• 제목/요약/키워드: Comparision

Search Result 881, Processing Time 0.028 seconds

Comparision of Clustering Methods in 2D Image for the Atomstion of Dangerous Machine (위험기계의 자동화를 위한 2차원 영상의 군집화 기법 비교 연구)

  • 이지용;이병곤
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.1
    • /
    • pp.39-45
    • /
    • 1996
  • In this study, clustering of black BADUK stones' image were performed to recognize the individual stone from its closely spaced and partially occluded Image. And the clustering perfomance was compared between the classical methods and fuzzy C-means method. As a result, 2 BADUK stones' image was segmented precisely in every methods, but more than 3 stones the segmentation was depended on its shape. Fuzzy C-means method could be segmented correctly to 4 stones regardless of its shape, and It could be applied to the unknown number of clusters.

  • PDF

Development of an Electric Vehicle Simulation Program (전기자동차의 주행성능 프로그램 개발)

  • Gwon, O-Geon;Gu, Jeong-Seo;Choe, Jin-Min
    • 연구논문집
    • /
    • s.22
    • /
    • pp.55-64
    • /
    • 1992
  • A simulation program is developed to analyse the driving performance of an electric vehicle. It is composed of the structured modules modelled after the functional components of the electric vehicle. This program can be used conveniently in the conceptual design stage of a new electric vehicle. The comparision of the test data of ETX-1 developed by Ford with the calculated results shows reasonable agreement within 15% error.

  • PDF

Analyses and Comparision of Block Encryption Algorithm in Wireless Network (이동통신망 환경에 적합한 블럭 암호 알고리즘의 비교 분석)

  • Jung Sung-Hyuk;Kim Jung-Tae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.769-772
    • /
    • 2006
  • 본 논문에서는 기존의 관용알고리즘을 비교 분석하고, 유무선 복합 통신망에서의 고속화를 위해 요구되는 암호알고리즘을 비교 분석한다. 기존에 사용되고 있는 블록 알고리즘의 경우, 고비도에 의해서 소프트웨어적 혹은 하드웨어적으로 설계하였을 경우, 현재의 이동통신망에 사용을 하였을 경우, 속도의 차이에 의해 사용이 불가능하다. 따라서, 본 논문에서는 이동통신 환경망에 적합한 블록알고리즘을 제안하고 분석하고자 한다.

  • PDF

A Study on Cutting Model for the Plastic Deformation on Turning Operation (선삭 가공면의 변형에 관한 절삭모델에 대한 연구)

  • Cha, Il-Nam;Kim, Yoon-Jeh
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.5 no.1
    • /
    • pp.29-39
    • /
    • 1988
  • Plastically deformed layer beneath metal surface machined by orthogonal cutting was evaluated in terms of residual stress, microvickers hardness, side spread, and the side strain. An attempt was made to predict the depth of layer according to machining conditions particularly tool geometry and the shear plane angle. In this paper, we employed two models concerning the sliplines. The exact model was validated by comparision of computed and measured tool force and its angle, and the model offers an upper boundary of the deformed layer to be in good agreement with the experiment.

  • PDF

A Study on the Comparision of Domestic Pleasure Boat Inspection Guidline with International Standards(ISO) (국내 플레저보트 검사지침 및 국제표준규격의 비교 검토)

  • Lee, Chan-Jae;Lee, Hee-Joon
    • Journal of Korea Ship Safrty Technology Authority
    • /
    • s.28
    • /
    • pp.64-77
    • /
    • 2010
  • 본 연구는 2008년 범선 및 플레저보트 검사지침 이후 국내의 플레저보트 관련 검사기준의 변화과정을 살펴보고 2009년 9월 새로이 제정된 플레저보트 검사치침과 국제표준화기구 (ISO)의 소형선박분야 기술위원회(TC188)에서 제정한 플레저보트 관련 국제표준의 주요내용을 비교 검토함으로써 관련규정에 대한 사용자의 이해를 높이는 동시에 향후 국내 플레저보트 검사지침의 개선방향을 검토하기 위하여 추진되었다.

  • PDF

A Comparision of Diagnostic Measures in Linear Regression (회귀진단을 위한 새로온 척도의 제안 및 상호비교)

  • 최성운
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.15 no.25
    • /
    • pp.103-113
    • /
    • 1992
  • This paper is to study the various diagnostic measures for detecting outliers and influential cases in linear regression. In this paper we review the most common diagnostic measures and show the inter-relationships the exist among them. Based on the PRESS(Predicted REsidual Sum of Squares ) offered by Allen(1974) as a criterion for model selection, we propose three measures for detecting outliers and influential cases. Examples are given illustrating various diagnostic measures including Proposed measures.

