patients who progressed to end-stage renal disease or expired. Group B(15) comprised patients who completely recovered after dialysis treatment. Result The number of patients aged less than 4 years were 17; between 5 and 10 were 4 and more than 10 were 2. The gende ratio was M:F=2 : 1. The etiologic factors were as follows: acute gastroenteritis in 14 patients including 4 bloody diarrhea, upper respiratory tract infection in 7 patients, and 1 patient with herbal mediation. The overall mortality rate was 22$\%$: 2 patients died of US complications, 2 patients died of sepsis, and 1 patient died of pulmonary hemorrhage. Group A (Hb 4.8${\pm}$1.2 g/dL) showed lower value in hemoglobin than group B (Hb 6.3${\pm}$1.7 g/dL) during hospital stay (P< 0.05), And the time interval between tile disease onset and dialysis treatment was significantly longer in group A ($11.9{\pm}9.1\;days\;vs\;2.8{\pm}2.1\;days$) (P< 0.05). Conclusion : Overall mortality rate was 22$\%$. Low hemoglobin value and the prolonged time interval between the disease onset and dialysis treatment were related with poor prognosis. So early diagnosis and appropriate intensive care including dialysis treatment is essential to achieve better outcome in children.

  • PDF

Influence of Glass Dielectric Property on the External Electrode Fluorescent Lamps (유리관의 유전 특성이 외부전극 형광램프에 미치는 영향)

  • Shin, Myeong-Ju;Jeong, Jong-Mun;Kim, Jung-Hyun;Kim, Ga-Eul;Lee, Mi-Ran;Yoo, Dong-Gun;Koo, Je-Huan;Hong, Byoung-Hee;Choi, Eun-Ha;Cho, Guang-Sup
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.5
    • /
    • pp.330-337
    • /
    • 2007
  • Influence of glass dielectric property (dielectric constant K, dielectric loss) on the external electrode fluorescent lamps of the dielectric barrier discharge has been investigated with 4-different glasses. Conventional borosilicate glass tubes with $K=5.6{\sim}5.9$ and tan ${\delta}=5.0{\times}10^{-3}{\sim}6.0{\times}10^{-3}$ and aluminosilicate glass tubes with high K=6.6 and low tan ${\delta}=1{\times}10^{-4}$ and soda-lime glass tribes with K=7.7 and tan ${\delta}=1.37{\times}10^{-2}$ have been compared. The high value of dielectric constant K makes the capacitance of external electrode fluorescent lamps intensity and enhances the discharge efficiency. The dielectric loss of tan ${\delta}$ shows the factor of power consumption in the external electrode to induce heats and to be weak in pinhole stability. The aluminosilicate glass tubes of high K and low tan ${\delta}$ have been enhanced by $14{\sim}18%$ in luminance and efficiency in comparison with the conventional borosilicate glass tubes and the aluminosilicate external electrode fluorescent lamps are strong against the pinhole formation. Soda-lime glass tubes with high K and high tan ${\delta}$ are a little favorable in luminance and efficiency and they are very weak in pinhole occurrence.

Comparison of $^{18}F$ FDG-PET and CT/MRI for the Diagnosis of Cervical Lymph Node Metastasis in Head and Neck Cancer: A Level-by-Level Based Study (두경부암 환자에서 경부 림프절 전이에 대한 $^{18}F$ FDG-PET과 CT/MRI의 진단적 정확도 비교: 림프절군에 따른 연구)

  • Yang, Yoo-Jung;Kim, Jae-Seung;Kim, Sang-Yun;Lee, Ho-Gyu;Nam, Soon-Yul;Choi, Seung-Ho;Ryu, Jin-Sook;Yeo, Jeong-Seok;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.52-61
    • /
    • 2004
  • Purpose: Cervical lymph node metastasis is the most important factor of the prognosis and therapeutic planning in head and neck cancer. With increasing interest of minimally invasive neck surgery, more accurate preoperative assessment of cervical lymph node becomes more essential. We evaluated the diagnostic accuracy of $^{18}F$ FDG-PET in the assessment of lymph node metastasis in patients with primary head and neck cancer and compared the results with those of CT/MRI. Materials and Methods: Thirty-two patients (M/F=27/5, $56{\pm}10yr$) with biopsy proven head and neck cancer (16 supraglottic cancer, 9 tongue cancer, 7 others) underwent FDG-PET and CT/MRI (25/7) within 1 month before neck dissection. Based on lymph node level, the diagnostic sensitivity and specificity of FDG PET and CT/MRI for the metastasis of cervical lymph node were compared. Results: Of 153 lymph node levels dissected in 32 patients, 32 lymph node levels of 19 patients were positive for metastasis by histopatholologic examination. The overall sensitivity and specificity of FDG-PET were 88% (28/32) and 93% (113/121), whereas those of CT/MRI were 56% (18/32) (p=0.002) and 92% (112/121), respectively. The diagnostic sensitivity and specificity of FDG-PET were different according to location of lymph node levels, and those of ipsilateral level 11 were lower than those of other levels. Conclusion: FDG-PET is more sensitive in detecting metastatic cervical lymph node in head and neck cancer than CT/MRI. FDG-PET might be useful in guiding the extent of neck dissection.

