• 제목/요약/키워드: Common-Mode

검색결과 853건 처리시간 0.025초

PWM 스위칭 기법에 의한 유도전동기 구동시스템의 전도노이즈 저감 (Conducted EMI reduction of Induction Motor Drive System by PWM switching technique)

  • 천광수;이원철;김이훈;김수석;원충연
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.540-545
    • /
    • 2004
  • Conventional SVPWM method has null switching vectors. Null switching vectors cause common-mode voltage making high in induction motor drive system. New SVPWM method without using null switching vectors are proposed in the paper. So, new SVPWM method reduces the common mode voltage for induction motor drive system. It is realized by changing software without adding hardware to induction motor drive system. Simulation results show that common-mode voltage adapting proposed method are reduced regarding conventional method.

  • PDF

PWM 인버터로 구동된 유도전동기의 누설전류 억제에 관한 연구(I) (A Study on the Simulation method for the common-mode voltage and current in the voltage fed PWM inverter system)

  • 전진휘;이재호;이상훈;김철우
    • 전력전자학회논문지
    • /
    • 제5권3호
    • /
    • pp.246-253
    • /
    • 2000
  • 전동기의 제어기법과 제어기 등의 발달로 유도전동기는 산업용으로 널리 보급되고 있으며, 유도전동기를 고효율로 제어하기 위하여 PWM 인버터가 널리 사용되고 있다. 그리고 IGBT와 같은 고속 스위칭 소자의 발달로 인해 전압형 PWM 인버터의 스위칭 주파수가 증가가 가능하게 됐으며, 그로 인해 매우 우수한 동작 특성을 가지게 되었다. 그러나 고속 스위칭은 전압과 전류의 급격한 변화로 인해 매 스위칭마다 발생하는 고주파 성분의 커먼 모드전압과 전류를 발생하게 되고 이들은 베어링 전류와 축전압, 전도 및 방사 EMI, 기기의 절연수명 단축, 등의 악영향을 유발한다. 본 연구에서는 이러한 커먼 모드 전압과 전류에 대한 시스템 레벨 해석이 가능한 시뮬레이션 기법에 대해 실제 측정과 시뮬레이션을 통해 검정하였다. 이를 통해서 커먼 모드 전압과 전류가 PWM 인버터 시스템의 각 부에 미치는 영향을 쉽게 확인 할 수 있으며, 커먼 모드 전압과 전류의 저감을 위해 추가될 수 있는 부가적인 보조회로의 영향에 대해서도 제시된 시뮬레이션 기법을 통해 확인 할 수 있다.

  • PDF

Carrier Based Common Mode Voltage Reduction Techniques in Neutral Point Clamped Inverter Based AC-DC-AC Drive System

  • Ojha, Amit;Chaturvedi, Pradyumn;Mittal, Arvind;Jain, Shailendra
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.142-152
    • /
    • 2016
  • Common mode voltage (CMV) generation is a major problem in switching power converter fed induction motor drive systems. CMV is the zero sequence voltage generated due to the switching action of power converters. Even a small magnitude of CMV with a high rate of change may circulate large bearing currents which may damage a machine's bearings and shorten its life. There are several methods of controlling CMV. This paper presents 3-level sinusoidal pulse width modulation based techniques to control the magnitude and rate of change of CMV in multilevel AC-DC-AC drive systems. Simulation and experimental investigations have been presented to validate the performance of proposed technique to control CMV in 3-level neutral point clamped inverter based AC-DC-AC system.

A New Reduced Common-mode Voltage SVM Method for Indirect Matrix Converters with Output Current Ripple Minimization

  • Tran, Quoc-Hoan;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.383-384
    • /
    • 2015
  • This paper presents a new space vector modulation (SVM) method for indirect matrix converters (IMCs) to reduce commonmode voltage as well as minimize output current ripple in a high voltage transfer ratio. In the proposed SVM, the three-vector modulation scheme is used in the rectifier stage, while the nonzero state modulation technique, where the three nearest active vectors are selected to synthesize the desired output voltage, is applied to inverter stage to reduce the CMV. The proposed SVM method can significantly reduce the output current ripple and common-mode voltage of the IMC without any extra hardware. Simulated results are provided to demonstrate the effectiveness of the proposed SVM method.

  • PDF

오프셋 보정 기술을 이용한 비냉각형 적외선 센서용 신호검출 회로 설계 (Design of Readout IC for Uncooled Infrared Bolometer Sensor using Bias Offset Correction Technique)

  • 박상원;황상준;홍승우;정은식;성만영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.23-25
    • /
    • 2005
  • Infrared bolometer sensor's variation is detected by voltage drop between reference resistor and bolometer resistor in this architecture. One of the serious problems in this architecture is that these resistors value has a process variation. So common-mode level could be different from expectation in room temperature. Different common-mode level could lead to wrong output at the end of readout circuit. We suggest useful method to solve this problem. Difference correction using capacitor has reduced CM level difference to 86% for 1 $M\Omega$. bolometer and reference resistor's 10% variation.

