• Title/Summary/Keyword: Common point

Search Result 2,012, Processing Time 0.026 seconds

Stereo Matching the Orientation Point Using the Method of Color Channel Separation (색상분리기법을 이용한 표정점의 스테레오 매칭)

  • 이재기;이현직;박경식
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.15 no.1
    • /
    • pp.41-50
    • /
    • 1997
  • This study is aimed to suggest the method, color channel seperation, can match the common points in real-time automatically. Image coordinates which was calculated from the acquired image with CCDcamera in this study is checked with two methods; check the accuracy of image coordinate and common point matching through correct sort. In conclusion of check, The RMSE of object coordinate which is calculated by photogrammetry program with image coordinate is in the expect RMSE of close-range photogrammetry, and Match-ing of common point is also performed correctly by using sort. For these reason, this color channel separation method is adequate for the acquisition of accurate image coordinates and the matching of the common points. I think that this method will be useful for the fields of industry which need fast-correct processing with acquired information in real-time.

  • PDF

A Study on Lightning Overvoltage Characteristics of Grounding Systems in Underground Distribution Power Cables

  • Jung, Chae-Kyun;Jung, Yeon-Ha;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.628-634
    • /
    • 2014
  • This paper investigates the transient characteristics of grounding systems used in under-ground distribution power cables. Recently, two kinds of grounding system are used for underground distribution cables in Korea. The first one is conventional multi-point grounding system, the other is newly proposed non-bundled common grounding system. The non-bundled common grounding system has an advantage the decreasing the power loss due to decrease of the shield circulation current. In this paper, the lightning overvoltage induced in neutral wire (in case of non-bundled common grounding system, overvoltage between opened neural wires and grounding in each phase) of these two kinds of grounding systems are estimated and compared by field tests and EMTP simulations. The EMTP simulation methods are firstly verified by comparison of measurement and simulation. Finally, the insulation level against lightning is expected by EMTP simulation results using verified model.

Control Strategy Compensating for Unbalanced Grid Voltage Through Negative Sequence Current Injection in PMSG Wind Turbines

  • Kang, Jayoon;Park, Yonggyun;Suh, Yongsug;Jung, Byoungchang;Oh, Juhwan;Kim, Jeongjoong;Choi, Youngjoon
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.244-245
    • /
    • 2013
  • This paper proposes a control algorithm for permanent magnet synchronous generator with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage offshore wind power system under unbalanced grid conditions. The proposed control algorithm particularly compensates for the unbalanced grid voltage at the point of common coupling in a collector bus of offshore wind power system. This control algorithm has been formulated based on the symmetrical components in positive and negative rotating synchronous reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power are described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of ac input current is injected to the point of common coupling in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm makes it possible to provide a balanced voltage at the point of common coupling resulting in the generated power of high quality from offshore wind power system under unbalanced network conditions.

  • PDF

Design of Low-Power Media Bus (저전력 미디어 버스 설계)

  • Roh, Chang-Gu;Moon, Byung-In;Lee, Yong-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.2
    • /
    • pp.437-444
    • /
    • 2010
  • The audio data have been communicated using analog methods or simple protocols. However, with the advent and improvement of various multimedia functions, many audio devices have been integrated into a mobile handset in which interconnection lines are very complicated. Conventional point-to-point connections such as $I^2S$ and PCM demand more power consumption whenever more devices are attached. In this paper, we design a common bus digital audio interface that communicates with only two wires and employs the clock gear method to reduce bus power consumption. The comparison results show that the proposed common bus connection can reduce more than 30% of power consumption as compared with point-to-point connection if more than three devices are connected.

Low-area FFT Processor Structure using $Radix-4^2$ Algorithm ($Radix-4^2$알고리즘을 사용한 저면적 FFT 프로세서 구조)

  • Kim, Han-Jin;Jang, Young-Beom
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.3
    • /
    • pp.8-14
    • /
    • 2012
  • In this paper, a low-area FFT structure using $Radix-4^2$ algorithm is proposed. The large point FFT structure consists of cascade connection of the many stages. In implementation of large point FFT using $Radix-4^2$ algorithm, stages which number of different coefficients are only 3 appear in every 2 stages. For example, in the 4096-point FFT, the stages that number of different coefficients are 3 appear in stage 1, 3, and 5 among 6 stages. Multiplication block area of these 3 stages can be reduced using CSD(Canonic Signed Digit) and common sub-expression sharing techniques. Using the proposed structure, the 256-point FFT is implemented with the Verilog-HDL coding and synthesized by $1.971mm^2$ cell area in tsmc $0.18{\mu}m$CMOS library. This result shows 23% cell area reduction compared with the conventional structure.

WEAK CONVERGENCE TO COMMON FIXED POINTS OF COUNTABLE NONEXPANSIVE MAPPINGS AND ITS APPLICATIONS

  • Kimura, Yasunori;Takahashi, Wataru
    • Journal of the Korean Mathematical Society
    • /
    • v.38 no.6
    • /
    • pp.1275-1284
    • /
    • 2001
  • In this paper, we introduce an iteration generated by countable nonexpansive mappings and prove a weak convergence theorem which is connected with the feasibility problem. This result is used to solve the problem of finding a solution of the countable convex inequality system and the problem of finding a common fixed point for a commuting countable family of nonexpansive mappings.

  • PDF

COMMON FIXED POINT THEOREM AND INVARIANT APPROXIMATION IN COMPLETE LINEAR METRIC SPACES

  • Nashine, Hemant Kumar
    • East Asian mathematical journal
    • /
    • v.28 no.5
    • /
    • pp.533-541
    • /
    • 2012
  • A common fixed point result of Gregus type for subcompatible mappings defined on a complete linear metric space is obtained. The considered underlying space is generalized from Banach space to complete linear metric spaces, which include Banach space and complete metrizable locally convex spaces. Invariant approximation results have also been determined as its application.

WEAK AND STRONG CONVERGENCE OF THREE-STEP ITERATIONS WITH ERRORS FOR TWO ASYMPTOTICALLY NONEXPANSIVE MAPPINGS

  • Jeong, Jae-Ug
    • Journal of applied mathematics & informatics
    • /
    • v.26 no.1_2
    • /
    • pp.325-336
    • /
    • 2008
  • In this paper, we prove the weak and strong convergence of the three-step iterative scheme with errors to a common fixed point for two asymptotically nonexpansive mappings in a uniformly convex Banach space under a condition weaker than compactness. Our theorems improve and generalize some previous results.

  • PDF