The Usefulness of LEUR Collimator for 1-Day Basal/Acetazolamide Brain Perfusion SPECT (1-Day Protocol을 사용하는 Brain Perfusion SPECT에서 LEUR 콜리메이터의 유용성)

  • Choi, Jin-Wook;Kim, Soo-Mee;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.94-100
    • /
    • 2011
  • Purpose: Basal/Acetazolamide-challenged brain perfusion SPECT is very useful to assess cerebral perfusion and vascular reserve. However, as there is a trade off between sensitivity and spatial resolution in the selection of collimator, the selection of optimal collimator is crucial. In this study, we examined three collimators to select optimal one for 1-day brain perfusion SPECT. Materials and Methods: Three collimators, low energy high resolution-parallel beam (LEHR-par), ultra resolution-fan beam (LEUR-fan) and super fine-fan beam (LESFR-fan), were tested for 1-day imaging using Triad XLT 9 (TRIONIX). The SPECT images of Hoffman 3D brain phantom filled with 99mTc of 170 MBq and a normal volunteer were acquired with a protocol of 50 kcts/frame and detector rotation of 3 degree. Filterd backprojection (FBP) reconstruction with Butterworth filter (cut off frequencies, 0.3 to 0.5) was performed. The quantitative and qualitative assessments for three collimators were performed. Results: The blind tests showed that LESFR-fan provided the best image quality for Hoffman brain phantom and the volunteer. However, images for all the collimator were evaluated as 'acceptable'. On the other hand, in order to meet the equivalent signal-to-noise ratio (SNR), total acquisition time or radioactivity dose for LESFR-fan must have been increased up to almost twice of that for LEUR-fan and LEHR-par. The volunteer test indicated that total acquisition time could be reduced approximately by 10 to 14 min in clinical practice using LEUR-fan and LEHR-par without significant loss on image quality, in comparison with LESFR-fan. Conclusion: Although LESFR-fan provides the best image quality, it requires significantly more acquisition time than LEUR-fan and LEHR-par to provide reasonable SNR. Since there is no significant clinical difference between three collimators, LEUR-fan and LEHR-par can be recommended as optimal collimators for 1-day brain perfusion imaging with respect to image quality and SNR.

  • PDF

Prevalence of Human Papillomavirus by DNA Chip Test in Women (여성에 있어 DNA 칩검사에 의한 인유두종바이러스 감염률의 조사)

  • Kim, Jae-Woo;Kim, Yun-Tae;Kim, Dae-Sik;Choi, Seok-Cheol
    • Journal of Life Science
    • /
    • v.18 no.12
    • /
    • pp.1657-1664
    • /
    • 2008
  • We determined the prevalence of human papillomavirus (HPV) by DNA chip test in 549 women and cytologic diagnosis. 237 of 549 women (43.17%) subjected with HPV DNA Chip examination were found positive for HPV. 210 (88.60%, High group) were infected with high-risk HPV types. 17 (7.17%, Low group) were infected with low-risk HPV types (6, 11, 40, 44, 70) and 17 (7.17%, Mixed group) were infected with mixed types. According to age, in their twenties, thirties, forties, fifties and over sixties, the prevalence of infection with high-risk HPV types were 1.26% (3/237), 15.61% (37/237), 31.65% (75/237), 23.21% (55/237), and 13.92% (33/237), respectively. In the Low and Mixed group, percentages of infection with HPV were significantly lower than that of the High group. On the comparison of cytologic diagnosis (224 women) by Pap smear and DNA chip positive (237 women) for HPV, 132 out of 194 cases in the High group (68.04%) suffered cervical lesions with ASCUS (atypical squamous cells of undetermined significance, 7.22%), LSIL (low grade squamous intraepithelial lesion, 15.98%), HSIL (high grade SIL, 23.20%) and ICC (invasive cervical cancer, 21.65%). The Low group (14/224 women) showed 1 case of ASCUS and 6 cases of LSIL, whereas the Mixed group (4/224 women) had only 2 cases of ASCUS. According to the HPV subtypes, the high-risk types 16 and 18 induced 26 and 7 cases of ICC, respectively, whereas other HPV subtypes induced lower or no ICC incidence. In conclusion, the present data imply that the prevalence of HPV was 43.17%, high-risk HPV type 16 is a major factor, which causes precancerous and/or cervical cancer in woman and that HPV DNA chip is an accurate and useful tool for detecting HPV.