  • PDF

A Model Predictive Control Method to Reduce Common-Mode Voltage for Voltage Source Inverters

  • Vu, Huu-Cong;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 추계학술대회 논문집
    • /
    • pp.209-210
    • /
    • 2015
  • This paper presents a new model predictive control method without the effect of a weighting factor in order to reduce common-mode voltage (CMV) for a three-phase voltage source inverter (VSI). By utilizing two active states with same dwell time during a sampling period instead of one state used in conventional method, the proposed method can reduce the CMV of VSI without the weighting factor. Simulation is carried out to verify the effectiveness of the proposed predictive control method with the aid of PSIM software.

  • PDF

Common-Mode Voltage and Current Harmonic Reduction for Five-Phase VSIs with Model Predictive Current Control

  • Vu, Huu-Cong;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1477-1485
    • /
    • 2019
  • This paper proposes an effective model predictive current control (MPCC) that involves using 10 virtual voltage vectors to reduce the current harmonics and common-mode voltage (CMV) for a two-level five-phase voltage source inverter (VSI). In the proposed scheme, 10 virtual voltage vectors are included to reduce the CMV and low-order current harmonics. These virtual voltage vectors are employed as the input control set for the MPCC. Among the 10 virtual voltage vectors, two are applied throughout the whole sampling period to reduce current ripples. The two selected virtual voltage vectors are based on location information of the reference voltage vector, and their duration times are calculated using a simple algorithm. This significantly reduces the computational burden. Simulation and experimental results are provided to verify the effectiveness of the proposed scheme.

변조지수에 따른 공통모드 전압 저감 PWM 기법 성능 비교 (Performance Comparison of Common-Mode Voltage Reduction PWM Methods in Terms of Modulation Index)

  • 허건;박용순
    • 전력전자학회논문지
    • /
    • 제26권2호
    • /
    • pp.135-140
    • /
    • 2021
  • This study introduces a new pulse width modulation (PWM) method to reduce common-mode voltages (CMVs) and then compares its performance with other reduced CMV-PWM (RCMV-PWM) methods. CMVs should be reduced to ensure the electromagnetic compatibility and safety of grid-connected inverters. RCMV-PWM methods attempt to synthesize voltage references without zero vectors, which cause high CMV peaks. In these methods, the peak-to-peak magnitude of CMVs can be reduced by one-third of the conventional space-vector PWM. The introduced method splits every reference vector into two vectors to avoid the use of zero vectors. The performances of the RCMV-PWM methods are analyzed in accordance with the modulation index through simulation and experiment.

Balance Winding Scheme to Reduce Common-Mode Noise in Flyback Transformers

  • Fu, Kaining;Chen, Wei
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.296-306
    • /
    • 2019
  • The flyback topology is being widely used in power adapters. The coupling capacitance between primary and secondary windings of a flyback transformer is the main path for common-mode (CM) noise conduction. A Y-cap is usually used to effectively suppress EMI noise. However, this results in problems in space, cost, and the danger of safety leakage current. In this paper, the CM noise behaviors due to the electric field coupling of the transformer windings in a flyback adapter with synchronous rectification are analyzed. Then a scheme with balance winding is proposed to reduce the CM noise with a transformer winding design that eliminates the Y-cap. The planar transformer has advantages in terms of its low profile, good heat dissipation and good stray parameter consistency. Based on the proposed scheme, with the help of a full-wave simulation tool, the key parameter influences of the transformer PCB winding design on CM noise are further analyzed. Finally, a PCB transformer for an 18W adapter is designed and tested to verify the effectiveness of the balance winding scheme.

3상 3-레벨 컨버터의 누설전류 저감과 NP 전류 제어를 위한 캐리어 기반 LFCPWM (Carrier Based LFCPWM for Leakage Current Reduction and NP Current Control in 3-Phase 3-Level Converter)

  • 이은철;최남섭
    • 전력전자학회논문지
    • /
    • 제27권5호
    • /
    • pp.446-454
    • /
    • 2022
  • This study proposes a carrier-based pulse width modulation (PWM) method for leakage current reduction and neutral point (NP) current control in a three-phase three-level converter, which is a carrier-based PWM version of the previously proposed low-frequency common mode voltage PWM. Three groups of space vectors with the same common mode voltage are used. When the averaged NP current needs to be positive or negative, the specific groups are employed to produce low-frequency common mode voltages. The validity of the proposed PWM method is verified through experiments.