  • PDF

HISTOMORPHOMETRIC AND REMOVAL TORQUE VALUES COMPARISION OF ROUGH SURFACE TITANIUM IMPLANTS (임프란트 표면처리 방법에 따른 골유착의 조직계측학적 분석 및 제거회전력 비교 연구)

  • Lee, Sang-Chul;Song, Woo-Sik
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.5
    • /
    • pp.396-405
    • /
    • 2001
  • Osseointegrated implants are used for the fixation of dental prosthesis with good long-term clinical results. In an attempt to improve the quantity and quality of the bone-implant interface, numerous implant modification have been used. Implants surface modifications have been used such as titanium-plasma sprayed, hydroxyapatite-coating, sandblasted, sandblasted and acid-etched, acid-etched. Rough surface implants have greater implant surface area and enhance the bone-implant interface and improve stabilization. The purpose of present study was to evaluate light microscopic and scanning microscopic examinations and removal torque value of newly developed calcium phosphate blast and acid-etched implant in the femur of rabbits. Titanium plasma sprayed(TPS) implant served as controls. After 12 weeks of healing of the femurs of 12 rabitts, the implant-containing segments of femur were removed on bloc and bone block including sections. Histologic examination and histomorphometric and removal torque values comparision were made for two implants. Obtained results are follows: 1. Newly developed calcium phosphate blasted and acid-etched implants were in close contact with bone under light microscopic examinations. 2. New implants showed mean bone-to implant contact 59.8%, whereas TPS implants showed mean bone-to implant contact 54.5% (statistically no difference p<0.05). 3. New implants showed mean bone density 56.7%, whereas TPS implants showed mean bone density 49.2% (statistically difference p<0.05). 4. New implants demonstrated mean removal torque values 40.5Ncm, whereas the mean removal torque values of TPS implants ranged 39.3Ncm. No statistical differences(p<0.05) were observed between two groups of implants nor was there any difference between the two implants at the clinical level.

  • PDF

A Study on the Slacks Pattern Making according to the Movement-Fitness [Part II] -On the Hip Region- (동작적합성에 따른 Slacks Pattern 설계에 관한 연구[Part II] -엉덩이 부위를 중심으로-)

  • 박영득
    • Journal of the Korean Home Economics Association
    • /
    • v.35 no.4
    • /
    • pp.159-172
    • /
    • 1997
  • The purpose of this study was to investigate the slacks pattern making on the movement -fitness of the hip region. The experimental items were divided into the 5 lower limb movements(M1-M5) and the 12 revision pattern constructions of slacks. This study was done by clothing pressure test sensory evaluation test and the difference shape-transformation of wearing-slacks. The summarized finding resulted from experiments and investigation are suggested as follows: First by the clothing pressure tested by lower limb movements the clothing pressure score of the rabbit leap movement(M3) was the highest of all lower limb movements and the order of it in the another movement was the sit on knee(M4) the sit on chair(M2) the noble sitting(M5) from the highest to the lowest. And in comparision of clothing pressure tested by revision pattern to cover the extend of crotch-length 20。 inclined back-line construction method (CA4) showed the lowest. And in comparision of clothing pressure tested by revision pattern to cover the extend of crotch-length 20。 inclined back-line construction method (CA4) showed the lowest. And also for a role to cover hip circumference extendign CC4(1/5 hip.1cm longrightarrow linked back -line) method showed the lowest. Second by the sensory evaluation test based on the movement and revision patterns it was found that the functional factor score of the rabbit leap movement was the lowest in all movement however the score of revision patterns were higher than basic pattern. Third by the test to show difference in the shape-transformation of wearing-slacks on chair(M2) also need to be analyzed. The ration of the shape-transformation of the knee region showed the least value in the increased patterns of inclined angle of back-line(CA) and the differential methods of back-line inclined pattern making. But that of the hem-line did not show remarkable difference.

  • PDF

Effects of Hyangsayukgunjatang and Hyangsayukgunjatang-ga-kyenegum, moryobun on experimental gastric ulcers in rats (향사육군자탕(香砂六君子湯) 및 향사육군자탕가계내김모려분(香砂六君子湯加鷄內金牡蠣粉)이 백서(白鼠)의 위궤양(胃潰瘍)에 미치는 영향(影響))

  • Han Hyun-Hee;Byun Joon-Seok
    • Herbal Formula Science
    • /
    • v.6 no.1
    • /
    • pp.157-173
    • /
    • 1998
  • The following study looked at the effects of Hyangsayukgunjatang and Hyangsayukgunjatang-ga-kyenegum, moryobun on gastric ulcers in rats. In the 1st experiment, ulcers were induced by method of shay's pylorus-ligated in rats. Subjects were administered 2 kinds of medicine, Hyangsayukgunjatang and Hyangsayukgunjatang-ga-kyenegum, moryobun, which were taken orally. The quantity of gastric juice secretion, total acidity of gastric juice, HCI secretion and serumgastrin content were measured and tissues of gastric mucosa epithelium were observed. 1. The quantity of gastric juice secretion in Hyangsayukgunjatang-treated and Hyangsayukgunjatang-ga-kyenegum, moryobun-treated groups showed significant decrease incomparision with the control group. 2. In relation to total acidity of gastric juice, only Hyangsayukgunjatang -treated groupshowed significant decrease in comparison with the control group. 3. HCI secretion of Hyangsayukgunjatang-treated and Hyangsayukgunjatang-ga-kyenegum, moryobun-treated groups showed significant decrease in comparision with the control group. 4. Content of serum gastrin, which were present in Hyangsayukgunjatang -treated and Hyangsayukgunjatang-ga-kyenegum, moryobun- treated groups showed significant decrease in comparision with the control group. 5. The degree of ulcer occurrence & parietal cell numbers and chief cell numbers of Hyangsayukgunjatang-treated and Hyangsayukgunjatang-ga-kyenegum, moryobun-treatedgroups, which were observed by macrographic & histologic method showed signicant decreasein comparison with the control group. Hyangsayukguniatang-treated group prooved to be increasingly effective. From above the experiment results it can be concluded that Hyangsayukgunjatang will be more clinical effective on curing gastric ulcers induced by method of Shay's pylorus-ligated rather than that of Hyangsayukgunjatang-ga-kyenegum, moryobun.

  • PDF