The Comparison Evaluation of SUV Using Different CT Devices in PET/CT Scans (PET 검사에서 CT 장비의 차이에 따른 PET/CT의 SUV 비교 평가)

  • Kim, Woo Hyun;Go, Hyeon Soo;Lee, Jeong Eun;Kim, Ho Sung;Ryu, Jae Kwang;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.10-18
    • /
    • 2014
  • Purpose: Among different PET/CT devices which are composed of same PET model but different CT models, SUV, usually used for quantitative evaluation, was measured to assess the accuracy of follow up scans in different PET/CT and confirm that interequipment compatibility is useful in arranging the PET/CT exam appointment. Materials and Methods: Using ACR PET Phantom, PET NEMA IEC Body Phantom, SNM Chest Phantom and Ge-68 cylinder Phantom, $SUV_{mean}$ and $SUV_{max}$ was measured by 3 different models of PET/CT (Discovery 690, Discovery 690Elite and Discovery 710, GE) made in same company. ANOVA was used to evaluate the significant difference in the result. Results: In the result, the average of $SUV_{max}$ was D690 (25 mm-1.82, 16 mm-1.75, 12 mm-1.73, 8 mm-1.44), D690E (25 mm-1.76, 16 mm-1.92, 12 mm-1.78, 8 mm-1.55) and D710 (25 mm-1.84, 16 mm-1.89, 12 mm-1.77, 8 mm-1.61) in ACR Phantom, D690 (25 mm-2.26, 16 mm-2.25, 12 mm-1.92, 8 mm-1.85), D690E (25 mm-2.45, 16 mm-2.25, 12 mm-2.05 8 mm-1.91) and D710(25 mm-2.49, 16 mm-2.20, 1 2mm-2.30, 8 mm-2.05) in PET NEMA IEC Body Phantom, D690-1.04, D690E-1.10 and D710-1.09 in SNM Chest Phantom and D690-0.81, D690E-0.81, D710-0.84 in Ge-68 cylinder Phantom. The differences between average SUV of 4 phantoms were $SUV_{mean}$-1.87%, $SUV_{max}$-2.15%. And also as a result of ANOVA analysis, there was no significant difference statistically. Conclusion: If different models of PET/CT have same specification of PET system, there was no significant difference in $SUV_{mean}$ and $SUV_{max}$ even though they have different CT system. And also differences of $SUV_{mean}$ and $SUV_{max}$ in phantom images were under 5% which many manufacturers recommend. Therefore, follow up scan will be possible using different PET/CT if it has same specification of PET system with the previous PET/CT. This information will enable the accurate comparative analysis when conducting follow up scans and be helpful to schedule PET/CT exam more effectively.

  • PDF

Composition and pollution characteristics of TSP, PM2.5 atmospheric aerosols at Gosan site, Jeju Island (제주도 고산지역 TSP, PM2.5 대기에어로졸의 조성 및 오염 특성)

  • Lee, Soon-Bong;Kang, Chang-Hee;Jung, Duk-Sang;Ko, Hee-Jung;Kim, Haeng-Bum;Oh, Yong-Soo;Kang, Hae-Lim
    • Analytical Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.371-382
    • /
    • 2010
  • TSP and PM2.5 atmospheric aerosols have been collected at Gosan site of Jeju Island, and their compositions were analyzed to understand the pollution characteristics. The composition ratios of nss (non-sea salt)-$SO_4^{2-}$ and $NH_4^+$ were higher in Gosan site than those in other Korean background and urban sites. However the composition ratio of $NO_3^-$ was conversely lower in Gosan site. From the study of aerosol components according to particle sizes, the anthropogenic nss-$SO_4^{2-}$, $NO_3^-$ and $NH_4^+$ components were mostly existed in the fine particles. But the nss-$Ca^{2+}$, $Na^+$, $Cl^-$ and $Mg^{2+}$ originated from soil and marine sources were distributed relatively in the coarse particles. In the seasonal comparison, the concentrations of nss-$Ca^{2+}$, Al, Fe, Ca and $NO_3^-$ increased in spring season, and nss-$SO_4^{2-}$ showed higher concentration in summer and spring seasons. Based on the factor analysis, the atmospheric aerosols in Gosan site have been found to be influenced largely by anthropogenic sources, and next by marine and soil sources. The backward trajectory analyses showed that the concentrations of nss-$SO_4^{2-}$, $NO_3^-$, Pb and nss-$Ca^{2+}$ increased when the air mass moved from Chinese continent to Jeju area. On the other hand, their concentrations decreased when the air mass moved in from the North Pacific Ocean.